• 제목/요약/키워드: Ultrasonic Parameters

검색결과 324건 처리시간 0.024초

Inverse Analysis of Ultrasonic Signals of Ceramics Based on Ultrasonic Self-Compensating Technique

  • Lee Joon-Hyun;Cheng Ansheng
    • Journal of Mechanical Science and Technology
    • /
    • 제20권2호
    • /
    • pp.185-190
    • /
    • 2006
  • An ultrasonic self-calibrating technique for the characterization of a ceramic which was fabricated by change pressing time during the HIP process has been applied by using the ratio of the reflection and transmission coefficients of normal incidence longitudinal waves. The ratio is self-compensated, in that it is independent of the characteristics for transmission and reception of ultrasound by the transducer and the condition of the couplant. The insensitive direction in parameter space is defined as the direction in which the variation of the ratio to changes of two parameters vanishes. For inverse problem the distribution of minima in an error surface is investigated.

초음파 위치인식 시스템과 INS 결합을 통한 차량의 자율 주행 (Autonomous Navigation of the Vehicle Via Ultrasonic Positioning System and INS Integration)

  • 신택영
    • 한국산업융합학회 논문집
    • /
    • 제26권2_2호
    • /
    • pp.359-370
    • /
    • 2023
  • For a vehicle to follow a reference path accurately, its position must be estimated accurately and reliably. In this paper, we propose a lateral control algorithm for autonomous navigation of a vehicle via USAT(Ultrasonic Satellite System), which is an absolute position measurement system using an ultrasonic wave and INS(Inertial Navigation System) integration. In order to estimate the vehicle's parameters, a J-turn test is used. And the autonomous navigation performances of proposed lateral control algorithm and validity of proposed lateral control algorithm are verified and evaluated by simulation and experiments.

초음파속도를 이용한 암석의 일축압축강도와 탄성계수 예측 (Predicting the Uniaxial Compressive Strength and Young's Modulus of Rocks using Ultrasonic Velocity)

  • 최길현;백승철
    • 한국지반환경공학회 논문집
    • /
    • 제15권2호
    • /
    • pp.53-58
    • /
    • 2014
  • 암석의 일축압축강도와 탄성계수는 암반구조물의 설계에 있어 매우 중요한 해석 변수이다. 그러나 일축압축시험은 시험시편 준비가 어렵고 시간이 오래 걸린다. 그래서 기술자들은 해석변수를 예측하기 위해 초음파속도시험과 같은 실험을 이용한다. 본 연구를 위해 115개의 화성암, 74개의 변성암, 55개의 퇴적암을 대상으로 일축압축시험과 초음파시험을 수행하고 회귀분석하여 일축압축강도와 탄성계수의 관계식을 구하였다. 일축압축강도와 P파속도의 더 좋은 상관성을 구하기 위해 P파속도에 단위중량을 곱한 값을 이용하였다. 초음파속도를 이용하여 일축압축강도와 탄성계수를 구하는 관계식은 신뢰할 수 있는 결과를 얻을 수 있었다.

골다공증 진단을 위한 초음파 변수의 골밀도에 대한 의존성 (Dependences of Ultrasonic Parameters for Osteoporosis Diagnosis on Bone Mineral Density)

  • 황교승;김윤미;박종찬;최민주;이강일
    • 비파괴검사학회지
    • /
    • 제32권5호
    • /
    • pp.502-508
    • /
    • 2012
  • 현재 골다공증 진단을 위하여 임상에서 이용되고 있는 정량적 초음파 기술은 종골(발뒤꿈치뼈)에서 음속(speed of sound; SOS) 및 광대역 초음파 감쇠(normalized broadband ultrasound attenuation; nBUA)와 같은 초음파 변수를 측정한다. 본 연구에서는 소 대퇴골로부터 제작된 20개의 해면질골 샘플을 이용하여 골절 위험도가 높은 대퇴골에서 SOS 및 nBUA의 골밀도에 대한 의존성을 살펴보았다. 대퇴골 해면질골 샘플의 SOS 및 nBUA는 1.0 MHz의 중심주파수를 갖는 한 쌍의 초음파 트랜스듀서와 함께 투과법을 이용하여 측정 하였다. 20개의 해면질골 샘플에서 측정된 SOS 및 nBUA는 골밀도와 각각 r = 0.83 및 0.72라는 높은 Pearson 상관계수 (r)를 갖는 것으로 나타났다. 또한 SOS 및 nBUA를 독립변수로 하고, 골밀도를 종속변수로 하는 다중선형회귀분석으로부터 다중선형회귀모델의 상관계수는 r = 0.85로서 SOS 또는 nBUA 중 하나만을 독립변수로 하는 단순선형회귀모델의 상관계수보다 높게 나타났다. 이와 같이 초음파 변수와 골밀도 사이의 높은 선형적인 상관관계는 대퇴골에서 측정된 초음파 변수가 대퇴골의 골밀도를 예측하기에 충분한 지표라는 것을 의미한다.

디지털 초음파 신호처리 기법을 이용한 열처리된 스테인레스 스틸의 그레인 크기 결정에 관한 연구 (A Study on the Determination of Grain Size of Heat-treated Stainless Steel Using Digital Ultrasonic Signal Processing Techniques.)

  • 임내묵;이영석;김성환
    • 한국음향학회지
    • /
    • 제18권8호
    • /
    • pp.84-93
    • /
    • 1999
  • 본 논문에서는 디지털 신호처리기법을 기초로 한 열처리된 스테인레스 스틸의 그레인 크기에 대한 결정 방법을 제안하였다. 이 방법은 여러 개의 특징 파라메터들, 차분절대평균값, 분산, 평균주파수, 자귀회귀모델계수 그리고, 선형켑스트럼 계수를 이용하여 증거축적방법을 통해 수행한다. 각각의 특징파라메터는 열처리된 금속에 초음파를 발사하여 돌아온 반사신호를 가지고 추출된다. 실험 결과로서 몇 개의 특징파라메터만 가지고는 열처리된 금속의 그레인 크기를 정확하게 결정할 수 없음을 확인하였다. 열처리된 금속의 그레인 크기에 대한 결정은 기준 파라메터로부터 측정한 거리를 이용한 증거축적방법을 사용하였으며, 퍼지매핑함수를 도입하여 이를 응용하였다. 본 논문의 실험을 위해 다양한 그레인 크기를 가진 열처리된 스테인레스 스틸 금속을 사용하였으며, 이러한 실험결과로부터 본 논문에서 제안한 방법이 지금까지 발표된 그레인 크기 결정방법보다 효과적임을 입증하였다.

  • PDF

초음파 결합형 SBR 호기성 소화의 모델과 매개변수의 보정 (Numerical Model for SBR Aerobic Digestion Combined with Ultrasonication and Parameter Calibration)

  • 김성홍;이인호;윤정원;이동우
    • 상하수도학회지
    • /
    • 제27권4호
    • /
    • pp.457-468
    • /
    • 2013
  • Based on the activated sludge model(ASM), a mathematical model which represents the aerobic sludge digestion by sequencing batch reactor(SBR) combined with ultrasonic treatment was composed and performed in this study. Aerobic digestion using sequencing batch reactor(SBR) equipped with ultrasound treatment was also experimented for the purpose of parameter calibration. Most of the presented kinetic parameters in ASM or ASM2 could be used for the aerobic digestion of sludge but the parameters related in hydrolysis and decay rate needed modification. Hydrolysis rate constant of organic matter in aerobic condition was estimated at $0.3day^{-1}$ and the maximum growth rate for autotrophs in aerobic condition was $0.618day^{-1}$. Solubilization reactions of particulate organics and nitrogen by ultrasonication was added in this kinetic model. The solubilization rate is considered to be proportional to the specific energy which is defined by specific ultrasound power and sonication time. The solubilization rate constant by ultrasonication was estimated at $0.202(W/L)^{-1}day^{-1}$ in this study. Autotrophs as well as heterotrophs also decomposed by ultrasonic treatment and the nitrification reaction was limited by the lack of autotrophs accumulation in the digester.

초음파 비선형 음향 효과 및 X-선 회절법을 이용한 2.25Cr-1Mo 강의 열화 손상 평가 (Evaluation of Thermal Degradation of 2.25Cr-1Mo Steel Using Ultrasonic Nonlinear Effect and X-ray Diffraction Method)

  • 김덕희;박은수;박익근;변재원;권숙인
    • 한국안전학회지
    • /
    • 제17권4호
    • /
    • pp.71-79
    • /
    • 2002
  • It was attempted to evaluate the degree of degradation of thermally aged 2.25-1Mo steek by ultrasonic monlinear parameter(UNP) measurement and X-ray diffraction analysis of extracted carbide. Artificial aging was performed to simulate the microstructural degradation in 2.25Cr-1Mo steel arising from long time exposure at $540{\circ}C$. Microstructural analysis (number of carbides per unit area) and measurements of mechanical properties(Vickers hardness, DBTT) and degradation evaluation parameters(UNP and intensity ration of X-ray diffraction peak of electrolytically extracted carbide) were performed. Both of UNP and intensity ratio of X-ray diffraction peak for M6C carbide to that of M23C6 carbide(IR) increased abruptly in the initial 1000 hour of aging and then changed little. UNP and IR were proposed as potential parameters to evaluate the degree of aging degradation of 2.25Cr-1Mo steel.

Ultrasonic waves in a single walled armchair carbon nanotube resting on nonlinear foundation subjected to thermal and in plane magnetic fields

  • Selvamani, Rajendran;Jayan, M. Mahaveer Sree;Ebrahimi, Farzad
    • Coupled systems mechanics
    • /
    • 제10권1호
    • /
    • pp.39-60
    • /
    • 2021
  • The present paper is concerned with the study of nonlinear ultrasonic waves in a magneto thermo (MT) elastic armchair single-walled carbon nanotube (ASWCNT) resting on polymer matrix. The analytical formulation is developed based on Eringen's nonlocal elasticity theory to account small scale effect. After developing the formal solution of the mathematical model consisting of partial differential equations, the frequency equations have been analyzed numerically by using the nonlinear foundations supported by Winkler-Pasternak model. The solution is obtained by ultrasonic wave dispersion relations. Parametric work is carried out to scrutinize the influence of the non local scaling, magneto-mechanical loadings, foundation parameters, various boundary condition and length on the dimensionless frequency of nanotube. It is noticed that the boundary conditions, nonlocal parameter, and tube geometrical parameters have significant effects on dimensionless frequency of nano tubes. The results presented in this study can provide mechanism for the study and design of the nano devices like component of nano oscillators, micro wave absorbing, nano-electron technology and nano-electro- magneto-mechanical systems (NEMMS) that make use of the wave propagation properties of armchair single-walled carbon nanotubes embedded on polymer matrix.

LMS 알고리즘을 이용하는 적응형 초음파 빔포밍 시스템에서 초기치 설정이 수렴 특성과 스텝 파라미터의 여유도에 미치는 영향 (Effect of Initial Value Setting on Convergence Characteristics and Margin of Step Parameters in an Adaptive Ultrasonic Beamforming System using LMS Algorithm)

  • 채광철;조기량
    • 한국전자통신학회논문지
    • /
    • 제18권2호
    • /
    • pp.241-250
    • /
    • 2023
  • 본 논문에서는 적응형 초음파 빔포밍 시스템에 LMS 알고리즘을 이용하는 때에 초기치 설정이 스텝 파라미터의 여유도에 미치는 영향을 연구하였다. 이를 위하여 임의로 설정한 빔폭을 갖는 준이상 빔과 회전 빔에 대한 빔포밍에 대해서 검토하였다. 수치 실험은 초음파 빔포밍 시스템에 임의의 초기치(음원수는 임의의 수로 고정)를 설정하고, 이에 대한 스텝 파라미터의 여유도와 수렴 특성 등을 비교하였다.

3차원 음장 분석법을 이용한 진단용 초음파 프로브의 정량적 성능평가 (Quantitative evaluating method for diagnostic ultrasound probe using 3-dimensional acoustic field analysis)

  • 노시철;김주영;박재현;김진수;강정훈;최흥호
    • 센서학회지
    • /
    • 제19권6호
    • /
    • pp.490-496
    • /
    • 2010
  • In this study, in order to overcome the weakness of acoustic field analysis which is generally used for ultrasonic probe performance evaluation, automatic acoustic field measurement system and evaluation parameters were proposed. The comparisons between acoustic field simulation and measured acoustic distribution data of normal and abnormal channels were conducted to evaluate the availability of proposed system and evaluation parameters. First, the impulse response characteristic of sample probe was investigated to classify the normal elements and abnormal elements. And then, normal channels and abnormal channels with abnormal element were chosen. The suggested 12 evaluation parameters were calculated using the acoustic fields of these channels. The availability of proposed automatic acoustic field measurement system and evaluation parameters was confirmed. And the performance evaluation of ultrasonic probe using acoustic field analysis could be easier and faster.