• 제목/요약/키워드: Ultrasonic Method

Search Result 2,078, Processing Time 0.025 seconds

Application of Ultrasonic Wave to the Squeezing Process From the Seeds (식물 씨앗의 착유과정에 있어서 초음파의 적용)

  • Kim, Jung-Soon;Lee, Hui-Uk;Kim, Moo-Joon;Ha, Kang-Lyeol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.2
    • /
    • pp.91-96
    • /
    • 2010
  • To improve the limit of efficiency of squeezing oil in a conventional method, which seeds are compressed simply, the adoptability of the additional energy by the ultrasonic wave was investigated experimentally. As the results, using the ultrasonic vibration from the Langevin-type transducer, the efficiency was increased up to 25 %, whereas the conventional method has 15% efficiency. To investigate the additional pressure by the ultrasonic wave, the acoustic impedance of the sample and the vibration velocity of the transducer were measured. Although the amplitude of the ultrasonic is about 2.8 % of the compression pressure, the efficiency is increased a lot as mentioned above because the pressure is changed according to ultrasonic period.

A Selection Method of Resonant Inductance for the Traveling Wave Type Ultrasonic Motor drive System using Series Resonant Inverter (직렬 공진형 인버터를 사용한 초음파 모터 구동시스템의 공진 인덕턴스 선정법)

  • 이을재;김영석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.105-114
    • /
    • 2000
  • To chive a traveling wave type ultrasonic motor with the series""-resonant inverter, the external inductor is i lnserted between the motor and inverter. In $\psi$is paper, we proposed a novel 3Ilalysis method to design the 3 ~xternal inductor. An equivalent model of the ultrasonic motor is expressed, and a selection method of the , ;;eries inductor is proposed from the basis of the model. When the series inductor has an optimal value, it is v velified by computer simulation results that power is efficiently transmitted to the mechanical resonant c component in the motor. The frequency and speed characteristics of the ultrasonic motor are investigated by e experiments for several external inductors. The validity of the proposed method for selecting external inductor i is clarified.clarified.

  • PDF

The Problem and Improvement Plan of Ultrasonic Exploration of Weld Zone in Railway Rails (철도 레일 용접부 초음파 탐상의 문제점 및 개선방안)

  • Jang, Suk-Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.4
    • /
    • pp.123-133
    • /
    • 2004
  • The evaluation standard method of weld zone in rails is not exhibited in case of the domestic and the outside about ultrasonic inspection method. therefore, practical affairs a mans on the ground know very little about evaluation method of pass and failure. This paper discuss about ultrasonic exploration of weld zone in railway rails to know practical affairs a mans that the first, "problem and improvement direction of domestic track construction specifications applied according to a place ordering" and the second, "the method applied of ultrasonic exploration test of weld zone in railway rails".

Evaluation of Washing Method for Sterilization of Gel Container for Ultrasound Inspection (초음파검사용 젤 용기의 제균을 위한 세척방법 평가)

  • Lee, Hee-Jeong;Lee, Suk-Jun;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.41 no.3
    • /
    • pp.241-247
    • /
    • 2018
  • The purpose of this study was to compare the ultrasound gel container washing methods for the sterilization of contaminants and to find the useful methods for the prevention of infection caused by the ultrasonic gel containers. In this experiment, a 250 mL ultrasonic gel container was used, and the ultrasonic gel used was a non-sterile gel (ECO GEL 99, SeungWon Medical, Korea). In order to evaluate the degree of contamination, new 250 mL 15 containers were divided into 5 groups to perform five types of washing by no treatment, washing with water, washing with soap, washing with bottle cleaner and high disinfection level washing. After the washing process, filled the gel container with gel and after 2 weeks, the number of colonies in the gel container was sampled repeatedly twice in the same ultrasonic laboratory and compared before and after washing. As a result of among the five cleaning methods used in this study, 87.2% and 88.9% of the soapy water washing (p = 0.028) and high level washing (p = 0.027) showed significant bacterial reduction rates, respectively. Our findings conclusively an ultrasonic gel container cleaning method for removing contaminants has been found to be an effective sterilization method at a low cost with a soapy water cleaning method. Therefore, it is expected that it will be helpful to prevent the infection caused by the ultrasonic gel container by suggesting the sterilization cleaning method that is practically useful in this study.

A Study on the Measuring Accuracy of Ultrasonic Hardness Tester (초음파 경도계의 측정정도에 관한 연구)

  • Han, Eung-Kyo;Yoon, Jong-Hak;Kim, Jae-Yeor
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.4 no.1
    • /
    • pp.65-73
    • /
    • 1987
  • In recent days, the application of ultrasonics has been increased in the field of engineering and medicine. The ultrasonic hardness tester to apply the principle of contact compliance method is entirely different from hardness tester in the past and in the practical use, the more pre- cisive measurement is required because it has a slight change of hardness value due to the difference of resonance frequency. Therefore, in this study, as one type of applicative transducers which can detect the optimum pressure load, ring type load cell was used in the measurement of ultrasonic hardness. From experimental results, it was compared ultrasonic hardness testing method with the other hardness testing methods. Also, the measurement error of ultrasonic hardness tester could be measured within .+-. 0.5 HRC F.S. in the case of 3.0Kg pressure load.

  • PDF

Ultrasonic Measurement of Interfacial Layer Thickness of Sub-Quarter-Wavelength

  • Kim, No-Hyu;Lee, Sang-Soon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.6
    • /
    • pp.577-582
    • /
    • 2003
  • This paper describes a new technique for thickness measurement of a very thin layer less than one-quarter of the wavelength of ultrasonic wave used in the ultrasonic pulse-echo measurements. The technique determines the thickness of a thin layer in a tapered medium from constructive interference of multiple reflection waves. The interference characteristics are derived and investigated in theoretical and experimental approaches. Modified total reflection wave g(t) defined as difference between total and first reflection waves increases in amplitude as the interfacial layer thickness decreases down to zero. A layer thickness less than one-tenth of the ultrasonic wavelength is measured using the maximum amplitude of g(t) with a good accuracy and sensitivity. The method also requires no inversion process to extract the thickness information from the waveforms of reflected waves, so that it makes possible to have the on-line thickness measurement of a thin layer such as a lubricating oil film in thrust bearings and journal bearings during manufacturing process.

Use of Ultrasonic to Atomizing a Highly Viscous Bio-oil (고점성 바이오유의 분무미립화를 위한 초음파 이용)

  • 주은선;나우정;김종천
    • Journal of Biosystems Engineering
    • /
    • v.21 no.4
    • /
    • pp.467-473
    • /
    • 1996
  • Ultrasonic energy was applied for atomizing rice-bran oil which is a highly viscous bio fuel. Six different nozzles, an injection simulator, and an ultrasonic generator system were designed and constructed for the experiment. An immersion liquid method was used for the measurement of injection droplet sizes. The characteristics of injection droplets was investigated with respect to the numbers of the droplets with diameters ranging from 5$\mu$m 50$\mu$m and to the Sauter mean diameter. The results showed that the ultrasonic energy was effective for the improvement of the atomization of the injection droplets for all the factors such as type of nozzles, nozzle opening pressures, and collection distances.

  • PDF

SAFT Based Imaging and Centroid Technique for Classification of UT Signals from the Steam Generator of a Nuclear Power Plant

  • Kim, Dae-Won
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.3
    • /
    • pp.263-272
    • /
    • 2008
  • Many technical methods are used for nondestructive testing field for solid materials. Among those, ultrasonic inspection methods are widely used and one of the popular methods involves the extraction of an appropriate set of features followed by the use of a neural network for the classification of the signals in the feature space. This paper describes an approach which uses LMS method to determine the coordinates of the ultrasonic probe followed by the use of SAFT with centroid technique to estimate the location of the ultrasonic reflector. The method is employed for classifying UT-NDE signals from the steam generator tubes in a nuclear power plant. The classification results are presented for the ultrasonic signals from cracks and deposits within steam generator tubes.

A Study on the Novel Control Method to Drive the Traveling Wave Type Ultrasonic Motor adapting the Impedance Angle Control (임피던스 위상각제어를 적용한 초음파모터의 구동을 위한 새로운 제어방식에 대한 연구)

  • Lee, Eul-Jae;Kim, Yeong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.6
    • /
    • pp.450-456
    • /
    • 2000
  • In this paper, we proposed a novel control method which uses the internal impedance angles as a control parameter to drive traveling wave type ultrasonic motor. An impedance characteristic of the ultrasonic motor is obtained by analysis of the equivalent circuits including the external inductor used to generate the coupled resonance. The phase angle of internal impedance to achieve optimal control performance is derived. For the tracking of impedance angle, an information of phase difference is obtained from the applied voltage and current. The high speed phase difference detector is designed to monitor the phases of ultrasonic motor. The effectiveness of the proposed control scheme is clarified by experiments.

  • PDF

Morphology, Thermal, Electrical Properties for Epoxy-Layered Silicate Nanocomposites using Homogenizer +Ultrasonic Dispersion Method (Homogenizer+Ultrasonic을 이용한 Epoxy-Layered Silicate Nanocomposites의 구조적, 열적, 전기적 특성연구)

  • Park, Jae-Jun;Um, Ji-Yong;Lee, Chang-Hun;Kim, Min-Kyu;Baek, Kwan-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.287-288
    • /
    • 2008
  • 에폭시-층상실리케이트 나노콤포지트의 균질분산과 층상실리케이트내로 침투되는 박리정도를 향상시키기 위해 친환경적 분산기법인 물리적방법으로 Homogenizer와 Power Ultrasonic를 적용한 기법을 실시하였다. Homogenizer의 최적속도를 얻기 위해 분산시킨 나노콤포지트의 박리정도, 유리천이온도를 구할 수 있었고, Homogenizer와 Ultrasonic을 동시에 적용하여 최적시간을 구하기 위해 적용된 나노콤포지트를 절연파괴 강도의 Weibull Plots을 통하여 판단할 수 있는 좋은 결과를 얻을 수 있었다.

  • PDF