• 제목/요약/키워드: Ultrasonic Irradiation

검색결과 163건 처리시간 0.031초

아노드의 결정성에 따른 전기도금 구리박막의 기계적 특성 연구 (Crystallographic Effects of Anode on the Mechanical Properties of Electrochemically Deposited Copper Films)

  • 강병학;박지은;박강주;유다영;이다정;이동윤
    • 한국재료학회지
    • /
    • 제26권12호
    • /
    • pp.714-720
    • /
    • 2016
  • We performed this study to understand the effect of a single-crystalline anode on the mechanical properties of as-deposited films during electrochemical deposition. We used a (111) single- crystalline Cu plate as an anode, and Si substrates with Cr/Au conductive seed layers were prepared for the cathode. Electrodeposition was performed with a standard 3-electrode system in copper sulfate electrolyte. Interestingly, the grain boundaries of the as-deposited Cu thin films using single-crystalline Cu anode were not distinct; this is in contrast to the easily recognizable grain boundaries of the Cu thin films that were formed using a poly-crystalline Cu anode. Tensile testing was performed to obtain the mechanical properties of the Cu thin films. Ultimate tensile strength and elongation to failure of the Cu thin films fabricated using the (111) single-crystalline Cu anode were found to have increased by approximately 52 % and 37 %, respectively, compared with those values of the Cu thin films fabricated using apoly-crystalline Cu anode. We applied ultrasonic irradiation during electrodeposition to disturb the uniform stream; we then observed no single-crystalline anode effect. Consequently, it is presumed that the single-crystalline Cu anode can induce a directional/uniform stream of ions in the electrolyte that can create films with smeared grain boundaries, which boundaries strongly affect the mechanical properties of the electrodeposited Cu films.

In-vitro and In-vivo Biocompatibility Evaluation of Silica Based Bio-active Glass Prepared by Hydrothermal Method

  • Sarkar, Swapan Kumar;Nguyen, Phuong Thi;Lee, Byong-Taek
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.53.1-53.1
    • /
    • 2011
  • Bioactive glass powders were synthesized by hydrothermal chemical route by the use of ultrasonic energy irradiation. We used sodalime, calcium nitrate tetra hydrate and di ammonium hydrogen phosphate as the precursor material to synthesize $SiO_2$ rich bio-active glass materials. The $SiO_2$ content was varied in the precursor mixture to 60, 52 and 45 mole%. Dense compacts were obtained by microwave sintering at $1,100^{\circ}C$. Mechanical properties were characterized for the fabricated dense bioactive glasses and were found to be comparable with conventional CaO-$SiO_2$-$Na_2O$-$P_2O_5$ bioactive glass. Detailed biocompatibility evaluation of the glass composition was investigated by in-vitro culture of MG-63 cell and mesenchyme stem cell. Cell adhesion behavior was investigated for both of the cell by one cell morphology for 30, 60 and 90 minutes. Cell proliferation behavior was investigated by culturing both of the cells for 1, 3 and 7 days and was found to be excellent. Both SEM and confocal laser scanning microscopy were used for the investigation. Western blot analysis was performed to evaluate the bimolecular level interaction and extent and rate of specific protein expression. The ability to form biological apatite in physiological condition was observed with simulated body fluid (SBF). In-vivo bone formation behavior was investigated after implanting the materials inside rabbit femur for 1 and 3 month. The bone formation behavior was excellent in all the bioglass compositions, specially the composition with 60% $SiO_2$ content showed most promising trend.

  • PDF

음향화학법을 이용한 아연페라이트 나노입자의 합성 (Synthesis of Zinc Ferrite Nanocrystallites using Sonochemical Method)

  • 조준희;고상길;안양규;강건욱;안동현;최은정
    • 한국자기학회지
    • /
    • 제17권2호
    • /
    • pp.71-75
    • /
    • 2007
  • 계면활성제를 첨가한 음향화학적 침전법으로 두 가지 크기의 아연페라이트 나노입자를 합성하였다. 열분석장치(TGA/DSC)를 이용하여 열적 특성 및 결정화 온도를 조사하였고, 결정구조 확인을 위하여 X선 회절실험을 실시하였다. 제조된 입자는 $240^{\circ}C$ 부근에서 결정생성이 시작되었으며, 결정구조는 전형적인 스피넬 구조를 나타내었다. Scherrer식에 의해 측정된 입자의 크기는 11.2nm와 13.4nm이었다. SQUID를 통하여 자기적 성질을 분석한 결과, 작은 크기의 입자에 대한 방해온도 $T_B$(Blocking temperature)가 큰 입자의 경우보다 더 높게 나타났다.

초음파 추출공정을 이용한 닥나무로부터 항산화성분의 추출공정 최적화 (Statistical Optimization of Antioxidant Extraction from Broussonetia kazinoki Using Ultrasound-assisted Extraction)

  • 이승범;박보라;유봉호
    • 공업화학
    • /
    • 제29권5호
    • /
    • pp.565-570
    • /
    • 2018
  • 본 연구에서는 초음파 용매추출공정을 이용하여 닥나무로부터 항산화성분을 추출하고, 중심합성계획모델을 이용하여 추출공정을 최적화하였다. 중심합성계획모델의 반응치로는 추출수율과 DPPH 라디칼소거활성을 설정하고, 독립변수인 추출시간, 주정/초순수 부피비, 초음파 조사세기에 따른 주효과도와 교호효과도를 해석하였다. 추출수율과 DPPH 라디칼소거활성 모두 계량인자의 주효과도와 교호효과도를 모두 고려하였을 때 가장 큰 영향을 미치는 인자는 주정/초순수 부피비이었다. 반응표면분석법을 이용하여 추출공정의 최적화과정을 수행한 결과 최적추출조건은 추출시간(19.92 min), 주정/초순수 부피비(54.23 vol%), 초음파 조사세기(557.65 W)로 나타났다. 이 조건으로부터 예상되는 반응치의 값은 추출수율(38.93 wt%), DPPH 라디칼소거활성(55.33%)으로 나타났다.

초음파 처리에 의한 수화제 현탁액의 분산 특성 (Dispersion Characteristics of Wettable Powder Suspension by Ultrasonication)

  • 나우정;주은선;김영복;송민근;이경렬
    • Journal of Biosystems Engineering
    • /
    • 제28권4호
    • /
    • pp.351-360
    • /
    • 2003
  • This study was carried out to settle the plugging problem which occurs frequently when agricultural wettable powder is used in pest control work using the crushing and the dispersing effects caused by irradiation of ultrasonic wave. Sonication was applied to the wettable powder suspension in a beaker for 30 seconds using a 28 kHz, 200 W PZT BLT, and the image of suspension before and after sonication was observed using a microscope and a SEM. The image of tow commercial wettable powder suspensions in water observed using an optics microscope showed that the agglomerated particles were irregularly distributed over the whole observed region when stirred mechanically, while showing more uniform distribution composed of comparatively single particles in the whole observed region after sonication. Concerning the above, the projected areas of particles in the four suspensions after sonication were decreased distinctively in the observed range of the microscope and the atomization of crystals was much developed. Over the measured range of 5.6∼4,157 ${\mu}$m particle size, the overall projected area of particles was decreased to 58.3∼89.6% on the average after sonication. When the SEM images of sonicated wettable powder suspensions dissolved in water and CH$_3$OH were compared to the suspensions before sonication, such phenomena as the atomization of particles, the expansion of voids between particles, the reduction and the decrease of agglomerated particle groups, and the progress of crack developments on the surface of flake-shaped particles were observed. It seemed possible that the plugging problem that occurs frequently in pest control machine when using wettable powder would be settled by the use of sonication.

초음파를 활용한 식품 살균 기술의 연구 현황 (Current status of research on microbial disinfection of food using ultrasound)

  • 송경모
    • 식품과학과 산업
    • /
    • 제53권3호
    • /
    • pp.277-283
    • /
    • 2020
  • 식품의 보존성 및 안전성 증대를 위해 살균이 필수적이다. 일반적으로 가열 살균 기술이 가장 많이 사용되고 있으나, 공정 중 식품의 품질 저하를 막기 위한 살균 기술로 신공정 기술을 활용한 비가열 살균 기술의 중요성이 대두되고 있다. 그 중에서도 초음파 기술은 특유의 캐비테이션 현상으로 미생물의 파괴가 촉진되어 살균 효과를 내는 것으로 알려져 있다. 초음파 기술 단독으로는 사멸 효과가 낮으며, 다양한 공정기술과 함께 적용하여 사멸 효과를 극대화할 수 있는 기술 개발을 위한 연구가 활발히 진행되고 있다. 초음파와 함께 처리할 수 있는 공정으로는 가열, 고압, 화학적 처리 등 전통적인 살균 방법 뿐 아니라 자외선 조사, PEF 등 신공정 기술이 있다. 초음파 기술을 적용한 다른 공정과 달리 살균 기술은 아직 실험실 수준에 머물러 있어 산업적 적용을 위한 장치의 개발, 최적 공정 확립 등 추가 연구가 필요하다.

골반부 암 치료 시 초음파검사를 통한 방광체적과 CBCT영상 방광체적의 비교 (A comparison of bladder volume by sonogram and CBCT for Pelvic region cancer)

  • 손성호;박하령;백정진;손종기;최민호
    • 대한방사선치료학회지
    • /
    • 제31권2호
    • /
    • pp.7-12
    • /
    • 2019
  • 목 적: 골반부 방사선 치료 시 방광체적에 따라 방사선 조사범위가 달라지기 때문에 방광체적을 조절하여 치료를 진행한다. 따라서 본 연구에서는 초음파펄스진단장치(BVI 6100, (주)메디칼써프라이)를 이용하여 방광체적 변화를 추적하여 BVI의 정확성을 평가하고자 한다. 대상 및 방법: 2017년 1월부터 2018년 9월까지 부산대학교병원에서 골반부 방사선 치료를 받은 환자 19명을 대상으로 하였다. 치료 시 BVI를 이용하여 획득한 방광체적과 CBCT영상에서 획득한 방광체적을 구간별로 비교한 후 그 유의성을 평가하였다. 결 과: 전체 체적 구간에서의 BVI와 CBCT는 r=0.773의 유의한 상관관계가 나타났으나 치료계획영상에서의 방광체적을 기준으로 p값이 125~175cc에서는 0, 175~275cc에서는 0.05보다 낮게, 그리고 275~375cc에서는 0.05보다 높게 나타났다. 결 론: 본 연구에서는 방광체적이 275cc 이상의 환자의 경우 BVI와 CBCT영상 간의 방광체적이 유의성이 있으나 방광을 비우는 환자의 경우 BVI측정의 신뢰성이 떨어진다고 판단할 수 있었다. 따라서 175~275cc 환자에 대해서는 BVI의 보정값을 이용하여 적절한 체적오차허용범위를 사용하면 유의한 값을 얻을 수 있을 것이다.

수류확산과 초음파와 오존을 이용한 현장 수질 개선 평가 (Field Study of Water Quality Improvement by Circulation, Sonication and Ozonation)

  • 테킬안디넷;김일호;이재엽
    • 한국물환경학회지
    • /
    • 제33권2호
    • /
    • pp.170-180
    • /
    • 2017
  • 본 연구에서는 수원 여천천에서 원천저수지로의 유입부 정체수역에 수류확산장치, 초음파와 오존 처리를 구성한 시스템이 수질에 미치는 영향을 항목 단위로 조사하였다. 샘플링은 기기 운전 전과 이후 1, 3, 6 시간에 여섯 지점에서 수집되었다. 수류확산장치만을 작동하였을 때, 용존산소는 80%까지 감소하였고, Chl-a는 하류 25m에서 3시간 후 90%까지 감소했다. 초음파를 병행한 경우에는 장치로부터 100 m 거리까지 Chl-a가 80% 이상 제거되었다. 한편 총 용존 인은 초음파 처리 전 $420({\pm}70){\mu}g/L$에서 처리 후 $160({\pm}40){\mu}g/L$까지 감소되었다. 수류확산장치와 초음파에 오존을 처리한 결과, Chl-a는 암모니아성 질소가 $60{\mu}g/L$에서 $20{\mu}g/L$으로 감소하였다. 오존의 경우 안전을 위해 $3{\times}10^{-3}mg/L$ 및 짧은 반응 시간으로 적용하였으나 시스템에 의한 장치 구성이 오존을 비롯한 처리를 통합하는 효과를 낼 수 있었다. 본 연구로부터 수류확산장치와 초음파 가 보여준 Chl-a의 탁월한 처리 성능은 녹조 형성을 방지하는 효과적인 방안으로 제시될 수 있다.

초음파 방법을 이용한 ZnO 나노입자 합성 및 광촉매 특성 연구 (Sonochemical Synthesis and Photocatalytic Characterization of ZnO Nanoparticles)

  • 김민선;김재욱;유정열;김종규
    • 대한화학회지
    • /
    • 제60권1호
    • /
    • pp.34-38
    • /
    • 2016
  • 본 연구는 zinc acetate dihydrate와 sodium hydroxide를 사용하여 ZnO nanoparticles (ZnO NPs)을 합성하였다. 실험에 사용된 방법은 초음파 방법이다. 같은 농도의 각각 zinc acetate dihydrate와 sodium hydroxide를 de-ionized water에 넣고 30분간 교반 하였다. 이 과정에서 생성된 백색의 생성물은 교반 하면서 ultrasonic processor을 사용하여 각각 60분, 120분, 180분, 240분, 360분 처리하였다. 생성물들은 원심분리 후 남은 이온들을 제거하기 위하여 에탄올을 사용하여 여러 번 세척하고, 50 ℃에서 24시간 동안 건조하였다. 합성된 물질들의 결정성과 구조적 특성을 확인하기 위하여 X-ray diffraction spectroscopy(XRD)와 Field emission scanning electron microscopy(FE-SEM)을 사용하였다. 광 촉매 효과는 오염물질 대신 Rhodamin-B를 사용하여 UV 조사하에 암실에서 실험하였다. 광 촉매 효과는 UV-vis spectrometer를 이용하여 확인하였다. XRD 결과 순수한 ZnO가 합성된 것을 확인 하였다. FE-SEM을 통하여 시간이 지남에 따라 구 형태에서 막대형태를 지나 꽃 형태로 변하는 것을 확인 할 수 있었다. 광촉매 특성 결과 꽃 형태를 가진 ZnO NPs가 광 촉매 특성이 가장 우수한 것으로 확인 되었다.

NiCl2 첨착된 흡착제 상에서 암모니아의 흡착 및 재생 특성 (Adsorption and Regeneration Characteristics of Ammonia on NiCl2 Impregnated Adsorbents)

  • 임정현;송강;박주식;김영호
    • 공업화학
    • /
    • 제33권2호
    • /
    • pp.202-209
    • /
    • 2022
  • 암모니아에 대한 흡착 성능 향상을 목적으로 NiCl2 첨착에 적합한 지지체 및 NiCl2의 첨착량이 암모니아 흡착능에 미치는 영향을 연구하였다. NiCl2는 초음파 조사 하에서 여러 지지체의 표면 위로 첨착하였으며, NiCl2가 첨착된 흡착제의 물리화학적 특성 및 암모니아 흡착 성능을 관찰하였다. 다양한 지지체들 중, 가장 넓은 비표면적을 갖는 활성탄위로 NiCl2를 첨착했을 때, 암모니아의 흡착능이 가장 우수한 것으로 나타났다. 활성탄 위로 NiCl2의 첨착량을 변화시킨 결과, 2 mmol·g-1을 첨착한 NiCl2(2.0)/AC 흡착제가 5.977 mmol·g-1의 가장 우수한 암모니아 흡착 용량을 나타냈다. 또한 저온 열을 이용할 수 있는 조건하 5회의 반복 순환 시험에서 흡착 용량이 거의 일정한 수준으로 유지됨을 나타내어 흡착제의 재생 능력이 우수함을 알 수 있었다.