• Title/Summary/Keyword: Ultrasonic Intensity

검색결과 164건 처리시간 0.026초

표면 SH파 모드의 분산특성 해석과 그 응용 (A Study on the Application and Dispersion Characteristics Analysis of Surface SH-wave Mode)

  • 이상용;박익근;윤종학;노승남;안형근
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 춘계학술대회 논문집(한국공작기계학회)
    • /
    • pp.61-65
    • /
    • 2001
  • A new flaw detection technique using by SH angle beam method has been discussed. The SH-wave is horizontally polarized shear wave and the surface SH wave has a characteristic of traveling along near surface layer. The surface SH wave technique is valuable for the detection of fatigue cracks at fillet weld heels which cannot be detected by other ultrasonic technique such as angle beam technique and The dispersion curves of it has simple characterization. In this work, using these beneficial chraterization, quality evaluation of spot weld with ultrasonic sound intensity of SH-wave passing through nugget area of spot weld are verified experimentally.

  • PDF

Ultrasonic dissection versus electrocautery for immediate prosthetic breast reconstruction

  • Lee, Dongeun;Jung, Bok Ki;Roh, Tai Suk;Kim, Young Seok
    • Archives of Plastic Surgery
    • /
    • 제47권1호
    • /
    • pp.20-25
    • /
    • 2020
  • Background Ultrasonic dissection devices cause less thermal damage to the surrounding tissue than monopolar electrosurgical devices. We compared the effects of using an ultrasonic dissection device or an electrocautery device during prosthetic breast reconstruction on seroma development and short-term postoperative complications. Methods We retrospectively reviewed the medical records of patients who underwent implant-based reconstruction following mastectomy between March 2017 and September 2018. Mastectomy was performed by general surgeons and reconstruction by plastic surgeons. From March 2017 to January 2018, a monopolar electrosurgical device was used, and an ultrasonic dissection device was used thereafter. The other surgical methods were the same in both groups. Results The incidence of seroma was lower in the ultrasonic dissection device group than in the electrocautery group (11 [17.2%] vs. 18 [31.0%]; P=0.090). The duration of surgery, total drainage volume, duration of drainage, overall complication rate, surgical site infection rate, and flap necrosis rate were comparable between the groups. Multivariate analysis revealed that the risk of seroma development was significantly lower in the ultrasonic dissection device group than in the electrocautery group (odds ratio for electrocautery, 3.252; 95% confidence interval, 1.242-8.516; P=0.016). Conclusions The findings of this study suggest that the incidence of seroma can be reduced slightly by using an ultrasonic dissection device for prosthesis-based breast reconstruction. However, further randomized controlled studies are required to verify our results and to assess the cost-effectiveness of this technique.

저강도 초음파가 조골세포 활성에 미치는 영향 (The Effect of Low Intensity Ultrasound on Osteoblast Activation)

  • 홍성민;한승무;한은옥;임사비나;김창주
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권3호
    • /
    • pp.201-206
    • /
    • 2004
  • 뼈의 형성과 재형정은 조골세포에 의한 골기질의 합성과 파골세포에 의한 재흡수에 의해 조절된다. 최근에는 골형성세포의 활성화를 통한 골조직의 재생 및 치유에 대한 연구가 활발히 이루어지고 있다. 골형성 세포의 활성화는 생물학적 자극뿐만 아니라 물리적 자극에 의해서도 영향을 받는 것으로 알려져 있다. 본 연구에서는 물리적 자극 가운데에서 연구가 거의 되지 않은 저강도 초음파가 골형성 세포의 활성에 미치는 영향을 조사하였다. 이를 위하여 우선 다양한 특성의 초음파를 사용함으로써 세포활성에 미치는 최적의 초음파 조건을 결정하였다 본 연구 결과 전체 duty cycle에서 초음파 강도가 0.3W/$\textrm{cm}^2$일 경우가 세포활성에 가장 적합하며 duty cycle 50%인 경우 최고의 세포수 증가율을 나타내었다. 이와 같이 골조직의 재생에 적합한 초음파의 특성을 결정하여 골절 및 골다공증의 치료에 초음파를 활용할 수 있을 것으로 사료된다.

동심원관내에서 초음파가 가진된 유동특성의 PIV계측에 의한 연구 (A Study on Flow Characteristics with Ultrasonic Forcing in a Coaxial Circular Pipe by PIV Measurement)

  • 구자훈;박영호;최우창;송민근;주은선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.639-644
    • /
    • 2000
  • An experiment on the enhancement of turbulent flow with ultrasonic forcing was carried out by using PIV measurement in a coaxial circular pipe which could offer characteristics of the turbulence flow plentifully through its jet. A large transparent acryl tank and a coaxial circular pipe nozzle were made for the above research. city water of $25^{\circ}C$ was selected as an experimental liquid and the front flow field of the coaxial circular pipe was divided vertically as 3 measuring regions to observe characteristics of flow phenomena. characteristics of fluid flow such as velocity vector distribution, kinetic energy, turbulent intensity and etc. were visualized, observed, examined and considered at 5 kinds of Re No. such as $Re=1{\times}10^3,\;2{\times}10^3,\;3{\times}10^3,\;5{\times}10^3,\;1{\times}10^4$. In result it was proved that ultrasonic vibration affected the enhancement of turbulent flow.

  • PDF

가중계수법을 이용한 5회선 초음파 유량계의 유속적분방법의 불확도 평가 (Uncertainty Evaluation of Velocity Integration Method for 5-Chord Ultrasonic Flow Meter Using Weighting Factor Method)

  • 이호준;이권희;노석홍;황상윤;노영아
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.287-294
    • /
    • 2005
  • Flow rate measurement uncertainties of the ultrasonic flow meter are generally influenced by many different factors, such as Reynolds number, flow distortion, turbulence intensity, wall surface roughness, velocity integration method along the acoustic paths, and transducer installation method, etc. Of these influencing factors, one of the most important uncertainties comes from the velocity integration method. In the present study, a optimization weighting factor method for 5-chord, which is given by a function of the chord locations of acoustic paths, is employed to obtain the mean velocity in the flow through a pipe. The power law profile is assumed to model the axi-symmetric pipe flow and its results are compared with the present weighting factor concept. For an asymmetric pipe flow, the Salami flow model is applied to obtain the velocity profiles. These theoretical methods are also compared with the previous Gaussian, Chebyshev, and Tailor methods. The results obtained show that for the fully developed turbulent pipe flows with surface roughness effects, the present weighting factor method is much less sensitive than Chebyshev and Tailor methods, leading to a better reliability in flow rate measurement using the ultrasonic flow meters.

  • PDF

초음파트랜스듀서의 재질에 따른 실출력과 인체모사조직의 온열효과에 관한 연구 (A Study on the Actual Output and Thermal Effect in Tissue Mimicking Phantom by the Material of the Ultrasonic Transducer)

  • 유상현;최원재;이승원
    • 대한물리의학회지
    • /
    • 제10권1호
    • /
    • pp.91-97
    • /
    • 2015
  • PURPOSE: In this study investigated the thermal effect in tissue mimicking phantom by the material of the ultrasonic transducer in low intensity sonication. METHODS: The material of the ultrasonic transducer was made of ceramic, stainless steel, aluminum. Korea Testing Laboratory was measured of the three kinds of materials the total output of the ultrasonic transducer. Each material was measured core temperature and the actual output depending on the type of transducer. Agarose tissue mimicking phantom and silicone tissue mimicking phantom was made. Transducers made of three kinds of materials were emitted in the phantom. It is shown as a graph about time and temperature and the surface temperature rising speed and deep temperature rise rate was investigated. RESULTS: Ceramic transducers were highest output. Higher than the stainless steel transducer, aluminum had the lowest total output. Deep temperature was the highest in the ceramic transducer, and the surface temperature was the highest in the stainless steel transducer. Thermal images of ceramic transducer showed that a valid output is formed deeper wider than the metal. CONCLUSION: Ceramic transducer is confirmed the excellence than the metal transducer in deep thermal effect and the actual output of the ultrasound.

Optical Filter Design for Fluorescence Technique Based Phycocyanin Measurement Sensor Used In Water Treatment Plants

  • Mariappan, Vinayagam;Lee, Sung Hwa;Yang, Seungyoun;Kim, Jintae;Lee, Minwoo
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제10권2호
    • /
    • pp.45-50
    • /
    • 2018
  • Recently the water management department advised the water treatment industry to focus on deploy the chemical free and the environmentally responsible process to adopt on water treatment plants in every country. In this objective, water treatment process started using ultrasonic based phycocyanin extraction with fluorescence measurement techniques to detect the change in the yield of phycocyanin. This paper propose the design of optical filter model for fluorescence technique based immersive optical phycocyanin measurement sensor design. The proposed design uses the multi-wavelength sensor module for irradiating part, and this plays a role of removing a wavelength band other than 590 ~ 620 nm. The preliminary study on immersed phycocyanin sensor, the fluorescence value of picocyanin according to the ultrasonic intensity, treatment time and number of cells was measured using JM phycocyanin module to emulate the proposed design, and were compared performance of the proposed sensor emulation. In this design, the phycocyanin fluorescence value increased about 2.1 ~ 4.7 times as the ultrasonic treatment time increased as compared with JM phycocyanin module, and the phycocyanin fluorescence value within the analysis range was obtained by ultrasonic treatment within one minute.

산화철 합성에 미치는 침전제와 초음파의 영향 (Influence of the Precipitation Medium and Ultrasonic Wave on the Synthesis of Iron Oxide)

  • 임종호;김태현;이승원
    • 한국재료학회지
    • /
    • 제16권11호
    • /
    • pp.687-691
    • /
    • 2006
  • Synthesis of Iron oxides by air oxidation of $FeSO_4$ solutions in the presence of NaOH, Diethylenetriamine (DETA), Butylamine (BA) and influence of ultrasonic wave were investigated by XRD, SEM and particle size analyzer. As the DETA addition increased to 0.05 mol, $Fe_3O_4$ was formed with goethite($\alpha$- FeOOH) and $Fe_3O_4$ single phase was formed above 0.18mol of DETA. As the BA addition increased, the XRD peak intensity of (020) face of lepidocrocite($\gamma$-FeOOH) was developed until the formation of $Fe_3O_4$ and reduced the size of the iron oxide particles formed. Ultrasonic wave reduced the size of the iron oxide particles but gave little effects on the iron oxide particles synthesized by amine.

미용 치료 헬스케어를 위한 고강도 집속 초음파 장치 개발 연구 (A Study on the Development of High-intensity focused Ultrasound Device for the Beauty Treatment Health Care)

  • 이우철;고윤석
    • 한국전자통신학회논문지
    • /
    • 제11권12호
    • /
    • pp.1259-1264
    • /
    • 2016
  • 초음파 치료는 회복속도가 빠르고 안전하다는 이유로 피부거상치료와 관련된 미용분야에서 큰 관심을 받고 있다. 본 연구에서는 미용치료를 위한 고강도 집속 초음파 장치의 출력회로를 개발하였다, 고강도 집속 초음파 시스템의 미용치료분야에 대한 적용 가능성을 확인하기 위해 수중 청음기를 이용하여 3 차원 초음파 강도 에너지를 측정 분석하였다, 고강도 집속 초음파장치에 의해 미용 치료에 유용함을 확인하였다.