• Title/Summary/Keyword: Ultrasonic Intensity

Search Result 164, Processing Time 0.03 seconds

Design and Implementation of LED Dimming System with Intelligent Sensor Module

  • Cho, Young Seek;Kwon, Jaerock;Kim, Hwan-Yong
    • Journal of information and communication convergence engineering
    • /
    • v.11 no.4
    • /
    • pp.247-252
    • /
    • 2013
  • An intelligent light emitting diode (LED) dimming system is designed and implemented for energy-saving lighting systems. An LED light bulb is powered by an LED driver controlled by a microcontroller using pulse width modulation (PWM) signals. By changing the duty cycle of the PWM signals, the LED driver generates a driving current of up to 1,000 mA. The current consumption by the LED light bulb exhibits a very linear characteristic that indicates that the level of LED dimming can be finely tuned. Multiple sensors-lighting intensity and ultrasonic range sensors-are combined with the LED dimming system to realize an automatically controllable LED lighting system. The light intensity sensor is capable of sensing ambient light. The ultrasonic range sensor can detect objects from 0.15 to 5.6 m at a resolution of 0.0254 m. The collected information by the light intensity and ultrasonic range sensors is processed by the microcontroller that in turn automatically controls the brightness of the LED light bulb. The algorithm of the software for the LED dimming system is also described.

Treatment of decomposition of Aqueous 2,4-Dichlorophenol Solution by Ultrasonic Irradiation (초음파 검사에 의한 수중의 2,4-Dichlorophenol 분해처리)

  • 손종렬;문경환;김영환;우완기
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.3
    • /
    • pp.54-62
    • /
    • 1999
  • 2,4-Dichlorophenol was known pollutants caused by the endocrine disruptor into the refractory substances of environment and this is difficult to be degradable by conventional methods. Therefore, a considerable interest has been devoted to developing new process where 2,4-Dichlorophenol can easily decomposed. In this study, the series of ultrasonic irradiation for removal of 2,4-Dichlorophenol has been selected as a model reaction in the batch reactor system in order to obtain the basic data investigate the influence of various experimental parameters such as concentration, pH, reaction temperature, acoustic intensity. The products obtained form the ultrasonic irradiation were analysed by GC/MS and HPLC. The formation of $H_2O_2$, a well-known the strong oxidant was found proportionally to increase with irradiation time. The intermediates of ultrasonic irradiation of 2,4-Dichlorophenol were identified as HCl, catechol, hydroquinone, o,p-benzoquinone, muconic acid, and maleic acid. The final products of this was $CO_2$ and $H_2O$. As the decomposition of 2,4-Dichlorophenol proceeds by the ultrasonic irradiation, the pH of 2,4-Dichlorophenol containing aqueous solution increases slowly, The decomposition of 2,4-Dichlorophenol was found to be occured fast in the basic medium. In general, the rate of reaction is proportional to the reaction temperature obeying the Arrhenius' law. However, in the ultrasonic irradiation, this suggests as the reaction temperature increase the decomposition rate of the reactant decreases. This result meant that the increase of reaction temperature due to the increase of vapor pressure of water accelerated the decrease of acoustic intensity which was can be proportional to the decomposition rae of these compounds. It was found that more than 80% of phenol solution was removed within hours in all reaction conditions. The reaction order in the degradation of the 2,4-Dichlorophenol compounds was verified as the Pseude-first order. From the fore-mentioned results, it can be concluded that the refractory organic compounds caused by endocrine disruptor as 2,4-dichlorophenol could be removed by the ultrasonic irradiation with radicals, such as $H{\;}{\cdot}{\;}and{\;}OH{\;}{\cdot}$ radical causing the high increase of pressure and temperature. Finally, it apeared that the technology using ultrasonic irradiation can be applied to the treatment of refractory substances caused by endocrine disruptor which are difficult to be decomposed by the conventional methods.

  • PDF

The Synthesis of (Y,Gd)$BO_3:Eu^{3+}$Phosphor by Ultrasonic Spray and Their Photoluminance Properties (초음파 분무에 의한 (Y,Gd)$BO_3:Eu^{3+}$ 형광체의 제조와 이의 발광 특성)

  • 김대수;김성우;이임렬
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.107-110
    • /
    • 1999
  • The ultrasonic spray method was employed to make (Y,Gd)BO$_3$:Eu Phosphor, and its optical properties under 147nm VUV and 254 nm UV excitations were characterized and then compared with that produced by the solid-state reaction. The mixed solution of acetate hydrates of Y, Gd, Eu and boric acid diluted in water or methanol was used as the precursor fur the spray. It was found that (Y,Gd)BO$_3$:Eu phosphor made by this ultrasonic spray had a spherical shape and fine particle size of 1${\mu}{\textrm}{m}$. The crystalline structure for the as-sprayed phosphor was amorphous, but it converted into the same polycrystalline phase of solid state reaction after post heat treatment at 110$0^{\circ}C$ for 2hr. The emitting intensity under VUV and UV excitations for the spray-formed (Y,Gd)BO$_3$:Eu phosphor, however, was inferior to the later one. The excitation spectra were also studied and compared under VUV and UV excitations to explain the change of emitting intensity with Gd substitution in (Y$_{1-x}$ Gd$_{x}$)BO$_3$:Eu Phosphors made by spray and solid state reaction.on.

  • PDF

Process of pulsations of the spherical cavity in a liquid under the influence of ultrasonic vibrations

  • Kuznetsova, Elena L.;Starovoitov, Eduard I.;Vakhneev, Sergey;Kutina, Elena V.
    • Advances in aircraft and spacecraft science
    • /
    • v.9 no.2
    • /
    • pp.95-102
    • /
    • 2022
  • The paper investigates the process of pulsation of a spherical cavity (bubble) in a liquid under the influence of a source of ultrasonic vibrations. The process of pulsation of a cavitation pocket in liquid is investigated. The Kirkwood-Bethe model was used to describe the motion. A numerical solution algorithm based on the Runge-Kutta-Felberg method of 4-5th order with adaptive selection of the integration step has been developed and implemented. It was revealed that if the initial bubble radius exceeds a certain value, then the bubble will perform several pulsations until the moment of collapse. The same applies to the case of exceeding the amplitude of ultrasonic vibrations of a certain value. The proposed algorithm makes it possible to fully describe the process of cavitation pulsations, to carry out comprehensive parametric studies and to evaluate the influence of various process parameters on the intensity of cavitation.

Analysis on the cascade high power piezoelectric ultrasonic transducers

  • Lin, Shuyu;Xu, Jie
    • Smart Structures and Systems
    • /
    • v.21 no.2
    • /
    • pp.151-161
    • /
    • 2018
  • A new type of cascade sandwiched piezoelectric ultrasonic transducer is presented and studied. The cascade transducer is composed of two traditional longitudinally sandwiched piezoelectric transducers, which are connected together in series mechanically and in parallel electrically. Based on the analytical method, the electromechanical equivalent circuit of the cascade transducer is derived and the resonance/anti-resonance frequency equations are obtained. The impedance characteristics and the vibrational modes of the transducer are analyzed. By means of numerical method, the dependency of the resonance/anti-resonance frequency and the effective electromechanical coupling coefficient on the geometrical dimensions of the cascade transducer are studied and some interesting conclusions are obtained. Two prototypes of the cascade transducers are designed and made; the resonance/anti-resonance frequency is measured. It is shown that the analytical resonance/anti-resonance frequencies are in good agreement with the experimental results. It is expected that this kind of cascade transducer can be used in large power and high intensity ultrasonic applications, such as ultrasonic liquid processing, ultrasonic metal machining and ultrasonic welding and soldering.

Measurement of sonoluminescence intensity for evaluation of the amount of radical generated by ultrasonic cavitation (초음파 캐비테이션에 의해 생성되는 라디칼의 발생량 평가를 위한 소노루미네센스 발광강도의 측정)

  • Jungsoon Kim;Moojoon Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.1
    • /
    • pp.50-56
    • /
    • 2023
  • The hydroxyl radical (·OH) and superoxide anion radical (·O2- ) generated by the shock wave generated during ultrasonic cavitation collapse in TiO2 suspension are highly useful because they can sterilize and disinfect. For practical use as a sterilization method without any chemicals, in this study, we proposed a method for evaluating the generation of radicals generated by high-intensity ultrasound emitted to titanium dioxide suspension. In the proposed method, the sonoluminescence phenomenon, which emits light by ultrasonic cavitation decay energy, was utilized, and the degree of radical generation was evaluated through the amount of light energy by sonoluminescence. As a result, even at a low concentration of titanium dioxide of 0.02 wt%, light energy 5 times higher than in the absence of titanium dioxide was received. After that, as the concentration increased by 0.1 wt%, the luminous intensity of sonoluminescence increased linearly by about 14.8 × 10-12 lm. Therefore, it was confirmed that the radicals generated by radiating high-intensity ultrasound to the titanium dioxide suspension increased linearly as the concentration of titanium dioxide increased within a given concentration range.

Quantitative Nondestructive Evaluation of Bonded Joints utilizing Pulse-Echo Ultrasonic Test (펄스-에코법을 이용한 접착접합 시험편의 정량적 비파괴 평가)

  • Oh, Seung-Kyu;Hwang, Young-Taek;Lee, Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.3
    • /
    • pp.157-164
    • /
    • 2003
  • The pulse-echo method is one of the most widely used ultrasonic techniques for application of nondestructive evaluation. Particularly, quantitative nondestructive evaluation of defects has been considered more important to assure the reliability and the safety of structure. Frequency energy in adhesive joints is based on the ultrasonic wave analysis. The attenuation coefficient upon wave amplitude and the frequency energy that is expressed in the term of wave pressure amplitude were utilized for the primary wave experiment. By means of a control experiment, it was confirmed that the variation of the frequency energy in adhesive joints depends on transition by stress variation. In this paper, the ultrasonic characteristics were measured for single lap joint and Double Cantilever Beam specimen with different fracture modes that was subjected to stress. Consequently, the data that was obtained from the adhesive specimen was analytically compared to the fracture mechanics parameter

Heating Characteristics Evaluation of Superposed Sonication Using Glycerol Tissue Mimic Phantom (글리세롤 조직유사 팬텀을 이용한 초음파 중첩 조사에 따른 가열 특성 평가)

  • Noh, Si-Cheol;Kang, Sang-Sik;Park, Ji-Koon;Kim, Ju-Young;Jung, Bong-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.523-528
    • /
    • 2015
  • In this study, we evaluated the heating characteristics of single sonication and superposed two low-intensity ultrasonic sonication. Compare the results, the superposed sonication was showed a superior thermal effect than single sonication. And the maximum temperature was increased as 120-150%. The starting time of temperature rising has been shortened in superposed sonication. In addition, the time up to the maximum temperature has been shortened, too. In generally, as the ultrasonic intensity is higher, the more surface damage is occurred. However, in the case of superposed sonication, the same thermal effect had be confirmed without surface damage. Through the results of the study, we thought that the superposed sonication will be able to reduce the intensity of the ultrasonic treatment. And, by using the low-intensity, the more safe and more effect therapy will be possible in therapeutic ultrasound application.

Development of Ultrasonic Transducer System for Wireless Power Transfer Part 1 : Transmitter Development (무선 전력전송을 위한 초음파 트랜스듀서 시스템 개발 Part 1: 송신소자 개발)

  • Youm, Woo-Sub;Hwang, Gunn;Yang, Woo-Seok;Lee, Sung-Q
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.9
    • /
    • pp.845-852
    • /
    • 2012
  • Recently, wireless power transfer technology is ready to be commercialized in consumer electronics. It draws attention from not only experts but also public because of its convenience and huge market. However, previous technologies such as magnetic resonance and induction coupling have limited applications because of its short transfer distance compared to device size and magnetic intensity limitation on the safety of body exposure. As an alternative, ultrasonic wireless power transfer technology is proposed. The ultrasonic wireless power transfer system is composed of transmitter which converts electrical energy to ultrasonic energy and receiver which converts the ultrasonic energy to the electrical energy again. This paper is focused on the development of high energy conversion efficiency of ultrasonic transmitter. Optimal transfer frequency is calculated based on the acoustic radiation and damping effect. The transmitter is designed through numerical analysis, and is manufactured to match the optimal transfer frequency with the size of 100 mm diameter, 12.2 mm thickness plate. The energy conversion efficiency of about 13.6 % at 2 m distance is obtained, experimentally. This result is quite high considered with the device size and the power transfering distance.

Development of ultrasonic transducer system for wireless power transfer Part 1: Transmitter development (무선 전력전송을 위한 초음파 트랜스듀서 시스템 개발 Part 1: 송신소자 개발)

  • Youm, Woo-Sub;Hwang, Gunn;Lee, Sung-Q
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.771-776
    • /
    • 2012
  • Recently, wireless power transfer technology is ready to be commercialized in consumer electronics. It draws attention of not only experts but also public because of its convenience and huge market. However, previous technologies such as magnetic resonance and induction coupling have limited applications because of its short transfer distance compared to device size and magnetic intensity limitation for the safety of body exposure. As an alternative, ultrasonic wireless power transfer technology is proposed. The ultrasonic wireless power transfer system is composed of transmitter which converts electrical energy to ultrasonic energy and receiver which converts the ultrasonic energy to the electrical energy again. This paper is focused on the development of high energy conversion efficiency of ultrasonic transmitter. Optimal transfer frequency is calculated based on the acoustic radiation and damping effect. The transmitter is designed through numerical analysis, and is manufactured to match the optimal transfer frequency with the size of 100mm diameter, 12.2 mm thickness plate. The energy conversion efficiency of about 13.6% at 2m distance is obtained, experimentally. This result is quite high considered with the device size and the power transfer distance.

  • PDF