• Title/Summary/Keyword: Ultra-low Head

Search Result 19, Processing Time 0.026 seconds

Sliding Wear Behavior of UHMWPE against Novel Low Temperature Degradation-Free Zirconia/Alumina Composite

  • Lee, K.Y.;Lee, M.H.;Lee, Y.H.;Seo, W.S.;Kim, D.J.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.365-366
    • /
    • 2002
  • The sliding wear behavior of ultra high molecular weight polyethylene (UHMWPE) was examined on a novel low temperature degradation-free zirconia/alumina composite material and conventional alumina and zirconia ceramics used for femoral head in total hip joint replacement. The wear of UHMWPE pins against these ceramic disks was evaluated by performing linear reciprocal sliding and repeat pass rotational sliding tests for one million cycles in bovine serum. The weight loss of polyethylene against the novel low temperature degradation-free zirconia/alumina composite disks was much less than those against conventional ceramics for all tests. The mean weight loss of the polyethylene pins was more io the linear reciprocal sliding test than in the repeal pass rotational sliding lest for all kinds of disk materials. Neither the coherent transfer film nor the surface damage was observed on the surface of the novel zirconia/alumina composite disks during the test. The observed r,'stilts indicated that the wear of the polyethylene was closely related to contacting materials and kinematic motions. In conclusion, the novel zirconia/alumina composite leads the least wear of polyethylene among the tested ceramics and demonstrates the potential as lhe alternative materials for femoral head in total hip joint replacement.

  • PDF

Dynamic analysis of magnetic head slider at ultra low clearance (마그네틱 헤드 슬라이더의 극소 공기막에 대한 동특성 해석)

  • 장인배;한동철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.6
    • /
    • pp.1487-1494
    • /
    • 1990
  • In this paper the dynamic characteristics of self acting air lubricated slider bearing of hard disk/head system are investigated. The dynamic equations of magnetic head mechanism considering both parallel and pitch motion and the time dependent modified Reynolds equation are analyzed and the dynamic pressure distribution of air film is numerically calculated in frequency domain by small perturbation method and finite difference scheme with variable grid. The dynamic response of the slider spacing is obtained accordingly as the moving recording surface vibrates in parallel mode.

Servo Track Writing for Ultra-High TPI Disk Drive in Low Density Medium Condition (초고밀도 디스크 드라이브를 위한 저밀도 작동 환경에서 서보 트랙 기록 방법에 대한 연구)

  • 한윤식;김철순;강성우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.736-741
    • /
    • 2004
  • In high-capacity disk drives with ever-growing track density, the allowable level of position error signal (PES) is becoming smaller and smaller. In order to achieve the high TPI disk drive, it is necessary to improve the writing accuracy during the STW(servo track writing) process through the reduction of TMR sources. Among the main contributors of the NRRO(Non-Repeatable Run-out) PES, the disk vibration and the HSA(head-stack assembly) vibration is considered to be one of the most significant factors. Also the most contributors of RRO(Repeatable Run- out) come from the contributors of NRRO which is written-in at the time of STW(servo track writing) process. In this paper, the experimental test result shows that the effect of NRRO on servo written-in RRO effectively can be reduced through a STW process under low dense medium condition such as semi-vacuum.

  • PDF

A Study on DOE Method to Optimize the Process Parameters for Cu CMP (구리 CMP 공정변수 최적화를 위한 실험계획법(DOE) 연구)

  • Choi, Min-Ho;Kim, Nam-Hoon;Kim, Sang-Yong;Chang, Eui-Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.1
    • /
    • pp.24-29
    • /
    • 2005
  • Chemical mechanical polishing (CMP) has been widely accepted for the global planarization of multi-layer structures in semiconductor manufacturing. Copper has been the candidate metallization material for ultra-large scale integrated circuits (ULSIs), owing to its excellent electro-migration resistance and low electrical resistance. However, it still has various problems in copper CMP process. Thus, it is important to understand the effect of the process variables such as turntable speed, head speed, down force and back pressure are very important parameters that must be carefully formulated in order to achieve desired the removal rates and non-uniformity. Using a design of experiment (DOE) approach, this study was performed investigating the main effect of the variables and the interaction between the various parameters during CMP. A better understanding of the interaction behavior between the various parameters and the effect on removal rate, non-uniformity and ETC (edge to center) is achieved by using the statistical analysis techniques. In the experimental tests, the optimum parameters which were derived from the statistical analysis could be found for higher removal rate and lower non-uniformity through the above DOE results.

SLIDERS FOR THE NEXT GENERATION MAGNETIC HARD DISK DRIVE SYSTEMS-NUMERICAL SIMULATION

  • Jhon, Myung-S.;Peck, Paul-R.;Kang, Soo-Choon;Wang, Benjamin-L.;Kim, In-Eung;Park, Ki-Ook
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.695-701
    • /
    • 1995
  • Fundamental issues and general procedures of modeling the head disk interface (HDI) in order to provide design criteria for future ultra-low flying sliders are given. Intermittent contact and gaseous rarefaction effects are discussed using nonconventional kinetic theory. To illustrate the simulation results, we modeled IBM 3370 taper flat sliders and positive/negative "bow tie" sliders. Several alternative HDI concepts for future disk drives - viscoelastic bearings, a hybrid system, and contact recording - are also briefly discussed.

  • PDF

A Study of Optical Characteristics for Biodiesel and Diesel Smoke Particles and Measuring their Dimensionless Light Extinction Constants (바이오디젤과 디젤 연기입자의 광학특성 및 무차원 광소멸계수 측정에 관한 연구)

  • Choi, Seuk-Cheun;Jang, Yeong-Seok;Park, Seul-Hyun;Kim, Youn-Kyu
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.37-42
    • /
    • 2016
  • The dimensionless extinction constants of smoke particles produced from burning of soy methyl ester (B100) biodiesel and ultra low sulfur diesel (ULSD) fuels were measured. To this end, optical measurements of smoke volume fraction with the aid of a He-Ne laser at 633 nm were compared to the simultaneous gravimetric measurements. The average value of measured dimensionless extinction constants at 633 nm was 11.8 for biodiesel smoke particles and 11.1 for diesel smoke particles, respectively whose values are very comparable withing the range of measurement uncertainty (${\pm}10.1%$). The analysis of Raman spectroscopy revealed that overall characteristics of light extinction between particles produced from each fuel may differ from each other.

Evaluation of the Lens Absorbed Dose of MVCT and kV-CBCT Use for IMRT to the Nasopharyngeal Cancer Patient (비인두암 환자에 대한 세기조절 방사선치료 시 이용되는 MVCT와 kV-CBCT의 수정체 흡수선량 평가)

  • Choi, Jae Won;Kim, Cheol Chong;Park, Su Yeon;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.131-136
    • /
    • 2013
  • Purpose: Quantitative comparative evaluation of the difference in eye lens absorbed dose when measured by MVCT and kV-CBCT, though such a dose was not included in the original IMRT treatment plan for the nasopharyngeal cancer patient. Materials and Methods: We used CT (Lightspeed Ultra 16, General Electric, USA) against an Anderson rando phantom (Alderson Research Laboratories Inc, USA) and established the plan for tomotherapy treatment (Tomotherapy, Inc, USA) and linear accelerator treatment (Pinnacle 8.0, Philips Medicle System) for the achieved CT images on the same condition with the nasopharyngeal cancer patient treatment plan. Then, align the ther-moluminescence dosimeter (TLD100 Harshaw, USA) with the eye lens, shot the lens with Tomotherapy MVCT under 3 conditions (Fine, Normal, and Coarse), and shot both lenses with kV-CBCT under 2 conditions (Low Dose Head and Standard Dose Head) 3 times each. Results: When we analyzed the eye lens absorbed dose according to MVCT and kV-CBCT images by using both Tomotherapy and Pinacle 8.0, we achieved the following result; According to Tomotherapy MVCT, RT 0.8257 cGy in the Coarse mode, LT 0.8137 cGy, RT 1.089 cGy and LT 1.188 cGy in the Normal mode, and RT 2.154 cGy and LT 2.082 cGy in the Fine mode. According to Pinacle 8.0 kV-CBCT, RT 0.2875 cGy and LT 0.1676 cGy in the Standard Dose mode and RT 0.1648 cGy and LT 0.1212 cGy in the Low-Dose mode. In short, the MVCT result was significantly different from that of kV-CBCT, up to 20 times. Conclusion: We think kV-CBCT is more effective for reducing the amount of radiation which a patient is receiving during intensity modulated radiation treatment for other purposes than treatment than MVCT, when we consider the absorbed dose only from the viewpoint of image-guided radiation therapy. Besides, we understood the amount of radiation is too sensitive to the shooting condition, even when we use the same equipment.

  • PDF

Repeatable Run-out Reduction by Servo Track Writing in Semi-vacuum Condition for Ultra-high TPI Disk Drive (초고밀도 디스크 드라이브를 위한 반 진공 작동 환경에서 서보 트랙 기록 방법에 의한 RRO 저감에 대한 연구)

  • 한윤식;강심우
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.11
    • /
    • pp.1176-1181
    • /
    • 2004
  • In high-capacity disk drives with ever-growing track density, the allowable level of position error signal(PES) is becoming smaller and smaller. In order to achieve the high TPI(track per inch) disk drive, it is necessary to improve the writing accuracy during the servo track writing(STW) Process through the reduction of track mis-registration sources. Among the main contributors of the non-repeatable runout(NRRO) PES, the disk vibration and the head-stack assembly vibration is considered to be one of the most significant factors. Also the most contributors of repeatable runout(RRO) come from the contributors of NRRO which is written-in at the time of STW process. In this paper, the effect of NRRO on servo written-in RRO is Investigated by experimentally, and the experimental result shows that the written-in RRO can be effectively reduced through a STW process under low dense medium condition such as semi-vacuum.

EFFECTS OF TITANIUM SURFACE COATING ON CERAMIC ADHESION (타이타늄 표면 코팅이 도재 결합에 미치는 영향)

  • Kim, Yeon-Mi;Kim, Hyun-Seung;Lee, Kwang-Min;Lee, Doh-Jae;Oh, Gye-Jeong;Lim, Hyun-Pil;Seo, Yoon-Jung;Park, Sang-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.601-610
    • /
    • 2007
  • Statement of problem: The adhesion between titanium and ceramic is less optimal than conventional metal-ceramic bonding, due to reaction layer form on cast titanium surface during porcelain firing. Purpose: This study characterized the effect of titanium-ceramic adhesion after gold and TiN coating on cast and wrought titanium substrates. Material and method: Six groups of ASTM grade II commercially pure titanium and cast titanium specimens$(13mm{\times}13mm{\times}1mm)$ were prepared(n=8). The conventional Au-Pd-In alloy served as the control. All specimens were sandblasted with $110{\mu}m\;Al_2O_3$ particles and ultrasonically cleaned for 5min in deionized water and dried in air before porcelain firing. An ultra-low-fusing dental porcelain (Vita Titankeramik) was fused on titanium surfaces. Porcelain was debonded by a biaxial flexure test at a cross head speed of 0.25mm/min. The excellent titanium-ceramic adherence was exhibited by the presence of a dentin porcelain layer on the specimen surface after the biaxial flexure test. Area fraction of adherent porcelain (AFAP) was determined by SEM/EDS. Numerical results were statistically analyzed by one-way ANOVA and Student-Newman-Keuls test at ${\alpha}=0.05$. Results: The AFAP value of cast titanium was greatest in the group 2 with TiN coating, followed by group 1 with Au coating and the group 3 with $Al_2O_3$ sandblasting. Significant statistical difference was found between the group 1, 2 and the group 3 (p<.05). The AFAP value of wrought titanium was greatest in the group 5 with TiN coating, followed by the group 4 with Au coating and the group 6 with $Al_2O_3$ sandblasting. Conclusion: No significant difference was observed among the three groups (p>.05). The AFAP values of the cast titanium and the wrought titanium were similar. However the group treated with $Al_2O_3$ sandblasting showed significantly lower value (p<.05).