• 제목/요약/키워드: Ultimate strain

검색결과 597건 처리시간 0.024초

성토지반에 타입된 H형강 말뚝의 지지거동 (Bearing Capacity of Driven H-Piles in Embankment)

  • 박영호;정경자;김성환;유성근;이재혁;박종면
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.173-182
    • /
    • 2000
  • To find axial and lateral responses of impact-driven H piles in embankment(SM), the H piles are instrumented with electric strain gages, dynamic load test is performed during driving, and then the damage of strain gages is checked simultaneously. Axially and laterally static load tests are performed on the same piles after one to nine days as well. Then load-settlement behavior is measured. Furthermore, to find the set-up effect in H pile, No. 4, 16, 26, and R6 piles are restriked about 1, 2, and 14 days after driving. As results, ram height and pile capacity obtained from impact driving control method become 80cm and 210.3∼242.3ton, respectively. At 15 days after driving, allowable bearing capacity by CAPWAP analysis, which 2.5 of the factor of safety is applied for ultimate bearing capacity, increases 10.8%. Ultimate bearing capacity obtained from axially static load test is 306∼338ton. This capacity is 68.5∼75.7% at yield force of pile material and is 4∼4.5 times of design load. Allowable bearing capacity using 2 of the factor of safety is 153∼169ton. Initial stiffness response of the pile is 27.5ton/mm. As the lateral load increases, the horizontal load-settlement behaves linearly to which the lateral load reaches up to 17ton. This reason is filled with sand in the cavity formed between flange and web during pile driving. As the result of reading with electric strain gages, flange material of pile is yielded at 19ton in horizontal load. Thus allowable load of this pile material is 9.5ton when the factor of safety is 2.0. Allowable lateral displacement of this pile corresponding to this load is 23∼36mm in embankment.

  • PDF

내부 강관 보강 원형 R.C 기둥의 연성 거동 특성 (Ductility of Circular Hollow Reinforced Concrete Piers Internally Confined by a Steel Tube)

  • 한택희;한상윤;한금호;강영종
    • 한국방재학회 논문집
    • /
    • 제3권2호
    • /
    • pp.127-137
    • /
    • 2003
  • 구조적으로 콘크리트의 자중이 문제 시 되는 곳이나, 콘크리트의 재료비가 높은 경우, 수직부재로 중공 콘크리트의 사용이 경제적일 수 있다. 콘크리트의 구속효과를 발휘를 위해 외측 면을 띠철근으로 보강하고 내측 면에 강관을 삽입하여 보강한 원형 중공 콘크리트 기둥의 연성 거동에 관해 연구하였고, 압축강도와 콘크리트의 극한변형율을 증가시키는 구속력의 효과를 나타낸 Mander의 응력-변형률 관계를 사용하여, 모멘트-곡률 관계 해석을 유도하였다. 극한변형율에 영향을 주는 인자인 구속력을 발휘하는 철근의 철근비와 항복응력, 구속 콘크리트의 압축강도 등을 극한변형율과 횡철근비의 관계를 통하여, 강관 삽입된 원형 중공 철근콘크리트 기둥의 구속응력과 횡철근비의 관계식을 제안하였다. 제안된 횡철근비 관계식은 실험을 통하여 검증하였다.

Strengthening of steel-concrete composite beams with composite slab

  • Subhani, Mahbube;Kabir, Muhammad Ikramul;Al-Amer, Riyadh
    • Steel and Composite Structures
    • /
    • 제34권1호
    • /
    • pp.91-105
    • /
    • 2020
  • Steel-concrete composite beam with profiled steel sheet has gained its popularity in the last two decades. Due to the ageing of these structures, retrofitting in terms of flexural strength is necessary to ensure that the aged structures can carry the increased traffic load throughout their design life. The steel ribs, which presented in the profiled steel deck, limit the use of shear connectors. This leads to a poor degree of composite action between the concrete slab and steel beam compared to the solid slab situation. As a result, the shear connectors that connects the slab and beam will be subjected to higher shear stress which may also require strengthening to increase the load carrying capacity of an existing composite structure. While most of the available studies focus on the strengthening of longitudinal shear and flexural strength separately, the present work investigates the effect of both flexural and longitudinal shear strengthening of steel-concrete composite beam with composite slab in terms of failure modes, ultimate load carrying capacity, ductility, end-slip, strain profile and interface differential strain. The flexural strengthening was conducted using carbon fibre reinforced polymer (CFRP) or steel plate on the soffit of the steel I-beam, while longitudinal shear capacity was enhanced using post-installed high strength bolts. Moreover, a combination of both the longitudinal shear and flexural strengthening techniques was also implemented (hybrid strengthening). It is concluded that hybrid strengthening improved the ultimate load carrying capacity and reduce slip and interface differential strain that lead to improved composite action. However, hybrid strengthening resulted in brittle failure mode that decreased ductility of the beam.

음향방출법을 응용한 복합재 날개 구조물의 정적구조 건전성 평가 (Evaluation of Static Structural Integrity for Composites Wing Structure by Acoustic Emission Technique)

  • 전준탁;이영신
    • 한국항공우주학회지
    • /
    • 제37권8호
    • /
    • pp.780-788
    • /
    • 2009
  • 복합재 날개 구조물에 대한 구조 건전성 및 손상을 평가하기 위하여 정적 구조강도시험에 음향방출(AE)법이 응용되었다. 시험중 스트레인과 변위측정기법을 통하여 정적구조강도를 확인하였고, 음향방출요소 분석과 위치표정기법을 통하여 구조물의 내부 손상을 평가하고 손상위치를 찾을 수 있었다. 시험은 설계제한하중시험, 2차에 걸친 설계극한 하중시험, 파단시험이 수행되었다. 주요한 AE신호는 front lug근처의 표면에 부착된 센서에 의하여 감지되었다. 특히 1차 설계극한하중시험에서 스트레인 및 변위결과는 내부 손상을 보이지 않았으나 AE신호는 내부 손상이 이미 형성된 현상을 나타내었다. 파단시험에서는 AE활성도가 매우 활발하였고, 스트레인 및 변위의 결과는 심한 손상에 의하여 하중경로가 바뀌는 경향을 나타내었다. 음향방출법을 적용하여 정적 구조시험이 진행되는 동안 내부손상이 발생되는 하중과 위치를 정확하게 평가할 수 있었다. 본 연구로부터 음향방출법은 정적 구조강도시험에 있어 내부 손상을 평가하는데 유용한 기법임이 확인되었다.

Estimation of the load-deformation responses of flanged reinforced concrete shear walls

  • Wang, Bin;Shi, Qing-Xuan;Cai, Wen-Zhe;Peng, YI-Gong
    • Structural Engineering and Mechanics
    • /
    • 제73권5호
    • /
    • pp.529-542
    • /
    • 2020
  • As limited well-documented experimental data are available for assessing the attributes of different deformation components of flanged walls, few appropriate models have been established for predicting the inelastic responses of flanged walls, especially those of asymmetrical flanged walls. This study presents the experimental results for three large-scale T-shaped reinforced concrete walls and examines the variations in the flexural, shear, and sliding components of deformation with the total deformation over the entire loading process. Based on the observed deformation behavior, a simple model based on moment-curvature analysis is established to estimate flexural deformations, in which the changes in plastic hinge length are considered and the deformations due to strain penetration are modeled individually. Based on the similar gross shapes of the curvature and shear strain distributions over the wall height, a proportional relationship is established between shear displacement and flexural rotation. By integrating the deformations due to flexure, shear, and strain penetration, a new load-deformation analytical model is proposed for flexure-dominant flanged walls. The proposed model provides engineers with a simple, accurate modeling tool appropriate for routine design work that can be applied to flexural walls with arbitrary sections and is capable of determining displacements at any position over the wall height. By further simplifying the analytical model, a simple procedure for estimating the ultimate displacement capacity of flanged walls is proposed, which will be valuable for performance-based seismic designs and seismic capacity evaluations.

Statistical bias indicators for the long-term displacement of steel-concrete composite beams

  • Moreno, Julian A.;Tamayo, Jorge L.P.;Morsch, Inacio B.;Miranda, Marcela P.;Reginato, Lucas H.
    • Computers and Concrete
    • /
    • 제24권4호
    • /
    • pp.379-397
    • /
    • 2019
  • Steel-concrete composite beams are widely employed in constructions and their performance at the serviceability stage is of concern among practitioners and design regulations. In this context, an accurate evaluation of long-term deflections via various rheological concrete models is needed. In this work, the performance and predict capability of some concrete creep and shrinkage models ACI, CEB, B3, FIB and GL2000 are ascertained, and compared by using statistical bias indicators. Ten steel-concrete composite beams with existing experimental and numerical results are then modeled for this purpose. The proposed modeling technique uses the finite element method, where the concrete slab and steel beam are modeled with shell finite elements. Concrete is considered as an aging viscoelastic material and cracking is treated with the common smeared approach. The results show that when the experimental ultimate shrinkage strain is used for calibration, all studied rheological models predict nearly similar deflections, which agree with the experimental data. In contrast, significance differences are encountered for some models, when none calibration is made prior to. A value between twenty and thirty times the cracking strain is recommended for the ultimate tensile strain in the tension stiffening model. Also, increasing the relative humidity and decreasing the ambient temperature can lead to a substantial reduction of slab cracking for beams under negative flexure. Finally, there is not a unique rheological model that clearly excels in all scenarios.

Behavior of polygonal concrete-filled steel tubular stub columns under axial loading

  • Zhang, Tao;Ding, Fa-xing;Wang, Liping;Liu, Xue-mei;Jiang, Guo-shuai
    • Steel and Composite Structures
    • /
    • 제28권5호
    • /
    • pp.573-588
    • /
    • 2018
  • The objective of this paper is to investigate the mechanical performances of polygonal concrete-filled circular steel tubular (CFT) stub columns under axial loading through combined experimental and numerical study. A total of 32 specimens were designed to investigate the effect of the concrete strength and steel ratio on the compressive behavior of polygonal CFT stub columns. The ultimate bearing capacity, ductility and confinement effect were analyzed based on the experimental results and the failure modes were discussed in detail. Besides, ABAQUS was adopted to establish the three dimensional FE model. The composite action between the core concrete and steel tube was further discussed and clarified. It was found that the behavior of CFT stub column changes with the change of the cross-section, and the change is continuous. Finally, based on both experimental and numerical results, a unified formula was developed to estimate the ultimate bearing capacity of polygonal CFT stub columns according to the superposition principle with rational simplification. The predicted results showed satisfactory agreement with both experimental and FE results.

Response of passively loaded pile groups - an experimental study

  • Al-abboodi, Ihsan;Sabbagh, Tahsin Toma;Al-salih, Osamah
    • Geomechanics and Engineering
    • /
    • 제20권4호
    • /
    • pp.333-343
    • /
    • 2020
  • Preventing or reducing the damage impact of lateral soil movements on piled foundations is highly dependent on understanding the behavior of passive piles. For this reason, a detailed experimental study is carried out, aimed to examine the influence of soil density, the depth of moving layer and pile spacing on the behavior of a 2×2 free-standing pile group subjected to a uniform profile of lateral soil movement. Results from 8 model tests comprise bending moment, shear force, soil reaction and deformations measured along the pile shaft using strain gauges and others probing tools were performed. It is found that soil density and the depth of moving layer have an opposite impact regarding the ultimate response of piles. A pile group embedded in dense sand requires less soil displacement to reach the ultimate soil reaction compared to those embedded in medium and loose sands. On the other hand, the larger the moving depth, the larger amount of lateral soil movement needs to develop the pile group its ultimate deformations. Furthermore, the group factor and the effect of pile spacing were highly related to the soil-structure interaction resulted from the transferring process of forces between pile rows with the existing of the rigid pile cap.

Plate Anchor의 인발거동에 관한 모형실험 (A Model Test on Uplift Behavior of Plate Anchor)

  • 김서성;이상덕;구자갑;전몽각;유건선
    • 대한토목학회논문집
    • /
    • 제14권5호
    • /
    • pp.1219-1227
    • /
    • 1994
  • 앵커의 극한인발력을 결정하기 위해서는 인발에 의한 지반의 파괴기구를 정확하게 알아야 한다. 그러나 앵커의 인발저항에 영향을 끼치는 요소 중에서 묻힘비에 따른 파괴기구의 변화에 대한 기존의 연구가 미흡한 실정이다. 본 연구에서는 판앵커의 수직인발시 묻힘비에 따른 파괴가구의 변화를 보다 명확히 관찰하고, 지존의 극한인발력 산정식의 적용성을 판단하기 위하여 탄소봉으로 조성된 평면변행률상태의 지반에서 모형실험을 실시하였다. 그 결과로서, 얕은앵커상태와 깊은앵커상태일 때의 지반의 파괴특성을 명확히 구분할 수 있었으며, 깊은앵커의 극한인발력의 산정에 앞서 얕은앵커의 해석이 선행되어야 한다는 것이 증명되었다.

  • PDF

보수$\cdot$보강된 철근콘크리트 보의 휨 및 전단 거동에 관한 연구 (A Study on the Flexural and Shear Behavior of Repaired and Rehabilitated RC Beams)

  • 김태봉;이재범;류택은
    • 한국안전학회지
    • /
    • 제14권1호
    • /
    • pp.129-140
    • /
    • 1999
  • This study presents test results of RC beams strengthened by steel plates, carbon fiber sheets(CFS) and aramid fiber sheets(AFS) for increasing flexural and shear resistance. The test was performed with different parameters including the type of strengthening materials, flexural-strengthening methods and shear-strengthening methods. In case of flexural test, RC beams are initially loaded to 70% of the ultimate flexural capacity and in case of shear test loaded to 60 or 80 percent of the ultimate shear capacity and subsequently reinforced with steel plates, CFS and AFS. Experimental data on strength, steel strain, deflection, and mode of failure of the reinforced beams were obtained, and comparisons between the different shear reinforced schemes and the non-strengthened control beams were made. The test results showed that damaged RC beams strengthened by steel plates, CFS and AFS have more improved the flexural and shear capacity. For the beams with external reinforcement by steel plates, aramid fiber sheets and carbon fiber sheets increases in ultimate strength of 4 to 21, 17 to 43 and 26 to 36 percent were respectively achieved. Initial load had small effect on strength after reinforcement, but an important influence on deflection. One sheet reinforced was stronger than two sheets reinforced but less deflected than two sheets reinforced.

  • PDF