• Title/Summary/Keyword: UV-A

Search Result 7,059, Processing Time 0.036 seconds

Sterilization of Escherichia coli Based on Nd: YAG Resonator with a Pulsed Xenon Flashlamp

  • Kim, Hee-Je;Kim, Dong-Jo;Hong, Ji-Tae;Xu, Guo-Cheng;Lee, Dong-Gil
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.275-279
    • /
    • 2011
  • Sterilization of Escherichia coli (E. coli) is examined using a unique pulsed ultra-violet (UV) elliptical reactor based on Nd:YAG laser resonator, UV radiation from a pulsed xenon flashlamp. The light from the discharge has a broadband emission spectrum extending from the UV to the infrared region with a rich UV contained. Sterilization method by using the UV light is fast, environment-friendly and it does not cause secondary pollution. A Nd:YAG laser resonator having elliptical shape has advantage of concentrating the radiation of the UV light at two foci as the quart sleeve filled with E. coli. The primary objective of this research is to determine the important parameters such as pulse per second (pps), the applied voltage for sterilizing E. coli by using an UV elliptical reactor. From the experiment result, the sterilization effect of UV elliptical reactor is better than that of UV cylindrical reactor, and it can be 99.9% of sterilization at 800V regardless of the pps within 10 minutes.

UV-B Effects on Growth and Nitrate Dynamics in Antarctic Marine Diatoms Chaetoceros neogracile and Stellarima microtrias (중파 자외선에 노출된 남극 규조 Chaetoceros neogracile와 Stellarima microtrias의 성장과 질산염 흡수량의 변화)

  • Gang, Jae Sin;Gang, Seong Ho;Lee, Yun Ho;Sim, Jeong Hui;Lee, Sang Hun
    • ALGAE
    • /
    • v.18 no.1
    • /
    • pp.13-20
    • /
    • 2003
  • Two isolated Antarctic marine diatoms, Chaetoceros neogracile VanLandingham and Stellarima microtrias (Ehrenberg) Hasle and Sims were examined to show changes of growth and uptake rate of nitrate due to UV-B irradiance. Chlorophyll (chl) a concentration was regarded as the growth index of diatom. The diatoms were treated with UV-B radiation and cultured for 4 days under cool-white fluorescent light without UV-B radiation. Two levels of UV-B exposures were applies: 1 and 6 W $m^{-2}$. Durations of UV-B treatment were 20, 40 and 60 minutes under 6 W $m^{-2}$ and 1, 2, 3, 4 and 5 hrs under 1 W $m^{-2}$. The control groups were cultured at the same time without UV-B radiation. The growth rates of two diatoms decreased under 1 and 6 W $m^{-2}$ UV-B irradiances than that of control group. After 4 days, chl a concentrations of C. neogracile were increased more than 4 times from 133 μgo$l^{-1}$ to 632 μgo$l^{-1}$ in control group. However, the concentration of experimental groups under 1 W $m^{-2}$ UV-B were only increased from 139 μgo$l^{-1}$ to 421 μgo$l^{-1}$ during one hour and the chl a concentrations were decreased from 144 μgo$l^{-1}$ to 108 μgo$l^{-1}$ during five hour. Growth of diatom dramatically more decreased under 6 W $m^{-2}$ UV-B than 1 W $m^{-2}$ UV-B. The chl a concentration of experimental groups under 6 W $m^{-2}$ UV-B for one hour was only increased from 111 μgo$l^{-1}$ to 122 μgo$l^{-1}$. In the case of S. microtrias showed also similar pattern to C. neogracile by UV-B radiation. The uptake rates of nitrate by the two strains were decreased abruptly under 6 W $m^{-2}$ UV-B irradiances. When two strains were treated under 1 and 6 W $m^{-2}$ UV-B during one hour, the strains were only continued growth and uptake of nitrate under 1 W $m^{-2}$ UV-B. This experimental evidence shows that exposure to UV-B radiation especially to high irradiance of UV-B decreases diatom survival and causes lower decrease of nutrient concentrations by microalgae in Antarctic water. Furthermore, evidence suggests that microalgal communities confined to near-surface waters in Antarctica will be harmed by increased UV-B radiation, thereby altering the dynamics of Antarctic marine ecosystems.

Inactivation of E. coli by Electrolysis+UV Process (전기+UV 공정에 의한 E. coli 불활성화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.5
    • /
    • pp.667-673
    • /
    • 2009
  • This study has carried out to evaluate the performance of single (electrolysis, UV and ultrasonic process) and complex process (Electrolysis+UV, UV+Ultrasonic and Electrolysis+Ultrasonic) for the purpose of disinfection of Escherichia coli in water. The order of disinfection performance for E. coli in single process lie in: Electrolysis ${\fallingdotseq}$ UV >> ultrasonic process. OH radical was not produced in single disinfection process. Among the three kinds of complex process, disinfection performance of the Electrolysis+UV was higher than that of the other process (UV+Ultrasonic and Electrolysis+Ultrasonic). It demonstrated a synergetic effect between the UV and electrolysis. When the use of $Na_2SO_4$ as electrolyte instead of NaCl, current increase or more reaction time was needed for the complete disinfection. The disinfection performance of pre-electrolysis (20 W, 30sec) and post-UV (10 W, 30 sec) was higher than that of the simultaneous electrolysis+UV process at same electric power (30 W, 30 second).

Analysis of the shrinkage and warpage of Wafer lens during UV curing (Lens 성형시 UV경화 반응에 따른 수축 및 변형 대한 해석적 접근)

  • Park, Sihwan;Moon, Jong-Sin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.11
    • /
    • pp.6464-6471
    • /
    • 2014
  • The UV curing method is a popular process for lens molding on a unit wafer. This process, however, has several drawbacks including wafer adhesion during the ejection process after curing, errors in lens shape and wafer warpage due to material shrinkage during the curing process, and lens centering errors on both sides of a wafer. Among these, the lens shape error and warpage are influenced directly by the UV curing process due to factors including the UV radiation uniformity, the degree of cure according to UV intensity, and the shrinkage characteristics of the material. Therefore, a theory is needed not only to understand the change in the material characteristics, such as the shrinkage rate due to the curing reaction, but also to establish a model. In addition, an analysis system is needed to realize the model. This study proposes a new analysis method for the wafer lens molding process by Comsol modeling. This method was verified by comparing the results with those of the actual process.

UV Dose Predictions for Ultra Violet Flowing Water Purification of Axial Reactor Type based on the location of the exit by CFD (CFD에 의한 Axial Reactor Type 자외선 유수살균장치의 출구 위치에 따른 UV Dose 예측)

  • Choi, Jong-Woong;Kim, Seong-Su;Park, No-Suk;Lee, Young-Joo;Chae, Seon-Ha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.4
    • /
    • pp.521-533
    • /
    • 2012
  • Interest in application of ultraviolet light technology for primary disinfection that used for the treatment of water for consumption and wastewater has increased significantly in recent years. Analysis of these systems has been carried out using Computational Fluid Dynamics (CFD) procedure. It offers advantages over other techniques in specific circumstances. CFD has emerged as a powerful tool to aid design of a UV reactor by providing the UV dose delivered by the proposed reactor design and allowing engineers to evaluate alternative designs in much less time and at a reasonable cost. In this study, five different configurations of the apparatus depending on the location of the exit are evaluated in terms of maximum dose, minimum dose, flow patterns, particle tracks and transient dose. The configuration 3 results have higher minimum UV dose value and uniform particle distribution of the UV dose on the outlet than other's.

Manufacturing and Characteristics of the Electrodeless UV Lamp for Disinfection of the Sewage Effluent (하수 방류수 살균소독을 위한 무전극 UV 램프의 제조 및 특성)

  • Shin, Dong Ho;Lee, Yong Taek
    • Applied Chemistry for Engineering
    • /
    • v.16 no.4
    • /
    • pp.570-575
    • /
    • 2005
  • In this study, we have manufactured electrodeless ultraviolet lamp which has a long life and a high degree of efficiency than the existing electrode UV lamp used in sewage effluent sterilization disinfection. First, we investigated change of UV intensity and temperature of lamp by activation materials. The best results for the dose response experiments were 250 minutes stabilizing to UV intensity of $300{\mu}W/cm^2$ and surface temperature $200{\sim}250^{\circ}C$ in Hg/Ind's weight ratio 95/5. When electrodeless UV lamp emits light for prolonged hours, surface temperature of lamp increases. therefore, temperature change is studied using a duplex lamp for cooling in actual sewerage process. Also, manufactured electrodeless UV lamp showed sterilization efficiency of more than 99.9% as result that experiment manufactured electrodeless UV lamp by E-coli. for sterilization disinfection of sewage effluent.

Dietary effect of green tea extract on epidermal levels of skin pH related factors, lactate dehydrogenase protein expression and activity in UV-irradiated hairless mice (자외선 조사와 병행된 녹차 식이 공급이 무모생쥐의 표피 산도 관련 인자 함량 및 젖산 탈수소 효소의 단백질 발현과 활성에 미치는 영향)

  • Lee, Bomin;Kim, Jongyei;Hwang, Jaesung;Cho, Yunhi
    • Journal of Nutrition and Health
    • /
    • v.49 no.2
    • /
    • pp.63-71
    • /
    • 2016
  • Purpose: Skin pH, an indicator of skin health, is maintained by various organic factors, which include lactate, free amino acid (FAA), and free fatty acid (FFA). As skin ages or with illness, skin pH becomes less acidic, and functional food has been developed to maintain the acidic pH of skin. In this study, we determined the dietary effect of green tea extract (GTE) on skin pH of photo-aged mice, as measured by epidermal levels of lactate, FAA, and FFA. The protein expression and activity of lactate dehydrogenase (LDH), an enzyme of pyruvate reduction for lactate generation, was further determined. Methods: Albino hairless mice were fed a control diet (group UV+) or a diet with 1% GTE (group GTE) in parallel with UV irradiation for 10 weeks. A normal control group was fed a control diet without UV irradiation for 10 weeks (group UV-). Results: Skin pH was higher (less acidic) in group UV+ than in group UV-. In parallel, epidermal levels of lactate and FFA, as well as of LDH protein expression and activity, were reduced in group UV+. Dietary supplementation of GTE (group GTE) reduced skin pH to similar to the level of group UV-, and inversely increased epidermal levels of lactate, LDH protein expression and activity, but not of FFA. Although epidermal levels of FAA were similar in groups UV- and UV+, it was increased in group GTE to a level higher than in group UV-. In further analysis of major FFA, epidermal levels of palmitic acid [16:0], oleic acid [18:1(n-9)], and linoleic acid [18:2(n-6), but not of stearic acid [18:0] in group GTE were similar to or lower than those in group UV+. Conclusion: Dietary GTE normalized skin pH with increased levels of lactate and FAA, as well as with increased protein expression and activity of LDH in the epidermis of UVB irradiated hairless mice.

Optical Ozone Monitor Using UV Source

  • Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.49-52
    • /
    • 2003
  • Two types of ozone monitors using UV absorption method were tried in consideration of cost of the monitor and precision in measuring. The high concentration ozone monitor for high concentration real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source, a photo multiplier tube as UV detector and signal processing unit for the most part. This structure could be very useful for low price high concentration ozone monitor due to simple system structure and fairly good monitoring characteristics. The developed system showed good linear output characteristics to ozone in the measuring concentration range of 0.05 and 2 wt.%. For accuracy ambient ozone monitoring in ambient in ppm level, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit in brief speaking was proposed our study for the first time in the world. The developed system showed good linearity and sensitivity in relative low measuring range between 10ppm and 10,000ppm, and showed some feasibility of high resolution ozone monitor using CCD array as photodetector.

  • PDF

Simultaneous determination of betaine and choline using derivatization by HPLC with UV detection (HPLC-UV검출방법으로 유도체화를 통한 비테인과 콜린의 동시분석)

  • Rhee, Insook;Paeng, Ki-Jung
    • Analytical Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.112-116
    • /
    • 2015
  • Extraction of quaternary ammonium compounds (choline and betaine) from plant samples (spinach) using ion exchange resin (AG1, OH form) is a very simple and inexpensive approach. However, it is very hard to determine amounts of choline and betaine simultaneously using high-performance liquid chromatography-ultraviolet (HPLC-UV) detection. Unlike choline, betaine has low molar absorptivity in UV-visible (UV-Vis) region, which makes it difficult to carry out UV-Vis detection of betaine. The mixture of quaternary ammonium compounds (choline and betaine) was derivatized using 2-bromo acetophenone as a derivatizing agent. As a result, choline did not react with the derivatizing agent, whereas betaine formed a betaine derivative. This betaine derivative exhibited detectable UV absorption with baseline separation between choline and the betaine derivative. Thus, with this method, choline and betaine can be determined simultaneously by using the HPLCUV method through one-step derivatization, which is an easy, sensitive, and reliable method.

Analysis of Disinfection Performance of UV LEDs for a Phytoplankton (식물성 플랑크톤에 대한 UV LED의 살균성능 분석)

  • Kil, Gyung-Suk;Choi, Sung-Kuk;Park, Dae-Won;Kim, Sung-Wook;Cheon, Sang-Gyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.959-964
    • /
    • 2009
  • This paper dealt with the disinfection performance by Ultra-Violet Light Emitting Diode (UV LED) for a phytoplankton as a basic study for the development of a low-energy consumption ballast water treatment system. UV LEDs having peak wavelength of 255nm, 265nm and 280nm were used in the experiment. UV LED modules with driving circuit were fabricated, and optical and electrical characteristics of them were analyzed. The disinfection performance for phytoplankton depending on the UV wavelength was evaluated by comparing the number of phytoplankton before and after the UV treatments. The experimental result showed that the highest disinfection wavelength for the phytoplankton was 265nm.