• Title/Summary/Keyword: UV sterilizer

Search Result 22, Processing Time 0.021 seconds

Development of a new efficient UV/Ozone duplex sterilizer (새로운 고효율 UV/Ozone 복합 살균기의 개발)

  • Park, Eun-Cheol;Kim, Gang-Seok;Ji, Jeong-Eun;Yang, Won-Gyun;Ju, Jeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.48-49
    • /
    • 2007
  • 자외선 살균기는 기존의 살균기보다 효율적으로 작동되어, 모델의 세균살균을 향상시키기 위하여 투과 반사와 오존을 복합적으로 사용하였다. 투과 반사 효과가 기존의 모델에 비해 세균살균의 효율에 상당한 영향을 주었음을 알 수 있었다.

  • PDF

UV Immune System of Personalized Space (개별공간의 자외선 살균 시스템)

  • Jeong, Ky-Bum;Choi, Sang-Gon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.1
    • /
    • pp.63-70
    • /
    • 2009
  • The air sterilization systems are investigated experimentally in this paper. The goal is to reduce bacteria, mold and viruses in office air by using a UV sterilizer installed inside a partition panel and wall-mounted unit. These systems allow occupants to turn the system on/off and to control the incoming air speed and direction. The partition air sterilization system conditions and sterilizes the air, and then delivers the clean air into the personal task area through the partition panels, which are connected to the pressurized under-floor plenum. Room air exits through the return grills mounted on the ceiling. The wall-mounted air sterilization system sterilizes the air, and then delivers the clean air to the personal task area from the wall. In this study a full-size experimental environment is established to investigate the immunization performance of these air sterilization systems. A typical office space scale is used in this study in order to find an optimal system to achieve a sterilized healthy micro-environment. Multiple system parameters, including volume flow rate and velocity of supplied air, were regulated during the experiments. The more air contact these air sterilization systems had, the better disinfection performance. Over 90% of eradication ratios were obtained by these two air sterilization systems. The results indicate that these systems can efficiently disinfect office air contamination.

A study on the state of infection control in dental clinic (치과진료실에서의 감염관리 실태 조사)

  • Kim, Kyung-Mi;Jung, Jae-Yeon;Hwang, Yoon-Sook
    • Journal of Korean society of Dental Hygiene
    • /
    • v.7 no.3
    • /
    • pp.213-230
    • /
    • 2007
  • The purpose of this study was to examine the state of infection control provided to members of Korean Dental Hygienists Association. The subjects in this study were dental hygienists who attended a symposium on July 1. 2006. after a survey was conducted, the answer sheets from 489 participants were analyzed, and the findings of the study were as follows: 1. Possession of disinfection room was being(72.7%), and person of infection control was zero(52.9%). Number of sterilizer was one(62.2%). 2. As a repetition choice, type of sterilizer was autoclave(97.9%), UV sterilizer(67.4%) and EO gas sterilizer(21.4%). As a repetition choice, infection materials was ethanol(84.1%). 3. Water tube of unit and chair was using of sterilized water(42.9%). Sterilizing of compressed air was no(69.0%). 4. Re-using of disposal was not using(62.5%), re-using disposal was suction tip(28.2%)(repetition choice) 5. In sterilization of instruments, hand-piece was every using time(28.4%), and reamer-file, bur, mirror, pincette, explorer, hand scaler and ultrasonic scaler were high in every using time. 6. Individual protection was high of using, cleaning of hands before treatment was every treatment(87.0%). Type of soap was liquid type in dental clinic(48.2%), infection soap in dental hospital(41.2%) and solid soap in public health center(50.6%). Answered that they need regular oral health education, and 82.9% respondents answered that they need oral health technicians in school. And 87.8% respondents needed individual oral health education for the benefit of better oral health.

  • PDF

A study on the design development of a domestic disinfector using UV LED (UV LED를 이용한 가정용 소독기의 디자인 개발에 관한 연구)

  • Zhu, Wang;Sheng, Ying;Kang, Seung-Min;Jee, Moon-Hwan
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.29 no.6
    • /
    • pp.264-269
    • /
    • 2019
  • The design for household sterilizer applying UV LED was studied. Based on UV LED sterilization distance and time data, the concept of home disinfectioner design was presented. Using technologies such as computer aided design software, 3D printing and laser cutting, etc., three different UV LED operating method models were produced. The final design was derived by conducting an analysis of the product's merits and demerits on the three plans from the result of each model.

The developement of multi-layer sterilizer using Ultra Violet irradiation (자외선 조사를 이용한 다단계 컨베이어 자동 살균기 개발에 관한 연구)

  • Kim, Y.C.;Yoo, G.H.;Jung, Y.G.;Kim, H.S.;Jung, T.S.;Yun, B.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3060-3063
    • /
    • 1999
  • We made a multi-layer conveyor sterilizing system using UV rays to prolong a storage period of dried marine products. The system is composed of 5 layer conveyor belt of 3 m long each, thus 15 m long in total. It is designed to radiate UV rays for 10 minutes the dried marine products, and can process 300 kg/hour. Eight UV lamps of 30 cm long and 15 W of power with 254 nm wave length are installed in parallel, 15 cm high above in each belt, and 40 lamps in total. The whole system is covered by 1 mm thick metal plates to block the UV rays except a front side which is covered with 5 mm thick plastic plates coated with UV protection film to survey inside of the system. A sterile ratio is about 99.97% with 10 minutes sterilization using this system.

  • PDF

Sterilization Effect of Microbial Strains by using Non-ionizing Radiation (비전리방사선을 이용한 미생물 균주 멸균효과)

  • Jeong, Kyeonghwan;Seo, Jeongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.833-839
    • /
    • 2020
  • Globally, infection prevention and social awareness have been greatly changed by the severe acute respiratory syndrome coronavirus, and as a result, the infection control guidelines and procedures for patients with high exposure to hospital-acquired infection are further strengthened and management and monitoring are more thorough. In order to prevent infection, sterilization should be carried out with the highest priority, and we will find a sterilization method that is low in cost, easy to install, and easy to operate, to present appropriate sterilization effects. In this study, the UV sterilizer was used to contaminate the caries bacteria with an output of 4 W and irradiation time of 60, 150, and 300 sec, and the laser was irradiated with outputs of 0.8 and 1.5 W at wavelengths of 266 and 355 nm, respectively. Ultraviolet sterilizer showed safety in infection prevention at over 150 sec, and laser showed safety in prevention at 1.5 W, 0.8 W, and 266 nm. As a result, the higher the output and the wavelength closer to 253.7 nm, the better the sterilization effect.

Wettability and cellular response of UV light irradiated anodized titanium surface

  • Park, Kyou-Hwa;Koak, Jai-Young;Kim, Seong-Kyun;Heo, Seong-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.2
    • /
    • pp.63-68
    • /
    • 2011
  • PURPOSE. The object of this study was to investigate the effect of UV irradiation (by a general commercial UV sterilizer) on anodized titanium surface. Surface characteristics and cellular responses were compared between anodized titanium discs and UV irradiated anodized titanium discs. MATERIALS AND METHODS. Titanium discs were anodized and divided into the following groups: Group 1, anodized (control), and Goup 2, anodized and UV irradiated for 24 hours. The surface characteristics including contact angle, roughness, phase of oxide layer, and chemical elemental composition were inspected. The osteoblast-like human osteogenic sarcoma (HOS) cells were cultured on control and test group discs. Initial cellular attachment, MTS-based cell proliferation assay, and ALP synthesis level were compared between the two groups for the evaluation of cellular response. RESULTS. After UV irradiation, the contact angle decreased significantly (P<.001). The surface roughness and phase of oxide layer did not show definite changes, but carbon showed a considerable decrease after UV irradiation. Initial cell attachment was increased in test group (P=.004). Cells cultured on test group samples proliferated more actively (P=.009 at day 2, 5, and 7) and the ALP synthesis also increased in cells cultured on the test group (P=.016 at day 3, P=.009 at day 7 and 14). CONCLUSION. UV irradiation induced enhanced wettability, and increased initial cellular responses of HOS cells on anodized titanium surface.

Ultraviolet Lamp Replacement Period and Hygiene Management Plan of Ultraviolet Sterilizer (자외선 살균고의 자외선 램프 교체 주기와 위생관리 방안)

  • Young-Ju Lee;Ju-Hyun Lee;Eun-Sol Go;Jung-Beom Kim
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.1
    • /
    • pp.26-30
    • /
    • 2023
  • In this study, we analyzed the microbial contamination level of ultraviolet sterilizer (UVS) chambers and suggested plans to improve hygiene management. In this study, UVS chambers targeted 98 UVS in some childcare centers in Jeollanam-do, Korea. Total aerobic bacteria and coliform bacteria were tested according to the Korean Food Code. Of the 98 UVS chambers, total aerobic bacteria were detected in 67 (68.4%) and coliform bacteria in 5 (5.1%). Six kinds of food-poisoning bacteria, including Salmonella spp., were not detected, but Bacillus cereus was detected in 1 (2.8%) out of 98 UVS chambers. According to the UV lamp replacement period, the detection rate of total aerobic bacteria was 3 (50%) out of 6 UVS within 3 months, 3 (60%) out of 5 UVS in 3 to 6 months, and 61 (70.1%) out of 87 UVS over 6 months. The detection rate of coliform bacteria according to the UV lamp replacement period was not detected within 6 months, however, they were detected in 5 (5.7%) out of 87 chambers after more than 6 months. The level of microbial contamination in the UVS chambers was higher as the lamp replacement period was longer. Considering these results, it was determined that the UVS chambers should be kept dry and clean, and the UV lamp should be replaced periodically. In addition, it is necessary to provide the staff catering for childcare centers with continuous education regarding the cleaning of UVS chambers and the replacement of UV lamps.

Water Quality Assessment of Major Drinking Waters in Natural Parks (자연공원내 주요 음용수의 수질환경평가)

  • Yi, Youngkyoung;Yi, Pyongin;Hong, Sungchul
    • Journal of the Korean Society of Urban Environment
    • /
    • v.18 no.4
    • /
    • pp.439-453
    • /
    • 2018
  • The purpose of this study is to evaluate water quality characteristics of main drinking waters in natural parks, for providing the basic information of water quality and to propose the appropriate management method. to maintain the water quality standards. As a result of the analysis, microorganisms were mostly detected in the nature of natural park. And some sites are currently using UV sterilizer and ozone treatment, and it is considered appropriate to extend the use to other main drinking water. It is also good to boil drinking water at home. Turbidity is expected to improve through environmental cleanup. Overall, the main drinking water in the natural park is suitable for water quality standards, and it is considered that maintenance such as cleaning is necessary.