Self-driving quarantine robot with chlorine dioxide system (이산화염소 시스템을 적용한 자율주행 방역 로봇)

  • Bang, Gul-Won
    • Journal of Digital Convergence
    • /
    • v.19 no.12
    • /
    • pp.145-150
    • /
    • 2021
  • In order to continuously perform quarantine in public places, it is not easy to secure manpower, but using self-driving-based robots can solve problems caused by manpower. Self-driving-based quarantine robots can continuously prevent the spread of harmful viruses and diseases in public institutions and hospitals without additional manpower. The location of the autonomous driving function was estimated by applying the Pinnacle filter algorithm, and the UV sterilization system and chlorine dioxide injection system were applied for quarantine. The driving time is more than 3 hours and the position error is 0.5m.Soon, the stop-avoidance function was operated at 95% and the obstacle detection distance was 1.5 m, and the automatic charge recovery was charged by moving to the charging cradle at the remaining 10% of the battery capacity. As a result of quarantine with an unmanned quarantine system, UV sterilization is 99% and chlorine dioxide is sterilized more than 95%, which can contribute to reducing enormous social costs.

Design of a shoe rack for effective sterilization and deodorization of the shoes contaminated by various bacteria (오염된 신발의 효율적인 살균과 탈취를 위한 신발장의 설계)

  • Lee, Sam-Cheol;Jang, Yong-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.199-206
    • /
    • 2016
  • The aim of this study was to establish the optimal conditions to design a shoe rack that could effectively sterilize and deodorize shoes contaminated by various bacteria. The manufacture and evaluation of a shoe rock was conducted for one year from October 2014 to September 2015. The antibacterial efficacies were evaluated using Escherichia coli and Staphylococcus aureus by JIS Z 2801:2010. The deodorization efficiency was identified by the standard method for deodorization efficiency evaluation of an indoor air cleaner established by Korea Air Cleaning Association, SPS-KACA002-132:2006. The results showed that antibacterial evaluation showed more than 99.9% of the sterilization effects on Escherichia coli and Staphylococcus aureus after exposure to ultraviolet (UV) light for 30 seconds. The average deodorization efficiency for the test gases was 42.5%. The temperature in the shoes and in the shoe rack was lower than $40^{\circ}C$ and $25^{\circ}C$, respectively, when the UV lamp was turned on for 5 minutes and off for 25 minutes repeatedly. This was controlled by turning the UV lamp on and off to maintain the appropriate temperature in the shoes. In conclusion, the real deodorization efficiency is expected to be higher than the measured value because the internal volume of the shoe rack was smaller than the test chamber used to measure the deodorization efficiency. The deodorization effect could be increased further by the sterilization of bacteria causing bad odors in shoes. Further studies will be needed to determine the temperature deviations within the shoe rack to provide constant conditions.

Effects of UV Sterilization on Quality of Acer mono Sap (자외선 살균이 고로쇠 수액의 품질에 미치는 영향)

  • Choe, Su Bin;Han, Sang Jin;Han, Ouk Hee;Kim, Hak Su;Kang, Sung Tae
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.1
    • /
    • pp.148-152
    • /
    • 2013
  • An ultraviolet (UV) sterilization system was developed to decrease the number of microorganisms in filtered Acer mono sap (FAS). The Acer mono sap (AS) was passed through 18 strips of PTA fluoroplastic tubing with 30 UV lamps (total 1,170 W). During passage, the AS was effectively exposed to the UV rays. The total bacteria, coliform group and fungi were sterilized at a flow rate ranging from 852 to 1,358 mL/min and a UV power higher than 156 W. Although the sensory score of the UV-sterilized AS was significantly lower than that of the untreated AS, the sensory score was better under the condition of 390 W and 852~1,358 mL/min than under the other conditions examined. ANOVA did not reveal a significant difference in pH, total acidity, sugar content and color characteristic under all conditions tested (p<0.05). Considering the overall attributes of the AS quality, the optimum sterilization condition was determined to be 390 W and 852~1,358 mL/min.

Sterilization effect of atmospheric pressure non-thermal air plasma on dental instruments

  • Sung, Su-Jin;Huh, Jung-Bo;Yun, Mi-Jung;Chang, Brian Myung W.;Jeong, Chang-Mo;Jeon, Young-Chan
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.1
    • /
    • pp.2-8
    • /
    • 2013
  • PURPOSE. Autoclaves and UV sterilizers have been commonly used to prevent cross-infections between dental patients and dental instruments or materials contaminated by saliva and blood. To develop a dental sterilizer which can sterilize most materials, such as metals, rubbers, and plastics, the sterilization effect of an atmospheric pressure non-thermal air plasma device was evaluated. MATERIALS AND METHODS. After inoculating E. coli and B. subtilis the diamond burs and polyvinyl siloxane materials were sterilized by exposing them to the plasma for different lengths of time (30, 60, 90, 120, 180 and, 240 seconds). The diamond burs and polyvinyl siloxane materials were immersed in PBS solutions, cultured on agar plates and quantified by counting the colony forming units. The data were analyzed using one-way ANOVA and significance was assessed by the LSD post hoc test (${\alpha}$=0.05). RESULTS. The device was effective in killing E. coli contained in the plasma device compared with the UV sterilizer. The atmospheric pressure non-thermal air plasma device contributed greatly to the sterilization of diamond burs and polyvinyl siloxane materials inoculated with E. coli and B. subtilis. Diamond burs and polyvinyl siloxane materials inoculated with E. coli was effective after 60 and 90 seconds. The diamond burs and polyvinyl siloxane materials inoculated with B. subtilis was effective after 120 and 180 seconds. CONCLUSION. The atmospheric pressure non-thermal air plasma device was effective in killing both E. coli and B. subtilis, and was more effective in killing E. coli than the UV sterilizer.

Bactericidal Effect of Ultraviolet and Dry Treatment on Bacterial Contaminants in Facial Masks (Ultraviolet 및 건조 처리에 의한 마스크에 오염된 미생물 살균 효과)

  • Park, Seul-Ki;Lee, Da-eun;Jo, Du-Min;Song, Mi-Ru;Kim, Young-Mog
    • Microbiology and Biotechnology Letters
    • /
    • v.50 no.1
    • /
    • pp.95-101
    • /
    • 2022
  • Due to the pandemic caused by COVID-19, the demand for face masks is soaring and has often caused a shortage. The aim of this study was to evaluate the effect of ultraviolet (UV) and drying treatments on microbial contaminants in facial masks. To conduct this study, standard procedures were designed to develop samples contaminated by the control bacteria Escherichia coli, Staphylococcus aureus, and Pseudomonas aeruginosa. The contamination level of the standard samples was approximately 6.30 × 106 CFU/ml, and the UV light treatment was performed 1, 3, 5, and 7 times. To evaluate the effect of the UV and drying treatments, the masks were first treated with UV 1, 2, and 3 times, followed by the drying process. As a result, the mask contaminated with E. coli and P. aeruginosa showed a bacterial rate of approximately 99.9% after 1 UV irradiation, and in the case of the S. aureus-contaminated mask, it exhibited a bactericidal rate of approximately 99.9% after 7 UV irradiations. However, when the drying process was included after UV irradiation, all the samples contaminated with E. coli, S. aureus, and P. aeruginosa showed a bactericidal rate of 99.9% or more. The results of this study suggest that UV and drying treatments can effectively reduce the bacterial contaminants in facial masks. In addition, these results provide fundamental data and appropriate sterilization methods for reusing masks.

The effects of UV excited $TiO_{2}$ and ZnO coating on activated carbon for Escherichia coli (활성탄에 침착시킨 $TiO_2$와 ZnO가 자외선에 의하여 활성화되었을때 Escherichia coli의 살균효과에 미치는 영향에 관한 연구)

  • 최명신;정문호;김영규
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.3
    • /
    • pp.105-114
    • /
    • 1995
  • There has been increasing awareness on the importance of not only removal of organic materials but also sterilization of microbial cell in the drinking water purification research, so there has been many researches on that area. This study has been designed to analyze the effects of $TiO_{2}$ and ZnO coated on activated carbon on Escherichia coli. In this study, the sterilization power was analyzed by (1) variation of $TiO_{2}$ and ZnO concentration coated on activated carbon (2) variation of UV intensity. In addition, the kinetics between exposure time and sterilization velocity was viewed by the method of Chick. The results are as follows. 1. Survival ratio of E. coli decreased as time goes on in application of $TiO_{2}$, ZnO and $TiO_{2}{\cdot}ZnO$. In $TiO_{2}$ and ZnO, the effect increased upto certain concentration, but decreased there-after. In $TiO_{2}{\cdot}ZnO$, the effect of sterilization was in similar way among 3 combinations. 2. Survival ratio of E. coli decreased proportionately to an increase of light intensity in ZnO and $TiO_{2}{\cdit}ZnO$. In $TiO_{2}$, the survival ratio differed over extent of irradiation but the difference over the light intensity was not significant. 3. When Chick's law of sterilization was applied, m values of three concentrations of $TiO_{2}$ were 1.57,0.98, 1.96 respectively. M values of three concentration of ZnO were 1.10, 1.18,0. 11 respectively and those of three combination of $TiO_{2}{\cdot}ZnO$ were 1.17, 1.24, 1.74 respectively.

  • PDF

A Study on Sterilization Characteristics of Elliptical Reactor by Using Xenon Flashlamp and Photocatalyst (Xenon flashlamp와 광촉매를 이용한 타원형 반응기의 살균 특성에 관한 연구)

  • Lee, Dong-Gil;Hong, Ji-Tae;Choi, Kyoung-Hwa;Cha, Jae-Ho;Kim, Hong-Ju;Kim, Hee-Je
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.559-565
    • /
    • 2009
  • In this paper, we invented a new and unique technique for the sterilization of Escherichia coli(E. coli) in polluted water. We applied a rich ultra-violet(UV) light from pulsed xenon flashlamp and photocatalyst(TiO2) to sterilize E. coli in polluted water. This method based on the use of UV light and photocatalyst is eco-friendly and does not cause secondary pollution. The proposed elliptical reactor is able to concentrate on quartz sleeve coated TiO2 or general quartz sleeve. The primary objective of our research was to determine the important parameters such as pulse repetition rate and input voltage and to know on the sterilizing efficiency of quartz sleeve coated TiO2 and general quartz sleeve. We obtained to achieve 99.999% sterilization in as little as 6 pulses at 800V in case of quartz sleeve coated Ti02, and 10 pulses at 800V in case of general quartz sleeve for 5 minutes. Although transmitted light of quartz sleeve coated TiO2 is deceased, the sterilizing efficiency is increased by 40% than general quartz sleeve. The reason of high sterilizing efficiency is that generated hydroxyl radical(OH) by photocatalyst and is able to concentrate light at a focus by using elliptical reactor.

Microbiological Evaluation for HACCP System Application of Green Vegetable Juice Containing Lactic Acid Bacteria (유산균을 함유한 녹즙의 HACCP 시스템 적용을 위한 미생물학적 위해도 평가)

  • Kwon, Sang-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.4924-4931
    • /
    • 2011
  • This research performed to evaluate a production processes reporting by the HACCP system of green vegetable juice products, containing lactic acid bacteria, stage of processing raw materials agricultural products and production facilities of general bacteria and pathogenic micro organism. General bacteria are found from four samples of storage of agricultural products at process stage and water was detected 8.67~14.67 CFU/ml. However, all samples were detected less than 105 CFU/ml as a legal standards after the process of UV sterilization. For the outcome of experiment of E.coli, E.coli O157:H7, B.cereus, L.moonocytogenes, Salmonella spp, Staph.aureus as the food poisoning bacterial, E.coli was detected until UV pre-step process in storage process and B.cereus was detected partly till 1st washing. Since all bacterial, Yeast and Mold are detected in main materials, pre-control method is a necessary to establish for decreasing with a number of initial bacteria of main materials and it is considered to establish the effective ways of washing and sterilization such as production facilities for cross contamination prevention of bacteria and Sthaphylococcus. Based on above results, the process of UV sterilization should be managed with CCP as an important process to reduce or eliminate the general and food poisoning bacterial of green vegetable juice products, including lactic acid bacteria. Therefore, it is considered to need an exhaustive HACCP plan such as control manual of UV sterilization, solution method, verification, education and training and record management.

WTP UV Disinfection System (국내하수처리장 자외선소독조 운영실태 및 기술동향)

  • Lee, J.Y.;Kim, Y.T.;Lee, T.J.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.126-132
    • /
    • 2005
  • UV disinfection system allows the disinfection of municipal and industrial water and wastewater without the use of expensive chlorination and dechlorination techniques, labor intensive equipments In traditional ultraviolet systems the UV lamps are seperated from water by quartz sleeves. quartz is one of. the few materials that is virtually transparent to UV light, the UV lamp is placed inside the Quartz sleeve. UV light from the lamp is passed through the quartz and into the water, thereby providing disinfection. In fluoropolymer tube-used non-contact UV systems, the water flows through fluoropolymer plastic tubes. banks of UV lamps surround these tubes such that each tube gets exposed to ultra violet light from all sides. in non-contact design the lamps operates at almost constant temperature. this design is extremly efficient in the utilization of UV energy and superior to conventional contact- systems.

  • PDF

Sterilization of Bacteria, Yeast, and Bacterial Endospores by Atmospheric-Pressure Cold Plasma using Helium and Oxygen

  • Lee Kye-Nam;Paek Kwang-Hyun;Ju Won-Tae;Lee Yeon-Hee
    • Journal of Microbiology
    • /
    • v.44 no.3
    • /
    • pp.269-275
    • /
    • 2006
  • Atmospheric-pressure cold plasma (APCP) using helium/oxygen was developed and tested as a suitable sterilization method in a clinical environment. The sterilizing effect of this method is not due to UV light, which is known to be the major sterilization factor of APCP, but instead results from the action of reactive oxygen radicals. Escherichia coli, Staphylococcus aureus, and Saccharomyces cerevisiae deposited on a nitrocellulose filter membrane or Bacillus subtilis spores deposited on polypropylene plates were exposed to helium/oxygen plasma generated with AC input power at 10 kHz, 6 kV. After Plasma treatment, nitrocellulose filter membranes were overlaid on fresh solid media and CFUs were counted after incubation overnight. D-values were 18 sec for E. coli, 19 sec for S. aureus, 1 min 55 sec for S. cerevisiae, and 14 min for B. subtilis spores. D-values of bacteria and yeast were dependent on the initial inoculation concentration, while the D-value of B. subtilis spores showed no correlation. When treated cells were observed with a scanning electron microscope, E. coli was more heavily damaged than S. aureus, S. cevevisiae exhibited peeling, and B. subtilis spores exhibited shrunken morphology. Results showed that APCP using helium/oxygen has many advantages as a sterilization method, especially in a clinical environment with conditions such as stable temperature, unlimited sample size, and no harmful gas production.