• 제목/요약/키워드: UV photometric method

검색결과 9건 처리시간 0.02초

간접 분광 검출법에 의한 음이온의 분석(I) (Analysis of Anions by Indirect Photometric Detection (I))

  • 박만기;김박광;박정일;김경호;이미영;정재은
    • 약학회지
    • /
    • 제34권3호
    • /
    • pp.215-218
    • /
    • 1990
  • An ion chromatographic method based on indirect photometric detection of UV transparent anions was developed. Separation of anion was accomplished on strong anion exchange column (Waters SAX) using UV detector at 254 nm. Among examined UV-active additives (Dns-H, Dns-glu, Dnsser, Dns-val), Dns-glu showed the highest sensitivity. Studies on the effects of the pH and ionic strength of eluent revealed that the increase of pH and ionic strength of the eluent decreased capacity factor. The best eluent for the separation of acetate, fluoride, chloride, nitrate and bromide was $1\;{\times}\;10^{-4}M$ Dns-glu in 5 mM phosphate buffer (pH 6.30). The detection limit of chloride ion was 2.1 ng in this condition.

  • PDF

하천 발생 거품의 성분에 관한 분석 연구 (A Study on the Analysis of Components in Foam Produced from a Stream)

  • 배장순;박찬교;성기천;이석우;황용현
    • 한국응용과학기술학회지
    • /
    • 제21권2호
    • /
    • pp.117-123
    • /
    • 2004
  • According to increase of using quantity, people interested in the environmental influence by synthetic detergent. The main visible form when synthetic detergent dissolved in water is generating foams. This foam makes coating over water surface and prevents oxygen penetrating in water and make water more polluted with that result. To analyze, components and origins of the foam, and to make clear its environmental influence in this study. The analyzing objects are introducing water of sewage treatment plant from the a tributary to the Han River. After analysis, reached the conclusion like below, Analyzing foams and introducing water by sublation method, average return rate of standard LAS (1.0ppm) is 90%. LAS contents of foams analyzed by UV photometric method and HPLC method are 35.0ppm and 44.5ppm each, and AOS contents of foams analyzed by the same method are 0.6ppm and 0.4ppm each. We can find out by this study's analyzing results that the main components of foams are anion surfactant, it's content and in case of capric acid linoleic acid, it's contents.

THE BVR CCD PHOTOMETRY OF GLOBULAR CLUSTER M13

  • PYO TAE SOO;LEE SEE-WOO
    • 천문학회지
    • /
    • 제27권2호
    • /
    • pp.119-132
    • /
    • 1994
  • The BVR CCD photometry was performed for the globular cluster M13 down to $V=19^m$ over the region from the center to the west 13 arcmin and the CMD of M13 is investigated. The major photometric error in the crowded field which is due to the variation in the sky background was corrected by the median filtering method and the direct sky method. Some characteristics of the CMD of M13 obtained in the present study are as follows: Firstly, the distribution of stars on the CMD is well consistent with the mean lines of Sandage(1970) along the red giant branch(RGB), horizontal branch(HB) and asymtotic giant branch(AGB). Secondly, some gaps exists along the RGB and blue horizontal branch(BHB). Thirdly, the UV-bright stars are more concentrated at the inner region of the cluster.

  • PDF

다중 회귀분석법을 이용한 스캐너-모니터간 색보정에 관한 연구 (A study on the color management between scanner and monitor using multiple regression method)

  • 박진희;김홍석;박승옥
    • 한국광학회지
    • /
    • 제14권4호
    • /
    • pp.473-479
    • /
    • 2003
  • 본 연구는 스캔된 이미지의 원본색이 모니터에 그대로 디스플레이 될 수 있게 하는 것을 목적으로 한다. 색보정 과정은 스캐너의 색 특성 묘사를 통한 원본색의 XYZ 추정, 기준 광원의 차이를 고려한 XYZ 변환, XYZ와 RGB간의 색공간 변환으로 구성된다. 특히, XYZ 추정에 있어서 스캐너에 입사되는 빛의 세기와 출력신호간의 비선형적 관계를 두 구간으로 나누어 묘사함으로써 그 정확도를 높였다 EPSON Expression 1680 스캐너를 대상으로 실시한 결과, 228가지 기준색의 기준값과 추정값의 평균 색차는 1.47 $\Delta$ $E_{UV}$ * 이었으며, 36가지의 유채색과 22가지의 무채색으로 구성된 시험색의 평균 색차가 각각 1.51 $\Delta$ $E_{UV}$ * 와 0.90 $\Delta$ $E_{UV}$ * 이었다. 또한 시험색 36가지에 대해 기준값과 추정값으로 부터 산출된 sRGB 모니터 입력신호를 동일 모니터에 디스플레이한 결과, 두 이미지의 색이 동일하게 보였다. sRGB 모니터 입력신호를 동일 모니터에 디스플레이한 결과, 두 이미지의 색이 동일하게 보였다.

Simultaneous Determination of Alkaline Earth Metal Ions by a Conventional High Performance Liquid Chromatographic System

  • Rho, Young-Soo;Choi, Seung-Gi
    • Archives of Pharmacal Research
    • /
    • 제9권4호
    • /
    • pp.211-214
    • /
    • 1986
  • A simultaneous determination method of alkaline earth metals was attempted with the conventional high performance liquid chromatographic system. Four cations, namely, magnesium, calcium, strontium and barium ion, were injected directly as aqueous solution into an eluent containing copper chloride solution and and were successfully separated and determined on a separating column (Zipax SCX, 4.6 mm i.d. ${\times}25$ cm length, Du Pont, USA) by using a variable wavelength UV detector. The linear calibration curves were obtianed in the range from $1.0{\times}10^{-4}M$ to $5.0{\times}10^{-4}M$ and the correlation coefficient of the calibration curve for each metal of magnesium and calcium in tap water. Alkaline earth metals were determined with the conventional high performance liquid chromatographic system.

  • PDF

Naphthalene Trisulfonic Acid 및 Naphthalene Disulfonic Acid을 이용한 음이온 간접자외선흡광검출 이온크로마토그래피 (Ion Chromatography of Anions with Indirect UV-Photometric Detection by using Naphthalene Trisulfonic Acid and Naphthalene Disulfonic Acid as an Eluent)

  • 이광필;전휘경;서현경;권세목;박긍식
    • 분석과학
    • /
    • 제12권2호
    • /
    • pp.111-115
    • /
    • 1999
  • 간접자외선흡광검출 이온크로마토그래피를 7가지 음이온($H_2PO_4^-$, $Cl^-$, $NO_2^-$, $NO_3^-$, $I^-$, $SO_4^{2-}$, $SCN^-$)분리에 적용하였다. 컬럼은 저용량의 강염기성 음이온 교환체를 가진 상용화된 TSK-guardgel QAE-SW (ca. 0.3 meq./g; 4.6 mm i.d${\times}$150 mm)를 사용하였다. 선택적이고 신속한 이온분리방법을 연구하기 위하여 naphthalene trisulfonic acid(NTS) 및 naphthalene disulfonic acid(NDS) 용리액에 대한 분리거동을 조사하였다. 더 나아가, 0.20 mM NTS 용리액에 5% 아세토리트릴을 첨가하여 음용수에 적용한 결과, 양이온과 음이온을 동시에 분리 할 수 있었다.

  • PDF

BRACKETT LINE-BASED MBH ESTIMATORS AND HOT DUST TEMPERATURES OF TYPE 1 AGNs FROM AKARI SPECTROSCOPIC DATA

  • KIM, DOHYEONG;IM, MYUNGSHIN
    • 천문학논총
    • /
    • 제30권2호
    • /
    • pp.443-445
    • /
    • 2015
  • We provide results of near-infrared (NIR) spectroscopic observations of 83 nearby (0.002< z <0.48) and bright (K <14 mag) type 1 active galactic nuclei (AGNs). For the observations, we used the Infrared Camera (IRC) on AKARI allowing us to obtain the spectrum in the rarely studied spectral range of $2.5-5.0{\mu}m$. The $2.5-5.0{\mu}m$ spectral region suffers less dust extinction than ultra violet (UV) or optical wavelength ranges, and contains several important emission lines such as $Br{\beta}$ ($2.63{\mu}m$), $Br{\alpha}$ ($4.05{\mu}m$), and polycyclic aromatic hydrocarbon (PAH; $3.3{\mu}m$). The sample is selected from the bright quasar surveys of Palomar Green and SNUQSO, and AGNs with black hole (BH) masses estimated from reverberation mapping method. We measure the Brackett line properties for 11 AGNs, which enable us to derive BH mass estimators and investigate circum-nuclear environments. Moreover, we perform spectral modeling to fit the hot and warm dust components by adding photometric data from SDSS, 2MASS, WISE, and ISO to the AKARI spectra, and estimate hot and warm dust temperatures of ~1100K and ~220 K, respectively.

구상성단 M30의 UBVI CCD 측광연구 (UBVI CCD Photometry of the Globular Cluster M30)

  • 이호;전영범
    • 한국지구과학회지
    • /
    • 제27권5호
    • /
    • pp.557-568
    • /
    • 2006
  • 구상성단 M30의 $20'.5{\times}20'.5$ 영역에 대한 CCD UBVI 측광 관측을 수행하여 색-등급도로부터 주계열 전향점과 색지수 $V_{TO}=18.63{\pm}0.05,\;(B-V)_{TO}=0.44{\pm}0.05,\;(V-I)_{TO}=0.63{\pm}0.05$를 얻었으며, 색-색도로부터 $E(B-V)=0.05{\pm}0.01$과 중원소 함량의 지표인 UV 색 초과량 ${\delta}(U-B)=0.27{\pm}0.01$을 얻었다. 측광학적인 방법과 분광 관측 자료를 이용하여 중원소 함량 $[Fe/H]=-2.05{\pm}0.09$를 구하였다. 관측된 M30의 광도 함수는 이론적 모델에 비하여 전향점 부근에 비하여 적색 거성열의 초과 현상을 보였다. Hipparcos 위성에서 측정된 삼각 시차로부터 거리가 알려진 준왜성을 이용하여 주계열 맞추기를 하여 거리 지수 $(m-M)_o=14.75{\pm}0.12$를 구하였다. 헬륨 함량을 구하기 위하여 R과 R' 방법을 사용하여 $Y(R)=0.23{\pm}0.02,\;Y(R')=0.29{\pm}0.02$를 얻었다. 성단의 나이는 적용하는 방법과 모델에 따라서 10.7 Gyr에서 17 Gyr까지 분산을 보인다.

지르코늄 실리케이트를 응집보조제로 이용한 응집공정에 관한 연구 (A Study on Coagulation Process using Zirconium Silicate as a Coagulation-aid)

  • 조재성;윤태일;전유재;조경철
    • 대한환경공학회지
    • /
    • 제31권3호
    • /
    • pp.203-207
    • /
    • 2009
  • 최근 산업화에 따른 다양한 신종 미량유해물질의 등장과 지속적인 오염물질의 증가로 수질오염의 심각성과 그 위해성에 대한 관심이 커지고 있다. 특히 응집공정을 통하여 유기오염물질 제거를 좀 더 효율적으로 증가시킬 수 있는 방법들이 모색되고 있다. 본 연구는 도시하수 및 호소수를 대상으로 실험하였다. 응집공정에 사용하기 위해 응집 보조제로서 사용될 수 있는 지르코늄 실리케이트($ZrSiO_4$)의 특성을 연구 하였다. 응집공정에서의 지르코늄 실리케이트의 주입방법에 따른 유기물 제거율을 PDA (Photometric Dispersion Analyzer)를 통하여 평가하였다. 지르코늄 실리케이트는 pH 7에서 zeta-potential이 -32.22 mv였고 산성에 가까울수록 낮은 음(-)전하 값을 보였으며 지르코늄 실리케이트를 주입하지 않은 도시하수보다 주입하였을 때 $UV_{254}$ 값이 더 높은 특성을 나타내었다. 또한 PDA실험을 통하여 확인한 결과 지르코늄 실리케이트의 주입은 floc의 성장을 도와주는 것을 확인할 수 있었다. Alum을 이용한 응집공정에 대한 지르코늄 실리케이트의 주입방법을 선 주입, 동시 주입, 후 주입의 3가지 방법으로 실험을 수행하였다. 실험 결과 Alum과 지르코늄 실리케이트를 함께 주입한 경우 Alum을 단독으로 주입한 경우보다 유기물 제거율이 15% 이상 증가하였다. 특히 Alum 20 mg/L과 지르코늄 실리케이트 10 mg/L를 함께 사용한 경우 90% 이상의 높은 유기물제거율을 보였다. PAC (Poly Aluminium Chloride)와 PACS (Poly Aluminium Chloride Silicate)를 응집제로 이용하는 경우에도 지르코늄 실리케이트를 함께 주입 시 $COD_{Cr}$의 제거효율이 15% 이상 향상되었다. 결과적으로 지르코늄 실리케이트를 응집제와 동시에 주입한 방법이 전, 후로 주입한 경우보다 $COD_{Cr}$ 제거효율이 5~10% 높게 나타났으나, 용존성 물질은 시주입 시, 더 낮은 제거효율을 보였다.