• Title/Summary/Keyword: UV lamp

Search Result 273, Processing Time 0.028 seconds

Development of an UV Distribution Model for the Design of a Submerged UV Disinfection Reactor and Its Application (침지형 자외선 살균조 설계를 위한 자외선 분포 모델의 개발 및 적용)

  • Park, Changyeun;Kim, Sunghong;Choi, Younggyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.505-512
    • /
    • 2021
  • A 3D model was developed to calculate the UV intensity of a submerged-type UV disinfection reactor. Numerical experiments were conducted by inputting the design factors of an open channel-type disinfection reactor and a pipe-type disinfection reactor that were installed in an actual sewage treatment plant. The following data were obtained: The average UV intensity of the installed open channel-type reactor and pipe-type reactor was 7.87 mW/cm2 and 13.09 mW/cm2, respectively; the UV dose reflecting the UV irradiation time and taking into account attenuation effects such as mixing imbalance, lamp aging, temperature, and fouling, was expected to be 21.1 mJ/cm2 and 24.8 mJ/cm2, respectively, and these values are 5 % and 24 % higher than the target UV dose of 20 mJ/cm2, respectively. By using the UV3D model, the optimal lamp position, which maximizes the average UV intensity without changing the size of the disinfection reactor or lamp output power, can be found. In this case, by only adjusting the lamp position, the average UV intensity can be increased by 0.9 % for the open channel-type and 0.5 % for the pipe-type, respectively. A better average UV intensity can be obtained by model simulation. By adjusting the horizontal and vertical ratio of the open channel-type reactor and by moving the lamp position, the average UV intensity can be increased by 7.4 % more than the present case.

Fabrication of polymer tip on an optical fiber end-face by guided UV light (도파된 UV 빛에 의한 광섬유 단면의 폴리머 팁 제작)

  • Park, Min-Gyu;Jeong, Ho-Jung;O, Gyeong-Hwan
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2009.02a
    • /
    • pp.147-148
    • /
    • 2009
  • We have fabricated a down tapered polymer tip on optical fiber end-face by a guided UV light. One side of fiber was aligned with a mercury-xenon lamp and another was put into UV curable polymer. A shape of tip was controlled by adjusting an irradiance of lamp and time of exposure. A bending effect also affects the result. Optical characteristic was achieved preliminarily with solution of minute particles.

  • PDF

Strain-free AlGaN/GaN Nanowires for UV Sensor Applications (Strain-free AlGaN/GaN 자외선 센서용 나노선 소자 연구)

  • Ahn, Jaehui;Kim, Jihyun
    • Korean Chemical Engineering Research
    • /
    • v.50 no.1
    • /
    • pp.72-75
    • /
    • 2012
  • In our experiments, strain-free nanowires(NWs) were dispersed on to the substrate, followed by e-beam lithography(EBL) to fabricate single nanowire ultraviolet(UV) sensor devices. Focused-ion beam(FIB), micro-Raman spectroscopy and photoluminescence were employed to characterize the structural and optical properties of AlGaN/GaN NWs. Also, I-V characteristics were obtained under both dark condition and UV lamp to demonstrate AlGaN/GaN NW-based UV sensors. The conductance of a single AlGaN/GaN UV sensor was 9.0 ${\mu}S$(under dark condition) and 9.5 ${\mu}S$ (under UV lamp), respectively. The currents were enhanced by excess carriers under UV lamp. Fast saturation and decay time were demonstrated by the cycled processes between UV lamp and dark condition. Therefore, we believe that AlGaN/GaN NWs have a great potential for UV sensor applications.

A Study on Filter and Lamp of Blocking Fading Wavelength with Use of the Deposition (증착법을 이용한 퇴색파장 차단 필터 및 램프에 관한 연구)

  • Lim, Jong-Min;Yi, Chin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.47-56
    • /
    • 2010
  • For a human being's smooth activity, the clean air and comfortable lighting environment are needed. The suitable lighting environment is obtained generally by making it available for being formed the bright situation easy for seeing object and the visually comfortable atmosphere. In this way, even the lighting environment was changed along with economic development. Even a light source was diversified. Thus, several kinds of new light sources such as LED, OLED, PLS, and CNT came to appear. Halogen lamp, which has low efficiency due to high color rendering among lamps of being used now, is being much used yet. However, owing to radiation of UV and IR, there are many limitations to the subject in general exhibition lighting, museum, and art museum. Accordingly, a research was performed on filter that is blocked UV and IR at the same time, by using halogen lamp that is excellent in color rendering and in life.

Photooxidation of BR Vulcanizate Using High Pressure Mercury Lamp

  • Kim, Eunha;Choi, Sung-Seen
    • Elastomers and Composites
    • /
    • v.50 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • Polybutadiene rubber (BR) has been well known that its physical and chemical properties are changed when it is exposed to ultraviolet light undergoing photooxidation. In this study, photooxdiation process of BR vulcanizate was investigated using a high pressure mercury lamp used as an outdoor lighting, which has high UV radiation efficiency and reasonable cost. Discoloration and crack formation of photooxdized BR vulcanite surface were examined using an image analyzer. Change of chemical functional groups of BR vulcanite surface by photooxidation was investigated using ATR-FTIR, and variation of the crosslink density with the UV irradiation time was investigated. By increasing the UV irradiation time, the crosslink density steeply increased after a period of time and did not increase any more. Formation of hydroxyl (~OH) and carbonyl (~C=O) groups on the BR vulcanizate surface increased and the1,4-cis unit was converted to the 1,4-trans unit as the photooxidation was proceeded.

Characteristics of Micro-stereolithography Apparatus Using UV Lamp as Light Source (UV램프 광원 마이크로 광 조형장치의 성능평가)

  • Lee I.H.;Choi J.S.;Lee S.P.;Ko T.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.161-162
    • /
    • 2006
  • Micro-stereolithography technology is used for fabricating of 3-dimensional micro-structures. In some cases, this technology is more economical and simpler than MEMS and LIGA technologies based on semiconductor process. In this research, the micro-sterolithography apparatus that is more economical and simpler than current micro-stereolithography apparatus was developed. This apparatus uses UV lamp and optical fiber as a light source and tight delivery system, respectively.

  • PDF

WTP UV Disinfection System (국내하수처리장 자외선소독조 운영실태 및 기술동향)

  • Lee, J.Y.;Kim, Y.T.;Lee, T.J.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.126-132
    • /
    • 2005
  • UV disinfection system allows the disinfection of municipal and industrial water and wastewater without the use of expensive chlorination and dechlorination techniques, labor intensive equipments In traditional ultraviolet systems the UV lamps are seperated from water by quartz sleeves. quartz is one of. the few materials that is virtually transparent to UV light, the UV lamp is placed inside the Quartz sleeve. UV light from the lamp is passed through the quartz and into the water, thereby providing disinfection. In fluoropolymer tube-used non-contact UV systems, the water flows through fluoropolymer plastic tubes. banks of UV lamps surround these tubes such that each tube gets exposed to ultra violet light from all sides. in non-contact design the lamps operates at almost constant temperature. this design is extremly efficient in the utilization of UV energy and superior to conventional contact- systems.

  • PDF

Optical Ozone Monitor Using UV Source

  • Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.49-52
    • /
    • 2003
  • Two types of ozone monitors using UV absorption method were tried in consideration of cost of the monitor and precision in measuring. The high concentration ozone monitor for high concentration real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source, a photo multiplier tube as UV detector and signal processing unit for the most part. This structure could be very useful for low price high concentration ozone monitor due to simple system structure and fairly good monitoring characteristics. The developed system showed good linear output characteristics to ozone in the measuring concentration range of 0.05 and 2 wt.%. For accuracy ambient ozone monitoring in ambient in ppm level, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit in brief speaking was proposed our study for the first time in the world. The developed system showed good linearity and sensitivity in relative low measuring range between 10ppm and 10,000ppm, and showed some feasibility of high resolution ozone monitor using CCD array as photodetector.

  • PDF

Assessment of Advanced Oxidation Processes using Low and Medium-Pressure Lamps with H2O2 for Reclamation of Biologically Treated Wastewater Effluents (하수 2차 처리수 재이용을 위한 저압 및 중압 고도산화시스템의 성능평가)

  • Ahn, Kyu-Hong;An, Seok;Maeng, Seung-Kyu;Kim, Ki-Pal;Hong, Joon-Seok;Jung, Min-Woo;Kweon, Ji-Hyang;Ahmed, Zubair
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.17 no.4
    • /
    • pp.542-549
    • /
    • 2003
  • In the present study, the feasibility of $UV/H_2O_2$ systems was investigated using low and medium-pressure lamps on biologically treated wastewater effluents for secondary effluent reclamation. Two types of UV lamps were used as the light sources (a 39-W low-pressure mercury lamp and a 350-W medium-pressure mercury lamp). The results from these UV systems showed that the removal of organic compounds could be achieved in the contact time of longer than 30min (i.e., low UV doses). Efficiencies of color removal and disinfection were far better than those of organic matters measured as TOC, DOC and $TCOD_{cr}$. In the low-pressure lamp UV system, it has been found that DOC and color removals were 60.9 and 86.2% with 50mg/L of $H_2O_2$ and contact times of 30 minute, respectively. Whereas, with the medium-pressure lamp UV system, TOC, DOC and color removal were 27.1, 5.6 and 95% with 14.3mg/L of $H_2O_2$ and 14 minute of contact times, respectively. Both systems could be applied for the reclamation of secondary effluent treated with biological treatment processes.