• Title/Summary/Keyword: UV detection

Search Result 548, Processing Time 0.036 seconds

Determination of Total Chlorine Residuals by Flow Injection Analysis (흐름 주입 분석법에 의한 총 잔류염소의 정량)

  • Choi, Yong Wook
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.4
    • /
    • pp.430-437
    • /
    • 1999
  • The determination of total chlorine residuals in drinking water by flow injection analysis(FIA) with iodometric UV detection was investigated. The pH of the acid stream, the concentration of the iodide ion,the length of the mixing and reaction coils, the injection sample size, and flowrate were optimized as parameters for determining total chlorine residuals by FIA method. lodide was selectively oxidized to iodine by hypochlorite at pH 8.3 Ethylenediamine as masking agent for masking interference ions from the sample was given the best efficency. Calibration curve presented linear range of 0.03-3 mg/L for hypochlorite ion with a correlation coefficient of 0.999 or better. The detection limit was found to be 0.007 mg/L for hypochlorite ion. Under these analytical conditions, total chlorine residuals in several tap water sampled in the city of Jeonju were analyzed.

  • PDF

Detection and Analysis of DNA Hybridization Characteristics by using Thermodynamic Method (열역학법을 이용한 DNA hybridization 특성 검출 및 해석)

  • Kim, Do-Gyun;Gwon, Yeong-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.6
    • /
    • pp.265-270
    • /
    • 2002
  • The determination of DNA hybridization reaction can apply the molecular biology research, clinic diagnostics, bioengineering, environment monitoring, food science and application area. So, the improvement of DNA hybridization detection method is very important for the determination of this hybridization reaction. Several molecular biological techniques require accurate predictions of matched versus mismatched hybridization thermodynamics, such as PCR, sequencing by hybridization, gene diagnostics and antisense oligonucleotide probes. In addition, recent developments of oligonucleotide chip arrays as means for biochemical assays and DNA sequencing requires accurate knowledge of hybridization thermodynamics and population ratios at matched and mismatched target sites. In this study, we report the characteristics of the probe and matched, mismatched target oligonucleotide hybridization reaction using thermodynamic method. Thermodynamic of 5 oligonucleotides with central and terminal mismatch sequences were obtained by measured UV-absorbance as a function of temperature. The data show that the nearest-neighbor base-pair model is adequate for predicting thermodynamics of oligonucleotides with average deviations for $\Delta$H$^{0}$ , $\Delta$S$^{0}$ , $\Delta$G$_{37}$ $^{0}$ and T$_{m}$, respectively.>$^{0}$ and T$_{m}$, respectively.

Properties and Activitiy Screening of Chromone Derivatives (크로몬 유도체의 물성 및 활성검색)

  • 김영로;이상현;김경순;정춘식;정재훈;김박광
    • YAKHAK HOEJI
    • /
    • v.44 no.2
    • /
    • pp.107-114
    • /
    • 2000
  • We have synthesized 4-isonitroso-4H-1-benzopyran and 4-amino-2,3-dihydro -4H-1-benzopyran of chromone derivatives by using condensation method. Physico-chemical properties of these compounds were measured and analyzed by UV and HPLC method. The correlation coefficient of their methanol solutions by UV were 0.9992 and 0.9994, respectively. And oxime compound was resolved within 4 min and had a detection limit of 3 ng at S/N=3 by HPLC using a reversed phase column with three solvents(MeOH, $H_2O$, HAc). The amino compound was resolved within 4.5 min and had a detection limit of 10 ng at S/N=3 by HPLC under the same conditions. Anti-diabetic effect of chromone derivatives were investigated in the streptozotocin (STZ)-induced diabetic rats. Diabetes was induced in male Sprague-Dawley rats by injections of STZ (45 mg/kg, i.v). The investigation of the hair growth effect of isonitrosobenzopyran and 4-aminobenzopyran on the hair of black mouse (C57BL/6) was also carried out. The administraion of their ethanol solution to the black mouse (C57BU/6) through skin them promoted the growth of hair.

  • PDF

HPLC Method for Simultaneous Quantitative Detection of Quercetin and Curcuminoids in Traditional Chinese Medicines

  • Ang, Lee Fung;Yam, Mun Fei;Fung, Yvonne Tan Tze;Kiang, Peh Kok;Darwin, Yusrida
    • Journal of Pharmacopuncture
    • /
    • v.17 no.4
    • /
    • pp.36-49
    • /
    • 2014
  • Objectives: Quercetin and curcuminoids are important bioactive compounds found in many herbs. Previously reported high performance liquid chromatography ultraviolet (HPLC-UV) methods for the detection of quercetin and curcuminoids have several disadvantages, including unsatisfactory separation times and lack of validation according the standard guidelines of the International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use. Methods: A rapid, specific, reversed phase, HPLC-UV method with an isocratic elution of acetonitrile and 2% v/v acetic acid (40% : 60% v/v) (pH 2.6) at a flow rate of 1.3 mL/minutes, a column temperature of $35^{\circ}C$, and ultraviolet (UV) detection at 370 nm was developed. The method was validated and applied to the quantification of different types of market available Chinese medicine extracts, pills and tablets. Results: The method allowed simultaneous determination of quercetin, bisdemethoxycurcumin, demethoxycurcumin and curcumin in the concentration ranges of $0.00488-200{\mu}g/mL$, $0.625-320{\mu}g/mL$, $0.07813-320{\mu}g/mL$ and $0.03906-320{\mu}g/mL$, respectively. The limits of detection and quantification, respectively, were 0.00488 and $0.03906{\mu}g/mL$ for quercetin, 0.62500 and $2.50000{\mu}g/mL$ for bisdemethoxycurcumin, 0.07813 and $0.31250{\mu}g/mL$ for demethoxycurcumin, and 0.03906 and $0.07813{\mu}g/mL$ for curcumin. The percent relative intra day standard deviation (% RSD) values were $0.432-0.806{\mu}g/mL$, $0.576-0.723{\mu}g/mL$, $0.635-0.752{\mu}g/mL$ and $0.655-0.732{\mu}g/mL$ for quercetin, bisdemethoxycurcumin, demethoxycurcumin and curcumin, respectively, and those for intra day precision were $0.323-0.968{\mu}g/mL$, $0.805-0.854{\mu}g/mL$, $0.078-0.844{\mu}g/mL$ and $0.275-0.829{\mu}g/mL$, respectively. The intra day accuracies were 99.589%-100.821%, 98.588%-101.084%, 9.289%-100.88%, and 98.292%-101.022% for quercetin, bisdemethoxycurcumin, demethoxycurcumin and curcumin, respectively, and the inter day accuracy were 99.665%-103.06%, 97.669%-103.513%, 99.569%-103.617%, and 97.929%-103.606%, respectively. Conclusion: The method was found to be simple, accurate and precise and is recommended for routine quality control analysis of commercial Chinese medicine products containing the flour flavonoids as their principle components in the extracts.

Determination of Cyhalofop-butyl and its Metabolite in Water and Soil by Liquid Chromatography (LC를 이용한 물과 토양 중 Cyhalofop-butyl과 대사물질의 분석)

  • Hem, Lina;Choi, Jeong-Heui;Liu, Xue;Khay, Sathya;Shim, Jae-Han
    • The Korean Journal of Pesticide Science
    • /
    • v.12 no.4
    • /
    • pp.315-322
    • /
    • 2008
  • In this study, a simple, effective, and sensitive method has been developed for the quantitative residue analysis of cyhalofop-butyl and its metabolite cyhalofop acid in water and soil when kept under laboratory conditions. The content of cyholofop-butyl and cyhalofop acid in water and soil was analyzed by first purifying the compounds through liquid-liquid extraction and partitioning followed by Silica gel (adsorption) chromatography. Upon the completion of the purification step the residual levels were monitored through high-performance liquid chromatography (HPLC) using a UV absorbance detector. The recoveries of cyhalofop-butyl from three replicates spiked at two different concentrations ranged from 82.5 to 100.0% and from 66.7 to 97.9% in water and soil, respectively. The limit of detection and minimum detection level of cyhalofop-butyl in water and soil was 0.02 ppm and 10 ng, respectively. The recoveries of cyhalofop acid ranged from 80.7 to 104.8% in water and from 76.9 to 98.1 % in soil. The limit of detection of cyhalofop acid was 0.005 ppm in water and 0.01 ppm in soil, while the minimum detection level was 2 ng both in water and soil. The half-live of cyhalofop-butyl was 4.14 and 6.6 days in water and soil, respectively. The method was successfully applied to evaluate cyhalofop-butyl residues in water and soil applied aj. 30% emulsion, oil in water (EW) product.

"Turn-on" type colorimetric/fluorimetric probe for selective detection of Cu2+ at neutral pH condition

  • Lee, Hyun Jung;Saleem, Muhammad;Lee, Ki Hwan
    • Rapid Communication in Photoscience
    • /
    • v.4 no.4
    • /
    • pp.88-90
    • /
    • 2015
  • The design and development of fluorescent chemosensors have recently been intensively explored for sensitive and specific detection of environmentally and biologically relevant metal ions in aqueous solution and living cells. Herein, we report the photophysical results of rhodamine B based fluorogenic and chromogenic receptor for selective copper detection in the complete organic or mixed aqueous-organic media at neutral pH under ambient condition. The ligand exhibited the remarkable increment in the fluorescence emission and UV-visible absorption signal intensities at 587 and 547 nm, respectively, on induction of copper ion while the ligand solution remain completely silent on addition of varieties of other metal ions.

Detection of Simazine, Atrazine and Ametryn Herbicides on a Microfluidic Chip Based on CE-AD (CE-AD기반의 Microfluidic chip을 이용한 Simazine과 Atrazine 그리고 Ametryn Herbicides의 검출)

  • Islam, Kamrul;Jang, You-Cheol;Chand, Rohit;Jha, Sandeep Kumar;Kim, Yong-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1688-1689
    • /
    • 2011
  • A simple and rapid capillary electrophoresis method was developed for the quantitative analysis of common triazine herbicides. Cyclic voltammetry was employed to clarify the detection voltage which showed characteristic irreversible cathodic peaks. For the analysis, the mixture of triazine herbicides was applied in a microfluidic chip to determine the CE-separated peaks. Soil sample extracts were analyzed directly after drying and redissolution with the supporting electrolyte but without other pretreatment. The results were comparable to those obtained by HPLC with UV detection. Therefore, this method can be used in the rapid determination of pesticide/herbicide residues.

  • PDF

$NO_2$ Gas Detection Characteristics of Langmuir-Blodgett Films layered with Dilithium phthalocyanine($Li_2Pc$) (유기 초박막의 가스 특성에 관한 연구)

  • Cho, H.K.;Yoo, B.H.;Kim, H.S.;Kim, T.W.;Kim, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1298-1300
    • /
    • 1994
  • An ability of $NO_2$ gas detection has been investigated using dilithium phthalocyanine($Li_2Pc$) Langmuir-Blodgett (LB) films. It is a well-known gas sensitive material and has been manufactured under a surface pressure of 30mN/m. A status of deposited films was confirmed by UV-visible absorption spectrum, ellipsometry measurements and current-voltage characteristics. Gas-detection characteristics of the films were studied through an electrical conductivity, response time, recovery time, and reproducibility under 200 ppm of $NO_2$ gases.

  • PDF

Analysis of Inorganic Anions in Various Drinking Waters by Capillary Electrophoresis

  • Choi, One-Kyun;Cho, Jae-Sun
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.835-841
    • /
    • 1995
  • The quantitation of inorganic anions in various drinking waters were investigated using capillary electrophoresis(CE) and the results were compared with ion chromatography(IC). With CE, in contrast to IC, was demonstrated rapid analysis, good efficiency, a low detection limit and the low comsumption of a solvent and samples. CE analysis was used 5 mM sodium chromate(pH 8.0) containing 20 mM tetraalkylammoniumbromide at -25kV applied voltage with indirect UV detection at 254 nm. This results in exceedingly short analysis time within 3 min. with efficiencies approaching 200,000 theoretical plates. The coefficients of variants of migration time are less than 0.8% and those of peak area are less than 2.3%. Detection limits for quantitative determination were 300 ppb-50 ppm level. These optimum conditions are applicable to various samples without pretreatment.

  • PDF

A Educational Study on Detection of Fluoride by Borane Compounds (보레인 화합물을 이용한 불소 이온 검출에 관한 교육 연구)

  • Lee, Kang Mun
    • Korean Educational Research Journal
    • /
    • v.37 no.1
    • /
    • pp.33-45
    • /
    • 2016
  • We propose a research for detection of the fluoride ion using borane compounds. Based on the Lewis acid-base reaction, we discussed the fundamental of sensing for fluoride ion. One of the important aspects in the chemistry of organoboranes is their behaviors as Lewis acids, which is a result of the vacant $2p_{\pi}$ orbital on the tricoordinate boron center. The electronic interaction between boron atoms and ${\pi}$-orbitals of donor molecules, constructed from the carbon 2p orbitals, is generally strong. Boron atoms can reach the desired octet configuration either through ${\pi}$-overlap with a suitable X or through formation of Lewis acid-Lewis base complexes.

  • PDF