• Title/Summary/Keyword: UV살균

Search Result 179, Processing Time 0.029 seconds

The Inactivation Effects of UV Light on Bacteriophage f2 (박테리오파지 f2에 대한 자외광선의 살균효과)

  • Kim, Chi-Kyung;Quae Chae
    • Microbiology and Biotechnology Letters
    • /
    • v.11 no.3
    • /
    • pp.155-161
    • /
    • 1983
  • The effects of ultraviolet light on bacteriophage f2 were investigated to determine the inactivation kinetics and its mechanism. The 260nm light showed a little higher inactivation rate than the one of 300 nm. In this work, our main concern was whether structural and/or conformational changes in the protein capsid could occur by UV irradiation. The inactivation for the first 20 minutes irradiation was rapid with a loss of about 4 logs and followed by a slower rate during the next 40 minutes with no survival noted in the samples irradiated for 90 minutes or longer. The structural change of the protein capsid was examined by optical spectroscopic techniques and electron microscopy. The absorption spectra of the UV irradiated phages showed no detectable differences in terms of the spectral shape and intensity from the control phage. However, the fluorescence emission spectroscopic data, i.e. 1) fluorescence quenching of tryptophan residues upon irradiation of 300 nm light, 2) enhancement of fluorescence emission of ANS (8-aniline-1-naphthalene sulfonate) bound to the intact phages compared to the one in the UV-treated phages, and 3) decrease of energy transfer efficiency from tryptophan to ANS in the UV-treated samples, presented remarkable differences between the intact and UV-treated phages. Such a structural alteration was also observed by electron microscopy The UV-treated phages appeared to be broken and empty capsids. Therefore, the inactivation of the bacteriophage f2 by UV irradiation is thought to be attributed to the structural change in the protein capsid as well as damage in the viral RNA by UV irradiation.

  • PDF

Microbial reduction effect of steam heating, UV irradiation, and gamma irradiation on red pepper powder (스팀 가열 및 자외선, 감마선 조사 처리에 따른 고춧가루의 미생물 저감화 효과)

  • Choi, Jun-Bong;Cheon, Hee Soon;Chung, Myong-Soo;Cho, Won-Il
    • Korean Journal of Food Science and Technology
    • /
    • v.52 no.2
    • /
    • pp.177-182
    • /
    • 2020
  • This study evaluated the effect of steam heating, gamma irradiation, and ultraviolet (UV) irradiation on microorganism reduction in order to determine an effective sterilization method for red pepper powder. The effect of each treatment on the reduction of thermoduric bacteria and total aerobic bacteria in red pepper powder were as follows: 10 kGy gamma irradiation, reduction of 4 log and 6 log CFU/g, respectively; 12 mW/㎠ UV irradiation (264 nm UV-C), reduction of less than 1 log CFU/g; steam heating at 120℃ for 40 s, reduction of approximately 2 log CFU/g. High-temperature short-time processing at 110℃ for 30 s reduced the total bacterial count in Gochujang solution from 5.70 log CFU/g to 2.26 log CFU/g; at 121℃, the solution was commercially sterile. Steam heating resulted in 1, 2, and 4 log microbial inactivation in garlic, onion, and pepper powder, respectively. Steam sterilization, which consumers prefer over other methods, may be an effective method for reducing microorganisms in spice powders, including those in red pepper powder.

Survey of Preservatives and UV Filter Ingredients of Distributed Sunblock Products in Korea (국내 유통 자외선 차단 기능성화장품 중 살균보존제 및 자외선차단성분 사용실태조사)

  • Park, Jeong Hee;Kim, Jong Pil;Kim, Jin A;Seo, Kye Won;Kim, Eun Sun;Seo, Jumg Mi
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.43 no.4
    • /
    • pp.381-390
    • /
    • 2017
  • This study was conducted to determine 16 preservatives and 18 UV filter ingredients levels in 100 sunblock products. The order of detection rates of preservatives was phenoxyethanol (n=61), benzoic acid (n=19), methyl paraben (n=11), benzyl alcohol (n=8), propyl paraben (n=7). Also the order of detection rates of UV filter ingredients was titanium dioxide (n=81), ethylhexyl methoxycinnamate (n=69), zinc oxide (n=48), ethylhexyl salicylate (n=48), bis-ethylhexyloxyphenol methoxyphenyltriazine (n=44). The content of the detected preservatives and UV filter ingredients was within maximum allowed amount established by KFDA. In addition, preservatives and UV filter ingredients, which were not labeled in the products, were detected in 31 and 2 products respectively.

전해질 무첨가 전기/UV 공정을 이용한 염료의 제거

  • Park, Yeong-Sik;Kim, Dong-Seok
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2008.11a
    • /
    • pp.350-354
    • /
    • 2008
  • 전기/UV 공정에 사용하기 위해 일반적인 살균 램프인 UV-C 램프와 오존도 같이 발생하는 오존 등의 RhB 분해능을 고찰한 결과 오존 램프의 RhB 제거율이 UV-C램프보다 높은 것으로 나타났다. 전해질을 첨가하지 않은 전기/UV 공정에서 최적 전류는 1 A로 나타났다. 전기/UV 공정에서 RhB 제거의 경우 전기분해 공정과 UV 공정의 단일 공정의 RhB 농도감소와 전기/UV 복합 공정의 RhB 제거는 같아 공정의 시너지 효과는 관찰되지 않았다. 그러나 COD의 경우 전기분해 공정과 오존 램프에 의한 단일 공정의 COD 제거보다는 전기/UV 공정의 COD 제거농도가 높아 시너지 효과가 나타나는 것으로 사료되었다.

  • PDF

Ultraviolet Lamp Replacement Period and Hygiene Management Plan of Ultraviolet Sterilizer (자외선 살균고의 자외선 램프 교체 주기와 위생관리 방안)

  • Young-Ju Lee;Ju-Hyun Lee;Eun-Sol Go;Jung-Beom Kim
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.1
    • /
    • pp.26-30
    • /
    • 2023
  • In this study, we analyzed the microbial contamination level of ultraviolet sterilizer (UVS) chambers and suggested plans to improve hygiene management. In this study, UVS chambers targeted 98 UVS in some childcare centers in Jeollanam-do, Korea. Total aerobic bacteria and coliform bacteria were tested according to the Korean Food Code. Of the 98 UVS chambers, total aerobic bacteria were detected in 67 (68.4%) and coliform bacteria in 5 (5.1%). Six kinds of food-poisoning bacteria, including Salmonella spp., were not detected, but Bacillus cereus was detected in 1 (2.8%) out of 98 UVS chambers. According to the UV lamp replacement period, the detection rate of total aerobic bacteria was 3 (50%) out of 6 UVS within 3 months, 3 (60%) out of 5 UVS in 3 to 6 months, and 61 (70.1%) out of 87 UVS over 6 months. The detection rate of coliform bacteria according to the UV lamp replacement period was not detected within 6 months, however, they were detected in 5 (5.7%) out of 87 chambers after more than 6 months. The level of microbial contamination in the UVS chambers was higher as the lamp replacement period was longer. Considering these results, it was determined that the UVS chambers should be kept dry and clean, and the UV lamp should be replaced periodically. In addition, it is necessary to provide the staff catering for childcare centers with continuous education regarding the cleaning of UVS chambers and the replacement of UV lamps.

Effect of Various Sterilization Methods on Growth of Microorganism Contaminated in Ginseng Powder (여러 가지 살균방법이 인삼분말에 오염된 미생물의 성장에 미치는 영향)

  • 곽이성;장진규
    • Journal of Food Hygiene and Safety
    • /
    • v.16 no.3
    • /
    • pp.221-226
    • /
    • 2001
  • Various sterilization methods were applied to the powder of ginseng for the improving hygienic quality. Ultra-violet (UV) and Infrared ray (IR) treatments could not inhibit highly growth of bacteria in ginseng powder. However, high hydrostatic pressure treatment showed high inhibition rate against bacterial growth in ginseng powder. Changes of viable cell count by the pressure showed positive relationship between growth inhibition rates and the pressures applied. When powder was treated with 2,000 kg/$\textrm{cm}^2$ for 10 min at $25^{\circ}C$, initial viable cell count of the powder, 2.0$\times$10$^4$CFU/g, was decreased to 1.0$\times$10$^4$CFU/g. When it treated with 3,000, 4,000 and 5,000 kg/$\textrm{cm}^2$ of pressures under the same condition, viable cell counts were 8.0$\times$10$^3$, 7.0$\times$10$^3$and 1.8$\times$ 10$^3$CFU/g, respectively. Ginseng saponins of the powders were all detected when analyzed by TLC chromatography after treatment with the Pressures. Therefore, it was considered that saponin of ginseng powder was stable under the condition of 5,000 kg/$\textrm{cm}^2$ of pressure, even though the treatment induced coagulation of the powder.

  • PDF

Study of the Limitation Standards Setting of Sterilization Processing to Vagetable Juice Contain Barley Sprout (보리새싹 함유 녹즙의 살균공정 한계기준 설정에 관한 연구)

  • Bang, In-Hee;Joung, Mi-Yeun;Kwon, Sang-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.367-373
    • /
    • 2016
  • This study was performed to set a limitation rule to the UV sterilization process for green vegetable juice containing barley sprouts. The main constituents of the green vegetable juice, viz. barley sprouts, organic Angelica keiskei, carrots, organic dandelion, kale, wild parsley, Angelica keiskei and cabbage, were provided by the CSJ company located in Jincheon, Chungbuk, from December 1st, 2015 to March 1st, 2016. Our manufacturing process followed the general manufacturing process of a general green vegetable juice manufacturer. Table 1 shows the mixing ratio for the green vegetable juice. This green vegetable juice includes 18% vegetable sprouts, 3% barley sprouts, 18% angelica utilis makino, 1% orange concentrate, 4% apple concentrate, 6% fructooligosaccharide, 10% vegetable fermentation juice, 0.4% lemon concentrate and 39.6% purified water. We conducted UV sterilization at levels 10, 8 and 5 with powers of 230W, 320W and 320W, respectively. The UV sterilization was conducted twice at 25Hz and then once at 40Hz. In the bacterial tests after sterilization, the number of bacteria in the dandelions decreased from $2.56{\times}10^8CFU/mL$ to $5.96{\times}10^3CFU/mL$. In addition, no food poisoning or coliform bacteria were detected. Thus, this study provides the information required for setting a limitation rule using bacteria tests in the UV sterilization process for green vegetable juice.

Photocatalytic Efficiency of Anatase TiO$_2$Thin Film by Reactive Sputtering (Anatase TiO$_2$박막의 미세조직이 광촉매 효과에 미치는 영향)

  • Choe, Yong-Rak;Kim, Seon-Hwa
    • Korean Journal of Materials Research
    • /
    • v.11 no.7
    • /
    • pp.537-544
    • /
    • 2001
  • Anatase $TiO_2$thin films as a photocatalyst were prepared by the reactive magnetron sputtering process. The $TiO_2$thin films were deposited on Si substrates under the various conditions : oxygen partial pressure, working pressure, sputtering time, and D.C. power. The photocatalystic degradation of $TiO_2$thin film have been studied to examine the contribution of surface morphology and crystallinity. The thin films with a good crystallinity or a rough surface showed a high photocatalytic degradation rate on phenol and E.coli 078 experiment. Compared with that of only UV radiation, the photocatalytic efficiency of $TiO_2$thin film under the UV radiation and the $O_2$ flow increased. We found that the crystallity and the morphology were the important factors on the photocatalytic efficiency of TiO$_2$thin film.

  • PDF

Evaluation and Reduction of Microbiological Hazard of Spoon and Spoon Case Carried by Nursery School Children (어린이집 유아 휴대 수저 및 수저집의 미생물학적 위해 분석 및 저감화)

  • Kim, Jung-Beom;Park, Yong-Bae;Kim, Ki-Cheol;Kim, Dae-Hwan;Kang, Suk-Ho;Lim, Young-Sik;Park, Po-Hyun;Yoon, Mi-Hye;Lee, Jong-Bok
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.1
    • /
    • pp.116-122
    • /
    • 2011
  • This study was conducted to investigate the microbiological hazard of spoons and their cases carried by nursery school children and to evaluate the reduction effects of washing methods and ultraviolet (UV) treatments against Escherichia coli on the spoon and spoon case. A total of 78 spoons and their cases were sampled to test about total aerobic bacteria, coliform bacteria, Staphylococcus aureus, Bacillus cereus and Salmonella spp. Total aerobic bacteria were detected over 2.7 log CFU/100 $cm^2$ in 20 out of 36 spoons (55.6%), 9 out of 20 zipper-type spoon cases (45.0%) and 13 out of 22 plastic-type spoon cases (59.1%). Coliform bacteria were also detected in 19 out of 36 spoons (52.8%), 14 out of 20 zipper-type spoon cases (70.0%) and 14 out of 22 plastic-type spoon cases (63.6%). The pathogens tested in this study were not found in all samples except for the zipper-type spoon cases which were contaminated with Staph. aureus (2 samples) and B. cereus (3 samples). The results indicated that the sanitary conditions of spoons and their cases should be improved promptly. To evaluate the reduction effects of washing methods and UV treatments against E. coli, the spoons and their cases were treated at different cleaning times with and without soap, and different UV exposure times, respectively. E. coli with initial cell number of 4 log CFU on the spoons and their cases was not detected when they were cleaned at running water for 30 sec after dish sponging with soap for 30 sec. In UV treatments, E. coli with the same level of washing method was not detected after UV exposure for 15 minute in the spoons and their cases. From the results, the washing and UV treatment should be used to control the microbial contamination of spoons and their cases for more than 1 and 15 minutes, respectively.