• 제목/요약/키워드: UV/ozone

검색결과 255건 처리시간 0.024초

Optical Ozone Monitor Using UV Source

  • Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.49-52
    • /
    • 2003
  • Two types of ozone monitors using UV absorption method were tried in consideration of cost of the monitor and precision in measuring. The high concentration ozone monitor for high concentration real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source, a photo multiplier tube as UV detector and signal processing unit for the most part. This structure could be very useful for low price high concentration ozone monitor due to simple system structure and fairly good monitoring characteristics. The developed system showed good linear output characteristics to ozone in the measuring concentration range of 0.05 and 2 wt.%. For accuracy ambient ozone monitoring in ambient in ppm level, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit in brief speaking was proposed our study for the first time in the world. The developed system showed good linearity and sensitivity in relative low measuring range between 10ppm and 10,000ppm, and showed some feasibility of high resolution ozone monitor using CCD array as photodetector.

  • PDF

오존, UV, 오존/UV 혼합 공정을 이용한 Diethyl Phthalate(DEP)의 제거특성 연구 (Characterization of Diethyl Phthalate(DEP) Removal using Ozone, UV, and Ozone/UV Combined Processes)

  • 정연정;오병수;강준원
    • 대한환경공학회지
    • /
    • 제28권2호
    • /
    • pp.137-143
    • /
    • 2006
  • 본 연구는 오존 단독, UV 단독 및 오존/UV 혼합 공정을 이용하여 DEP의 제거 특성을 알아보고자 수행되었다. 실험 결과로서, 오존/UV 공정에서 가장 높은 제거 효율을 나타냈다. 오존 및 오존/UV 공정에서 DEP의 분해 경로를 파악하기 위해서 pH 변화 및 OH 라디칼($OH^{\circ}$) scavenger 첨가 유무에 따른 제거 정도를 비교하였다. 그 결과, DEP 분해 시 $OH^{\circ}$과의 반응이 주된 반응이며, 오존에 의한 직접 산화 반응 및 UV에 의한 광분해 반응은 무시할 정도로 작았다. 오존 및 오존/UV 공정에서 DEP의 의사일차속도상수를 비교하였을 때, 오존/UV 공정은 일차속도에 잘 일치한 반면 오존 단독 공정에서는 일차속도로 제거되는 경향이 초기에 빠르고 일정한 반응시간 이후에 느려지는 두 영역으로 나뉘어 나타났다. 오존 및 오존/UV 긍정에 의해 생성되는 DEP 산화 부산물을 간접적으로 확인하기 위해 HPLC 스펙트럼을 조사한 결과 미지의 물질이 검출되었으며, 반응시간에 따라 이 물질이 생성되다가 감소하는 일정한 경향을 보였다. 또한, 오존/UV 혼합공정에서 높은 TOC 제거율을 나타내 DEP 및 DEP 산화부산물까지 완전 산화됨을 확인하였다.

UV/Ozone 처리를 통한 Polydimethylsiloxane(PDMS) 주름 구조의 물리화학적 특성 분석 (Physicochemical Characteristics of UV/Ozone Treated Polydimethylsiloxane(PDMS) Wrinkle Structures)

  • 박홍규;박승엽
    • 한국정보전자통신기술학회논문지
    • /
    • 제15권5호
    • /
    • pp.321-327
    • /
    • 2022
  • 본 논문에서는 UV/Ozone 처리를 통해 Polydimethylsiloxane(PDMS) 표면에 주름 구조를 형성하고, 물리화학적 특성 분석을 통해 줄금 구조 형성 메커니즘을 밝혔다. 30분의 UV/Ozone 처리를 통해 PDMS 표면에 주름 구조를 형성하였으며, 주사전자현미경의 단면 촬영으로 PDMS 표면의 주기적인 주름 형성을 확인할 수 있었다. 또한, XPS 스펙트럼 분석을 통해 PDMS 표면에 SiOx의 실리카 경질 표면이 UV/Ozone에 의해 만들어지는 것을 확인하였고, PDMS 표면의 경질층과 내부의 연질층 사이의 탄성 계수 불일치는 PDMS의 주름 형성의 팽윤 메커니즘을 확인시켜 준다. 본 연구 결과는 UV/Ozone 처리에 의한 PDMS 표면의 주름 구조 형성 메커니즘의 이해도를 향상시킬 뿐만 아니라, 향후 UV/Ozone 조사 조건에 따라 주름 구조의 진폭과 주기를 조정하는데 기초 연구로 쓰일 수 있을 것이다.

UV/Ozone 복합 살균기의 살균력 개선 연구 (Improvement of a UV/Ozone Duplex Sterilizer)

  • 지정은;양원균;박은철;김강석;주정훈
    • 한국표면공학회지
    • /
    • 제41권2호
    • /
    • pp.76-82
    • /
    • 2008
  • We investigated sterilization characteristics of UV lights by counting the number of bacteria units with varying sterilization time and distance from the light source. We focused on an idea that UV light of 184.9 nm could generate ozone and developed a new sterilizer. The UV-ozone duplex system sterilized bacteria faster than UV-only sterilizers. To reduce shadowing effects by target objects, we used UV transparent quartz plate as a support and put a reflecting plate. Distribution of UV irradiation intensity and ozone supply were analyzed by a 3D model and measured by a semiconductor UV sensor. But even with an Al reflector, multi-layered pens could not be treated properly from UV irradiation only. Ozone generating lamp could treat more uniformly multi-layered pens with a stirring fan by supplying ozone to shadowed surfaces.

고급산화공정을 이용한 아세트아미노펜 분해 성능 비교 (Comparison of Acetaminophen Degradation Performance using Advanced Oxidation Process)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제31권4호
    • /
    • pp.319-328
    • /
    • 2022
  • This study investigated the treatment of acetaminophen in municipal wastewater by conventional ozonation, ozone-based advanced oxidation, ozone/UV, and the electro-peroxone process. The ozone/UV process and electro-peroxone process of electric power consumption increased 1.25 and 2.04 times, respectively, compared to the ozone process. The pseudo-steady OH radical concentration was the greatest in the electro-peroxone process and lowest in the ozone process. The specific energy consumption for TOC decomposition of the ozone/UV process and electro-peroxone process were 22.8% and 15.5% of the ozone process, respectively. Results suggest that it is advantageous in terms of degradation performance and energy consumption to use a combination of processes in municipal wastewater treatment, rather than an ozone process alone. In combination with the ozone process, the electrolysis process was found to be more advantageous than the UV process.

Bacillus Subtilis Spores 불활성화 실험을 통한 오존, UV 공정의 소독 특성 평가 (Evaluation of Disinfection Characteristics of Ozone, UV Processes for Bacillus Subtilis Spores Inactivation)

  • 정연정;오병수;강준원
    • 한국물환경학회지
    • /
    • 제22권4호
    • /
    • pp.672-677
    • /
    • 2006
  • Ozone/UV combined process is an effective technique to enhance generation of OH radical which is non-selective and powerful oxidant. The objective of this study is to evaluate the inactivation rates of B. subtilis spores by three candidate processes (ozone alone, UV alone, ozone/UV combined processes) at 4 and $20^{\circ}$ and to investigate the effects of OH radical on inactivation of B. subtilis spores. On the UV alone process, required UV dosages for lag phase and 3-log inactivation of B. subtilis spores were determined as $8.9mJ/cm^2$ and $47mJ/cm^2$. However, the inactivation of B. subtilis spores didn't occured beyond 4.5-log inactivation despite increasing UV dose. The inactivation of B. subtilis spores by ozone alone and ozone/UV combined process was investigated with ozone CT (Concentration of disinfectant ${\times}$ Contact time) concept. As a result, inactivation of B. subtilis spores by ozone/UV combined process was faster than by ozone alone, and especially $CT_{lag}$ value B. subtilis spores in the presence and absence of t-BuOH, OH radical scavenger, was investigated to evaluate effects of OH radical formed during ozone/UV combined process. We found that OH radical plays important roles on inactivation of B. subtilis spores.

UV 감지기로서 CCD어레이를 사용한 소형 디지털 광 오존모니터 (A New Small Size Digital Optical Ozone Monitor Using CCD Array as a UV Detector)

  • 정완영;이승철
    • 한국정보통신학회논문지
    • /
    • 제12권1호
    • /
    • pp.158-163
    • /
    • 2008
  • UV기술에 기반한 오존모니터는 신호의 안정성 때문에 널리 활용되어오고 있다. 먼저 오존 발생기에서 나오는 오존농도를 실시간, 고정 밀로 측정하기 위해서 저압 수은램프를 UV광원으로 하고, 광증배관을 UV 감지기로 하는 시스템을 구성하였다. 이 구조는 저 비용의 고농도 오존의 계측에 유용한 시스템으로서 단순한 구조와 비교적 우수한 계측성 능을 얻을 수 있었다. 제조된 시스템은 $0.05{\sim}2w1.%$의 측정 농도영역에서 좋은 선형성을 나타내었다. ppm정도의 보다 정밀한 농도계측을 위해서는 UV광원으로서 고출력 펄스 크세논램프를 사용하고, CCD어레이를 광스펙트로메터로 사용하도록 시스템을 설계하였다. CCD출력으로부터의 광신호는 우수한 반응성과 띄어난 광해상도를 가지고 디지털신호로 변환되고, 이 디지털신호는 PC의 스크린에 디스플레이 되도록 설계되었다. 제작된 시스템은 $10{\sim}10,000ppm$ 영역에서 선형적이고 우수한 감도를 보였으며 저 농도의 오존을 측정하는 시스템으로서의 가능성을 보여주었다.

UV/오존에 의해 개질된 폴리프로필렌의 표면 조성 변화 (Surface Composition Change of UV/Ozone Modified Polypropylene)

  • 김재익;류승훈
    • Elastomers and Composites
    • /
    • 제37권1호
    • /
    • pp.49-56
    • /
    • 2002
  • UV 조사시간과 오존유량을 변화시키면서 폴리프로필렌을 UV/오존 산화하였으며 이의 표면특성을 접촉각과 XPS를 이용하여 살펴보았다. 산화된 표면의 노화거동을 공기, 물, 에틸렌 글리콜 하에서 살펴보았으며, 또한 lap shear 실험을 통하여 접착력을 관찰하였다. 극성표면 에너지와 접착력은 UV/오존 처리시간과 오존유량이 증가함에 따라 증가함을 알 수 있었다. 물에서 노화실험을 한 경우 극성표면 에너지의 변화가 없었으나, 공기 하에서 실시한 경우 2-3일 이내에 급격히 감소하여 처리하지 않은 폴리프로필렌의 값에 근접하였다.

Thermal Assisted UV-Ozone Treatment to Improve Reliability of Ag Nanoparticle Thin Films

  • Lee, Inhwa;Kim, Taek-Soo
    • 마이크로전자및패키징학회지
    • /
    • 제21권1호
    • /
    • pp.41-44
    • /
    • 2014
  • We employed UV-Ozone treatment method for the fabrication of dense and highly conductive nanoparticle thin films. We demonstrated the UV-Ozone treatment effect on the silver nanoparticle thin films as a function of time and temperature. The capping layers of nanoparticles were decomposed after UV-Ozone treatment and dense nanoparticle thin films were obtained. Moreover, electrical and mechanical properties of the thin films after UV-Ozone treatment were measured by using resistance measurements under tension in an in-situ tensile tester. The initial resistance of nanoparticle thin films was decreased by 82.6% with optimized UV-Ozone treatment condition of $150^{\circ}C$ for 20 minutes.

고급산화공정을 이용한 염료폐수의 처리기술 연구 (A Study on the Dye Wastewater Treatment by Advanced Oxidation Process)

  • 강태희;오병수;박세준;강민구;김종성;강준원
    • 한국물환경학회지
    • /
    • 제21권3호
    • /
    • pp.267-273
    • /
    • 2005
  • Dye wastewater generally contains strong color and non-biodegradable materials. Therefore, the conventional wastewater treatment plant can hardly meet the regulation of wastewater effluent water. In this study, a pilot plant of the conventional process followed by advanced oxidation process (AOP), was set up to treat the dying wastewater. The treatment efficiencies on the various candidate processes, such as ozone alone, UV alone, ozone/UV, $ozone/H_2O_2$, $H_2O_2/UV$ and $ozone/UV/H_2O_2$, were investigated in the various ozone and $H_2O_2$ doses. As the results, the $ozone/H_2O_2$ process, among the tested processes, showed the highest efficiency for removing color and $COD_{Cr}$. For color removal, the ozone alone process was enough without combining UV or $H_2O_2$. No significantly enhanced efficiency for removing color and $COD_{Cr}$ by UV irradiation was observed because of the very low transmittance of UV light in dye wastewater.