• 제목/요약/키워드: UTC(Unglazed Transpired Collector)

검색결과 3건 처리시간 0.017초

태양열 외기 난방 시스템의 열성능 시뮬레이션 및 검증 연구 (Solar Air Heating System Thermal Performance Simulation and Verification)

  • 강동언;이의준;현명택
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.152-157
    • /
    • 2001
  • UTC(Unglazed Transpired Collector) system has recently emerged as a new solar air heating technology. It is relatively inexpensive because it has not a glazed material. And it demonstrates efficient particularly for the applications in which larger wall area facilities with a high outdoor air requirement. Mathematical algorithm for UTC thermal modeling has been understood for further improvement of the system. EES and TRNSYS model of actual solar wall panel could be developed for computer simulations under other conditions. Computer models could be validated with the measured data from fixed outdoor test cell in KIER(Korea Institute of Energy Research). Major design parameters could be identified such as panel configuration and absorptivity and emissivity values for UTC design.

  • PDF

무창 기공형 태양열 공기 난방 모듈 성능 모니터링 연구 (Performance Monitoring Study of Unglazed Transpired Solar Air Heating Module)

  • 강은철;현명택;이의준
    • 한국태양에너지학회 논문집
    • /
    • 제22권1호
    • /
    • pp.67-72
    • /
    • 2002
  • Solar Air Systems (SAS) have unique advantages for space heating and tempering ventilation air. Air, unlike water, needs no protection against freezing nor are leaks damaging to the building structure or its contents. In contrast to glazed collector, unglazed steel solar collector may have higher efficiencies over glazed flat collector due to the absence of the glass. Therefore, the monitoring of SAS is so important to evaluate actual performance of SAS for right applications. This study is to provide a testing method with a movable test cell developed in KIER to evaluate the thermal performance of SAS based on international standard method ASHRAE 93-86, "Method of Testing to Determine the Thermal Performance of Solar Collectors". The monitoring tool used advanced technique LabVIEW 6i with portable notebook computer. Sample results have been obtained to access the performance of a reference and a target SAS module. The process and tool introduced here could be used to provide a performance verification data for future implementation study applications.

무창돈사 내 무창기공형 집열기 제어 시스템 개발을 위한 기초적 연구 (A Fundamental Study for Development of Unglazed Transpired Collector Control System in Windowless Pig House)

  • 문병은;김희태;김종구;유영선;김현태
    • 농업생명과학연구
    • /
    • 제50권2호
    • /
    • pp.175-185
    • /
    • 2016
  • 본 연구에서는 UTC 시스템을 대표적인 농업시설인 돈사에 적용하기에 앞서, UTC 제어 시스템 및 프로그램 개발에 따른 돈사 내 적정 사육 환경 유지 및 난방에너지 저감을 위한 기초자료로 활용하고자, 2동의 실험돈사를 제작, UTC 제어 시스템 적용에 따른 실험돈사 내부 온도 변화 및 에너지를 비교, 분석하였다. 제어 시스템은 T1~T4, 총 4점의 온도를 측정 후 프로그램 내 알고리즘에 의해 O1~O5, 총 5개의 출력 신호를 ON/OFF 방식으로 각각 제어하도록 구성하였다. 온도 설정은 실험돈사 내부 온도 28.0℃, UTC 내부 온도 34.0℃로 설정하였고, 측정된 온도와 비교를 통해 출력 신호를 제어하였다. 3일간, 제어 시스템을 가동한 돈사의 경우 최고 온도는 평균 31.8℃로 측정되었다. 같은 시간, 비교돈사의 최고 온도는 평균 36.6℃로 제어 시스템을 가동한 돈사의 내부 온도가 약 4.8℃ 낮은 것으로 나타났다. 또한 제어 프로그램의 가동에 따라 UTC 플레넘 최고 온도는 평균 50.5℃까지 상승한 것으로 나타났다.