• Title/Summary/Keyword: UT measurement

Search Result 39, Processing Time 0.034 seconds

Effect of Homemade Liquid Fertigation on Growth and Fruit Characteristics of Cherry Tomatoes (자가제조 액비 관주 처리가 방울토마토의 생장과 과실특성에 미치는 영향)

  • Jung, Ji-Sik;Jung, Seok-Kyu;Choi, Hyun-Sug
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.28 no.1
    • /
    • pp.27-36
    • /
    • 2020
  • The study was compared for growth and yield of cherry tomato (Lycopersicon esculentum var. cerasiforme) crops as affected by various homemade liquid fertilizer (LF), commonly applied in the environmentally friendly farmhouses. LF treatment included UT (untreatment, water), OC (oil cake), BF (bone+fish meal), FA (fish amino meal), SO (sesame oil meal), and SF (starfish). Seasonal pH and EC in SO- and SF-LF rapidly decreased at 30 days after the storage, which were the highest EC of 0.6 - 0.8 dS/m, followed by BF-LF with 0.4 dS/m EC. T-N concentration in LF was the highest on the SF (0.0062%), followed by SO (0.0059%) and BF materials (0.0030%), which were all the great for the K concentration in the LF. P and Ca concentrations were the highest on the FA-LF, with the highest Mg concentration observed on the vegetable SO-LF. Soil EC was the highest on the SF-LF plots of 0.74 dS/m, with no significant differences between the treatments observed on the macro-nutrient concentrations in the soil and leaf. Leaf dry weight, leaf temperature, stem diameter, and plant height were investigated at once per 15 days. UT-LF reduced the leaf dry weight at all the measurement time while the plant height was low at an initial measurement but increased and similar to the other homemade LF treatments at a later measurement. Fruit yield and average fruit weight were the lowest on the UT-LF plots at 75 days after fertigation. Fruit diameter was increased by the BF-LF and SF-LF, with the highest fruit soluble solid contents and fruit coloring observed on the FA-LF. BF-LF maintained high fruit firmness.

Reliability and validity of a personal computer based muscle viewer for measuring upper trapezius and transverses abdominis muscle thickness

  • Jeong, Ju-Ri;Han, Ju Hee;Cho, Ji-Eun;Lee, Wan-hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.3
    • /
    • pp.155-161
    • /
    • 2016
  • Objective: This study aimed to investigate the reliability and validity of a personal computer-based muscle viewer (PC-BMW) compared with that of a portable ultrasound (P-US) for measuring upper trapezius (UT) and transversus abdominis (TrA) muscle thickness at rest and during contraction. Design: Observational inter-rater reliability study. Methods: Fifty-five healthy participants (25 men, 30 women) participated in this study. PC-BMW and P-US were randomly measured at the UT and TrA muscles. Two examiners randomly obtained the images of all participants in 3 test sessions lasting 2 days. Intra-class correlation coefficients (ICCs), standard error of measurement, contraction ratio, and correlation were used to estimate reliability and validity. Pearson's correlation coefficients were used to analyze the relationship between muscle thickness measures taken from PC-BMW and P-US. Results: The intra-rater reliability ICCs of UT and TrA muscle thickness for the PC-BMW were >0.995, indicating excellent reliability. Inter-rater reliability ICCs for the PC-BMW ranged from 0.963 to 0.987. The P-US also exhibited high reliability. A high correlation was found between the measurements of the two muscles in PC-BMW and P-US (p<0.01). Conclusions: PC-BMW provides clear and excellent images, is pocket-sized and less expensive than a conventional ultrasound imaging system. PC-BMW can be utilized variously and has the advantage of rehabilitative ultrasound imaging. More research is needed to evaluate the utility of PC-BMW for rehabilitation.

Modelling on the Carbonation Rate Prediction of Non-Transport Underground Infrastructures Using Deep Neural Network (심층신경망을 이용한 비운송 지중구조물의 탄산화속도 예측 모델링)

  • Youn, Byong-Don
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.220-227
    • /
    • 2021
  • PCT (Power Cable Tunnel) and UT (Utility Tunnel), which are non-transport underground infrastructures, are mostly RC (Reinforced Concrete) structures, and their durability decreases due to the deterioration caused by carbonation over time. In particular, since the rate of carbonation varies by use and region, a predictive model based on actual carbonation data is required for individual maintenance. In this study, a carbonation prediction model was developed for non-transport underground infrastructures, such as PCT and UT. A carbonation prediction model was developed using multiple regression analysis and deep neural network techniques based on the actual data obtained from a safety inspection. The structures, region, measurement location, construction method, measurement member, and concrete strength were selected as independent variables to determine the dependent variable carbonation rate coefficient in multiple regression analysis. The adjusted coefficient of determination (Ra2) of the multiple regression model was found to be 0.67. The coefficient of determination (R2) of the model for predicting the carbonation of non-transport underground infrastructures using a deep neural network was 0.82, which was superior to the comparative prediction model. These results are expected to help determine the optimal timing for repair on carbonation and preventive maintenance methodology for PCT and UT.

Lamb Wave Inspection for Crack Detection in Coil Spring of Automobile Suspension System (자동차 현가 장치용 스프링의 신뢰성 평가를 위한 Lamb Wave 크랙검사)

  • 문병준;김노유
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2002.06a
    • /
    • pp.227-233
    • /
    • 2002
  • Suspension system is one of the most important components indespensible for stability and reliability of automobiles. The demands to more safe and durable suspension system have been increased as the automobiles get popular and improve in quality. The crack in the coil spring of the suspension system produced during manufacturing may grow under a fatigue load and cause a severe safety problems which lead to a catastrophic damage to the passengers. Many conventional NDT techniques including ET, RT, and UT are less sensitive or hard to apply to detect the surface breaking crack in the suspension coils partly because the techniques are point-to-point measurement methods, thus take too long time to inspect the coil spring longer than 1m. Contrary to this, Lamb wave technique is full-field measurement method that make it possible to examine the whole coil spring in real time. In this paper, the Lamb wave is applied to the coil spring to investigate the possibility to detect the cracks on the surface of the coil spring.

  • PDF

A Basic Research on Estimation of Material Condition by Using Stress Dependency of Sound Speed (음속의 응력의존성을 이용한 재료 상태평가에 대한 기초적 연구)

  • Kim, K.J.;Jhang, K.Y.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.4
    • /
    • pp.53-60
    • /
    • 1996
  • In the conventional linear elasticity, sound speed is determined by only elastic modulus and density of the medium. In actual, however, sound speed depends on the stress and this dependency becomes nonlinear as the stress increases. These phenomena can be introducing nonlinear elastic modulus. In this paper, relationships between nonlinear elastic modulus up to 4th order and the internal status of materials are discussed through computer simulations and experiments. For the measurement of sound speed, a new type of measurement system using ultrasonic wave is proposed on the basis of ultrasonic pulse echo method which has been generally used in nondestructive ultrasonic test equipment. In order to confirm the stress dependency of sound speed, several experiments are carried out for alumina specimen.

  • PDF

Development of wall-thinning evaluation procedure for nuclear power plant piping - Part 2: Local wall-thinning estimation method

  • Yun, Hun;Moon, Seung-Jae;Oh, Young-Jin
    • Nuclear Engineering and Technology
    • /
    • v.52 no.9
    • /
    • pp.2119-2129
    • /
    • 2020
  • Flow-accelerated corrosion (FAC), liquid droplet impingement erosion (LDIE), cavitation and flashing can cause continuous wall-thinning in nuclear secondary pipes. In order to prevent pipe rupture events resulting from the wall-thinning, most NPPs (nuclear power plants) implement their management programs, which include periodic thickness inspection using UT (ultrasonic test). Meanwhile, it is well known in field experiences that the thickness measurement errors (or deviations) are often comparable with the amount of thickness reduction. Because of these errors, it is difficult to estimate wall-thinning exactly whether the significant thinning has occurred in the inspected components or not. In the previous study, the authors presented an approximate estimation procedure as the first step for thickness measurement deviations at each inspected component and the statistical & quantitative characteristics of the measurement deviations using plant experience data. In this study, statistical significance was quantified for the current methods used for wall-thinning determination. Also, the authors proposed new estimation procedures for determining local wall-thinning to overcome the weakness of the current methods, in which the proposed procedure is based on analysis of variance (ANOVA) method using subgrouping of measured thinning values at all measurement grids. The new procedures were also quantified for their statistical significance. As the results, it is confirmed that the new methods have better estimation confidence than the methods having used until now.

Measurement of Reverberation Times in the Compartment of Vehicles Using Wavelet Filter Bank (웨이블렛 필터를 이용한 자동차 실내공간의 잔향시간 측정에 관한 연구)

  • 이상권;유동준;이승영;박동철
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.2
    • /
    • pp.111-118
    • /
    • 2004
  • A number of researchers have attempted to measure the reverberation time of a passenger car, ut the reverberation time of passenger car is too short to measure with the traditional band pass filter. And if the reverberation time is very short, the product of the reverberation time (T) and the bandwidth (B) of the traditional band pass fitter becomes small. The low limit of BT product required for the measurement of reverberation time with the traditional band pass filter is 16. In order to overcome this problem, the wavelet filter bank was developed. In this study, this new wavelet filter was employed to measure the reverberation times of five different classes of passenger cars. The low limit of BT product required for the measurement of reverberation time with the wavelet filter is 4. The reverberation times of five passenger cars were measured successfully with the new wavelet filter bank. The reverberation times measured in most passenger cars was found to be around 0.04. Compared with general acoustic rooms like concert halls, this is a very short reverberation time

Effects of Combined Postural Correction Exercises on Selected Muscle Activity and Stiffness in Children With Cerebral Spastic Diplegia: Case Study (융합적 자세교정치료가 뇌성경직양측마비 아동의 선택된 근육 활성도와 강직도에 미치는 영향: 사례연구)

  • Shim, Jae-Hun;Kang, Min-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.2
    • /
    • pp.91-99
    • /
    • 2018
  • The aim of this study was to investigate the short-term effects of combined postural correction exercises (CPCE) on muscle stiffness and muscle activity in children with cerebral spastic diplegia(CSD). The subjects were 3 children (2 male and 1 female) with CSD from 4 to 7 years old. The measurement sites were upper trapezius muscle(UT), rectus abdominis muscle(RA), and gluteus maximus muscle(Gmax), muscle stiffness and muscle activity were measured using Myoton and surface EMG, and the symmetry of both sides was also examined. As a result, children with severe compensatory action showed decreased muscle stiffness and muscle activity in UT and RA and increase in Gmax after CPCE intervention. Especially, the left and right symmetry of the muscles was decreased. In this study, despite some limitations, CPCE have shown a positive effect in posture correction of children with CSD.

A Study on the Measurement of the Internal Crack in Flange Welding Zone by Digital Shearography (전자전단 간섭법을 이용한 플랜지 용접부 내부 결함 측정에 관한 연구)

  • Kim, Jeong-Pil;Kang, Young-June;Park, Sang-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.1
    • /
    • pp.97-104
    • /
    • 2009
  • There is a many kinds with nondestructive testing such as RT and UT representatively. Referred before two testing methods there is a limit which is spatial such as nuclear pipe, small vessel, sealing up vessel. So a new technique needs to overcome the limit which is spatial. shearography will be able to overcome the limit which is spatial. This paper introducing shearography which was known as non-contact full-field testing method and It is an interferometric technique for measurement of surface deformation such as displacement or displacement gradient. Also, a research about internal defect of the flange welding zone was accomplished. About variation with method pressurized with the Gaseous Nitrogen. Phase map where is various were measured according to changing a sheared direction, size of crack and loaded pressure. Consequently, crack quantitatively to be detected qualitatively was measured by using shearography.

Application of Geometry-Efficiency Variation Technique to Activity Measurement of $^{204}T1$ for 3-PM Liquid Scintillation Counting

  • Lee Hwa Yong;Seo Ji Suk;Kwak Ji Yeon;Hwang Han-Yull;Lee K. B.;Lee Jong Man;Park Tae Soon
    • Nuclear Engineering and Technology
    • /
    • v.36 no.2
    • /
    • pp.121-126
    • /
    • 2004
  • 3-PM liquid scintillation counting using the geometry-efficiency variation technique has been applied to the activity measurement of $^{204}T1$, which decays to $^{204}Hg\;and\;^{204}Pb\;by\;{\beta}^-$ and E.C., respectively. The TDCR values K have been derived over a wide range, 0.78 < K < 0.97, by displacing the detectors up to 50 mm away from an unquenched liquid scintillation sample $^{204}Tl$. The derived plots of the logic sums of double coincidences $N_D(K)$ very K vary linearly in the observed regions. The fractions of losses due to electron capture decay have been taken into account by employing a PENELOPE Monte Carlo simulation. The calibrated activity is 102.3 kBq at a reference date of July 1st, 2002 (UT) with a combined uncertainty of $0.63\%$. This is consistent with the value determined by means of the CIEMAT/NIST method at KRISS.