• Title/Summary/Keyword: UT

Search Result 479, Processing Time 0.023 seconds

Global Collaboration of R&D: A Case of Samsung Electro-Mechanics and UT Dallas (글로벌 R&D협력: Samsung Electro-Mechanics와 UT Dallas대학 사례연구)

  • Suh, Sang-Hyuk;Lee, Sun-Young
    • Journal of Korea Technology Innovation Society
    • /
    • v.17 no.1
    • /
    • pp.174-194
    • /
    • 2014
  • Collaborative technology development is now one of the most significant modes of activity in the global scientific community. However, the international cooperation of science and technology simultaneously provides opportunities and challenges, and the results of global R&D collaboration can be positive or negative as the cooperation conditions of the parties may be different according to the types or characteristics of the participants and the pattern, purpose, and motivation of cooperation. In order to minimize the risk and improve the performance of cooperation, more comprehensive as well as micro-level research is needed. This study investigates a case of successful collaborative R&D conducted by several firms, universities, and public research organizations in both Korea and the U.S.A. The aim of this study is to identify the factors of successful R&D collaboration.

Report of the Oblique Ionospheric Sounding Results from Korea to Japan

  • Bae, Seok-Hee;Park, Chung-Rim;Wee, Kyu-Jin;Akira Ohtani;Mikitoshi Nagayama;Kiyoshi Igarashi
    • International Union of Geodesy and Geophysics Korean Journal of Geophysical Research
    • /
    • v.22 no.1
    • /
    • pp.1.2-5
    • /
    • 1994
  • Ionospheric sounding experiments have been conducted at RRL (Radio Research Laboratory), Ministry of Communications, using Digisonde 256 since its installation in 1990. Routine observations of the vertical sounding are carried out 48 times (or 39 times) a day, at every 24 hour. In addition, we also made oblique sounding experiments to obtain the real time data of Maximum Usable Frequency (MUF) and detect the anomalous HF propagation, as a part of the joint study between RRL and CRL (Communications Research Laboratory) of Japan. The two stations involved in the study were Anyang (RRL, Korea) and Kokubunji (CRL, Japan). The ionosondes used in both stations were Digisonde 256, developed by ULCAR (University of Lowell, Center for Atmospheric Research), U. S. A. , and the synchronization of time was accomplished with the help of GPS receiver. During most part of the experiments RRL transmitted non-modulated pulses, and CRL received them. The experiment was scheduled from October 25 through October 29, 1993. However, the ionosphere was not developed well enough to conduct the experiment with pre-set operation parameters. The experiment became successful (from 0500 UT to 0800 UT, October 29) only after the operation parameters had been changed, and the continuous ionograms were obtained by CRL at 0718 UT and 0733 UT in October 29, 1993. We believe this type of experiment will ensure the qualitative enhancement of solar-terrestrial physics research and a routine observation of the oblique ionospheric sounding. In this report, we present the results of the fore-mentioned oblique sounding as well as the vertical sounding results obtained by Digisonde 256 at Anyang station of RRL.

  • PDF

Effect of Craniocervical Flexion on Muscle Activities of Scapula Upward Rotator Muscle During Push-Up Plus Exercise in Subject With Winging of Scapula

  • Song, Si-Jeong;Lim, One-Bin;Kim, Jeong-Ah;Yong, Joon-Hyoung;Cynn, Heon-Seock;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.21 no.2
    • /
    • pp.48-56
    • /
    • 2014
  • The aim of this study to investigate the effects of craniocervical flexion on muscle activities of scapular upward rotators during push-up plus exercise in subjects with winging scapula. Eighteen males with scapular winging were recruited, and each subject performed knee push-up plus and other exercises, in two conditions (craniocervical flexion vs. natural head positions). A surface electromyography (EMG) was used to measure upper trapezius (UT), serratus anterior (SA), and lower trapezius (LT) muscle activity. A paired t-test was used to determine the statistical significance between the different condition with/without applying of craniocervical flexion. UT EMG activity significantly decreased and SA EMG activity significantly increased during knee push-up plus involving the craniocervical flexion compared to the natural head position. However, no significant differences (p>.05) were found in the activity of the LT muscle. The UT/SA ratios with and without craniocervical flexion showed a significant difference (p<.05). These results showed that the knee push-up plus other exercises performed with craniocervical flexion could strengthen the serratus anterior muscle and minimize the activity of the UT muscle.

Comparative Analysis of the Serratus Anterior Muscle Activity When Right and Left Knee Lift during Quadruped Position on Push Up Plus

  • Nam, KiSeok;Kim, JiWoong;Park, JiWon
    • The Journal of Korean Physical Therapy
    • /
    • v.32 no.1
    • /
    • pp.58-63
    • /
    • 2020
  • Purpose: This study examined the effects of the right or left knee lift during push up plus in the quadruped position on the serratus anterior (SA) muscle activity. Methods: Twenty-one subjects (male 11, female 10) performed the quadruped position on push up plus. The muscle activities of the lower trapezius (LT), SA, and upper trapezius (UT) were measured by surface electromyography. Repeated measurements of one-way ANOVA were performed for statistical analysis of the data, and the criterion for statistical significance was set to p<0.05 and comparative analysis of the UT and SA ratio using a Paired t-test. Results: The right SA increased the muscle activity of the right knee lift during quadruped position push up plus (p<0.05). In particular, the right SA muscle activity was higher than the left. In addition, comparative analysis of the UT and SA ratio to the right knee lift during quadruped position push up plus was performed (p<0.05). The right was found to be a significant statistic compared to the left, but the left SA increased the muscle activity of the left knee lift during quadruped position push up plus (p<0.05). The left SA muscle activity was higher than right. In addition, comparative analysis of UT and SA ratio to the left knee lift during quadruped position push up plus was performed (p<0.05). The left was found to be a significance statistic than the right. In addition, the interaction effect between the groups showed significant differences (p<0.05). Conclusion: Knee lift during push up plus is recommended for the selective activation of a research exercise protocol of one side of the serratus anterior.

A Small Crack Length Evaluation Technique by Electronic Scanning (전자적 스캔에 의한 미소결함길이 평가기법)

  • Cho, Yong-Sang;Kim, Jae-Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.1
    • /
    • pp.15-20
    • /
    • 2009
  • The results of crack evaluation by conventional UT(Ultrasonic Test)is highly depend on the inspector's experience or knowledge of ultrasound. Phased array UT system and its application methods for small crack length evaluation will be a good alternative method which overcome present UT weakness. This study was aimed at checking the accuracy of crack length evaluation method by electronic scanning and discuss about characteristics of electronic scanning for crack length evaluation. Especially ultrasonic phased array with electronic scan technique was used in carrying out both sizing and detect ability of crack as its length changes. The response of ultrasonic phased array was analyzed to obtain the special method of determining crack length without moving the transducer and detect-ability of crack minimal length and depth from the material. A method of crack length determining by electronic scanning for the small crack is very real method which has it's accuracy and verify the effectiveness of method compared to a conventional crack length determination.

A Study on Arterial Characterization by using Up-stroke Time of Photoplethysmogram (용적맥파 상승시간에 의한 혈관 특성화 연구)

  • Byeon, M.K.;Han, S.W.;Huh, W.
    • Journal of IKEEE
    • /
    • v.11 no.3
    • /
    • pp.108-116
    • /
    • 2007
  • This paper proposed an analyzable parameter and its analytic method to provide more accurate information than currently employed 4 channels system which uses pulse wave velocity (PWV) information of the volume pulse wave measured from 4 arterial channels for the characterization of arterial vessel. In order to verify the volume pulse waves on 4 sites were simultaneously acquired subjects aged from 12 to 81 years old. and the proposed parameters were extracted from time (UT) was then compared with blood pressure. Then, the regression analyses were done relationships among the proposed parameter and others, such as aging, pulse transit time pressure (BP). The followings are the results of linear regression analysis of the proposed parameter for total 50 normal subjects. We selected any two subjects (58 years and 27 years) and measured PPG (photoplethysmogram) and BP of before and after exercise. The coefficient of correlations between BP and UT observed was -0.928 for 50 years subject, and -0.922 for 20 years subject. For total 50 normal subjects, in case of correlation between the pulse transit time and BP, the result showed -0.170 on left side and -0.233 on right side, and the coefficient value of correlation between the pulse transit time and UT was -0.607 on left side and -0.510 on right side. UI is strongly correlated with the pulse transit time than BP. Hence, we believe that the proposed parameter is related with the index of arterial stiffness.

  • PDF

The comparison of muscle activity according to various conditions during smartphone use in healthy adults

  • Kim, You Lim;Yoo, Jaehyun;Kang, Sinwoo;Kim, Taerim;Kim, Namyeol;Hong, Sojeong;Hwang, Wonjeong;Lee, Suk Min
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.1
    • /
    • pp.15-21
    • /
    • 2016
  • Objective: The purpose of this study was to see the changes in muscle activity of the upper limb in persons using a smartphone. Design: Cross-sectional study. Methods: An experiment was conducted to target 15 right-handed university students. Experiments were carried out for students using cell phones for more than a year. In this study, experiments were carried out with one-handed and both handed operation of smartphone use in a sitting position, the same parameters with smartphone use in a standing position. The experiments were carried out by having the subjects write a text message in Korean on the smartphone for 3 minutes repeated 3 times with a rest period of 10 seconds given between each 3 minute period. Electromyography (EMG) was used to record the muscle activity of the upper trapezius (UT), extensor carpi radialis (ECR), and abductor pollicis (AP) during phone operation. Results: The muscle activity of the AP and ECR were significantly higher during single handed compared to double handed in both sitting and standing position (p<0.05). The muscle activity of the ECR was significantly higher in standing position compared to sitting position with double handed use of the smartphone (p<0.05). UT muscle activity of the right has been activated more than twice compared to the left UT in a sitting position (p<0.05). And UT muscle activity on the right has been activated more than five times compared to the left in a standing position (p<0.05). Conclusions: Using smartphone with double hand is useful for the prevention of musculoskeletal disorders.

Measurement of Longitudinal and Transverse Wave Speed in Solid Materials Using Immersion Ultrasonic Testing (수침 초음파 시험법을 이용한 고체의 종파와 횡파 속도의 측정)

  • Shin, Yo-Sub;Yoon, Yeo-Ho;Kim, Young-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.1
    • /
    • pp.40-45
    • /
    • 2008
  • Immersion ultrasonic testing (UT) was used to determine elastic moduli of solid materials instead of the widely-used contact UT method. Conventionally, immersion UT is only used for determining the longitudinal wave speed. However, in this research, transverse wave speed was measured through finding transverse wave echoes caused by mode-conversion at material's boundary. Also, even in the cases when wave speeds could not be determined due to unknown thickness, Poisson's ratio was able to be calculated from the ratio of longitudinal and transverse wave speeds. This technique was verified for several materials, and it was found that higher accuracy was obtained by immersion UT method for materials either with relatively high wave speed or with relatively small Poisson's ratio. This technique thus will be suitable fur ceramics or high strength materials.

Effects of Smartphone Use on Muscle Fatigue and Pain and, Cervical Range of Motion Among Subjects With and Without Neck Muscle Pain (목 주위 근육 통증 여부에 따른 스마트폰 사용이 근 피로도와 통증, 목뼈운동범위에 미치는 영향)

  • So, Yoon-Jie;Woo, Young-Keun
    • Physical Therapy Korea
    • /
    • v.21 no.3
    • /
    • pp.28-37
    • /
    • 2014
  • The purpose of this study was to investigate the effects of smartphone use on muscle fatigue and tenderness in the cervical erector spinae (CES) and the upper trapezius (UT) and on the cervical range of motion among subjects with and without neck muscle pain. The subjects were 30 smartphone users in their 20 s who -were assigned to either an experimental group with neck muscle pain or a control group without neck muscle pain. Muscle fatigue and tenderness in the CES and the UT as well as the subjects' cervical range of motion were measured before and after 20-min smartphone sessions in a sitting position. In a between-group comparison of muscle fatigue, the experimental group showed a significantly greater decrease in median frequency in the CES and the right UT after smartphone use (p<.05). Regarding the assessment of muscle tenderness after smartphone use, the experimental group showed a statistically significant decrease in the pressure-pain threshold (PPT) in all muscles (p<.05), whereas the control group showed a significantly decreased PPT in the right CES and the UT (p<.05). The assessment of the cervical range of motion revealed a statistically significant reduction in the cervical flexion-extension and left lateral flexion in the experimental group (p<.05) after smartphone use. However, there was no significant change in the cervical range of motion in the control group (p>.05) after smartphone use. When compared with the control group, the experimental group demonstrated greater changes in cervical extension, lateral flexion, and rotation, except for cervical flexion (p<.05). In conclusion, when smartphone users have pre-existing neck muscle pain, the use of a smartphone further increased muscle fatigue and tenderness in the neck and reduced PPT and the cervical range of motion.

The γ-Benzenehexachloride Degradation Using Transgenic Tobacco Plant (담배 형질전환 식물체를 이용한 γ-Benzenehexachloride의 분해)

  • Lee, Jeong-Kyung;Park, Soon-Ki;Chung, Il-Kyung
    • Journal of Plant Biotechnology
    • /
    • v.30 no.1
    • /
    • pp.103-108
    • /
    • 2003
  • LinA gene involving in the ${\gamma}$-benzenehexachloride degradation have been cloned from Sphingmonas paucimobilis UT26. This linA gene which catalyzes the first dechlorination step of ${\gamma}$-benzenehexachloride is known to play a key role in the ${\gamma}$-benzenehexachloride degradation pathway in UT26. In this study, the linA gene was designed to clean-up the ${\gamma}$-benzenehexachloride and its derivatives contaminated in soil, water and air using transgenic tobacco plants. The linA transgene was introduced into the chromosome of tobacco using leaf-disk transformation approach as revealed by Southern blot analysis. In addition, mRNA and protein produced by linA gene was expressed at a high level in the leaf tissue as demonstrated by both northern blot analysis and Western bolt analysis with polyclonal antibody against S. paucimobilis UT26. in vitro analysis using GC-MS showed that transgenic tobacco plant produced the linA protein which effectively degraded ${\gamma}$-benzenehexachloride into ${\gamma}$- pentachlorocyclohexene and 1,2,4-trichlobenzene compounds which are less toxic.