지중배전케이블 기저수지의 수증기 투과 전달특성 (Chararcteristics of Water Vapor Transmission in Base Resin for Underground Residential Distribution Power Cable)

  • 송재주;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 기술교육전문연구회
    • /
    • pp.149-153
    • /
    • 2003
  • In URD(Underground Residential Distribution) power cable, experiments of WVT(Water Vapor Transmission) test on the Base Resin accomplished to specimens which contained CB(Carbon Black), anti-oxidant to base resin and made by pressing to resin of pellet or lump form. a kind of specimens was HDPE(High Density Polyethylene), MDPE(Medium Density Polyethylene), LDPE(Low Density Polyethylene), LLDPE(Linear Low Density Polyethylene), PVC(Polyvinyl Chloride). as a results of WVT test, we saw that WVT ratio was HDPE < LLDPE < MDPE≒LDPE${\ll}$ PVC. WVT properties of PVC using for jacket showed properties 15-20 times more than MDPE or LLDPE. Therefore, to development of watertightness cable, our works present need of Changing in insulating materials.

  • PDF

지중 배전케이블용 자켓 컴파운드의 특성평가 (Evaluation of Jacket Compounds for Underground Distribution Power Cables)

  • 한재홍;송일근;김동명;이재봉;정창수
    • 한국전기전자재료학회논문지
    • /
    • 제15권8호
    • /
    • pp.687-694
    • /
    • 2002
  • In order to replace the jacket material for URD power cables, the 6 kinds of polyethylene compounds were manufactured and evaluated. The characteristics of the compounds were investigated by water vapor transmission (WVT) test, thermal and mechanical test. In WVT test, all the polyethylene compounds showed the superior water resistance to conventional PVC. The molecular structure and density of polyethylene play an important role in WVT. Also, the polyethylene compounds showed the suitable characteristics in thermal and mechanical test. Especially, the linear polyethylene compounds showed the superior characteristics to LDPE ones. Due to the fillers in compounds, the abrasion resistance was decreased and the cut-through resistance was increased. From this study, it can be considered that the polyethylene compounds may be suitable to jacket material for URD power cables.

FMEA에 근거한 LV URD 케이블의 고장분석 (Failure Analysis of LV URD Cable based on FMEA)

  • 송길목;한운기;김영석;김선구;곽희로
    • 조명전기설비학회논문지
    • /
    • 제21권5호
    • /
    • pp.90-98
    • /
    • 2007
  • 본 연구의 목적은 고장 케이블(LV URD(low voltage underground) cable)의 원인을 밝히는데 있다. 분석방법은 외형패턴, 열패턴, 표면구조 분석, 열분석, 성분분포 등 다양한 분석기기를 이용하여 분석되었다. 국제기준과 사고케이블 제작회사가 제시하고 있는 규정이 일치하는지의 여부를 분석하였으며, 국내산 케이블과의 비교분석하였다. 그 내용을 요약하면 다음과 같다. (1) 사고케이블 자체의 절연성능을 저하시키는 요인으로 IEC 60502-1과 IEC 60811-1-1에 의한 절연피복의 최소 두께가 시방(specification)과 일치하지 알음을 확인하였다. (2) 적외선분광기에 의해 적외선흡광피크가 동일 재료에서 일치하지 않는 것으로 나타났다. (3) PVC bedding 부분이 열적으로 취약하여 장시간 현장에 노출되어 사용되는 경우 이와 유사한 패턴의 사고를 유발할 것으로 판단된다.

자켓 컴팍운드용 절연재의 수증기투과 및 절연파괴 특성 (Characterization of Water Vapor Transmission & Dielectric Breakdown in Insulation Materials for Jacket Compound)

  • 송재주;한재홍;송일근;한용희;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.52-56
    • /
    • 2001
  • Experiments of 2 type on insulating compounds accomplished to change PVC using in URD(Underground) power cable jacketing. one was DB(Dielectric Breakdown) test on the pure base resins and the others were WVT(Water Vapor Transmission) test on the compounds which contained C/B(Carbon Black), anti-oxidant to base resin. a kind of specimens made by pressing to resin of pellet or lump form was HDPE(High Density Polyethylene), MDPE(Medium Density Polyehylene), LDPE(Low Density Polyethylene), LLDPE(Linear Low Density Polyethylene), PVC(Polyvinyl Chloride). As a results of AC DB and WVT test, we saw that strength of Insulation was HDPE> LLDPE = MDP E> LDPE and WVT ratio was HDPE

  • PDF

전력케이블 열화진단기법의 현장적용 (Field Application of Power Cable Diagnosis System)

  • 김주용;한재홍;송일근;김상준;이재봉;오재형
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.148-151
    • /
    • 2002
  • In order to prevent the failures of underground distribution power cables we need to measure insulation condition in the field. Until now we used DC high voltage as a power source for the cable diagnosis but it was not proper method to the XLPE insulation cables because DC high voltage can affect sound insulation and can't diagnose exactly insulation degradation. For these reasons we imported isothermal relaxation current measurement system called by KDA-1 from germany but it's reliability did not proved in our URD cables. DC voltage decay measurement system was developed by domestic company but they don't have field experience. In this paper we tried to prove reliability of these two systems in the field. Through the field diagnosis and Ac breakdown test the two systems showed similar results.

  • PDF

파괴수명예측을 통한 지중배전용 전력케이블의 열화 진단 (Aging Diagnosis of Underground Distribution Power Cables Using Breakdown Lifetime Prediction)

  • 김충배;이정빈;임장섭;장영학;이진;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.222-225
    • /
    • 1999
  • Degradation diagnosis of XLPE insulated URD cables was accomplished through out new method. which was to be analyzed non-electrical experiments and synthesized by degradation points. To supplement this method, it was also carried out using several electrical analyses. Breakdown voltages were measured and breakdown lifetimes were Predicted appling for Weibull distribution function. As a result, breakdown lifetime in failure cables was shorted up to 1/3 times than that in general cables. It was very available to estimate cable degradation using above method, but it needs further study on XLPE insulated URD cables in order to improve reliability.

  • PDF

새로운 지중배전케이블용 절연재료의 공간전하 거동 (Space Charge Behaviors of New Insulating Materials for URD cables)

  • 고정우;서광석;김종은;남윤선;김덕주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 추계학술대회 논문집
    • /
    • pp.207-210
    • /
    • 1998
  • Electrical properties such as space charge distribution and electrical conduction of XLPE/VLDPE blends were studied. When the VLDPE is blended, residual charge inside XLPE increases. In case of electrical conduction characteristics, there were no changes in electrical conduction mechanism, space charge limited conduction. XLPE/VLDPE blend including crosslinking coagent showed relatively small current density. It might be due to the carbonyl group in crosslinking coagent.

  • PDF

자켓 컴파운드용 절연재의 수증기투과 및 절연파괴 특성 (Characterization of Water Vapor Transmission & Dielectric Breakdown in Insulation Materials for Jacket Compound)

  • 송재주;한재홍;송일근;한용희;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.52-56
    • /
    • 2001
  • Experiments of 2 type on insulating compounds accomplished to change PVC using in URD(Underground) power cable jacketing. one was DB (Dielectric Breakdown) test on the pure base resins and the others were WVT(Water Vapor Transmission) test on the compounds which contained C/B(Carbon Black), anti-oxidant to base resin. a kind of specimens made by pressing to resin of pellet or lump form was HDPE(High Density Polyethylene), MDPE(Medium Density Polyehylene), LDPE(Low Density Polyethylene), LLDPE(Linear Low Density Polyethylene), PVC (Polyvinyl Chloride). As a results of AC DB and WVT test, we saw that strength of Insulation was HDPE > LLDPE ≒ MDPE > LDPE and WVT ratio was HDPE < LLDPE < MDPE < LLDPE ≒ LDPE${\ll}$PVC. WVT of PVC using for jacket showed characteristic 15 times more than MDPE or LLDPE. Therefore, to development of watertightness cable, our works present need of Changing in insulating materials

  • PDF

22.9[kV] 지중배전용 전력케이블의 전기적 특성과 파괴수명 고찰 (The Consideration of Electrical Characteristics and Breakdown Lifetime in 22.9[kV] Underground Distribution Power Cables)

  • 김충배;홍경진;임장섭;정우성;김상준;김태성
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권9호
    • /
    • pp.628-633
    • /
    • 1999
  • Degradation diagnosis of XLPE insulated URD cables was accomplished through out new method, which was to be analyzed by non-electrical experiments and synthesized by degradation points. To supplement this method, It was also carried out using several electrical analyses. Tan$\delta$ had commonly a different tendency by means oftemperature and frequency and also appeared higher at the outer part rather than innerpart of insulator. PD-q increased generally in proportion to the applied voltage andshowed regular patterns in relation to the thickness of insulator. Breakdown voltageswere measured and breakdown lifetimes were predicted appling for Weibull distribution function. As a result, breakdown lifetime in failure cables was shorter up to$\fraction one-third$ times than that in general cables. It was very available to estimate cable degradation using above method, but it needs further study on XLPE insulated URD cables in order to improve reliability.

  • PDF

지중배전케이블의 서어지 전파특성 실증연구 (A Study on the Surge Propagation Property of Underground Distribution Cables by Field Tests)

  • 이재봉;김병숙;박철배;정연하;한병성
    • 조명전기설비학회논문지
    • /
    • 제21권10호
    • /
    • pp.118-125
    • /
    • 2007
  • 가공선로와 지중선로가 혼합된 배전계통에서 뇌서어지와 개폐서어지가 입상주를 통하여 유입될 수 있다. 이러한 서어지는 케이블을 따라서 이동하게 되고 케이블의 종단에서 반사된다. 이때 반사되는 서어지는 그 크기가 2배 정도가 되고 지중배전선로의 절연을 위협할 수 있다. 한전의 지중배전계통을 모의할 수 있는 모델계통을 만들고 이 계통에 서어지를 인가하여 케이블의 서어지 전파 특성을 측정하였다. 실제시험으로 측정한 결과를 EMTP 해석 결과와 비교하여 EMTP 파라미터들을 수정하였다. EMTP 해석에서 케이블 절연체의 유전율, 피뢰기의 특성곡선, 서어지의 파형을 조정하면 실증시험 결과와 거의 일치하는 결과를 얻을 수 있었으며, 케이블의 말단에서 2배 정도 전압상승이 되고 분기에 의하여 복잡하게 전파되는 것을 확인하였다.