• Title/Summary/Keyword: UHF method

Search Result 176, Processing Time 0.022 seconds

A Design of UHF-Sensor for Diagnosis of Insulator (절연진단용 UHF 센서 모델 설계)

  • Choi, Eun-Hyuck;Do, Yeong-Heoi;Kim, Gi-Chai;Kim, Lee-Kook;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.115-117
    • /
    • 2005
  • If obstacle in GIS(Gas Insulted Switchgear), its affects are great are on the community and it is consequently demanded lots of difficulities to recover and repair. Accordingly, diagnosis techniques, that are able to prevent from accidents before they happen by providing more stable and highly reliable power effectively and finding sign of the accidents is very important. A novel UHF(Ultra High Frequency)-microstrip antenna is presented. The measured impedance bandwidth of the proposed antenna is from 0.5[GHz] to 15[GHz] with the stop band from 0.5[GHz] to 10.7[GHz] for VSWR<2. Form results of this study, The antenna is will play an important role for the sensor for insulation diagnosis system by UHF method of real site GIS and power equipment using $SF_6$ gas.

  • PDF

A Study on the UHF PD Sensor and Novel Pattern Analysis Technology for Diagnosis of the High Power Apparatus (초고압 전력기기 진단을 위한 UHF PD 센서 및 패턴분석 기술에 관한 연구)

  • 강원종;이창준;강윤식;이희철;박종화
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.2
    • /
    • pp.83-90
    • /
    • 2004
  • This paper describes investigations of the UHF(Ultra High Frequency) PD(Partial Discharge) measuring technology designed for monitoring of PD in high power apparatus. Based on the spiral antenna theory, the hole type sensor for GIS with metal flange spacer and injection type sensor for oil filled transformer are developed. The experimental results show measurement characteristics of the PD sensor for several artificial defects in gas-insulated system(GIS) and oil transformer. Moreover, we proposed the new $\phi$-f-q method for the purpose of condition assessment of high power apparatus.

Design and Analysis of a NMOS Gate Cross-connected Current-mirror Type Bridge Rectifier for UHF RFID Applications (UHF RFID 응용을 위한 NMOS 게이트 교차연결 전류미러형 브리지 정류기의 설계 및 해석)

  • Park, Kwang-Min
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.6
    • /
    • pp.10-15
    • /
    • 2008
  • In this paper, a new NMOS gate cross-connected current-mirror type bridge rectifier for UHF RFID applications is presented. The DC converting characteristics of the proposed rectifier are analyzed with the high frequency equivalent circuit and the gate capacitance reduction technique for reducing the gate leakage current due to the increasing of operating frequency is also proposed theoretically by circuitry method. As the results, the proposed rectifier shows nearly same DC output voltages as the existing NMOS gate cross-connected rectifier, but it shows the gate leakage current reduced to less than 1/4 and the power consumption reduced more than 30% at the load resistor, and it shows more stable DC supply voltages for the valiance of load resistance. In addition, the proposed rectifier shows high enough and well-rectified DC voltages for the frequency range of 13.56MHz HF(for ISO 18000-3), 915MHz UHF(for ISO 18000-6), and 2.45 GHz microwave(for ISO 18000-4). Therefore, the proposed rectifier can be used as a general purpose one to drive RFID transponder chips on various RFID systems which use specified frequencies.

Development Portable Pipe Spool Location-Confirm System Based UHF RFID (UHF RFID기반 이동형 파이프 스풀 위치 인식 시스템 개발)

  • Kim, Jinsuk;Shin, Yongtae
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.3 no.10
    • /
    • pp.329-336
    • /
    • 2014
  • Pipe spool is the most important element of plant equipment in plant construction site. Currently, the plant construction site manage the pipe spool location and usage history by handwriting. Frequently, the pipe spool is moved to unpredictable places by field workers in many construction sites and in cases like this, the pipe stool is replaced with another similar pipe spool. Since it's hard to determine the exact location of some of the pipe spools, it takes unnecessary time and labour to find the missing pipe spools, which proves that stock management is not under control. The purpose of our system is to make the identification of real-time location of the field pipes possible by attaching UHF RFID tags to the pipe spool, which will be used to connect with UHF RFID reader and antenna on vehicles. A field test conducted by the proposed system resulted in the success rate of 98% and the missing 2% was recuperated by hands-on correction, which proved that stock management through the proposed method can be 100% effective. The proposed system is expected to reduce labour costs and make stock control of assets possible, as well as applicable to similar stock management environments.

UHF Band RFID Tag Antenna Mountable on metallic Object (금속에 부착 가능한 UHF 대역 RFID 태그 안테나)

  • Jung Jun-Mo;Yu Byung-Gil;Jung Byung-Woon;Lee Byung-Je
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.5 no.1 s.9
    • /
    • pp.65-70
    • /
    • 2006
  • A UHF band RFID passive tag antenna, which can be attached on metallic objects, is proposed. The proposed tag antenna is more insensitive to the size of the metallic object than conventional PIFAs or IFAs. It is constructed on a multi-layer and its size is reduced by using a 'L' slit. Performances of the antenna is analyzed by Ansoft's HFSS and measured using a back-scattering method. The simulated and measured data are obtained with varying the size of metallic object.

  • PDF

Design of Directional Coupler for TX/RX Isolation in UHF Band RFID Application (UHF 대역 RFID를 위한 송수신 분리 방향성 결합기 설계)

  • Na, Won;Kim, Wan-Kyu;Yu, Jong-Won;Lee, Moon-Que
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.2
    • /
    • pp.43-49
    • /
    • 2008
  • In this paper, new directional couplers for T/R switch of UHF RFID applications are proposed to overcome TX-to-RX leakage problem. The proposed method can remove TX-to-RX leakage caused by both imperfect isolation characteristic of the conventional directional coupler and the mismatch of antenna impedance. Two directional couplers are implemented using distributed elements and lumped elements respectively for the verification. The varactor tuneable circuits for compensation of the antenna mismatch is also proposed. The measurement result shows excellent TX-to-RX leakage suppression, more than 45dB in 910MHz.

  • PDF

Development and characterization of a ultra-wide bandwidth video detector for the UHF partial discharge monitoring system (UHF 부분방전 감시 장치를 위한 초광대역 검출장치 개발 및 특성조사)

  • Park, Ki-Jun;Goo, Sun-Geun;Yoon, Jin-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1649-1651
    • /
    • 2002
  • Ultra-wide bandwidth (UWB) detection method has been widely used as a front end detection scheme for the ultra-high frequency (UHF) partial discharge (PD) monitoring systems. A broad-band video detector module was developed and characterized for the UHF UWB PD detection systems. The useable bandwidth of the module is more than 2 GHz and it is optimized for 50-ohm systems. The detection sensitivity and dynamic range of the module were characterized by using a known ns-width RF pulses of GHz range. The dynamic range is more than 6-decades and the module can detect pulsed RF signals down to 1 nW. The detector module can eliminate expensive equipment such as high speed oscilloscopes and radio frequency (RF) spectrum analyzers. Therefore, it enables one to use slow speed data acquisition systems for the PD monitoring at the UHF range. The detector module was used to detect real PDs of about <3 pC. The module converts the UWB PD signals into a low-bandwidth video signal with a high signal-to-noise ratio.

  • PDF

Study on the UHF-band Variable Attenuator Using the 3-dB Coupler (UHF대역 3-dB 커플러(Coupler)를 이용한 가변 감쇄기(Attenuator)에 대한 연구)

  • 박경태
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.2 no.2
    • /
    • pp.68-74
    • /
    • 2001
  • A design and implementation method for the UHF-band(800MHz) variable attenuator using the 3dB coupler is proposed. The 90 degree, 3-dB Coupler is used for the variable attenuator. The principal theory for the 3-dB coupler is introduced. The 3-dB Coupler is designed by the mathematical analysis and a computer simulation tool. A PIN diode is used for the variable resistor at UHF-band. The variable attenuator using the 3-dB coupler and the PIN diode is designed and implemented. The measured results for the variable attenuator by a network analyzer show that the insertion loss is below -l0dB, and the continuous variable attenuation range is about 10dB.

  • PDF

Numerical Study of Estimating the Arrival Time of UHF Signals for Partial Discharge Localization in a Power Transformer

  • Ha, Sang-Gyu;Cho, Jeahoon;Lee, Juneseok;Min, Byoung-Woon;Choi, Jaehoon;Jung, Kyung-Young
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.2
    • /
    • pp.94-100
    • /
    • 2018
  • Partial discharges (PDs) are electrical sparks that occur inside insulation between two conducting electrodes and can lead to the disastrous failure of insulation systems. To determine the location of a PD, a distributed array of UHF PD sensors is used to detect the electromagnetic (EM) signals emitted from the PD source, and the localization of the PD source can be estimated using the time difference of arrival (TDOA) between EM signals captured by the UHF PD sensor array. There are four popular methods to estimate the TDOA-the first peak method, the cross-correlation method, the energy criterion method, and the average time window threshold method. In this work, we numerically investigate the influence of noise on estimating the TDOA for the four different methods. Numerical results show that the energy criterion method is more robust against noise than other methods.

Partial Discharge Electromagnetic Wave Penetration Characteristics Throughout Transformer Winding (전자기파 부분방전 신호의 권선 투과 특성)

  • Ju, Hyung-Jun;Han, Ki-Son;Yoon, Jin-Yul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.10
    • /
    • pp.809-813
    • /
    • 2010
  • Frequency domain measurement of propagation loss for ultra high frequency (UHF) partial discharge in the winding of power transformer using a spectrum analyzer and pulse generator is presented. We compared the performance of the method using a network analyzer with and without a winding. Using a network analyzer simplifies the measurement and offers better dynamic range and frequency range. It also provides precise propagation loss within the winding in frequency domain at UHF range. We applied this method to measure UHF propagation loss of transformer mock-up, modeled 154 kV 20 MVA power in KEPCO substation.