• Title/Summary/Keyword: UHF method

Search Result 176, Processing Time 0.033 seconds

A study on the Analysis Method of Interference using SEAMCAT in UHF band (UHF대역에서의 SEAMCAT을 이용한 간섭 분석기법에 관한 연구)

  • Cho, Seung-Il;Jang, Kyoung-Seung;Kang, Sung-Chul;Lee, Joo-Hwan;Kang, Jeong-Jin;Choi, Gyoo-Seok;Cha, Jae-Sang;Kim, Seong-Kweon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.8 no.6
    • /
    • pp.119-125
    • /
    • 2008
  • In this paper, we proposed the modeling of UHF frequency environment in a random mountainous area with line of sight. A transmitting station is defined as wanted transmitter(Wr) and a receiving station is defined as victim receiver(Vr). These set up victim link. A interference transmitter(It) and wanted receiver(Wr) set up interference link. We compared measured data at random mountainous area with data of the result using spectrum engineering advanced monte calo analysis tool(SEAMCAT), interference simulation based on the monte-carlo method. The desired received signal strength(dRSS) of SEAMCAT had the calculated error of 70% from the measured received signal strength because there was a topographical effect. Therefore, the effect of diffraction interference was included to lessen the power of transmitter in the proposed simulation. The cause of received power error are cable loss and errors of a measuring instrument. The proposed simulation modeling in UHF frequency environment expect that is the useful study on interference analysis and reassignment of broadcasting frequency.

  • PDF

A Study of the Method for External Noise Shielding using the GIS UHF Sensor Module Applied to the Partial Discharge Signal Sensitivity and Method of Frequency Transforming in the Internal GIS (GIS내부의 부분방전신호 감도개선 및 주파수변환기법에 의한 GIS UHF Sensor 모듈의 외부노이즈차폐기법에 관한 연구)

  • Lee, Seung-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.728-732
    • /
    • 2010
  • GIS(Gas insulated switching gear) is power equipment with excellent dielectric strength and is economy merit in high confidence and stability. Recently, because equipment of GIS was occurring problem of confidence used for a long time, partial discharge on-line diagnosis systems have been importantly recognized. Partial discharge (PD) detection is an effective means for monitoring and evaluation of dielectric condition of gas insulated system (GIS). The ultra-high-frequency (UHF) PD detection technique can detect and locate the PD sources inside GIS by detecting electromagnetic wave emitted from PD source. Therefore, real-time diagnostic system using UHF detection method has been developed for this application is being expanded gradually. However, the signal of partial discharge occurring in SF6 gas is very weak and susceptible to external noises which mainly consist of PD in air. Thus, it is important to distinguish the PD in SF6 gas more sensitively from the external noises. Unfortunately, these external noise signals and the partial discharge signals have very similar characteristics. Therefore, to solve this problem, we need the signal processing method for distinguish partial discharge signals with external noise signals for improvement of SNR(signal to noise ratio) and sensitivity. In this paper, we proposed internal signal processing method for removing external noise signals with built-in pre.amplifier and frequency conversion circuit.

The Study of The Calibration Method for The UHF PD Detection in GIS (GIS에서 UHF 부분방전 검출법의 교정방안 연구)

  • Lee, W.Y.;Chong, J.K.;Choi, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2290-2292
    • /
    • 1999
  • The Ultra-High Frequency(UHF) method for detecting a partial discharge in Gas-Insulated Substation(GIS) has some advantages compared to a conventional method(IEC 270) but there is a shortage in view of a quantitative analysis. Therefore, this paper describes the implementation of a calibrator and the calibration process based on it. And its characteristics are confirmed through the experiment using the 362kV GIS chamber.

  • PDF

GISPD Analysis Using UHF Dual-Band Method (UHF이중대역법을 이용한 GISPD분석)

  • Kim, Kwang-Hwa;Yi, Sang-Hwa;Choi, Jae-Gu
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1860-1862
    • /
    • 2004
  • It is widely known that the ultra high frequency (UHF) method that detects the electromagnetic wave of the PD pulses in the gas insulated space is one of the most competitive methods for its high sensitivity. From the above point of view, this paper describes the characteristics of GIS PD signals measured with ultra wide band (UWB) GIS PD detecting system in which PD signals are detected into the dual UHF band. The UWB PD detection system consists of the UWB UHF coupler, the UWB low noise amplifier (LNA) and the oscilloscope. The dual bands for PD signals are 0.5-2GHz(full band) and 1-2GHz(high band). As results, it was found that the partial discharges of each defect have their own characteristic pattern and the ratio of High band to Full band increases with gas pressure.

  • PDF

GlSPD Analysis Using UHF Dual-Band Method (UHF 이중대역법을 이용한 GIS PD 분석)

  • Yi, Sang-Hwa;Choi, Jae-Gu;Kim, Kwang-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2004.11d
    • /
    • pp.63-66
    • /
    • 2004
  • It is widely known that the ultra high frequency (UHF) method that detects the electromagnetic wave of the PD pulses in the gas insulated space is one of the most competitive methods for its high sensitivity. From the above point of view, this paper describes the characteristics of GIS PD signals measured with ultra wide band (UWB) GIS PD defecting system in which PD signals are defected into the dual UHF band. Thc UWB PD detection system consists of the UWB UHF coupler, the UWB low noise amplifier (LNA) and the oscilloscope. The dual bands for PD signals are 0.5-2GHz(full band) and 1-2GHz(high band). As results, it was found that the partial discharges of each defect have their own characteristic pattern and the ratio of High hand to Full band increases with gas pressure.

  • PDF

A Study for the Fault Location of Insulation Defects considering Waveguide Characteristics in GIS (GIS의 도파관 특성을 고려한 절연결함 위치판정에 관한 연구)

  • Lee, Seung-Chul;Jung, Seung-Yong;Lee, Jae-Ho;Koo, Ja-Yoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.252-255
    • /
    • 2008
  • A study for discharge pattern analysis partial and fault location by use of UHF sensors in GIS. However, in the latter case, the results considered the velocity of EM waves modified by the waveguide characteristics of GIS bus bar were not reported yet. In this paper, UHF wide band sensor to detect partial discharge signals have been designed and manufactured to get the widest band characteristic by an application of Fat-Dipole UHF antenna and the result that the transmission velocity of EM waves is 2/3 of the light have been got through the consideration of waveguide characteristics. Also, to verify applicability on site of the developed method, self-designed external type UHF sensor have been installed on operating GIS in Korea Midland Power co. and detected location of the fault. Through the fault have been found at the location, the reliability of the developed method have been proved.

A Technical Trend on UHF Techniques for On-Line PD Monitoring and Site Testing for Transformer (전력용 변압기의 온라인 PD 모니터링과 시험을 위한 UHF 기술 동향)

  • Kim, Byung-Woo;Kim, Yun-Seok;Kim, Chang-Bok;Cho, Soo-Young;Choi, Young-Il;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1972-1973
    • /
    • 2007
  • A field-oriented UHF system for on-line PD monitoring of transformers is designed, which has been installed inside the oil tank of a transformer. This system has successfully captured long intermittent discharge signals that hadn't been detected through conventional techniques, and solved the problem successfully. The results demonstrate that UHF technique has great advantages for on-line PD monitoring of transformers. By adopting the peak detection technique, it becomes easy and effective for the transplantation of the phase-resolved pattern recognition technique from conventional method to UHF method, and then to realize continuous on-line monitoring, source characterization and trending analysis.

  • PDF

Characteristics of Radiated Electromagnetic Waves in Model GIS with Electrical Trouble and Design of Insulted Diagnosis UHF Sensor (모의 GIS의 전기적 이상에 따른 방사전자파의 특성과 절연진단용 UHF 센서 설계)

  • Park, Kwang-Seo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.5
    • /
    • pp.47-52
    • /
    • 2008
  • In this paper partial discharge were simulated by conducted particle, a fine protrusion, surface discharge, which could be easy accumulated charge and concentrated electric field in the model GIS. In this times this paper measured and analyzed the radiated electromagnetic waves by using spectrum analyzer and antenna ($30{\sim}2,000[MHz]$ for measurement of EMI EMC in accordance with occurrence and propagation of partial discharge. In the basis of this results, a novel UHF(Ultra High Frequency) spherical sensor is presented. The measured impedance bandwidth of the proposed antenna is from 0.3[GHz] to 1.7[GHz]. Form results of this study, this antenna will be playing an important role for the sensor for insulation diagnosis system by UHF method of real site GIS and power equipment using $SF_6$ gas.

Performance Verification of the Gas Insulated Switchgear using UHF Partial Discharge Diagnosis Method (UHF 부분방전 진단법에 의한 가스절연 개폐장치의 성능검증)

  • Kim, J.B.;Jung, J.R.;Kim, M.S.;Song, W.P.;Kim, M.H.;Ko, H.S.;Choi, I.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.132-135
    • /
    • 2004
  • In generally, compared with VHF band, electromagnetic waves of UHF band have a low influence for external noise. We can detect the real abnormality with several pC in GIS using UHF method. Recently, it has applied to use the external UHF sensor attached on spacer to GIS of existing substation. In this paper, we firstly described the technique of the partial discharge measurement using frequency analysis and phase analysis in UHF band. Secondly, we presented the results of sensitivity, the relationship of dBm-pC and diagnosis of the reason of PD source by phase analysis. And then, we report the diagnosis result of partial discharge on 800kV GIS in domestic substation. rge diagnosis of GIS.

  • PDF

Trend in UHF Technique for On-Line PD Monitoring of Transformer (변압기의 온라인 PD 모니터링을 위한 UHF 기술의 동향)

  • Oh, Yong;Yun, Ju-Ho;Kim, Yun-Seok;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.527-528
    • /
    • 2007
  • A field-oriented UHF system for on-line PD monitoring of transformers is designed, which has been installed inside the oil tank of a 220kV transformer in a substation. This system has successfully captured long intermittent discharge signals that hadn't been detected through conventional techniques, and solved the problem successfully. The results demonstrate that UHF technique has great advantages for on-line PD monitoring of transformers. By adopting the peak detection technique, it becomes easy and effective for the transplantation of the phase-resolved pattern recognition technique from conventional method to UHF method, and then to realize continuous on-line monitoring, source characterization and trending analysis.

  • PDF