Performance Evaluation of SHF Sensor for Partial Discharge Signal Detection on DC Rectifier (DC 정류기 부분방전 신호검출을 위한 SHF 센서의 성능평가)

  • Jung, Ho-Sung;Park, Young;Na, Hee-Seung;Jang, Soon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.7
    • /
    • pp.1056-1060
    • /
    • 2012
  • Online monitoring system is becoming an essential element of railway traction system for utilized to condition based malignance management and various techniques currently employed in railway traction system. Among the various techniques, it is efficient to detect partial discharge signals by electromagnetic wave detection in order to detect insulation fault of rectifier. Although VHF (Very High Frequency), UHF (Ultra High Frequency) sensors were adopted to detect partial discharge of power facilities, due to characteristics of urban railway, excessive noise occurs from 500 MHz to 1.5 GHz on UHF bandwidth. In this paper a new measurement system able to monitoring the conditions of power facilities on DC substation in metro was studied and set up. The system uses UHF sensors to measure the partial discharge of the rectifier due to electric faulting and dielectric breakdown. Comparison and estimation for performance of SHF sensor which had devised to detect partial discharge signal of urban railway rectifier has conducted. In order to estimate performance of SHF sensor, we have compared the sensor with existing UHF sensor on sensitivity upon frequency bandwidth generated by pulse generator, and also we have verified performance of the SHF sensor by detection results of partial discharge signal from urban railway rectifier.

Propagation Characteristics of Ultra High Frequency Partial Discharge Signals in Power Transformer (전력용변압기에서 UHF 부분방전 신호의 전파 특성)

  • Yoon, Jin-Yul;Han, Ki-Son;Ju, Hyung-Jun;Goo, Sun-Geun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.10
    • /
    • pp.798-803
    • /
    • 2010
  • This paper describes the characteristics of electromagnetic wave propagation in power transformer. A transformer which is similar to 154 kV single phase on-site transformer unit was provided for the purpose of the experiment. The 12 dielectric windows on the transformer enclosure to install UHF (ultra high frequency) sensors and the full scale mock ups of winding and the core were also equipped in the transformer. Every sensors to be installed to the transformer was tested and verified whether they show same characteristics or not before the experiment. A discharge gap which was used as a PD (partial discharge) source moved to several necessary locations in the transformer to simulate dielectric defects. Propagation times of electromagnetic wave signal from PD source to sensors decided by the routes of both reflection phenomenon and diffraction phenomenon were compared each other. The experimental results showed propagation route of the PD signal makes an effect on the frequency spectrum of front part of the signal and the magnitude of the signal and propagation time of the signal when the signal is captured on the sensor.

Analysis of Partial Discharge Signal Propagation Characteristics in GIS Using FEM/EMTP (FEM/EMTP를 이용한 GIS내 부분방전 펄스의 감쇠특성 해석)

  • Lee, D.H.;Lee, H.D.;Sin, Y.S.;Lee, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.255-257
    • /
    • 2004
  • This paper was studied electromagnetic field distribution and damping of PD(Partial Discharge) signal in GIS(Gas Insulated Switchgear). Cut-off frequency of electromagnetic wave propagation modes were computed, electromagnetic field distribution of propagation modes in GIS by FEM(Finite Element Method) were simulated and simulated damping characteristic of electromagnetic waves in GIS by EMTP(Electromagnetic Transient Program) when generated PD pulse. Frequency band of $TE_{mn}/TM_{mn}$ modes were determinated by simulation results of electromagnetic field distribution and were discussed optimal position of UHF sensor from this results. Equivalent circuit was used to simulate signal damping of PD pulse in GIS by EMTP and compared with measured results in laboratory of KERI.

  • PDF

Characteristics of Ultra High Frequency Partial Discharge Signals of Turn to Turn Defect in Transformer Oil (절연유 내 변압기 Turn간 결함에 의한 부분방전의 극초단파 전자기파 신호 특성)

  • Yoon, Jin-Yul;Ju, Hyung-Jun;Goo, Sun-Geun;Park, Ki-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.2000-2004
    • /
    • 2009
  • In general, for the condition monitoring of a power transformer using the UHF PD measuring technique, detection of any partial discharge, identifying the defect in the transformer and locating the insulation defect are necessary. In this paper one of the most frequent detects which can result in turn to turn fault in power transformer was examined for identifying the defect. In order to model the defect, as a discharge source, a partial discharge cell was used for experimental activity. Magnitude of electromagnetic wave signals and corresponding amount of apparent discharge were measured simultaneously against phase of applied voltage to the discharge cell. Frequency range and phase resolved partial discharge signals were measured and analyzed. The results will be contributed to build the defect database of power transformer and to decrease the occurrence of transformer faults.

Analysis of Partial Discharge Signal Propagation Characteristics in GIS Using FEM (FEM을 이용한 GIS내 부분방전 신호의 전파특성 해석)

  • Lee, D.H.;Lee, H.D.;Lee, Y.H.;Park, K.H.;Ryu, K.Y.;Sin, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1835-1837
    • /
    • 2004
  • The UHF electromagnetic waves excited by PD pulses propagate along the GIS busbar not only TEM mode, but also TE and TM mode. Generally the waves detected by the UHF sensors are those of high order modes and such waves can only propagate the higher than cut-off frequency. In this paper, computed cut-off frequency of 362[kV] GIS by each modes and simulated electromagnetic field of each propagation modes by FEM(Finite Element Method) program. Frequency band of each TEmn/TMmn modes were determinated by simulation results and were discussed optimal position of UHF sensor from this results.

  • PDF

Analysis of Partial Discharge Signal Propagation Characteristics in GIS using FEM (FEM을 이용한 GIS내 부분방전 신호의 전파특성 해석)

  • Kim Jae-Chul;Lee Do-Hoon;Song Seung-Yeop;Kim Kwang-Whoa
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.11
    • /
    • pp.624-629
    • /
    • 2004
  • The UHF electromagnetic waves excited by PD pulses propagate along the GIS busbar not only TEM mode, but also TE and TM mode. Generally the waves detected by the UHF sensors are those of high order modes and such waves can only propagate higher than cut-off frequency. In this paper, the cut-off frequency of 362[kV] GIS for each modes is computed and the electromagnetic field of each propagation modes is simulated by FEM(Finite Element Method) program. Frequency band of each TEmn/TMmn modes was determinated by simulation results and was discussed optimal position of UHF sensor from this results.

Filter Test for Partial Discharge Detection of Underground Distribution Cables (지중배전케이블의 PD 검출용 필터 시험 연구)

  • Lee, Yong-Sung;Kim, Jung-Yoon;Lee, Kwan-Woo;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.215-216
    • /
    • 2005
  • To decrease and remove of much noises that is detected in PD (partial discharge) measuring test. we forced on detection of those. We made W-LC filter for measuring PD. which adapted that to field test. We tested after design laboratory circumstances like field line. and then the phase change properties of detected signal in UHF sensor were measured by Lemke Probe and oscilloscope (TDS-3054. Tektronix). Eventually we checked decrement of noises from experimental result. Also from experimental result at the joint box of 22.9[kV] distribution line. we obtained reasonable data which enable noises to decrease. Hereafter those results will be adapted at ultra-high voltage for trouble prevention and on-line cable watch. diagnosis of those.

  • PDF

Performance verification and improvement of the frequency analysis unit for GIS Preventive & Diagnostic Monitoring System (GIS 예방진단시스템 주파수 분석장치 성능개선 및 검증)

  • Kim, Won-Gyu;Kim, Min-Soo;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.3
    • /
    • pp.485-491
    • /
    • 2015
  • This paper shows the design improvement and test model of FAU (Frequency Analysis Unit) in PDD (Partial Discharge Diagnosis system) for 800kV GIS (Gas Insulated Switchgear). We found some problems during operation of previous FAU, such as the aging of fiber-optic converter that can cause communication error, the malfunction of signal analysis circuit etc. And then we solved those problems by design improvement and verified the performance through type test. To monitor partial discharge, the performance of UHF sensor is important but the performance of frequency analysis unit is also very important. So we solved communication error, the malfunction of signal analysis circuit and then increased the operation reliability of FAU by improving fiber-optic converter and signal analysis circuit. Accredited testing laboratory carried out the performance verification test according to performance test criteria and procedure of reliability test standards, IEC-60225, 61000 and 60068 etc. We confirmed the test results which correspond with the performance test criteria.

Characteristics of Ultra High Frequency Partial Discharge Signals from Metallic Particle Defected Oil-paper Insulation in Transformer (변압기 절연지 표면 금속 이물질 방전에 의한 극초단파 신호특성)

  • Yoon, Jin-Yul;Ju, Hyung-Jun;Goo, Sun-Geun;Park, Ki-Jun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.10
    • /
    • pp.879-883
    • /
    • 2009
  • This paper was provided to help in detecting defects in power transformer. For this purpose, a partial discharge cell was designed and manufactured as a discharge source to simulate particle defected paper-oil insulation in power transformer. Experimental set-up for measuring PD signals was described. Magnitude of electromagnetic wave signals and corresponding amount of apparent discharge were measured simultaneously against phase of applied voltage to the discharge cell. Frequency range and pattern of PRPD(Phase Resolved Partial Discharge) of partial discharge signals were examined and analyzed. The results will be contributed to build the defect database of power transformer and to decrease the substation faults.

Filter Design for High-Frequency Partial Discharge (고주파 부분 방전을 위한 필터 설계)

  • Oh, Yong;Gil, Hyoung-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.239-242
    • /
    • 2008
  • In this paper, we developed HPF (high pass filter) consisted of lumped LC components to decrease the noises that are detected in PD (partial discharge) measuring test, and adapted it to field test. We tested under laboratory circumstances like the fields, and measured the phase change properties of detected signal in UHF sensor with Lemke probe and oscilloscope (TDS-3054, Tektronix).