• Title/Summary/Keyword: UHF Band

Search Result 277, Processing Time 0.032 seconds

Analysis and the measurement of the variation of electric field in air and oil using optical measuring system (광계측 시스템을 이용한 유.기중 코로나 방전의 전계변화 측정 및 비교분석)

  • Ma, Ji-Hoon;Ryu, Cheol-Hwi;Kang, Won-Jong;Chang, Yong-Moo;Koo, Ja_Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1668-1670
    • /
    • 2002
  • Since more than two decades, the conventional PD detecting systems have been employed in order to detect the partial discharges occurring inside the HV power apparatus for their diagnosis by use of different type of detection such as acoustic and UHF detection method. Regardless of their wide on-site application, a certain number of technical inconveniences have been disclosed as follows : multistage amplification. large volume, susceptible to external noise and high price. In this respect, the optical measurement techniques are widely proposed in these days in this concerned field ascribed to the following advantages : immune to external EMI noise and broad band response of the Pockels cell covering from DC to GHz. However, the reliability of several proposed techniques enabling to measure the electric field inside the large high power apparatus has not yet been well approved In this work, an optical measuring system, based on the Pockels effect, has been developed for measuring the field variation due to the corona discharges occurring in air and in oil. This system consists of He-Ne laser, single mode optical fiber, multi mode optical fiber, polarizing film, Y-cut LiNbO3 cell, photo detector, digital oscilloscope and personal computer with GPIB. For this purpose, optical probe has been specially designed and realized and put into the needle-plane electrode. Afterward, same measurement is carried out in oil. We demonstrate the characteristic of the optical measuring system and the measurement results.

  • PDF

Telemetry capsule for pressure monitoring in the gastrointestinal tract (소화관 내 압력 측정을 위한 텔레메트리 캡슐 구현)

  • Yoon, Ki-Won;Woo, Sang-Hyo;Lee, Jyung-Hyun;Moon, Yeon-Kwan;Park, Hee-Joon;Won, Chul-Ho;Kim, Byung-Kyu;Choi, Hyun-Chul;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.211-218
    • /
    • 2005
  • As the cause and the treatment about gastrointestinal disease has been issued recently, the importance of measuring the pressure in the gastrointestinal tract has been increased. However, the conventional measurement methods of the pressure in the gastrointestinal tract cause the patients' pain and inconvenience as well as an inaccurate pressure measurement. In this paper, the pressure monitoring telemetry system has been designed and implemented for an accurate pressure measurement inside the gastrointestinal tract with minimizing pain and inconvenience. The pressure monitoring telemetry system is composed of a pressure measurement capsule and an external receiver. The capsule has been miniaturized into the same size of a vitamin tablet so that the capsule can be swallowed through the oral cavity. After the capsule acquires and encodes the pressure data in the gastrointestinal tract, the encoded pressure data are modulated by frequency shift keying (FSK) and transmitted with ultrahigh frequency (UHF) band signal to the outside of a body. The performance of the telemetry capsule for monitoring pressure in the gastrointestinal tract is demonstrated by the results of animal in-vivo experiments.

System Design of SIGMA(KHUSAT-3) CubeSat Mission

  • Lee, Seongwhan;Lee, Junkyu;Kum, Kanghoon;Lee, Hyojeong;Seo, Junwon;Shin, Youra;Jeong, Seonyoung;Shin, Jehyuck;Cheon, Junghoon;Kim, Hanjun;Jin, Ho;Nam, Uk-Won;Kim, Sunghwan;Lee, Regina;Lessard, Marc R.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.54.1-54.1
    • /
    • 2014
  • Kyung Hee University has been developing a CubeSat for the space science mission called SIGMA (Scientific cubesat with Instrument for Global Magnetic field and rAdiation), which includes TEPC (Tissue Equivalent Proportional Counter) and a magnetometer. SIGMA has a 3-unit CubeSat, and the weight is about 3.2 kg. The main payload is TEPC which can measure the Linear Energy Transfer (LET) spectrum and calculate the equivalent dose for the complicated radiation field in the space. The magnetometer is a secondary payload using a miniaturized fluxgate magnetometer. We expect it to have a 1 nT resolution in the dynamic range of ${\pm}65535$ nT. An Attitude Control System (ACS) spins the SIGMA spacecraft 4 rpm with the spin axis perpendicular to the ecliptic plane. Full duplex communication is consists of VHF uplink and S-band and UHF downlink. In this paper, we introduce the system design and the scientific purpose of the SIGMA CubeSat mission.

  • PDF

A Study on Construction of Infrastructure for Handicapped Parking Areas Using RFID (RFID를 이용한 장애인전용 주차구역 서브시스템을 위한 기반시설 구축에 관한 연구)

  • Choi, Y.S.;Seong, H.K.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.8 no.1
    • /
    • pp.67-72
    • /
    • 2014
  • In this paper, we proposed A Study on Construction of Infrastructure for Handicapped Parking Areas Using RFID. This paper is Construction of the Handicapped Parking Areas infrastructure Using RFID with 900MHz band, and researched the optimal position of the tag attached on the vehicle and the location of RFID reader in order to raise the efficiency of RFID reader and the recognition rate by the handicapped vehicle. The result of research is shown the optimal position of RFID reader establishment when the height of RFID reader is 170cm in height and the angle of $80^{\circ}$ with the ground when the vehicle traveling direction of the antenna and the RFID reader when the surface and the angle of $90^{\circ}$ showed the best position RFID readers installed. Parking spaces for the disabled in accordance with these results the RFID readers installed and it works in conjunction with enforcement camera car tagged crackdown on vehicles and other general management, the system is built to allow handicapped parking spaces that meet the intent of the original purpose being used as expected to contribute significantly.

  • PDF

Design of a Broadband Printing RFID Tag Antenna with Low Performance Degradation Due to Nearby Dielectric Material (근접 유전체에 의한 성능 열화가 적은 광대역 프린팅 태그 안테나 설계)

  • Ji, Sung-Hwan;Han, Won-Keun;Park, Ik-Mo;Choo, Ho-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.8
    • /
    • pp.694-700
    • /
    • 2009
  • In this paper, we propose a RFID tag antenna with low performance degradation due to nearby dielectric materials. The proposed antenna is designed to be appropriate for ink printing fabrication. The antenna is designed to operate in UHF band of $860{\sim}960$ MHz. The antenna uses a T-matching network in the middle of the main body and two parasitic patches in vicinity for complex conjugate matching with a commercial tag chip. In addition, the two parasitic patches induce currents at different dielectric constants of nearby dielectric materials. This can minimize the performance degradation due to nearby dielectric materials. The measured results show the half power matching bandwidth from 844 MHT to 1,268 MHz. It exhibits the reading distance of about 3.5 m in free space when the tag antenna is used with the commercial reader antenna (transmitting power of 20 dBm and the reader antenna gain of 6 dBi). When the tag is attached on dielectric materials of wood and FR4, the resulting reading distances are 2.61 m and 2.51 m, respectively.

System Development of Cubsat SIGMA(KHUSAT-3)

  • Shin, Jehyuck;Lee, Seongwhan;Lee, Jung-Kyu;Lee, Hyojeong;Lee, Jeongho;Seo, Junwon;Shin, Youra;Jeong, Seonyeong;Cheon, Junghoon;Kim, Hanjun;Lim, Jeonghyun;Lee, Junmin;Jin, Ho;Nam, Uk-Won;Kim, Sunghwan;Lee, Regina;Kim, Hyomin;Lessard, Marc R.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.106-106
    • /
    • 2014
  • SIGMA (Scientific cubesat with Instrument for Global Magnetic field and rAdiation)는 근 지구공간에서 우주방사선량 측정과 자기장 변화 검출의 과학적 목적과 교육적 목적을 가지고 개발하고 있는 초소형 큐브위성이다. $100mm{\times}100mm{\times}340.5mm$의 크기로 약 3.6 kg의 무게를 가지며, 탑재체는 방사선에 대하여 인체와 동일한 산란 흡수 특성을 가진 Tissue Equivalent Proportional Counter (TEPC)와 자기장 측정을 위한 Magnetometer (Mag)이다. 위성체는 구조계, 자세제어계, 전력계, 명령 및 데이터처리계, 통신계로 구성되어있다. 구조계는 위성의 뼈대인 Chassis와 Mag deployer로 이루어져있고, 위성의 안정적인 자세유지를 목적으로 Attitude Control System (ACS) Board와 Torque Coil이 자세제어계로 구성된다. 전력의 생산과 공급 및 충전은 태양전지판과 Electrical Power System (EPS), 리튬 배터리로 구성된 전력계에서 이뤄지며, 명령 및 데이터처리계는 On Board Computer (OBC)와 Instrument Interface board (IIB)를 중심으로 서브시스템의 명령체계와 데이터처리를 다룬다. 통신계는 Uplink인 VHF 안테나와 Downlink인 UHF, S-band 안테나로 구성되며 지상과 명령을 송수신한다. SIGMA는 타임인터럽트 기능을 활용한 Flight Software (FSW)로 운용되며 임무에 따른 6가지 모드의 시나리오로 위성을 운용한다. 이에 SIGMA의 개발과 테스트 결과를 소개한다. 본 큐브위성 개발기술을 바탕으로 향후 천문관측용 위성에도 활용할 예정이다.

  • PDF

Development of EM Wave Absorber for Increasing Communication Range in RFID System (RFID 시스템의 통신 거리 증대를 위한 전파흡수체 개발)

  • Park, Soo-Hoon;Kim, Dong-Il;Yoon, Sang-Gil;Yoo, Gun-Suk;Jeong, In-Seong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.3
    • /
    • pp.222-229
    • /
    • 2009
  • In this paper, we designed and fabricated the EM wave absorbers for preventing the reduction of the communication range when RFID Tag is approached to a metal plate. The EM wave absorber samples were fabricated with difference composition ratios of Amorphous metal powder and CPE, the absorption abilities of which were simulated by substituting different thicknesses of the EM wave absorbers. Then the EM wave absorbers are manufactured based on the simulated results. By using the EM wave absorbers, we have confirmed the improvement effect of RFID tag antenna and the increase of communication range of RFID system. As a result, it was cleary shown that the communication range of RFID system is improved by adopting the EM wave absorber with the composition ratio of Amorphous metal powder:CPE=80:20 wt.% and the thickness of 4 mm. Thus, it was confirmed that the proposed EM wave absorber can increase the communication range of RFID system from 0.8 m to 5.2 m in UHF band.