• 제목/요약/키워드: UF-SWRO

검색결과 6건 처리시간 0.016초

응집-UF 전처리 공정에 의한 잔류 금속염이 역삼투막에 미치는 영향 (Effect of residual metal salt on reverse osmosis membrane by coagulation-UF pretreatment process)

  • 고길현;김수현;강임석
    • 상하수도학회지
    • /
    • 제33권6호
    • /
    • pp.413-420
    • /
    • 2019
  • Pretreatment system of desalination process using seawater reverse osmosis(SWRO) membrane is the most critical step in order to prevent membrane fouling. One of the methods is coagulation-UF membrane process. Coagulation-UF membrane systems have been shown to be very efficient in removing turbidity and non-soluble and colloidal organics contained in the source water for SWRO pretreatment. Ferric salt coagulants are commonly applied in coagulation-UF process for pretreatment of SWRO process. But aluminum salts have not been applied in coagulation-UF pretreatment of SWRO process due to the SWRO membrane fouling by residual aluminum. This study was carried out to see the effect of residual matal salt on SWRO membrane followed by coagulation-UF pretreatment process. Experimental results showed that increased residual aluminum salts by coagulation-UF pretreatment process by using alum lead to the decreased SWRO membrane salt rejection and flux. As the salt rejection and flux of SWRO membrane decreased, the concentration of silica and residual aluminum decreased. However, when adjusting coagulation pH for coagulation-UF pretreatment process, the residual aluminum salt concentration was decreased and SWRO membrane flux was increased.

Ultrafiltration as a pretreatment for seawater desalination: A review

  • Lau, W.J.;Goh, P.S.;Ismail, A.F.;Lai, S.O.
    • Membrane and Water Treatment
    • /
    • 제5권1호
    • /
    • pp.15-29
    • /
    • 2014
  • Reverse Osmosis (RO) desalination has gained wide and increasing acceptance around the world as a straightforward undertaking to alleviate the alarming water crisis. An enhanced monitoring of the quality of the water feeding in seawater RO (SWRO) plant through the application of an effective pretreatment option is one of the keys to the success of RO technology in desalination plants. Over the past 10 years, advances in ultrafiltration (UF) membrane technologies in application for water and wastewater treatment have prompted an impetus for using membrane pretreatment in seawater desalination plants. By integrating SWRO plant with UF pretreatment, the rate of membrane fouling can be significantly reduced and thus extend the life of RO membrane. With the growing importance and significant advances attained in UF pretreatment, this review presents an overview of UF pretreatment in SWRO plants. The advantages offered by UF as an alternative of pretreatment option are compared to the existing conventionally used technologies. The current progress made in the integration of SWRO with UF pretreatment is also highlighted. Finally, the recent advances pursued in UF technology is reviewed in order to provide an insight and hence path the way for the future development of this technology.

UF-SWRO 혼합공정을 이용한 해수담수화 파일럿 플랜트에서의 해수와 기수의 블렌딩을 통한 보론 및 휴믹산 제거 특성 (Removal Characteristics of Boron and Humic Acid by Pre-blending Seawater and Brackish Water Using UF-SWRO Hybrid Process in Pilot-scale Plant for Desalination)

  • 김원규;신성훈;이학수;우달식
    • 대한환경공학회지
    • /
    • 제38권1호
    • /
    • pp.34-41
    • /
    • 2016
  • UF (ultrafiltration)-SWRO (seawater reverse osmosis) 공정을 이용하여 해수와 기수의 유입수 블렌딩(pre-blending)이 보론(boron)과 휴믹산(humic acid)의 제거에 미치는 영향을 조사하였다. 유입수 블렌딩은 TDS (total dissolved solids) 농도를 기준으로 15,000 mg/L~27,000 mg/L까지 설정하였으며, RO에서의 보론 제거특성을 분석하였다. 또한, 동일한 TDS 농도범위에서 휴믹산을 주입하여 유기물 제거 특성을 알아보았다. 보론은 TDS 농도가 높아질수록 제거율은 76.60% - 83.27%로 높게 나타났지만, 최종 생산된 생산수의 보론 농도는 0.48 mg/L-0.69 mg/L로 높아져 유입수 내 보론 농도가 다량 유입될 시 유입수 블렌딩이 필요할 것으로 판단된다. 휴믹산의 경우 10 mg/L 수준일 경우 TDS 농도 22,500 mg/L가 27,000 mg/L 보다 제거율이 높게 나타났지만, 휴믹산이 5 mg/L 수준일 경우 TDS 농도 18,000 mg/L가 15,000 mg/L보다 높게 나타났다. 한편, 휴믹산이 주입되었을 때 UF-SWRO 공정에서는 오히려 플럭스(flux)와 회수율(recovery rate)이 증가하는 효과를 나타내었는데, 이는 파울링 물질이 $Ca^{2+}$와 휴믹산의 결합에 의해 대부분 제거되어 나타난 것으로 판단된다. 따라서 UF-SWRO를 이용한 해수 담수화 시 보론 농도와 휴믹산 제거측면에서 TDS 농도가 낮을수록 유리하다고 판단된다.

Pretreatment in Reverse Osmosis Seawater Desalination: A Short Review

  • Valavala, Ramesh;Sohn, Jin-Sik;Han, Ji-Hee;Her, Nam-Guk;Yoon, Yeo-Min
    • Environmental Engineering Research
    • /
    • 제16권4호
    • /
    • pp.205-212
    • /
    • 2011
  • Reverse osmosis (RO) technology has developed over the past 40 years to control a 44% market share in the world desalting production capacity and an 80% share in the total number of desalination plants installed worldwide. The application of conventional and low-pressure membrane pretreatment processes to seawater RO (SWRO) desalination has undergone accelerated development over the past decade. Reliable pretreatment techniques are required for the successful operation of SWRO processes, since a major issue is membrane fouling associated with particulate matter/colloids, organic/inorganic compounds, and biological growth. While conventional pretreatment processes such as coagulation and granular media filtration have been widely used for SWRO, there has been an increased tendency toward the use of ultrafiltration/microfiltration (UF/MF) instead of conventional treatment techniques. The literature shows that both the conventional and the UF/MF membrane pretreatment processes have different advantages and disadvantages. This review suggests that, depending on the feed water quality conditions, the suitable integration of multiple pretreatment processes may be considered valid since this would utilize the benefits of each separate pretreatment.

응집-UF 전처리 공정이 압력지연삼투 공정에 미치는 영향 (Effects of coagulation-UF pretreatment on pressure retarded osmosis membrane process)

  • 고길현;김수현;김정선;강임석
    • 상하수도학회지
    • /
    • 제35권4호
    • /
    • pp.285-292
    • /
    • 2021
  • Osmotic power is to produce electric power by using the chemical potential of two flows with the difference of salinity. Water permeates through a semipermeable membrane from a low concentration feed solution to a high concentration draw solution due to osmotic pressure. In a pressure retarded osmosis (PRO) process, river water and wastewater are commonly used as low salinity feed solution, whereas seawater and brine from the SWRO plant are employed as draw solution. During the PRO process using wastewater effluent as feed solution, PRO membrane fouling is usually caused by the convective or diffusive transport of PRO which is the most critical step of PRO membrane in order to prevent membrane fouling. The main objective of this study is to assess the PRO membrane fouling reduction by pretreatment to remove organic matter using coagulation-UF membrane process. The experimental results obtained from the pretreatment test showed that the optimum ferric chloride and PAC dosage for removal of organic matter applied for the coagulation and adsorption process was 50 mg/L as FeCl3 (optimum pH 5.5). Coagulation-UF pretreatment process was higher removal efficiency of organic matter, as also resulting in the substantial improvement of water flux of PRO membrane.

전산유체해석기법을 이용한 용존공기부상공정의 유동해석 (Simulation study of DAF flotation basin using CFD)

  • 박병성;우성우;박성원;민진희;이우녕;유수남;전갑진
    • 상하수도학회지
    • /
    • 제27권2호
    • /
    • pp.261-272
    • /
    • 2013
  • Algae boom (Red tide) in south coastal area of Korea has been appeared several times during a decade. If algae boom appears in the desalination plant, media filter and UF filter are clogged quickly, and the plant should be shutdown. In general, Algae can be removed from water by flotation better than by sedimentation, because of the low density of algal cell. The purpose of this study conducts the CFD simulation of DAF flotation basin to apply the design of the dissolved air flotation with ball filter in the Test Bed for SWRO desalination plant. In this study, Eulerian-Eulerian multiphase model was applied to simulate the behavior of air bubbles and seawater. Density difference model and gravity were used. But de-sludge process and mass transfer between air bubbles and seawater were ignored. Main parameter is hydraulic loading rate which is varied from 20 m/hr to 27.5 m/hr. Geometry of flotation basin were changed to improve the DAF performance. According to the result of this study, the increase of hydraulic loading rate causes that the flow in the separation basin is widely affected and the concentration of air is increased. The flow pattern in the contact zone of flotation basin is greatly affected by the location of nozzle header. When the nozzle header was installed not the bottom of the contact zone but the above, the opportunity of contact between influent and recycle flow was increased.