• 제목/요약/키워드: UF pre-treatment

검색결과 20건 처리시간 0.018초

UF 막 여과 공정의 효과적인 전처리 공정으로 분류교반고액분리조(噴流攪拌固液分離槽) (Jet Mixed Separator: JMS) 도입 효과에 관한 연구 (A Study on Effect of Jet Mixed Separator Combination for Pre-treatment of Ultrafiltration Membrane Filtration Process)

  • 이상협;장낙용;渡辺義公
    • 상하수도학회지
    • /
    • 제19권1호
    • /
    • pp.38-46
    • /
    • 2005
  • In this research, we tried to combine the coagulation/sedimentation process as pre-treatment with UF membrane filtration to reduce the membrane fouling and to improve the permeate water quality. We used the Jet Mixed Separator (JMS) as coagulation/sedimentation process. We observed that the HPC and E.Coli can't be removed through the direct UF memebrane filtation of surface water. The removal efficiency of dissolved organic substances, indicated by E260 and DOC, was 40% and 15%, respectively. However, the removal efficiency of it increased two time as a result of combination of JMS process as coagulation/sedimentation pre-treatment. This was resulted from the formation of high molecular humic micro-floc through JMS process. The accumulation amount of irreversible cake layer which was not removed by backwashing was less than direct UF membrane filtration of surface water. Moreover, the loading rate of fouling induced substances, such as humic substances and suspended substances, on membrane surface decreased drastically through JMS process. As a result, the accumulation amount of irreversible cake on membrane surface was decreased.

가정용 정수시스템의 바이러스 제거 (Removal of Virus in Home Drinking Water Treatment Systems)

  • 김영진;오남순;정문호
    • 한국환경보건학회지
    • /
    • 제26권4호
    • /
    • pp.45-48
    • /
    • 2000
  • Reverse osmosis filtration(RO) system and ultrafiltration(UF) system are principally use for domestic home drinking water treatment systems. The object of this study is to make a comparison between two systems in terms of theirs abilities to remove RNA coilphage QB as an indicator of pathogenic enteroviruses. The virus removal ratio of RO system was 99.999%, which was higher than EPA virus treatment guideline(99.99%). In the course of filtration, removal ratios of sediment filter, pre-carbon filter, reverse osmosis membrane and post-carbon filter were 75.000%, 93.208%, 99.997% and 99.999%, repectively. In case of UF system, virus removal ratio was 99.708%. Removal ratios of sediment filter, pre-carbon filter, post-carbon filter and ultrafiltration membration membrane were 71.038%, 91.530%, 98.283% and 99.708%, respecively, in UF steps. Therefore, RO system is more effective than UF system in virus removal.

  • PDF

분리막을 이용한 정수처리 System에서 처리공정 및 운전조건의 최적화에 관한연구 (A Study on the Opimization of Process and Operation Condition for Membrane System in Tap Water Treatment)

  • 오중교
    • 멤브레인
    • /
    • 제9권4호
    • /
    • pp.193-201
    • /
    • 1999
  • 기존의 정수처리 공정인 응집 침전 과정을 대체하여 분리막을 이용한 상수처리 시스템의 개발을 목적으로한다. 따라서 4가지 형태의 정수처리 공정과 분리막의 분획 분자량을 변화시켰을 때 막 투과수의 변화와 안정적이며 높은 투과수를 얻기 위해 필요한 운전 조건의 최적화를 실험하였다 실험결과 한외여과막이 정밀여과막보다 막 투과수 감소경향이 완만했으며 초기 투과수 회복율은 더 높았다. 수질 분석의 결과 한회여과막이 정밀 여과막보다 우수하였지만 전처리에 의한 차이는 나지 않았다. 운전 조건에 따른 flux 는 온도, 선속도가 높을수록 압력이 낮을수록 flux 감소율이 적은 경향을 나타내었다.

  • PDF

Comparative performance evaluation of two UF pilot plants at the Alto da Boa Vista WTP (São Paulo, Brazil)

  • Oliveira, T.F.;Mierzwa, J.C.
    • Membrane and Water Treatment
    • /
    • 제2권3호
    • /
    • pp.175-185
    • /
    • 2011
  • Ultrafiltration is an emerging technology for drinking water treatment because it produces better water quality as compared with conventional treatment systems. More recently, the combination of UF technology with other processes in order to improve its performance has been observed. These associations aim to maximize the contaminants removal and reduce membrane fouling. The operational performance of contaminants removal and water production of two UF pilot plants was compared. The first plant (Guarapiranga) was fed with raw water and the second plant (ABV) with pre-treated water by the coagulation, flocculation and sedimentation processes at Alto da Boa Vista WTP (Sao Paulo, Brazil). Both units operated continuously for approximately 2,500 hours, from September/2009 to January/2010. The results showed that the ABV UF pilot plant was able to operate at higher specific fluxes (6.2 $L.d^{-1}.m^{-2}.kPa^{-1}$ @ $25^{\circ}C$) than Guarapiranga (3.1 $L.d^{-1}.m^{-2}.kPa^{-1}$ @ $25^{\circ}C$). However, the number of chemical cleanings conducted in both pilot units during the considered operation period was the same (4 chemical cleanings for each plant), which shows that the pre-treatment reduced the membrane fouling. The water quality at ABV for all the variables analyzed was better, but the feed water quality was also better due to pretreatment. The rejection values for the different contaminants were higher at Guarapiranga mainly because of a pollution load reduction after pre-treatment at ABV. Even with the better performance of the ABV UF pilot plant, it is necessary to take into consideration the complexity of the complete treatment system, and also the costs involved in the construction and operation of a full-scale treatment unit.

해수담수화 전처리공정 비교 및 적용 방법 (Comparison and application method of seawater desalination pre-treatment process)

  • 임환규;김승현
    • 상하수도학회지
    • /
    • 제33권6호
    • /
    • pp.437-446
    • /
    • 2019
  • Reverse osmosis seawater desalination facilities can extend the cleaning cycle and replacement time of the reverse osmosis membrane by pretreatment process. Selection of pretreatment process depends on water quality. It was attempted in this study to select approriate pretreatment process for the Masan bay, which was high in particles and organic content. For this purpose, performances of pretreatment processes such as filter adsorber (FA), pore controllable fiber (PCF), and ultrafiltration (UF) were compared based on the silt density index (SDI). The SDI value of the filtrate should be less than 3. The study results showed that UF can produce the filtrate quality satisfying the requirement. However, the transmembrane pressure (TMP) of UF increased quickly, reaching 0.6 bar within 4 days. In order to secure stable operation, FA and PCF were combined with UF. The study results showed that combination of PCF and UF was able to extend the filtration duration (more than 2 months) until to reach TMP of 0.6 bar.

UF pretreatment at elevated temperature within the scheme of hybrid desalination: Performance and environmental impact

  • Agashichev, Sergey;Kumar, Jayesh
    • Membrane and Water Treatment
    • /
    • 제8권3호
    • /
    • pp.279-292
    • /
    • 2017
  • This study was aimed at ultrafiltration (UF) as a pretreatment before reverse osmosis (RO) within the scheme of hybrid reverse osmosis-multistage flush (RO-MSF) desalination. Seawater at elevated temperature (after MSF heat-exchangers) was used as a feed in this process. The pretreatment system was represented as a set of functionally-linked technological segments such as: UF filtration, backwashing, chemical- enhanced backwashing, cleaning, waste disposal, etc. The process represents the sequences of operating cycles. The cycle, in turn, consists of the following unit operations: filtration, backwashing and chemical-enhanced backwashing (CEB). Quantitative assessment was based on the following indicators: normalized permeability, transmembrane pressure, specific energy and water consumption, specific waste generation. UF pre-treatment is accompanied by the following waste streams: $W1=1.19{\times}10$ power of $-2m^3$ (disposed NaOCl with 0.0044% wt.)/$m^3$ (filtrate); $W2=5.95{\times}10$ power of $-3m^3$ (disposed $H_2SO_4$ with 0.052% wt.)/$m^3$(filtrate); $W3=7.26{\times}10$ power of $-2m^3$ (disposed sea water)/$m^3$ (filtrate). Specific energy consumption is $1.11{\times}10$ power of $-1kWh/m^3$ (filtrate). The indicators evaluated over the cycles with conventional (non-chemical) backwashing were compared with the cycles accompanied by CEB. A positive impact of CEB on performance indicators was demonstrated namely: normalized UF resistance remains unchanged within the regime accompanied by CEB, whereas the lack of CEB results in 30% of its growth. Those quantitative indicators can be incorporated into the target function for solving different optimization problems. They can be used in the software for optimisation of operating regimes or in the synthesis of optimal flow- diagram. The cycle characteristics, process parameters and water quality data are attached.

MF Membrane Application for Water Treatment in Japan

  • Okazaki, Minoru
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1995년도 추계 총회 및 학술발표회
    • /
    • pp.80-93
    • /
    • 1995
  • Membrane Technology, which has been in use for over twenty five years, has established itself as one of the principle separation methods. With improved technology, Reverse Osmosis ("RO") has been applied to large volume water treatment facilities. UF and MF Membrane Technology has, up until recently, been applied to small scale water treatment facilities. The fouling of membrane has restricted the growth of Membrane Technology in Water Treatment. Membrane fouling compound found in water causes the loss of flux across the membrane by absorbing to membrane and plugging their pores. Various methods have been used in the reduction and prevention of membrane fouling. For RO, a conventional pre-treatment system removes the pollutants, preventing the function decline of RO membrane by keeping SDI < 4 as the standard condition of feed water. UF and MF Membrane Technology that must have pre-treatment function within itself, are required to keep its ability not to be influenced by fouling.y fouling.

  • PDF

응집 플록 성장률 측정기를 이용한 멤브레인 공정의 전처리 응집공정 평가 (Evaluations of Coagulation Process for Membrane Pre-treatment using Floc Growth Rate Analyzer)

  • 손희종;김상구;김도환;강소원;최영익
    • 한국환경과학회지
    • /
    • 제25권2호
    • /
    • pp.231-238
    • /
    • 2016
  • In this study, we have investigated to find optimal pre-treatment flocculation condition by analyzing the floc growth rate with mixing conditions and the membrane permeation flux for pre-treatment step of the membrane process. The higher mixing intensity showed a constant floc size index (FSI) values, and lower mixing intensity increased the degree of dispersion of the FSI values. Results of comparing the distribution characteristics of the FSI value and the permeation flux were more effective in increasing flux when the FSI values were 0.2 or higher. The degree of dispersion of FSI was relatively large in 40 rpm mixing condition compared to 120 rpm. In 40 rpm mixing condition, it decreased the permeation flux compared to 120 rpm because various sizes of flocs were distributed. Coagulation-UF membrane process enhanced 30%~40% of the flux rate compare to UF alone process, and the coagulation-MF process increased up to 5% of the flux rate compare to MF alone process. Pre-treatment, that is, coagulation process, has been found to be less effects on relatively larger pore size for MF membrane. For UF membrane, the flux was a little bit same when applying only the rapid mixing process or rapid mixing with slow mixing processes together. In case of MF membrane, the flux was improved when rapid mixing process applied with slow mixing process together.

간척지, 해안가 근처의 농업용수 공급을 위한 기수담수 시스템 연구

  • 홍민
    • 한국농공학회지
    • /
    • 제57권4호
    • /
    • pp.16-24
    • /
    • 2015
  • Desalination technology is a process to remove salt from water. There are three classified In accordance with the concentration of salt The concentration of sea water 15,000~50,000mg/l, brackish water 1,500~15,000mg/l, desalination less than 500mg/l.. In general, salt to remove for using a pre-treatment UF filter, but this study is new pre-treatment technology RO Membrane process technology Suspended particulate matter is said most were treated at the pre-treatment equipment, wheat affluent particulate material was removed from the MF filter. Influent SS 16.2mg /l The treatment was effective in treatment 0.05mg /l of 99% is removed. COD is reduced to 60% in the pre-treatment device, after treatment was reduced to 30% RO membrane. Influent COD 10.2mg/l treatment was removed 1.9mg/l. The removal rate is 81.9%. Desalination removes the ionic substances in the RO Membrane. Influent EC $978.8{\mu}s/cm$ and treatment showed a result of $18.7{\mu}s/cm$.

UF와 디스크필터를 전처리시설로 이용한 역삼투압해수담수설비의 평가 (Evaluation of Seawater Reverse Osmosis Desalination System with UF and Disk Filter as Pre-Treatment)

  • 양근모;임동훈;김준하;정형호
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제1권1호
    • /
    • pp.59-68
    • /
    • 2013
  • 본 연구에서는 한외여과막과 역삼투압막으로 이루어진 해수담수화장치를 구성하였다. 해수를 취수하여 디스크필터와 한외여과막을 이용한 전처리설비를 통과시켜 생산한 전처리수의 $SDI_{15}$와 탁도를 측정하여 역삼투압해수담수설비에 적합함을 밝혔다. 역삼투압해수담수설비의 부산물인 브라인을 전처리수와 혼합하여 역삼투압해수담수설비의 입구농도를 변화시켰다. 농도 변화실험에서, 해수농도가 역삼투압해수담수설비의 성능에 끼치는 영향을 실험으로 구하였다. 염배제율, 회수율, 생산수의 수질은 입구농도에 따라 많은 변화가 있었으며, 에너지소비량도 입구농도에 거의 선형적으로 상승하는 것을 실험으로 구하였다.