• 제목/요약/키워드: U-shaped pipe

검색결과 15건 처리시간 0.016초

진공관식 태양열 집열 튜브의 열성능 비교 분석 (A Comparative Analysis on the Thermal Performance of Solar Vacuum Collector Tubes)

  • 현준호;천원기
    • 한국태양에너지학회 논문집
    • /
    • 제23권3호
    • /
    • pp.15-22
    • /
    • 2003
  • This study deals with the collection of solar energy and its storage in evacuated tubular collector systems for different types of header design, flow passage and heat transfer devices. In order to elicit the most efficient combination of header design, flow passage, heat transfer hardware and operating conditions, a series of tests were done for the four different types of solar collectors utilizing vacuum tubes. The systems studied here either has the evacuated collector tubes with a metal cap on one end or the all-glass evacuated solar collector tubes These evacuated tubular collectors are known to be more efficient than the flat-plate ones in both direct and diffuse solar radiation. Test results show that the system comprised of the all-glass evacuated tubes with U-shaped copper pipes inside outperforms the other configurations. Especially, a rolled copper sheet tightly placed along the inner surface of each inner tube enhances heat transfer between the heated collector surface and the water contained in the U-shaped copper pipe.

최초의 평가시험 방법을 고려한 수격흡수기의 장치에 관한 연구 (A Study on the Water Hammer Arrester Considering the Way of First Assessment Test)

  • 염문천;한용택
    • 한국화재소방학회논문지
    • /
    • 제29권1호
    • /
    • pp.53-59
    • /
    • 2015
  • 배관시스템의 불안정한 유동에 의해 생성되는 수격현상은 관내 압력의 과도한 변화, 진동 및 소음을 일으킬 수 있다. 이러한 수격현상은 관로, 펌프 및 밸브등의 시설물에 기계적인 사고를 유발시키는 원인이 되기도 한다. 한편, 국내에서는 수격현상으로 인한 피해를 최소화하기 위하여 수격흡수기를 제조 및 사용하여 왔으며, 그동안 별도의 기준이 없어 저가 위주로 생산 및 설치되어 왔다. 따라서, 본 연구에서는 수격흡수기 성능에 대한 최소 가이드라인을 제시하기 위하여, 하나의 배관으로 검증 가능한 시험방법, 수계소화설비에서 수격발생을 가정한 시험방법, 개방충격압과 차단충격압으로 구분한 흡수시험 방법, 배관을 분기한 시험시설 구성 방법 등의 다양한 방법들을 통하여 수격흡수기의 성능을 기준화 할 수 있는 방법등에 대하여 고안하였다. 그리고, 최종적으로는 U자형 배관과 시험용 추를 이용한 간단한 기계적 방식으로 수격흡수기의 수격압 흡수성능을 검증할 수 있는 실험 장치를 최초로 고안하여, 소방용 수격흡수기의 인정기준이 제정되었다.

Low-frequency modes in the fluid-structure interaction of a U-tube model for the steam generator in a PWR

  • Zhang, Hao;Chang, Se-Myong;Kang, Soong-Hyun
    • Nuclear Engineering and Technology
    • /
    • 제51권4호
    • /
    • pp.1008-1016
    • /
    • 2019
  • In the SG (steam generator) of PWR (pressurized water reactor) for a nuclear plant, hundreds of U-shaped tubes are used for the heat exchanger system. They interact with primary pressurized cooling water flow, generating flow-induced vibration in the secondary flow region. A simplified U-tube model is proposed in this study to apply for experiment and its counterpart computation. Using the commercial code, ANSYS-CFX, we first verified the Moody chart, comparing the straight pipe theory with the results derived from CFD (computational fluid dynamics) analysis. Considering the virtual mass of fluid, we computed the major modes with the low natural frequencies through the comparison with impact hammer test, and then investigated the effect of pump flow in the frequency domain using FFT (fast Fourier transform) analysis of the experimental data. Using two-way fluid-structure interaction module in the CFD code, we studied the influence on mean flow rate to generate the displacement data. A feasible CFD method has been setup in this research that could be applied potentially in the field of nuclear thermal-hydraulics.

소형 코리올리 질량 유량계의 개발 (Development of Small Size Coriolis Mass Flowmeter)

  • 임기원;지정근
    • 대한기계학회논문집B
    • /
    • 제30권6호
    • /
    • pp.497-504
    • /
    • 2006
  • A Coriolis mass flowmeter(CMF), which has U-Shaped unique measurins tube was developed fo. direct mass flow measurement. In order to convert the time difference between two measuring tubes motion into mass flowrate and flow quantity, a signal processing circuit, as a part of CMF, was also developed. The CMF was designed as the 15 mm nominal diameter of pipe connection and the 8 mm stainless steel(sus 316) pipe was used for measuring tube. To maximize the flow signal(time difference) from the measuring tubes, the natural frequency of measuring tube was adjusted as 220 Hz, which is same as the frequency of exciter. The maximum displacement at the end of the measuring tube was measured as 0.05 mm and the maximum time difference between two measuring tubes was observed as $20{\mu}s$, which was proper for discrimination and measuring range of CMF. The developed CMF was tested against the gravimetric flowmeter calibrator in the range of 3 kg/min and 30 kg/min. The results showed that the CMF has good linearity and repeatability in the tested flow range. Large size of CMF base on the current study experience will be developed.

V형 그루브윅을 갖는 소형 히트파이프의 작동특성 (Operational Characteristics for a Miniature Heat Pipe with a V-shaped Groove Wick)

  • 강환국;김철주;홍성은
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1999년도 춘계 학술발표회 논문집
    • /
    • pp.197-205
    • /
    • 1999
  • 소형 히트파이프에서 ?을 구리망사 또는 그루브를 적용할 수 있고 그루브 형상은 U, V 등 다양하다. 망사?은 모세압이 큰 잇점이 있어나 제작 단가가 높다. 그루브?은 대량생산이 용이하나 전밀 가공 기술이 요구된다. 현재까지 국내에서는 노트북 PC의 CPU 냉각에 사용한 소형 히트파이프의 전량을 해외에서 구매하고 있다. 본 연구에서는 직경 7 mm U형 그루브 관을 인발하여 관직경을 축소한 결과 내경 3.6 mm의 외경 4mm 의 V형 그루브관을 얻을 수 있었다. 이 관을 이용하여 소형 히트파이프를 제작하고 열전달 성능 시험을 수행하였다. 열전달 한계는 40~6$0^{\circ}C$ 범위작동온도 경사각 0$^{\circ}$ 에서 3 W를 얻을 수 있었다. U형 그루브 히트파이프에 비하여 모세압 저하로 인하여 낮은 값을 나타내었다. 열저항을 약 0.7~l.3 $^{\circ}C$/W 로 U형 그루브와 유사하였다.

  • PDF