• Title/Summary/Keyword: Typical Solar Radiation Data

Search Result 30, Processing Time 0.019 seconds

Characterization of Ozone Distributions in Pohang: Measurement Data during 2002~2006 (포항지역 오존농도의 분포 특성: 2002~2006년 측정자료)

  • Lim, Ho-Jin;Lee, Yong-Jik
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.1
    • /
    • pp.50-62
    • /
    • 2011
  • Temporal trends and spatial distributions of ozone concentrations in Pohang were investigated using data measured at 4 air quality monitoring stations (i.e., Daedo, Jukdo, Jangheung, and Desong) during 2002-2006. The monthly mean ozone concentrations were highest during April and June and decreased during July and August, which follows the typical trend in the Northeast Asia region. The high springtime ozone concentration might have been strongly influenced by the enhanced photochemical ozone production of accumulated precursors during the winter under increased solar radiations. In July and August, ozone levels were decreased by frequent and severe precipitation that caused lower mean monthly solar radiation and efficient wash-out of ozone precursors. This suggests that precipitation is extremely beneficial in the aspect of ozone pollution control. High ozone concentrations exceeding 80ppb dominantly occurred in May and June during the late afternoon between 16:00~17:00. Ozone concentrations were higher in Jangheung and Daesong relative to Daedo and Jukdo, whereas total oxidants $(O_3+NO_2)$ were higher in Jangheung and Daedo. In the suburban area of Daesong, ozone concentrations seem to be considerably higher than those in urban sites of Daedo and Jukdo due to lower ozone loss by NO titration with lower local NO level.

A Study on the Heat Transfer Improvement in the Exhaust-Section of Industrial Furnace (산업용로 배기부에서의 열전달 향상에 관한 연구)

  • Pak, Hi-Yong;Cha, Sang-Myung;Han, Chul-Hee
    • Solar Energy
    • /
    • v.12 no.3
    • /
    • pp.47-59
    • /
    • 1992
  • In the concentric tube type recuperator, which is the most typical type of radiation recuperator, installed on the exhaust-secion of industrial furnace, air flows between the adiabatic outer tube and the inner tube in which exhausted gas flows with high temperature. The waste heat of the exhausted gas is transferred to the inner tube, and transferred from the inner tube to the flowing air. The heat transfer by radiation In the concentric tube type recuperator is modeled using spherical harmonics approximation, namely, P-N method and numerically analyzed considering the effect of dynamic flow field. The results are compared with the existing empirical data. In addition, a theoretical method is presented for the analysis of the heat transfer characteristics of a recuperator with a reradiator installed in the inner tube, which causes re-radiant in the inner tube, and the characteristics of the recuperator is analyszed and defined.

  • PDF

The Effect of Meteorological Factors on Variation and Temporal and Spatial Characteristics of $NO_2$ Concentration in Pusan Area (부산광역시에서의 $NO_2$농도 특성 및 기상 영향인자 분석)

  • 이화운;김유근;장난심;이용희
    • Journal of Environmental Science International
    • /
    • v.8 no.4
    • /
    • pp.465-471
    • /
    • 1999
  • The concentration of air pollution in a large city such as Pusan has been increased every years due to the increase on fuel consumption at factories and by vehicles as well as the gravitation of the population. In this study, we have analyzed $NO_2$ concentration data and various data of meteorological factors during 1994-1997 to investigate the characteristics of $NO_2$ concentration and how the high $NO_2$ concentration is generated under the meterological condition. According to the study, $NO_2$ peak concentration at most sites occured about 1h later after the rush hour. In the characteristics of emissions in sites, sinpyeong-dong was highly contributed to point source while the other sites were highly contributed to line source. The high $NO_2$ concentration had high generation probability when temperature contained typical seasonal characteristics and wind speed was low. Using the relationship between meteorological factors and the daily average $NO_2$ concentration, correlation analysis was practiced. the seasonal variation of the daily average $NO_2$ concentration was correlated with air temperature, solar radiation and wind speed, but the correlation coefficient between meteorological factors and the daily average $NO_2$ concentration was not so much high. Thus we have known that the daily average $NO_2$ concentration is partially explained by meteorological factors.

  • PDF

Study on the Characteristics of Surface Ozone Distributions and the Ozone Critical Levels to Vegetation in the South Korea (남한 지역의 지면 오존 농도 특성과 식생에 대한 임계값 적용 연구)

  • Koo, Hae-Jung;Park, Soon-Ung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.3
    • /
    • pp.310-320
    • /
    • 2008
  • Concentration of tropospheric ozone ($O_3$) was investigated for the South Korea. And then the critical ozone levels, expressed as AOT40 (Accumulated exposure over a threshold of 40 ppb) to vegetation have been used in this region within the UNECE (United Nations Economic Commission for Europe) Convention on Long-Range Trans-boundary Air Pollution (CLRTAP). Hourly ozone concentration data from 1996 to 2001 at 26 air monitoring stations was used to estimate the exceedance of the critical levels. It was calculated for daylight hours for each station, and mapped using surface interpolation over the South Korea. The critical levels of ozone have shown the highly exceeded value in the Gyeonggi region, southern coastal region and central inland of the South Korea. It was some different from the typical ozone distribution which represented highly in the western inland and coastal regions. The area exceeding the critical level for crops was founded to be more than 40% of the whole South Korean territory. While that for trees was to be about 17% of the South Korea. The critical ozone critical level was based upon data from experiments on specific species, and thus may not be fully representative for all types of vegetation. Nevertheless, the critical level and its exceedance of the ozone concentration would be one of the useful tools for international agreements on abatement strategies to prevent ecosystem damage.

Simulation of Atmospheric Dispersion over the Yosu Area -II. Diurnal Variations by Solar Radiation- (여수지역 대기확산의 수치 모사 -II. 일사에 의한 일변화-)

  • 오현선;김영성
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.3
    • /
    • pp.225-236
    • /
    • 2000
  • Diurnal variations of wind field and pollutant dispersion over the Yosu area under the insolation conditions of summer and winter were investigated by using the Regional Atmospheric Modeling System (RAMS). Initially, horizontally homogeneous wind field were assumed on the basis of sounding data at the Kwangju upper-air station for days whose morning wind speeds were below 2m/s. In these days, the sea breeze prevailed in summer while the land breeze lasted for a few hours in the morning; the effect of synoptic winds was strong in winter with some inclusion of wind variations owing to the interaction between sea and land. The predicted wind direction at the location of the Yosu weather station captured an important change of the sea-land breeze of the observed one. The predicted wind speed and the air temperature agreed with observed ones in a reasonable range. In the morning, both in summer and winter, winds around the source location were diverged and became weak between the mountainous area to the southeast and the Kwangyang Bay to the north. Winds, however, accelerated while blowing to the east and south and blowing on the mountainous area. Complicated wind fields resulted in high pollutant concentrations at almost all receptors considered. These high concentrations in the morning were even comparable to the ISCST3 calculations with the worst-case and typical meteorological conditions designated by USEPA(1996). On the other hand, in the afternoon, the wind field was rather uniform even in the mountainous area with development of mixing layer and the concentration distributions being close to the Gaussian distributions.

  • PDF

A Case Study of Tsukuba Tornado in Japan on 6 May 2012

  • Choo, Seonhee;Min, Ki-Hong;Kim, Kyung-Eak;Lee, Gyuwon
    • Journal of the Korean earth science society
    • /
    • v.39 no.5
    • /
    • pp.403-418
    • /
    • 2018
  • This study conducted synoptic and mesoscale analyses to understand the cause of Japan Tsukuba tornado development, which occurred at 0340 UTC 6 May 2012. Prior to the tornado occurrence, there was a circular jet stream over Japan, and the surface was moist due to overnight precipitation. The circular jet stream brought cold and dry air to the upper-level atmosphere which let strong solar radiation heat the ground with clearing of sky cover. A tornadic supercell developed in the area of potentially unstable atmosphere. Sounding data at Tateno showed a capping inversion at 900 hPa at 0000 UTC 6 May. Strong insolation in early morning hours and removal of the inversion instigated vigorous updraft with rotation due to vertical shear in the upper-level atmosphere. This caused multiple tornadoes to occur from 0220 to 0340 UTC 6 May 2012. When comparing Tateno's climatological temperature and dew-point temperature profile on the day of event, the mid-level atmosphere was moister than typical sounding in the region. This study showed that tornado development in Tsukuba was caused by a combination of (a) topography and potential vorticity anomaly, which increased vorticity over the Kanto Plain; (b) vertical shear, which produced horizontal vortex line; and c) thermal instability, which triggered supercell and tilted the vortex line in the vertical.

A Model Study on Development of Animal Wastes Treatment System for a Full-time Farm Household Raising Livestock (전업양축농가의 축분뇨처리시스템 개발을 위한 모형실험)

  • 최홍림;김현태;정영륜
    • Journal of Bio-Environment Control
    • /
    • v.2 no.1
    • /
    • pp.16-26
    • /
    • 1993
  • A sundry system is one of popular systems for composting livestock manure, of which main honest is to utilize unlimited, clean, and free solar radiation. A sundry system with a composter of two horizontal screw-type concrete ducts at different height, was constructed and operated for three days for each test in May, 1993, to evaluate its composting performance. Four treatments of the mixture ratio of swine manure and saw dust (manure : sawdust= 1 : 1.25, 1 : 1, 1 : 0.7, 1 : 0.5) were implemented to evaluate the effect of the mixture ratio on degradation of the composting materials of a sundry system with a screw-type composter. Maximum temperature of the composting materials was over 5$0^{\circ}C$ at D1 or D2 (one or two days after operation starts) for each test. Mean C/N ratio and water contents of the materials were reduced by more than 15 and 20%, respectively. Microbial density of each test showed a typical variation with the lapse of the composting time. Mesophilic microorganism seemed to play more important role on degradation of the materials than thermophilic. A sundry system with a screw-type composter can be considered as a feasible system on basis of maturity data. The conclusion was completely reverse from that of Choi et at., although both adopted a sundry system. A further study is recommended to pursue the cause of better performance of the screw-type composter, whether it was due to affirmative weather or more efficient composter.

  • PDF

Air Temperature Profile within a Partially Developed Paddy Rice Canopy (생육중기 벼 군락 내 기온의 연직구조)

  • Yoon Young-Kwan;Yun Jin-Il;Kim Kyu-Rang;Park Eun-Woo;Hwan Heon;Cho Seong-In
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.2 no.4
    • /
    • pp.204-208
    • /
    • 2000
  • Little information is available for the temporal variation in air temperature profile within rice canopies under development, while much works have been done for a fully developed canopy. Fine wire thermocouples of 0.003 mm diameter (chromel-constantan) were installed at 10 vertical heights by a 10 cm step in a paddy rice field to monitor the air temperatures over and within the developing rice canopy from one month after transplanting (June 29) to just before heading (August 24). According to a preliminary analysis of the data, we found neither the daytime temperature maximum nor the night time minimum at the active radiation surface (the canopy height with maximum leafages) during this period, which is a typical profile of a fully developed canopy. Air temperature within the canopy never exceeded that above the canopy at 1.5 m height during the daytime. Temporal march of the within-canopy profile seemed to be controlled mainly by the ambient temperature above the canopy and the water temperature beneath the canopy, and to some extent by the solar altitude, resulting in alternating isothermal and inversion structures.

  • PDF

Growth Performances of Seedlings of Daphniphyllum macropodum in Naejang National Park for Container Seeding Production (시설양묘에 적용을 위한 내장산 굴거리 나무 군락내 치수의 생장 특성)

  • Chung, Jin-Chul;Jeong, Ji-Young;Choi, Jeong-Ho;Jeon, Kyung-Soo;Bae, Jong-Hyang
    • Journal of Bio-Environment Control
    • /
    • v.20 no.4
    • /
    • pp.365-372
    • /
    • 2011
  • This study aimed to examine foundational data for container seedling production with the subject of Daphniphyllum macropodum community in Mt. Naejang National Park. To achieve the goal, it investigated the growth characteristics of young tree seedlings growing in places with different light intensity environment. Regarding the growth environment of Daphniphyllum macropodum community, it was typical heavy rain summer climate, and the soil was silt loam with the organic content as 11.42~15.61%, total nitrogen as 0.50~0.76%, cation exchangeable capacity (C.E.C) as 18.92~23.32 cmol/kg, and pH as 4.85~5.58. About light intensity environment changed by research plots, relative transmittance of solar radiation was 71~76% in plot A, 37~42% in plot B, 65~70% in plot C, and 28~33% in plot D. The seedlings tended to be intensively distributed either under the crown of their mother tree or in the slope site, and plot A and C where light intensity environment is relatively more favorable showed 1,550 tree/ha and 1,250 tree/ha. Total biomass production of Daphniphyllum macropodum seedlings was 5.37 g in plot A and 5.29 g in plot C, so they were higher than 4.42~4.51 g in plot B and D with relatively less favorable light intensity environment. The T/R ratio was 1~2, leaf area rate was $139.71{\sim}183.50cm^2{\cdot}g^{-1}$, leaf area ratio was $39.68{\sim}60.66cm^2{\cdot}g^{-1}$, and leaf dry weight ratio grew higher in the range of $0.28{\sim}0.33cm^2{\cdot}g^{-1}$ as the intensity of radiation became less. It is thought that in the generation and growth of Daphniphyllum macropodum seedlings, the intensity of light has more effects than the organic content in soil. And it is also thought that in the application of container seedlings production, light environment management over 65~70% to full sun light intensity will affect significantly the initial growth of Daphniphyllum macropodum.

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF