• 제목/요약/키워드: Type of Outlet

검색결과 438건 처리시간 0.024초

스마트 홈에서 Zigbee 기반의 대기전력 제어 연구 (A Study of Standby Power Control Based on Zigbee in Smart Home)

  • 이성준;김도현
    • 한국멀티미디어학회논문지
    • /
    • 제17권7호
    • /
    • pp.879-885
    • /
    • 2014
  • This paper designs and implements the 2 plug type standby power control outlet based on IEEE 802.15.4 using Zigbee and IPv6 network in order to reduce the standby power to the user. The standby power control system is consisted of direct power and standby power plug. Also this system can communicate bidirectionally in wireless because built-in wireless communication modules. One gateway is linked with many standby power control outlet in wireless. Each standby power control outlet executes the operation needed in power control independently. Also each standby power control outlet has its own power can be detected in real time independently of the power can be controlled.

미소 T 채널의 혼합 특성에 관한 연구 (Study on mixing characteristics of T-type micro channel)

  • 이상현;안철오;서인수;이상환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2495-2500
    • /
    • 2008
  • We simulated the mixing characteristics in micro T-channel using Lattice Boltzmann Method. We studied the relation a mixing length and pressure-drop due to inlet and outlet ration in Reynolds number 0.5, Peclet number 500 and Schmidt 1000. The ratio of a down-inlet to up-inlet was $0.5{\sim}1.5$ times, up-inlet to outlet was $1{\sim}3$ times and outlet length was 250 times to up-inlet. The mixing length decrease linearly as outlet ratio decreased, and pressure-drip increase non-linearly. Initial stage of micro channel mixture was fast by down-inlet ratio, however, the mixing length is not influence.

  • PDF

삼중효용 흡수사이클의 성능특성 평가 (evaluation of Performance Characteristic on Triple Effect Absorption Cycle)

  • 권오경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권6호
    • /
    • pp.782-791
    • /
    • 1998
  • This paper presents a computer simulation of five types of triple effect absorption cycles employ-ing the refrigerant absorbent combinations of NH3/LiNO3 low-pressure type NH3/LiNO3+H2O/LiBr binary two-stage type series flow cycle and two types of parallel flow cycle for H2O/LiBr. The absorption systems is investigated through cycle simulation to obtain the system characteristics with the cooling water inlet temperature approach temperature of absorber loss temperature of absorber and chilled water outlet temperature. The most important characteristic temperature of absorber and chilled water outlet temperature. The most important characteristic of NH3/LiNO3 low-pressure type and a NH3/LINO3+H2O/LiBr binary two-stage type is that it obtains a coefficient of performance higher than the sum of the performance coefficients of its part operating independently. As a result of this analysis the optimum designs and operating conditions were determined based on the operating conditions and the coefficient of performance.

  • PDF

Cone Type 밸브 내부유동 수치해석에 관한 연구 (A Study on the Numerical Analysis of Internal Flow in a Cone Type Valve)

  • 진도훈
    • 한국산업융합학회 논문집
    • /
    • 제23권2_2호
    • /
    • pp.199-207
    • /
    • 2020
  • These days, many different types of valves are developed in the industrial area according to their use purpose. Multiple kinds of valves are installed to control a flow and pressure of the pipe conveying fluid. Valves serve as critical roles in land plants such as power plants. The performance of equipment varies depending on valve characteristics. In this study, the internal flow analysis on Cone-type valve is conducted to analyze flow field and secure a value of the flow coefficient Cv. According to the internal flow analysis, when the flow distribution of the middle cross-section of valve was open 100%, flow field was relatively and smoothly taken out. If it was open 50%, flow recirculation region increased and a little complex flow field occurred. Unlike ball valve or butterfly valve, this valve had flow recirculation in its outlet depending on a valve opening amount. Therefore, it was found that there was no flow recirculation in the outlet of Cone-type valve.

Development of Evaluation of the Locally Made Propeller Type Mistblower

  • Kwangwaropas, Mongkol;Onkong, Narong
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.488-499
    • /
    • 1996
  • A propeller type mistblower was designed and manufactured. The machine consisted of a 770 millimeters diameter propeller driven by the power take off of a tractor. It delivered 26,400 cubic meters of air per hour and has the outlet speed about 180 kilometers per hour. Spray liquid was injected at 30 bars pressure through hollow cone type nozzles which were located around the air outlet of the machine bya poston type pump. Power consumption of the machine was found to be 12.46 kilowatts and the effective forward travel speed was about 2.7 kilometers per hour. Upon spraying mango trees, it was shown that the density of spray partices was about 100 microns and consumed 3.12 liters per tree. Working speed in 6 meters row spacing mango orchard was about one hectare per hour.

  • PDF

PID 제어를 이용한 멀티형 열펌프의 용량조절 (Capacity Modulation of a Multi-Type Heat Pump System Using PID Control)

  • 정대성;김민성;김민수;이원용
    • 설비공학논문집
    • /
    • 제12권5호
    • /
    • pp.446-475
    • /
    • 2000
  • Performance of a water-to-water multi-type heat pump system using R22 has been experimentally investigated. Total refrigerant flow rate was adjusted with a variable speed compressor and the refrigerant flow rate for two indoor units were controlled by electronic expansion valves. Evaporator outlet pressure of refrigerant and indoor unit outlet temperatures of secondary fluid were selected as controlled variables. Experiments were carried out for both cooling and heating modes using PID control method. Results show that the multi-type heat pump system can be adequately controlled by keeping control gains at certain levels for various operating conditions.

  • PDF

인공지반을 적용한 사교하는 사면에서의 터널 갱구부 설계 (The design of outlet in inter-cross slope with tunnel which it applied forming artificial ground)

  • 박철숙;곽한;이규탁;김봉재;윤용진;김희광
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1532-1548
    • /
    • 2008
  • The tunnel type spillways is under construction to increasing water reservoir capacity in Dae-am dam. The tunnel outlet was planned to be made after installing slope stabilization system on natural slope there. Generally, the tunnel outlet is made perpendicularly to the slope, but in this case, it had to be made obliquely to the slope for not interrupting flow of river. Because of excavation in condition of natural slope caused to deflecting earth pressure, the outlet couldn't be made. So, artificial ground made with concrete that it was constructed in the outside of tunnel for producing the arching effect which enables to make a outlet. We were planned tunnel excavation was carried out after artificial ground made. Artificial ground made by poor mix concrete of which it was planned that the thickness was at least 3.0m height from outside of tunnel lining and 30cm of height per pouring. Spreading and compaction was planned utilized weight of 15 ton roller machine. In order to access of working truck, slope of artificial ground was designed 1:1.0 and applied 2% slope in upper pert of it for easily drainage of water. In addition to, upper pert of artificial ground was covered with soil, because of impaction of rock fall from upper slope was made minimum. The tunnel excavation of the artificial ground was designed application with special blasting method that it was Super Wedge and control blasting utilized with pre-percussion hole.

  • PDF

십자형심장에 동반된 양대혈관우심실기시증 -수술치험 1례 (Double Outlet of Right Ventricle in Criss-Cross Heart -Surgical Experience of One Case)

  • 김대연;조성래;박성달;정현기
    • Journal of Chest Surgery
    • /
    • 제30권12호
    • /
    • pp.1242-1246
    • /
    • 1997
  • Criss-cross heart which is a cardiac malformation caused by abnormal rotation of the ventricles early in embryonic development, is rare but a double outlet of right ventricle in priss-cross heart is very rare. We experienced a case of criss-cross heart which is situs solidus, concordant atrioventricular connection and double outlet of rig t ventricle with remote ventricular septal defect of perimembranous inlet type. A 4-years old female was diagnosed as a double outlet of right ventricle in criss-cross heart after echocardiography, cardiac catheterization and cardiac angiography. The surgical correction was a intraventricular reconstruction of left ventricular outflow with 314 circle of 20 mm Hemashield vascular graft from the ventricular septal defect to the aorta. The patient had a temporary atrioventricular block but was recovered uneventfully, and a postoperative echocardiogram showed no left ventricular outflow obstruction, no intracardiac shunt.

  • PDF

Numerical Simulation on the Performance of Axial Vane Type Gas-Liquid Separator with Different Guide Vane Structure

  • Yang, Fan;Liu, Ailan;Guo, Xueyan
    • International Journal of Fluid Machinery and Systems
    • /
    • 제10권1호
    • /
    • pp.86-98
    • /
    • 2017
  • In order to obtain high efficiency and low resistance droplet separation apparatus, axial vane type gas-liquid separators with different guide vanes were designed, and the RNG $k-{\varepsilon}$ model as well as discrete phase model (DPM) were used to investigate the flow pattern inside the separators. It was shown that the tangential velocity distribution under different guide vanes have Rankine vortex characteristics, pressure distribution exhibits a high similarity which value becomes big as the increase of the blade outlet angle and the decrease of the guide vane numbers. The increase of the guide vane numbers and the decrease of the blade outlet angle could make separation improve significantly. The separation efficiency is almost 100% when the droplet diameter is bigger than $40{\mu}m$.

퍼지 로직 적용 PID 제어를 이용한 멀티형 열펌프의 용량조절 (Capacity Modulation of a Multi-Type Heat Pump System using PID Control with Fuzzy Logic)

  • 김세영;김민수
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.810-817
    • /
    • 2001
  • Performance of a water-to-water multi-type heat pump system using R22 which has tow indoor units has been investigated experimentally. The refrigerant flow rate of each indoor unit was regulated by an electronic expansion valve and the total refrigerant flow rate of the system was controlled by a variable speed compressor. In the system, evaporator outlet pressure of refrigerant and outlet temperatures of secondary fluid from indoor units were selected as control variables. Experiments were executed for both cooling and heating modes using PID control method with fuzzy logic, and results of the test are compared with a classical PID method. In the case of PID control with fuzzy logic, the fuzzy control rules corrects PID parameters each time. Results show that PID control with fuzzy logic has the merits of quick response and reduced overshoot.

  • PDF