• Title/Summary/Keyword: Type I diamond

Search Result 27, Processing Time 0.029 seconds

A study on Synthesis and Radiation Detector Fabrication of Thin Films by MW Plasma CVD (MWPECVD에 의한 박막의 합성과 방사선 검출 특성에 관한 연구)

  • Koo, Hyo-Geun;Lee, Duck-Kyu;Song, Jae-Heung;Noh, Kyung-Suk;Park, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.27 no.2
    • /
    • pp.45-50
    • /
    • 2004
  • Synthesis diamond films have been deposited on the molybdenum substrates using an microwave plasma enhanced chemical vapor deposition method. The effects of deposition time, surface morphology, infrared transmittance and Raman scattering have been studied. Diamond deposited on molybdenum substrate for 100 hours by MW plasma CVD from $CH_4-H_2-O_2$ gas mixture had good crystallity with $100[{\mu}m]$ thickness needed for radiation detector. Diamond radiation detector of M-I-M type was made and the current of radiation detector was increased by increasing X-ray dose.

  • PDF

Micropore Analysis and Adsorption Characteristics of Activated Carbon Fibers (활성탄소섬유의 미세기공 분석 및 흡착특성)

  • Moon, Dong-Cheul;Lee, Kwang-Ho;Kim, Chang-Soo;Kim, Do-Hyung;Kim, Mi-Ran;Shin, Chae-Ho;Park, II-Young;Nam, Seoung-Youl;Lee, Chang-Gi
    • Analytical Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.89-95
    • /
    • 2000
  • Three grades of activated carbon fibers (ACFs) were prepared from various precursors of plantic, synthetic, and mixed fabrics of viscose rayon and cotton. The ACFs an exhibited type I isotherms on the adsorption of nitrogen or argon. Micropore analysis revealed that the ACFs have uniform micropore size distribution in which their peak diameters were in the range of $5.6{\pm}0.3{\AA}$. The BET surface area of ACFs up to $1600m^2g^{-1}$ was proportional to the adsorption capacity of iodine. The BET values of the ACFs prepared were proportional to the burn-off degree of the products.

  • PDF

Ultra Precision Machining Characteristics of PMMA in HMD optical system (HMD 광학계용 PMMA의 초정밀 가공 특성)

  • Yang J.S.;Kim G.H.;Yang S.C.;Lee I.J.;Kim M.S.;Lee D.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1566-1570
    • /
    • 2005
  • The aspherical lenses are used as optical lens of HMD optical system. The optimum cutting condition of PMMA lens sample with ultra precision SPDT, the diamond tool nose radius, the cutting speed, the feed rate, the depth of cut, and cutting fluid type are found. The demanded surface roughness 10 nm Ra, aspherical form error $1.0\;\mu{m}$ P-V for aspherical lens of optical data storage device are satisfied.

  • PDF

THE MARGINAL SEALING EFFECT OF COMPOSITE RESIN INLAYS ACCORDING TO THE LUTING TECHNIQUES (합착방법(合着方法)에 따른 복합(複合)레진 인레이의 변연폐쇄효과(邊緣閉鎖效果))

  • Moon, Young-Deok;Cho, Kyeu-Zeung
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.1
    • /
    • pp.121-132
    • /
    • 1991
  • The purpose of the study was to evaluate the marginal sealing effect of composite resin inlays according to the luting techniques and compare them to the conventional direct resin filling technique. 90 cavities of class V were prepared on the buccal surface of 90 extracted molar teeth, which were divided into four groups. Cavities of control group were directly filled with Scotchbond 2 and P - 50, and those of composite resin inlay groups were luted with one of the followings: Adhesive bond followed by Adhesive cement, All bond followed by Adhesive cement, Fuji - ionomer type L All the specimens were immersed in India ink dye solution for 7 days at $37^{\circ}C$ incubator after thermocycling between $5^{\circ}C$ and $60^{\circ}C$ and longitudinally sectioned with diamond disk inot two parts All the specimens were observed at the occlusal and gingival margins and statistical analysis was performed. The results were as follows: 1. Groups filled with composite resin inlay showed less marginal leakage than the group directly filled(p<0.01). 2. There was no significant difference in marginal leakage between composite resin inlay groups luted with Adhesive bond followed by Adhesive cement and the group luted with All bond followed by Adhesive cement(p>0.05). 3. At occlusal margins, Composite resin inlay group luted with Adhesive bond followed by Adhesive cement showed less marginal leakage than the group luted with Fuii ionomer type I(p<0.01). At gingival margins, composite resin inlay group luted with All bond followed by Adhesive cement showed less marignal leakage than the group luted with Fuji ionomer type I(P<0.01).

  • PDF

Surface Hardness Measurement of Anodic Oxide Films on AA2024 based an Ink-Impregnation Method

  • Moon, Sungmo;Rha, Jong-joo
    • Journal of the Korean institute of surface engineering
    • /
    • v.53 no.2
    • /
    • pp.80-86
    • /
    • 2020
  • This paper is concerned with type of imperfections present within the anodic oxide films on AA2024 and surface hardness of the anodic film measured after ink-impregnation. The anodic oxide films were formed for 25 min at 40 mA/㎠ and 15±0.5℃ and 300 rpm of magnet stirring rate in 20% sulfuric acid solution. The ink-impregnation allows clear observations of not only the imperfections within the anodic oxide films but also an indentation mark on the oxide film surface made by a pyramidal-diamond penetrator for the hardness measurement. There were observed four different regions in the anodic oxide films on AA2024 and the surface hardness of the anodic oxide films appeared to be crucially dependent on the type of defects, showing 60~100 Hv on the oxide surface region I with large size black defect, 100~140 Hv on the oxide surface region II with large size grey defect, 140~170 Hv on the oxide surface region III with mall size black and/or grey defects and 170~190 Hv on the oxide surface region IV without defects. The pyramidal indentation marks were observed to be distorted in the regions with a large size black and grey defects, while no distortion of the indentation mark was observed in the regions with small size defects and without visible defects.

AN EXPERIMENTAL STUDY ON THE MICROHARDNESS OF DENTAL AMALGAMS (치과용 아말감의 미세경도에 관한 실험적연구)

  • Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.8 no.1
    • /
    • pp.89-96
    • /
    • 1982
  • The purpose of this study is to identify the phases of four different types, low-copper lathe cut (Type II, class 1) and spherical (Type II, class 2) amalgam alloys which are made by Caulk company and high copper Dispersalloy (Type II, class 3) made by Johnson & Johnson and Tytin (Type I, class 2) made by S.S. White and to determine the Vickers hardness number on the individual phase and four different types of dental amalgam. After each amalgam alloy and Hg measured exactly by the balance was triturated by the mechanical amalgamator (De Trey), the triturated mass was inserted into the cylindrical metal mold which was 4 mm in diameter and 12mm in height and was pressed by the Instron Universal Testing machine (Model 1125) at the speed of 1mm/minute with 143$kg/cm^2$ according to the A.D.A. Specification No. 1. The Specimen removed from the mold, mounted and stored in the room temperature for 7 days. The speciman was polished with the emery paper from #220 to #1200 and finally on the polishing cloth with 0.3 and 0.05 um $Al_2O_3$ powder suspended in water. And then each specimen was etched by Allan's method and washed with Sodium Bisulfinite for 30 seconds. Finally differentiation and metallography on each phase were obtained by using metallographical microscope (Versamet, Union) and microhardness was obtained by using microhardness tester (MVH-2, Torsee). The results were as follows: 1. In the low-copper amalgam, the ${\gamma}$, ${\gamma}_1$ and ${\gamma}_2$ phase were observed and in the high-copper amalgam, the ${\gamma}$, ${\gamma}_1$. ${\epsilon}$ and ${\eta}$ phases were observed but ${\gamma}_2$ phase was not observed. 2. Among the microhardness of each amalgam phase measured under pressing a vickers diamond indenter with 2.0gm load for 30 seconds, e phase has the highest V.H.N (314 ${\pm}$ 20), and in low-copper amalgam 12 phase has the lowest V.H.N. (29${\pm}$1) and ${\eta}$ phase which was observed in high-copper amalgam has 230${\pm}$13 V.H.N and this phase is considerd to contribute to strengthen the handness in amalgam. 3. The V.H.N. measured under pressing a Vickers diamond indenter with 300.0gm load for 30 seconds in low-copper amalgam was lower than that of high-copper amalgam.

  • PDF

High Pressure Phase Transition Study of ${\alpha}$-cristobalite $GaPO_4$ (${\alpha}$-크리스토발라이트 구조의 $GaPO_4$에 대한 고압 상변이 연구)

  • Hwang, Gil-Chan;Kim, Young-Ho
    • Journal of the Mineralogical Society of Korea
    • /
    • v.23 no.3
    • /
    • pp.267-272
    • /
    • 2010
  • High pressure x-ray diffraction patterns of ${\alpha}$-cristobalite gallium phosphate ($GaPO_4$) were acquired up to 8.9 GPa at room temperature using Mao-Bell type diamond anvil cell with high flux synchrotron radiation. Starting orthorhombic phase (phase-I) shows the splitting of peak which is possibly resulted from the pressure induced orientation disorder of the framework structure of tetrahedra. This is designated as phase-I'. This phase transforms to the orthorhombic high pressure phase-III between 2 and 3 GPa. Present phase transition sequence is not in accord with the recent high pressure X-ray diffraction results performed on the same starting sample (Ming et al., 2007). X-ray pattern of the unloaded sample to ambient pressure shows that the structure retains that of the high pressure phase prior to decompression.

Structure Design of Fall Impact Protection Pad Using 3D Printing Technology and Comparison of Characteristics According to Filament Material (3D 프린팅 기술을 활용한 낙상충격 보호패드 구조설계 및 필라멘트 소재에 따른 특성 비교)

  • Park, Jung Hyun;Jung, Hee-Kyeong;Lee, Jeong Ran
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.5
    • /
    • pp.939-949
    • /
    • 2017
  • This study uses 3D printing technology to design and fabricate a fall impact protection pad with a spacer fabric structure. The design of the pads consists of hexagonal three-dimensional units connected in a honey-comb shape; in addition, the unit consists of a surface layer and a spacer layer. Protect pads were designed as either a hexagonal type or diamond type according to the surface layer structure; subsequently, a spacer filament was also designed as the most basic I-shape type. Designed pads were printed using four types of flexible filaments to select suitable material for a fall impact protection pad. Impact protection performance and bending stiffness were evaluated for the eight type of pad outputs. As a result of the impact protection performance evaluation, when the force of 6,500N was applied, the force passed through the pad was in the range of 1,370-2,132N. FlexSolid$^{(R)}$ and Skinflex$^{TM}$ showed good protection performance and cubicon flexible filament showed the lowest protection. NinjaFlex$^{(R)}$ was found to be the most flexible in the bending stiffness evaluation.

Gemological Characters and Jewelry Design of Fresh Water Pearl -Focused on Color Treated Cultured Pearl- (담수진주의 보석학적 특성과 진주주얼리 디자인 제안 -색처리된 양식 진주를 중심으로-)

  • Kim, Kyung-Jin;Kim, Hea-Yeon
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.11
    • /
    • pp.154-161
    • /
    • 2010
  • With Jewelry industry is becoming active with gradual increase of transactions of pearl and diamond. The pearl market of recent times the size of that market was magnified because the pearls of various type are imported. The necessity of new design development and grasps properties of pearl is demanded clearly because like that. This research analyzed the cultivated brown pearl and black pearl which is sold from market with gemological Analysis. As result, it is ascertained the dyed fresh water pearl. I suggest the design which uses the chocolate brown color pearl beads which the consumers prefer and another pearl design which is concept of wedding gift through CAD/CAM works.

A preliminary study on the surface finishing of a hard disk slider using magnetorheological (MR) fluid (자기유변유체를 이용한 하드디스크 슬라이더의 표면연마를 위한 기초연구)

  • Jung, B.S.;Jang, K..I.;Min, B..K.;Lee, S.J.;Seok, J.
    • Transactions of the Society of Information Storage Systems
    • /
    • v.3 no.2
    • /
    • pp.66-72
    • /
    • 2007
  • Surface finishing using magnetorheological (MR) fluid is useful to finish small but not too small workpieces such as those in a few millimeter scale. However, due to the high surface hardness, this finishing process does not seem to be suit for applying to a hard disk slider. In this work, a preliminary study is performed on the finishing of the hard disk slider surface with a mixture of an MR fluid and diamond powder. During a wheel type MR finishing process, centrifugal force is found to be a major factor to cause a reduction in material remove rate (MRR), which is supported by a theoretical model. To facilitate this founding, the rotational speed of tool is confined to 500rpm while a rectilinear alternating motion with the mean speed, which is equivalent to the rotational speed, is additionally applied to the workpieces. As a consequence, MRR of about 2 times of the sole rotational case is obtained. This paper shows that MR finishing process can be used to polish a hard material in millimeter scale efficiently by controlling the speeds of the tool and the workpiece.

  • PDF