• 제목/요약/키워드: Type 1, 2 Errors

검색결과 233건 처리시간 0.029초

LINKING EVALUATION OF SUBJECTIVE TIRE TESTS ON THE ROAD WITH OBJECTIVELY MEASURED DATA

  • Stumpf, H.W.
    • International Journal of Automotive Technology
    • /
    • 제2권1호
    • /
    • pp.17-23
    • /
    • 2001
  • Measurements of the initial values lead to an inverse and mathematically unprecisely formulated problem. A precise definition of an inverse problem is possible. It is to state a mathematical model of a physical process with clearly defined initial and exit values for the system behind the process. One can grasp the idea of an inverse problem by considering the tire as a copy of the objects of nature in a room with observations. Interpretation of nature is generally a result of an inverse problem. On one hand, the tire may be represented through the sensory organs and the nervous system as well as the experiences of the developer's existing apparatus of the projection of reality. On the other hand, it may be represented by a physical law or a model that can be confirmed or is to be refuted with the help of suitable measurements. During reconstruction of a measuring signal and the identification of a black box that can be assumed to be linear and causal, the tire becomes a first type Volterra integral equation of the convolution type. But measurements of the initial values are always fuzzy, the errors grow and the system behavior can no longer be forecasted. Thus, we have to deal with a chaotic system. This chaos produces fractals in a natural way. These are self-similar geometric structures. This self-similarity is clearly visible in the design.

  • PDF

상악 전치의 치열 형태에 따른 스캔 반복 측정 안정성 평가: in vitro 연구 (Evaluation of repeated measurement stability of dentition type of maxillary anterior tooth: an in vitro study)

  • 박동인;손호정;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제41권3호
    • /
    • pp.211-217
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate the repeated measurement stability of scans related to dentition type. Methods: A normal model and the crowding and diastema models are also duplicated using duplicating silicon. After that, a plaster model is made using a plaster-type plaster on the duplicate mold, and each model is scanned 5 times by using an extraoral scanner. The gingival part and molar part were deleted from the 3D STL file data obtained through scanning. Using the 3D stl file obtained in this way, data is nested between model groups. Thereafter, RMS values obtained were compared and evaluated. The normality test of the data was performed for the statistical application of repeated measurements with dentition type, and the normality was satisfied. Therefore, the one-way ANOVA test, which is a parametric statistical method, was applied, and post-tests were processed by the Scheffe method. Results: The average size of each RMS in the Normal, Diastema, and Crowding groups was Normal> Crowding> Diastema. However, the standard deviation was in the order of Crowding> Normal> Diastema. The average value of each data is as follows. Diastema model was the smallest ($5.51{\pm}0.55{\mu}m$), followed by the crowding model ($12.30{\pm}2.50{\mu}m$). The normal model showed the maximum error ($13.23{\pm}1.06{\mu}m$). Conclusion: There was a statistically significant difference in the repeatability of the scanning measurements according to the dentition type. Therefore, you should be more careful when scanning the normal intense or crowded dentition than scanning the interdental lining. However, this error value was within the range of applicable errors for all clinical cases.

Inbreeding Coefficients in Two Isolated Mongolian Populations - GENDISCAN Study

  • Sung, Joo-Hon;Lee, Mi-Kyeong;Seo, Jeong-Sun
    • Genomics & Informatics
    • /
    • 제6권1호
    • /
    • pp.14-17
    • /
    • 2008
  • GENDISCAN study (Gene Discovery for Complex traits in Asian population of Northeast area) was designed to incorporate methodologies which enhance the power to identify genetic variations underlying complex disorders. Use of population isolates as the target population is a unique feather of this study. However, population isolates may have hidden inbreeding structures which can affect the validity of the study. To understand how this issue may affect results of GENDISCAN, we estimated inbreeding coefficients in two study populations in Mongolia. We analyzed the status of Hardy-Weinberg Equilibrium (HWE), polymorphism information contents (PIC), heterozygosity, allelic diversity, and inbreeding coefficients, using 317 and 1,044 STR (short tandem repeat) markers in Orkhontuul and Dashbalbar populations. HWE assumptions were generally met in most markers (88.6% and 94.2% respectively), and single marker PIC ranged between 0.2 and 0.9. Inbreeding coefficients were estimated to be 0.0023 and 0.0021, which are small enough to assure that conventional genetic analysis would work without any specific modification. We concluded that the population isolates used in GENDISCAN study would not present significant inflation of type I errors from inbreeding effects in its gene discovery analysis.

Alignment System Development for producing OLED using Fourth-Generation Substrate

  • Park, Jae-Yong;Han, Seok-Yoon;Lee, Nam-Hoon;Choi, Jeong-Og;Shin, Ho-Seon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.873-878
    • /
    • 2008
  • Doosan Mecatec has developed alignment system for Organic Light-Emitting Diode (OLED) display production using large size substrate. In the present article, The alignment system between the substrate and the mask, which is a core technology for producing the OLED product using the fourth-generation substrate with $730{\times}920mm^2$ or more, will be described by dividing into a substrate loader, a magnet unit, a CCD camera, etc. The substrate loader is optimized through the simulation where the central portion of the substrate droops by about 1.5mm by clamping each of a long side (920mm direction) and a short side (730mm direction) thereof by 6 point and 4 point. A magnet unit using a sheet type of rubber magnet is constituted and a CCD camera model with the specifications capable of minimizing the errors between a clear image and the same image is selected. The system to which an upward evaporation technique of small molecular organic materials will be applied has been developed so that repeatability and position accuracy becomes ${\pm}1{\mu}m$ or less using an UVW type of stage. Also, the vision accuracy of the CCD camera becomes ${\pm}1{\mu}m$ or less and the align process TACT becomes 30sec. or less so that the final alignment accuracy between the substrate and the mask becomes ${\pm}3{\mu}m$ or less. In order to meet an extra-large glass substrate, an evaporation system using an extra-large AMOLED substrate has been developing through a vertical type of an alignment system.

  • PDF

취학전 아동의 굴절상태 실태조사 (Research on the Refractive State Screening in Preschool Children)

  • 김정희
    • 한국안광학회지
    • /
    • 제6권2호
    • /
    • pp.105-109
    • /
    • 2001
  • 본 조사는 취학전 아동(7세)의 굴절상태의 실태를 알아보기 위해 익산시 소재 병설유치원 3곳 아동 123명(246안)을 대상으로 타각적, 자각적 굴절검사를 실시하여 나안시력 분포, 굴절이상의 종류별 분포, 난시안의 종류별 분포, 시력검사 경험 유 무, 안위이상을 분석하였다. 1. 나안시력이 0.7이하인 아동은 64안(26%)으로 나타났다. 2. 근시성 굴절이상안(단순근시 및 근시성 난시)과 원시성 굴절이상안(단순원시 및 원시성난시)이 각각 26.55%로 나타났다. 3. 난시의 종류별 분포는 직난시 85.8%, 도난시 8.9%, 사난시 5.3%로 나타났다. 4. 시력검사를 받은 경험이 있는 아동은 13.8%로 나타났다. 5. 사위를 가진 아동은 없었다.

  • PDF

국내 중앙 일간지 환경보도의 정확성에 관한 연구 (A study on the accuracy of environmental reporting in korean nine dailies)

  • 안종주
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2002년도 춘계 국제 학술대회
    • /
    • pp.52-54
    • /
    • 2002
  • Generally, inaccurate reports on environmental issues occur due to various factors. The purpose of this study was to find out a way to enhance accuracy of environmental reporting. So the reporters' career and college major had been compared to the accuracy of their articles. The by-lined environmental articles in nine dailies published in 1991 were checked. Results of this study were as follows. (1) Inaccuracy rate in environmental articles was 54.2%. Inaccuracies appeared 1.7 times per an article, while the average frequency of inaccuracies in overall articles was 0.9 time. (2) Errors in the articles consist of 65.8% of subjective inaccuracies and 34.2% of subjective inaccuracies. They derive from the false usage of terminology(15.8%), misquotation(14.5%), incorrect statistics(13%), exaggeration(13%), inaccurate title(7.9%), and false comparison(5%), (3) Inaccuracy rate by the type of articles was 66.7% in columns, 60% in feature stories, 54.5% in-depth stories, 40.9% in straight news, respectively. (4) Inaccuracy rate by the specific field was shown 71.4% in environmental impacts (5) According to the result of chi-square test analysis, there were no statistically significant differences of inaccuracy rate and of subjective, and objective, and objective inaccuracies relevant to the period of reporters' career covering environmental reporting and the nature of articles, and college major.

  • PDF

국내 중앙 일간지 환경보도의 정확성에 관한 연구 (A Study on Accuracy of Environmental Reporting in Korean Major Dailies)

  • 안종주
    • 한국환경보건학회지
    • /
    • 제28권1호
    • /
    • pp.31-39
    • /
    • 2002
  • Generally, inaccurate reports on environmental issues occur due to various factors. The purpose of this study was to find out a way to enhance accuracy of environmental reporting. So the reporters' career and college major had been compared to the accuracy of their articles. The by-lined environmental articles in nine dailies published in 1991 were checked. Results of this study were as follows. (I) Inaccuracy rate in environmental articles was 54.2%. Inaccuracies appeared 1.7 times per an article, while the average frequency of inaccuracies in overall articles was 0.9 time. (2) Errors in the articles consist of 65.8% of subjective inaccuracies and 34.2% of subjective inaccuracies. They derive from the false usage of terminology(15.8% ),misquotation(14.5%), incorrect statistics(13%), exaggeration(13%), inaccurate title(7.9%), and false comparison(5%). (3) Inaccuracy rate by the type of articles was 66.7% in columns, 60% in feature stories, 54.5% in-depth stories, 40.9% in straight news, respectively. (4) Inaccuracy rate by the specific field was shown 71.4% in environmental impacts assessment, 52.5% in water pollution, 37.5% in waste management, and 35.7% in air pollution. (5) According to the result of chi-square test analysis, there were no statistically significant differences of inaccuracy rate and of subjective, and objective inaccuracies relevant to the period of reporters' career covering environmental reporting and the nature of articles, and college major.

PET/CT 검사에서 매개변수 입력오류에 따른 표준섭취계수 평가 (The Evaluation of SUV Variations According to the Errors of Entering Parameters in the PET-CT Examinations)

  • 김지아;홍건철;이혁;최성욱
    • 핵의학기술
    • /
    • 제18권1호
    • /
    • pp.43-48
    • /
    • 2014
  • PET/CT검사에서 표준섭취계수(standardized uptake value, SUV)는 병소의 악성 여부를 판별하는 지표로서 인체내 각 장기의 생리적인 변화에 대한 정량분석을 가능하게 한다. 따라서 그 결과에 영향을 줄 수 있는 매개변수를 올바르게 입력하는 것이 매우 중요하다. 본 연구에서는 그 매개변수 중 방사능량, 체중, 방사성 동위원소 섭취시간의 입력오류에 따른 결과의 차이를 측정하여 수용 가능한 결과의 오차범위를 평가하고자 한다. 1994 NEMA 모형 내부에 열소, 테프론, 그리고 공기 3개의 삽입물을 위치시켰다. 총 27.3 MBq의 $^{18}F$를 열소와 배후 방사능 비율이 4:1로 되도록 채우고 GE Discovery STE 16(GE Healthcare, Milwaukee, USA)로 촬영하였다. 촬영 후 입력된 방사능량, 체중, 섭취 시간의 값을 기준 값에서 ${\pm}5%$, 10%, 15%, 30%, 50% 만큼 오차를 발생시킨 후 영상을 다시 재구성하였다. 재구성된 영상에서 각 삽입물 부위에 한 개, 배후방사능 부위에 총 네 개의 관심영역을 그린 후 $SUV_{mean}$과 백분율오차를 측정하여 비교 평가하였다. 기준 영상의 열소, 테프론 그리고 공기와 배후방사능에서의 $SUV_{mean}$은 각각 4.5, 0.02, 0.1 그리고 1.0이였다. 방사능량 오차 변화에 따른 $SUV_{mean}$의 최대값과 최소값은 열소에서 9.0, 3.0, 테프론에서 0.04, 0.01, 공기에서 0.3, 0.1, 배후 방사능에서 2.0, 0.6로 변화된 값을 보였다. 이 때 백분율오차는 모두 동일하게 최대 100%에서 최소 -33%로 나타났다. 체중 오차 변화의 경우 열소에서 2.2, 6.7, 테프론에서 0.01, 0.03, 공기에서 0.09. 0.28, 배후방사능에서 0.5, 1.5로 변화된 값을 보였다. 이 때 백분율오차는 테프론의 최소 -50%, 최대 52%를 제외하고 모두 최소 -50%에서 최대 50% 로 동일하게 나타났다. 섭취시간 오차의 경우 열소에서 3.8, 5.3, 테프론에서 0.01, 0.02, 공기에서 0.1, 0.2, 배후방사능에서 0.8에서 1.2로 변화된 값을 보였다. 백분율오차는 열소와 배후방사능은 최소 -14%에서 최대 17%로 동일하게 나타났으며 테프론의 경우 최소 -11%에서 최대 21%, 공기의 경우 최소 -12%에서 최대 20%로 나타났다. 일반적으로 수용 가능한 오차의 범위를 5%로 설정할 경우, 본 실험 결과에서 방사능량과 체중의 오차가 ${\pm}5%$ 이내 일 때 $SUV_{mean}$의 오차가 5% 범위에 포함되었다. 이러한 결과들을 고려해 볼 때 검사장비에 입력되는 방사능량과 체중에 직접적인 영향을 줄 수 있는 선량검량계와 체중계의 검교정은 오차범위 5% 이내로 이루어져야 한다. 섭취 시간의 경우 삽입물의 종류에 따라 서로 다른 오차 범위를 보였으며 열소와 배후방사능에서 오차가 ${\pm}15%$ 이내일 때 $SUV_{mean}$에 5% 내의 오차가 발생하였다. 따라서 검사 시 촬영용 스캐너를 포함하여 두 개 이상의 시계를 사용할 경우 각각의 시간 오차들도 함께 고려되어야 할 것이다.

  • PDF

고(高)에너지 전자선(電子線) 치료(治療)를 위(爲)한 선량분포(線量分布) 및 기술적(技術的) 문제(問題)의 연구(硏究) (Studies on Dose Distribution and Treatment Technique of High Energy Electron)

  • 이도행;추성실
    • Journal of Radiation Protection and Research
    • /
    • 제3권1호
    • /
    • pp.6-22
    • /
    • 1978
  • High energy electron beams took effect for tumor radio-therapy, however, had a lot of problems in clinical application because of various conversion factors and complication of physical reactions. Therefor, we had experimentally studied the important properties of high energy electron beams from the linear accelerator, LMR-13, installed in Yonsei Cancer Center. The results of experimental studies on the problems in the 8, 10, 12 Mev electron beam therapy were reported as following. 1. On the measurements of the outputs and absorbed doses, the ionization type dosimeters that had calibrated by $^{90}Sr$ standard source were suitable as under 3% errors for high energy electrons to measure, but measuring doses in small field sizes and the regions of rapid fall off dose with ionization chambers were difficult. 2. The electron energy were measured precisely with energy spectrometer consisted of magnet analyzer and tele-control detector and the practical electron energy was calculated under 5% errors by maximum range of high energy electron beam in the water. 3. The correcting factors of perturbated dose distributions owing to radiation field, energy and material of the treatment cone were checked and described systematically and variation of dose distributions due to inhomogeneous tissues and sloping skin surfaces were completely compensated. 4. The electron beams, using the scatterers; ie., gold, tin, copper, lead, aluminium foils, were adequately diffused and minimizing the bremsstrahlung X-ray induced by the electron energy, irradiation field size and material of scatterers, respectively. 5. Inproving of the dose distribution from the methods of pendulum, slit, grid and focusing irradiations, the therapeutic capacity with limited electron energy could be extended.

  • PDF

Evaluation of a Solar Flare Forecast Model with Cost/Loss Ratio

  • Park, Jongyeob;Moon, Yong-Jae;Lee, Kangjin;Lee, Jaejin
    • 천문학회보
    • /
    • 제40권1호
    • /
    • pp.84.2-84.2
    • /
    • 2015
  • There are probabilistic forecast models for solar flare occurrence, which can be evaluated by various skill scores (e.g. accuracy, critical success index, heidek skill score, true skill score). Since these skill scores assume that two types of forecast errors (i.e. false alarm and miss) are equal or constant, which does not take into account different situations of users, they may be unrealistic. In this study, we make an evaluation of a probabilistic flare forecast model (Lee et al. 2012) which use sunspot groups and its area changes as a proxy of flux emergence. We calculate daily solar flare probabilities from 1996 to 2014 using this model. Overall frequencies are 61.08% (C), 22.83% (M), and 5.44% (X). The maximum probabilities computed by the model are 99.9% (C), 89.39% (M), and 25.45% (X), respectively. The skill scores are computed through contingency tables as a function of forecast probability, which corresponds to the maximum skill score depending on flare class and type of a skill score. For the critical success index widely used, the probability threshold values for contingency tables are 25% (C), 20% (M), and 4% (X). We use a value score with cost/loss ratio, relative importance between the two types of forecast errors. We find that the forecast model has an effective range of cost/loss ratio for each class flare: 0.15-0.83(C), 0.11-0.51(M), and 0.04-0.17(X), also depending on a lifetime of satellite. We expect that this study would provide a guideline to determine the probability threshold for space weather forecast.

  • PDF