• Title/Summary/Keyword: Two-step Method

Search Result 2,393, Processing Time 0.033 seconds

Effects of various combinations of cryoprotectants and cooling speed on the survival and further development of mouse oocytes after vitrification

  • Cha, Soo-Kyung;Kim, Bo-Yeun;Kim, Mi-Kyung;Kim, You-Shin;Lee, Woo-Sik;Yoon, Tae-Ki;Lee, Dong-Ryul
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.38 no.1
    • /
    • pp.24-30
    • /
    • 2011
  • Objective: The objectives of this study were to analyze efficacy of immature and mature mouse oocytes after vitrification and warming by applying various combinations of cryoprotectants (CPAs) and/or super-rapid cooling using slush nitrogen ($SN_2$). Methods: Four-week old ICR female mice were superovulated for GV- and MII-stage oocytes. Experimental groups were divided into two groups. Ethylene glycol (EG) only group: pre-equilibrated with 1.5 M EG for 2.5 minutes and then equilibrated with 5.5 M EG and 1.0 M sucrose for 20 seconds. EG+dimethylsulfoxide (DMSO) group: pre-equilibrated with 1.3 M EG+1.1 M DMSO for 2.5 minutes and equilibrated with 2.7 M EG+2.1 M DMSO+0.5 M sucrose for 20 seconds. The oocytes were loaded onto grids and plunged into $SN_2$or liquid nitrogen ($LN_2$). Stored oocytes were warmed by a five-step method, and then their survival, maturation, cleavage, and developmental rates were observed. Results: The EG only and EG+DMSO groups showed no significant difference in survival of immature oocytes vitrified after warming. However, maturation and cleavage rates after conventional insemination were greater in the EG only group than in the EG+DMSO group. In mature oocytes, survival, cleavage, and blastocyst formation rates after warming showed no significant difference when EG only or EG+DMSO was applied. Furthermore, cleavage and blastocyst formation rates of MII oocytes vitrified using $SN_2$ were increased in both the EG only and EG+DMSO groups. Conclusion: A combination of CPAs in oocyte cryopreservation could be formulated according to the oocyte stage. In addition, $SN_2$ may improve the efficiency of vitrification by reducing cryoinjury.

Development of Bivalve Culture Management System based on GIS for Oyster Aquaculture in GeojeHansan Bay (거제한산만 굴 양식장에 대한 GIS 기반 어장관리시스템 개발)

  • Cho, Yoon-Sik;Hong, Sok-Jin;Kim, Hyung-Chul;Choi, Woo-Jeung;Lee, Won-Chan;Lee, Suk-Mo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.16 no.1
    • /
    • pp.11-20
    • /
    • 2010
  • Oyster production is playing an important role in domestic aquaculture, but facing some problems such as exports decrease, a slowdown in domestic demand and marine environmental deterioration. In order to obtain the suitable and sustainable oyster production, suitable sites selection is an important step in oyster aquaculture. This study was conducted to identify the suitable sites for lunging culture of oyster using Geographic Information System(GIS)-based multi-criteria evaluation methods. Most of the parameters were extracted by Inverse Distance Weighted(IDW) methods in GIS and eight parameters were grouped into two basic sub-models for oyster aquaculture, namely oyster growth sub-model(Sea Temperature, Salinity, Hydrodynamics, Chlorophyll-a) and environment sub-model(Bottom DO, TOC, Sediment AVS, Benthic Diversity). Suitability scores were ranked on a scale from 1(leased suitable) and 8(most suitable), and about 80.1% of the total potential area had the highest scores 5 and 6. These areas were shown to have the optimum condition for oyster culture in GeojeHansan Bay. This method to identify suitable sites for oyster culture may be used to develop bivalve culture management system for supporting a decision making.

A Study of the Proper Sizing of a Subway Station Waiting Area (도시철도 대기공간의 적정규모 산정에 관한 연구)

  • Kim, Jonghwang;Baek, Sungjoon;Nam, Doohee
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.2
    • /
    • pp.262-269
    • /
    • 2016
  • Subway station scales are determined by peak predictions. In this study, the purpose behind the installation of a subway is public transportation convenience and public interest, but economic validity is also important. By proving that the scale of the station is excessive with regard to the target station size for Seoul subway Line 5-8, a reasonable plan. can be sought. According to station installation standards, the area of the station under investigation here is out of the service levels by six stages (A~F), and it must be four or more levels (D). The Actual level for the B level is a two-step design. The Actual ratio for over- Peak predictions is only 17.8% on average. The results of measurements of the excess area and determination of the excessive costs were analyzed by subdividing the area and by calculating it based on the B level, finding that it is possible to provide benefits for customers only in the current design, with an area ratio of 16.3%. Given the weight, it was estimated that current conditions can meet the needs of only 18.6% of the current area. Simplifying the scale calculation method of the station, it is convenient, safe, and advantageous to move citizens only if the scale can be streamlined. Then, with a reduced initial investment, maintenance costs during the operation can be reduced.

Analysis of Response Time and Reflectivity According to Driving Conditions of Barrier Rib-Type E-Paper Fabricated by Charged Particle Filtering Method (격벽형 전자종이의 하전입자 필터링 방법 및 구동조건에 따른 응답시간 및 반사율 분석)

  • Lee, Joo-Won;Kim, Young-Cho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.6
    • /
    • pp.475-482
    • /
    • 2020
  • For electronic paper displays using electrophoresis, the response time and reflectivity of the image panel fabricated by filtering are analyzed. For the filtering process, a square wave and ramp wave are applied to white charged particles with a unique q/m value. We divide the sample panels into #1 to #4 according to the applied waveform in the filtering process. Step waves comprising two steps are used to drive the panel; therefore, we divide the driving conditions into D1~D4. The applied voltage at the first stage of the half cycle of the driving waveform moves the charged particles attached via the image force from the electrode, and the applied voltage at the second stage moves the floating charged particles by detaching. As mentioned, four types of driving conditions (D1 to D4) classified according to the half cycle of the driving waveform are applied to the samples #1 to #4), which are classified according to four types of filtering process. When driving condition D1 is applied to the four types of sample panels, the rise time of #1 is 1.59s, #2 is 1.706s, #3 is 1.853s, and #4 is 1.235s, resulting in #4 being relatively faster compared with other sample panels, and showing the same trend in other driving conditions. As a result, we confirm that applying the driving condition D1 causes abrupt movement of the white charged particles injected into the cell. When the same driving waveform (D1) is applied to each sample, reflectivities of 32.1% for #1, 31.4% for #2, 27.9% for #3, and 63.4% for #4 are measured. From the experiment, we confirm that the driving condition D1 (1s of 3.5 V, 9s of 3.0 V) and ramp wave #4 in filtering are desirable for good reflectivity and response time. Our research is expected to contribute to the improvement of the filtering process and optimization of the driving waveform.

A Prospective Observational Study on Symptoms of the Postpartum Women with Korean Medicine Treatment during Six Weeks after Childbirth (한의치료를 받은 산모의 산후 6주간 증상에 대한 전향적 관찰 연구)

  • Kim, Pyung-Wha;Kim, An-Na;Jang, Hyun-Chul;Lee, Eun-Hee
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.30 no.4
    • /
    • pp.114-134
    • /
    • 2017
  • Objectives: This study aims to investigate the changes of women's postpartum symptoms, including their weights, edema index and quality of life (QOL) over the first six weeks after childbirth. Methods: The study participants were 31 postpartum women treated in the Dept. of Obstetrics & Gynecology, at Woo-Suk University Korean Medicine Hospital, from May 20th to August 5th, 2016. In the first 2 weeks of the postpartum period, the main data collection method was to interview each patient and write down all of their complaints, and additionally referring to each participant's PHR (Personal Health Records). At the 3rd, 4th, 5th and 6th week, the researcher interviewed participants by phone once a week. The participants' weight, edema index (ECW/TBW) and the quality of life (by EQ-VAS) were measured at 1st and 2nd week after childbirth. And, EQ-VAS was assessed once more at the 6th week after childbirth. As a last step, the participants responded to a survey on satisfaction regarding their postpartum care with Korean Medicine. Results: 1. In the 1st one week after childbirth, edema was the most frequent complaint. It was about joint pain of the upper limbs in the 2nd and 3rd weeks, sweating in the 4th week, and joint pain of the upper limbs in the 5th and the 6th weeks. 2. In the 1st two weeks of the postpartum period, the weight of the participants decreased from $66.33{\pm}9.30kg$ to $62.60{\pm}8.92kg$ (p<0.001) and the edema index ECW/TBW decreased from $0.399{\pm}0.010$ to $0.385{\pm}0.0 4$ (p<0.001). The EQ-VAS significantly improved from $61.77{\pm}17.72$ to $73.51{\pm}14.67$ (p<0.001). In the last 4-weeks of the postpartum period, the EQ-VAS decreased from $74.30{\pm}14.25$ to $73.63{\pm}13.35$, but this difference was not statistically significant (p=0.749). 3. Regarding the satisfaction with postpartum care with Korean Medicine, 60% of the participants responded that it was 'Excellent' and 40% said it was 'Good'. Conclusion: Over the entire postpartum period, the most frequent complaints were about musculoskeletal symptoms. Postpartum care with Korean Medicine treatments in the early postpartum period improves various postpartum symptoms and the quality of life for postpartum women.

Control of heparinization by activated clotting time during extracorporeal circulation (개심술시 Activated Clotting Time 을 이용한 Heparin 투여 조절에 관한 임상적 고찰)

  • 서충헌
    • Journal of Chest Surgery
    • /
    • v.16 no.3
    • /
    • pp.281-288
    • /
    • 1983
  • Heparinization is an essential step in extracorporeal circulation for open heart surgery. But wide individual variation to heparin effect sometimes makes it difficult to anticoagulate safely or neutralize appropriately. Because the conventional set protocol of heparinization did not consider this individual variation, a new method of control of heparinization was proposed by Dr. Brian Bull in 1974. We compared the group in which a conventional set protocol was used [Control group] with the other in which a new protocol modified from that of Bull was used [ACT group], on the aspects of the dosages of heparin and protamine administered and postoperative bleeding. Our conventional protocol [Control group] consisted of: 1. Initial heparin was given at dose of 350U/Kg into the right atrium prior to bypass. 2. Additional heparin was given every hour during E.C.C., as much as a half of the Initial dose. 3. 600U of heparin was mixed into every 100ml. of priming solution. 4. The protamine dose was calculated by totalling the units of heparin given to the patient and giving 1 .8mg. of protamine per 100 units of heparin. ACT protocol [ACT group] consisted of: 1. Initial heparinization was same as that of conventional protocol. 2. ACT`s were checked before [A point] and 10 minutes after initial heparinization [B point]. With these 2 points, a dose response curve was drawn. 3. Heparin for the priming solution was same as in control group. 4. Every 30 minutes during E.C.C., ACT`s were checked with Hemochron [International Technidyne Corp.]. ACT between 450 and 600 seconds was regarded as safety zone. If ACT checked at a time was below 450 seconds, heparin dose was calculated on the dose-response curve to lengthen ACT to 480 seconds and was given into the oxygenator. 5. About 10 minutes before the term of E.C.C., ACT was checked to estimate the blood heparin level at the time. Then, protamine dose was calculated at dose of 1.Stag per 100 units of heparin. The calculated dose of protamine was mixed into 50 to lO0ml of 5% Dextrose Water and dripped intravenously during the period of 15 minutes. Compared these two groups mentioned above, results were obtained as follows: 1. Mean value of normal ACT checked with Hemochron on 30 preoperative patients was 124 seconds [range 95-145 sec.]. 2. Doses of heparin and protamine given to the patient were decreased in ACT group as much as 32.2% and 62.2% respectively. 3. Postoperative bleeding and transfusion were also decreased in ACT group in 60.5% and 67.1% respectively. 4. Our modified dose-response curve did not cause any problems in the control of heparinization. 5. Initial heparinization [Heparin 350U/Kg] was sufficient for the most patients until 60 minutes under extracorporeal circulation. 6. We used 1.5mg of protamine to neutralize 100 units of heparin. But smaller dose of protamine may be sufficient for appropriate neutralization.

  • PDF

A Study on Causes of Franchisee's Conflict in Distribution Channel of small and middle sized Franchise Industry (중소형 프랜차이즈 유통시스템에서 가맹점의 갈등에 관한 질적 연구 - 토대이론 접근법을 활용하여-)

  • Jeon, Ta-sik
    • Journal of Distribution Science
    • /
    • v.4 no.2
    • /
    • pp.21-40
    • /
    • 2006
  • Small and middle sized Franchise system channels experience conflicts because of constant interaction between franchiser and franchisee. However, it is rarely that attempt has been made to identify causes of conflicts in distribution of franchise industry. The purpose of this study was to explore cause of conflicts from the franchisee. For the study, data were collected from the owner or the shop-manager with a contractor in franchise systems. By means of in-depth interviews with multiple informants, their statement was analyzed qualitatively. From analysis of the resulting data, the causes of conflicts were associated with two broad sets, attitudinal and structural differences between franchisers and franchisees. First, attitudinal sources of conflict were identified as perception of subordinated relationships between channel members, delayed announcement on order changes, difficulties in communication by doing irresponsible behavior, different expectations between channel members in market territory and lack of consistent-supporting. Second, structural sources of conflict involved unilateral decision on interior, payment method, unreasonable delivery issue, treat franchisee with discrimination by the sales, in controlling against free management. There are limitations on generalization due to the results based on interview, but this study will be a useful exploratory step before designing a large scale survey.

  • PDF

Geographical Name Denoising by Machine Learning of Event Detection Based on Twitter (트위터 기반 이벤트 탐지에서의 기계학습을 통한 지명 노이즈제거)

  • Woo, Seungmin;Hwang, Byung-Yeon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.4 no.10
    • /
    • pp.447-454
    • /
    • 2015
  • This paper proposes geographical name denoising by machine learning of event detection based on twitter. Recently, the increasing number of smart phone users are leading the growing user of SNS. Especially, the functions of short message (less than 140 words) and follow service make twitter has the power of conveying and diffusing the information more quickly. These characteristics and mobile optimised feature make twitter has fast information conveying speed, which can play a role of conveying disasters or events. Related research used the individuals of twitter user as the sensor of event detection to detect events that occur in reality. This research employed geographical name as the keyword by using the characteristic that an event occurs in a specific place. However, it ignored the denoising of relationship between geographical name and homograph, it became an important factor to lower the accuracy of event detection. In this paper, we used removing and forecasting, these two method to applied denoising technique. First after processing the filtering step by using noise related database building, we have determined the existence of geographical name by using the Naive Bayesian classification. Finally by using the experimental data, we earned the probability value of machine learning. On the basis of forecast technique which is proposed in this paper, the reliability of the need for denoising technique has turned out to be 89.6%.

Quantifying the effects of climate variability and human activities on runoff for Vugia - Thu Bon River Basin in Central of Viet Nam

  • Lan, Pham Thi Huong;Thai, Nguyen Canh;Quang, Tran Viet;Long, Ngo Le
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.233-233
    • /
    • 2015
  • Vu Gia - Thu Bon basin is located in central Vietnam between Truong Son mountain range on the border with Lao in the west and the East Sea in the east. The basin occupies about 10,350 km2 or roughly 90% of the Quang Nam Province and includes Da Nang, a very large city with about 876,000 inhabitants. Total annual rainfall ranges from about 2,000 mm in central and downstream areas to more than 4,000 mm in southern mountainous areas. Rainfall during the monsoon season accounts for 65 to 80% of total annual rainfall. The highest amount of rainfall occurs in October and November which accounts for 40 to 50% of the annual rainfall. Rainfall in the dry season represents about 20 to 35% of the total annual rainfall. The low rainfall season usually occurs from February to April, accounting for only 3 to 5% of the total annual rainfall. The mean annual flow volume in the basin is $19.1{\times}109m 3$. Similar to the distribution of rainfall, annual flows are distinguished by two distinct seasons (the flood season and the low-flow season). The flood season commonly starts in the mid-September and ends in early January. Flows during the flood season account for 62 to 69% of the total annual water volume, while flows in the dry season comprise 22 to 38% of total annual run-off. The water volume gauged in November, the highest flow month, accounts for 26 to 31% of the total annual run-off while the driest period is April with flows of 2 to 3% of the total annual run-off. There are some hydropower projects in the Vu Gia - Thu Bon basin as the cascade of Song Bung 2, Song Bung 4, and Song Bung 5, the A Vuong project currently under construction, the Dak Mi 1 and Dak Mi 4 projects on the Khai tributary, and the Song Con project on the Con River. Both the Khai tributary and the Song Con join the Bung River downstream of SB5, although the Dak Mi 4 project involves an inter-basin diversion to Thu Bon. Much attention has recently been focused on the effects that climate variability and human activities have had on runoff. In this study, data from the Vu Gia - Thu Bon River Basin in the central of Viet Nam were analyzed to investigate changes in annual runoff during the period of 1977-2010. The nonparametric Mann-Kendall test and the Mann-Kendall-Sneyers test were used to identify trend and step change point in the annual runoff. It was found that the basin had a significant increasing trend in annual runoff. The hydrologic sensitivity analysis method was employed to evaluate the effects of climate variability and human activities on mean annual runoff for the human-induced period based on precipitation and potential evapotranspiration. This study quantitatively distinguishes the effects between climate variability and human activities on runoff, which can do duty for a reference for regional water resources assessment and management.

  • PDF

A Study on The Correlation Between Ego-state and Five Factor Model for Game Character's Personality (게임 캐릭터의 성격 정의를 위한 자아 상태와 5대 성격 요인의 연관성 연구)

  • Kim, Mi-Sun;Ko, Il-Ju
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.1
    • /
    • pp.75-83
    • /
    • 2015
  • As the importance of realistic game character in order to cause the interest of player is increased, it is necessary to develop the character that acts like a man by applying the human characteristics in the step of game character design. Formerly, there is a limit to create the human-like character because there is no set the character's personality in the game developing level. In this paper, therefore, we propose the correlation between Five Factor Model and Ego-state for game character. Five Factor Model and Ego-state are theories about person's characteristic. Five Factor Model is personality description method. Ego-state has an emphasis on internal mental processes directly from observable behaviors. In this regard, these theories could be used to the character defined its personality and designed to act by personality. To do this, it needs to determine the relations between Five Factor Model and Ego-state. Therefore we seek for the relations between two theories using Adjective Check List(ACL) and analysis their results with surveys. In the future, it is expected to construct a personality model using these analysis results, and develop the character based on realistic behavior.