• 제목/요약/키워드: Two-point correlation

검색결과 509건 처리시간 0.026초

GALAXY CORRELATION IN A BUBBLY UNIVERSE

  • Ryu, Dong-Su
    • 천문학논총
    • /
    • 제7권1호
    • /
    • pp.25-30
    • /
    • 1992
  • Recent redshift surveys suggest that most galaxies may be distributed on the surfaces of bubbles surrounding large voids. To investigate the quantitative consistency of this qualitative picture of large-scale structure, we study analytically the clustering properties of galaxies in a universe filled with spherical shells. In this paper, we report the results of the calculations for the spatial and angular two-point correlation functions of galaxies. With ${\sim}20%$ of galaxies in clusters and a power law distribution of shell sizes, $n_{sh}(R){\sim}R^{-{\alpha}}$, ${\alpha}\;{\simeq}\;4$, the observed slope and amplitude of the spatial two-point correlation function ${\xi}_{gg}(r)$ can be reproduced. (It has been shown that the same model parameters reproduce the enhanced cluster two-point correlation function, ${\xi}_{cc}(r)$). The corresponding angular two-point correlation function $w({\theta})$ is calculated using the relativistic form of Limber's equation and the Schecter-type luminosity function. The calculated w(${\theta}$) agrees with the observed one quite well on small separations (${\theta}{\lesssim}2deg$).

  • PDF

다양한 회귀분석을 통한 강우유출용적에 따른 비점오염부하량 예측방안 (Predictive Relationships of the Nonpoint Source Pollutant Loads with Stormwater Runoff Volumes based on the Various Regression Analyses)

  • 신지웅;길경익
    • 한국물환경학회지
    • /
    • 제27권3호
    • /
    • pp.257-263
    • /
    • 2011
  • This study analyzes the correlations between non-point sources and runoff to estimate non-point sources for effective management. From the monitoring results, the correlation factors among pollutant mass loading, EMC, total runoff volume and average flow are calculated. And using correlation factors, the most related two constituents are determined. Also the most appropriate regression between two constituents are determined. Pollutant mass loading and total runoff volume has the highest correlation. Also, compound regression is found to be the most appropriate regression. This shows that pollutant mass loading increases as total runoff volume increases. It is not continuous increase but has some pattern.

The Correlation of Lower Flash Point data with Activity Coefficient Models

  • Ha, Dong-Myeong;Lee, Sungjin
    • International Journal of Safety
    • /
    • 제10권1호
    • /
    • pp.5-9
    • /
    • 2011
  • Two popular activity coefficient models, Wilson and NRTL equations have been used to correlate the published flash point data on the n-propanol + propionic acid and n-butanol + propionic acid systems through the optimization method. The results of these correlation were compared with the results calculated by Raoult's law. The optimization method were found to be better than those based on the Raoult's law. The optimization method based on the Wilson equation described the published data more effectively than was the case when the optimization method was based upon the NRTL equation.

  • PDF

갯벌에서 여름철 일몰 전후 이산화탄소 농도 변동 분석 (Variation Analysis of CO2 Concentrations at Sunset before and after of Summer Season at the Foreshore)

  • 강동환;권병혁;김박사
    • 한국환경과학회지
    • /
    • 제23권3호
    • /
    • pp.399-407
    • /
    • 2014
  • In this study, before and after sunset carbon dioxide concentration and air temperature were observed in two points of atmosphere (lower observation point of the GL + 0.1 m, the upper observation point of GL + 1.0 m) on the foreshore at located in Suncheon Bay and their variations were analyzed. Observation was performed on the foreshore on 2~4 August 2010. Instrument (VAISALA, GMP343) was set two hours before sunset and then observation was made continuously for six hours. In three days, observed carbon dioxide concentration was 375~419 ppm, and the air temperature was in the range of $28.7{\sim}32.5^{\circ}C$. The average concentration of carbon dioxide was 388~399 ppm in the upper observation point and 386~396 ppm in the lower observation point. It was higher in the upper observation point and its fluctuations were similar in two observation points. Correlation coefficients between carbon dioxide concentration and air temperature in the upper observation point were in the range of -0.64~-0.88, and were calculated -0.65 to -0.90 in the lower observation point. For the carbon dioxide concentration, correlation coefficients between the upper part and the lower part were very high as 0.98 in three times. For the air temperature, correlation coefficients between the upper part and the lower part were very high as 0.97 and 0.99. In the same observation time, the slope of the linear regression function as carbon dioxide concentration in the lower observation point for the upper observation point was in the range of 0.97~1.01. Carbon dioxide concentration was slightly higher in the upper observation point. Because carbon dioxide in the lower observation point was closer on the surface of the foreshore and absorbed from atmosphere to the foreshore. In this study, it was showed that the vertical variation of carbon dioxide concentration was insignificant in the several meter scale of atmosphere on the surface of the foreshore.

CMP cross-correlation analysis of multi-channel surface-wave data

  • Hayashi Koichi;Suzuki Haruhiko
    • 지구물리와물리탐사
    • /
    • 제7권1호
    • /
    • pp.7-13
    • /
    • 2004
  • In this paper, we demonstrate that Common Mid-Point (CMP) cross-correlation gathers of multi-channel and multi-shot surface waves give accurate phase-velocity curves, and enable us to reconstruct two-dimensional (2D) velocity structures with high resolution. Data acquisition for CMP cross-correlation analysis is similar to acquisition for a 2D seismic reflection survey. Data processing seems similar to Common Depth-Point (CDP) analysis of 2D seismic reflection survey data, but differs in that the cross-correlation of the original waveform is calculated before making CMP gathers. Data processing in CMP cross-correlation analysis consists of the following four steps: First, cross-correlations are calculated for every pair of traces in each shot gather. Second, correlation traces having a common mid-point are gathered, and those traces that have equal spacing are stacked in the time domain. The resultant cross-correlation gathers resemble shot gathers and are referred to as CMP cross-correlation gathers. Third, a multi-channel analysis is applied to the CMP cross-correlation gathers for calculating phase velocities of surface waves. Finally, a 2D S-wave velocity profile is reconstructed through non-linear least squares inversion. Analyses of waveform data from numerical modelling and field observations indicate that the new method could greatly improve the accuracy and resolution of subsurface S-velocity structure, compared with conventional surface-wave methods.

양육태도검사 예비형의 문항검사―재검사 신뢰도의 분석 (Analysis of Test-retest Reliability of Individual Items in a Preliminary From of Child-rearing Attitude Scale)

  • 차재호
    • 대한가정학회지
    • /
    • 제20권2호
    • /
    • pp.135-140
    • /
    • 1982
  • As a step preliminary to the factor-analysis of a child-rearing attitude scale under construction, its preliminary form containing a total of 368 self-answered questions was administerd to 88 married women with one or more children in the grade school age. all graduates of colleges and in possession of a home telephone and a house, twice from one week apart. The test-retest correlation coefficients, calculated for each test item based on the subject's choice among the three response alternatives on two test ocasions, ranged from .80 to .10. The cut-off point of r=.41 or lower led to the elimination of 48 items. As a point of incidental interest, the rate of response concordance. The namber of subjects giving the same categroy response on two occasions was calculated for each item and it was correlated with its test. retest correlation coefficient. The two different indices of item test-retest reliability were found not related to each other. Empirical evidence, as well as rational justifications, was presented to show that the correlation coefficient is the better of the tow indices of item test-retest reliability.

  • PDF

Assessment of The Accuracy of The MR Abdominal Adipose Tissue Volumetry using 3D Gradient Dual Echo 2-Point DIXON Technique using CT as Reference

  • Kang, Sung-Jin
    • Journal of Magnetics
    • /
    • 제21권4호
    • /
    • pp.603-615
    • /
    • 2016
  • In this study, in order to determine the validity and accuracy of MR imaging of 3D gradient dual echo 2-point DIXON technique for measuring abdominal adipose tissue volume and distribution, the measurements obtained by CT were set as a reference for comparison and their correlations were evaluated. CT and MRI scans were performed on each subject (17 healthy male volunteers who were fully informed about this study) to measure abdominal adipose tissue volume. Two skilled investigators individually observed the images acquired by CT and MRI in an independent environment, and directly separated the total volume using region-based thresholding segmentation method, and based on this, the total adipose tissue volume, subcutaneous adipose tissue volume and visceral adipose tissue volume were respectively measured. The correlation of the adipose tissue volume measurements with respect to the observer was examined using the Spearman test and the inter-observer agreement was evaluated using the intra-class correlation test. The correlation of the adipose tissue volume measurements by CT and MRI imaging methods was examined by simple regression analysis. In addition, using the Bland-Altman plot, the degree of agreement between the two imaging methods was evaluated. All of the statistical analysis results showed highly statistically significant correlation (p<0.05) respectively from the results of each adipose tissue volume measurements. In conclusion, MR abdominal adipose volumetry using the technique of 3D gradient dual echo 2-point DIXON showed a very high level of concordance even when compared with the adipose tissue measuring method using CT as reference.

강원도 지역여자고등학생들의 식생활 행동과 체중조절 태도에 관한 연구 (A Study on the Eating Behavior and the Attitude about Weight ’s Control of the High School Girls in Kangwondo)

  • 김경희;임양순
    • 한국가정과교육학회지
    • /
    • 제7권1호
    • /
    • pp.29-45
    • /
    • 1995
  • The purpose of this study was to investigate eating behavior and the attitude about weight control of the High School Girls. The questionnaires were completed by 519 girls’ high school students.(lived in city ; 269, in mine region ; 250) The results were as follows: 1. The average stature of them was 159.01${\pm}$5.09cm, the average weight was 51.64${\pm}$6.76kg. 2. In the present body structure of them, the underweight structure was 26.2% the normal weight structure was 58.4% the overweight structure was 15.4%. The present body structure was very different from the recognition of their own body structure. 3. The average point of the eating behavior was 52.07 and that of city(53.62 point) was higher than mine region(50.01 point). 4. The rate of going without breakfast(P<0.05) the frequency of snack(p<0.001) the eating rate of stimulus foods(p<0.05) the interest healthy food life(p<0.05) in two regions showed the significant difference. 5. The point of eating behavior in two regions showed the positive correlation in the economic level, the contentment degree of the present body structure, the conscious healthy condition. But it showed the negative correlation in the rate of going without of breakfast. On observing the difference of the tow regions, it showed the positive correlation to mother’s education career on the negative relation to the experience of the weight control in the city. In the other hand it showed the negative correlation to the recognition on degree of the present body structure in the mine region. 6. The contentment degree of the present body structure showed the negative correlation to the experience of the weight control. Also it showed the negative correlation to the rate of going without breakfast in the city.

  • PDF

On the Study of Perfect Coverage for Recommender System

  • Lee, Hee-Choon;Lee, Seok-Jun
    • Journal of the Korean Data and Information Science Society
    • /
    • 제17권4호
    • /
    • pp.1151-1160
    • /
    • 2006
  • The similarity weight, the pearson's correlation coefficient, which is used in the recommender system has a weak point that it cannot predict all of the prediction value. The similarity weight, the vector similarity, has a weak point of the high MAE although the prediction coverage using the vector similarity is higher than that using the pearson's correlation coefficient. The purpose of this study is to suggest how to raise the prediction coverage. Also, the MAE using the suggested method in this study was compared both with the MAE using the pearson's correlation coefficient and with the MAE using the vector similarity, so was the prediction coverage. As a result, it was found that the low of the MAE in the case of using the suggested method was higher than that using the pearson's correlation coefficient. However, it was also shown that it was lower than that using the vector similarity. In terms of the prediction coverage, when the suggested method was compared with two similarity weights as I mentioned above, it was found that its prediction coverage was higher than that pearson's correlation coefficient as well as vector similarity.

  • PDF

음향방출 및 상관법을 이용한 상수도배관 누수탐지 연구 (Leak Detection of Waterworks Pipeline Using Acoustic Emission and Correlation Method)

  • 윤동진;정중채;이영섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.84-89
    • /
    • 2003
  • Water leak is one of topics with great concern in Korea and many other countries, because of decreasing water supplies and the deterioration of old pipeworks. Correlation techniques have been widely used in leak detection of water pipes, which allow to locate a leak point based on the correlation of leak noise at two sites along water pipes. In this study, both the cross-correlation method and the conventional arrival time difference method are applied in order to analyze and to locate a leak point of a water pipe. In experiment, a 150 m of whole length waterwork pipeline system was constructed in a ground, and several types of leak noise were installed on the pipeline in order to control leak condition. Both the cross-correlation technique and the arrival time difference method showed favorable results at leak detection with the experimental pipeline system.

  • PDF