전산해석과 실험의 비교검증을 통한 원통형 수중운동체 주위의 캐비테이션 유동현상 연구 (COMPARISON OF CFD SIMULATION AND EXPERIMENT OF CAVITATING FLOW PAST AXISYMMETRIC CYLINDER)

  • 박형만;박원규;정철민
    • 한국전산유체공학회지
    • /
    • 제17권1호
    • /
    • pp.78-85
    • /
    • 2012
  • Cavitation causes a great deal of noise, damage to components, vibrations, and a loss of efficiency in devices, such as propellers, pump impellers, nozzles, injectors, torpedoes, etc., Thus, cavitating flow simulation is of practical importance for many engineering systems. In this study, a two-phase flow solver based on the homogeneous mixture model has been developed. The flow characteristics around an axisymmetric cylinder were calculated and then validated by comparing with the experimental results in the cavitation water tunnel at the Korea Ocean Research & Development Institute. The results show that this solver is highly suitable for simulating the cavitating flows. After the code validation, the cavity length with changes of water depth, angle of attack and velocity were obtained.. Cavitation inception was also calculated for various operational conditions.

Shearing Conditions on the Interface of a Spherical Water Drop Sinking in Silicone Oil

  • Uemura, Tomomasa;Yamauchi, Makoto
    • Journal of Mechanical Science and Technology
    • /
    • 제15권12호
    • /
    • pp.1845-1852
    • /
    • 2001
  • This paper deals with the experiment to obtain quantitative information about conditions of the interface between a water drop and surrounding oil. Velocity distributions in very close region of the interface are measured by introducing a new illumination technique and a telecentric lens. It enables precise measurements of velocity distributions in the close region to the interface. Although the measured velocity distributions exhibit strong influence from the solid wall of an experimental tube, the coincidence of inner and outside velocities on the interface is clearly confirmed for the clean interface. The shearing stresses on the interface, which are proportional to the velocity gradient normal to the interface, clearly show conditions of contaminated interface, which can be divided into two parts. From front stagnation point to somewhere near a separation point, the distribution of shearing stresses is well coincide with that of the Hadamard's analytical solution, while the distribution on the latter part of the interface sows quite different feature, which is supposed to be strongly influenced by contamination of the surface.

  • PDF

자동차용 IRDS 응축기에 대한 실험과 해석적 연구 (An Experimental and Numerical Study on Automotive IRDS Condenser)

  • 김학준
    • 한국자동차공학회논문집
    • /
    • 제19권1호
    • /
    • pp.58-65
    • /
    • 2011
  • The specific objective of this study was to develop an IRDS (integrated receiver drier subcooling) condenser model for use in a mobile air-conditioning system. A three-zone model based on the desuperheating, two-phase, and subcooling sections of a condenser could be used to estimate the performance with a good accuracy. Overall heat transfer coefficients for each of the three sections, expressed as a function of the air velocity across the condenser and refrigerant mass flow rate and the model using the elemental difference method incorporate calculations to determine the pressure drop, heat performance within the condenser and it includes physical parameters (pass, tube hole size and length) that can be varied to analyze potential design changes without exhaustive experimental efforts. it was found that an accuracy of heat performance was within 5% in case of using the various condensers, the refrigerant pressure drop was predicted within 25% and the pressure drop of air side was well matched with experiment data within 4%.

A Novel Control Strategy for HEV Using Brushless Dual-Mechanical-Port Electrical Machine on Cruising Condition

  • Wang, Ende;Huang, Shenghua;Wan, Shanming;Chen, Xiao
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.523-531
    • /
    • 2014
  • Brushless Dual-Mechanical-Port Electrical Machine (BLDMPEM) is a new type of motor designed for Hybrid Electric Vehicle (HEV), which contains two mechanical ports and two electric ports. Compared with Dual-Mechanical-Port Electrical Machine (DMPEM), the brushless structure brings higher reliability and easier maintenance. In this paper, the model of BLDMPEM is discussed. In Chapter 2, the energy flow and mathematical model of BLDMPEM are analyzed. Then a novel three-phase half-bridge controlled rectifier topology and its control strategy for cruising mode of HEV based on BLDMPEM are proposed in Chapter 3. Compared with the Field Oriented Control (FOC) strategy of BLDMPEM, the proposed method does not require accurate motor parameters, and it is much simpler and easier to be implemented. At last, simulation and experiment results show the feasibility and validity of the proposed strategy.

건강한 성인 지원자를 대상으로 한 필로칼핀 저작정의 타액분비 유도 및 타액중 용출패턴 평가 (Evaluations on Salivary Flow Induction and Dissolution Patterns in Saliva of Pilocarpine Chewing Tablet in Healthy Human Volunteers)

  • 박경호
    • Journal of Pharmaceutical Investigation
    • /
    • 제27권4호
    • /
    • pp.331-335
    • /
    • 1997
  • Xerostomia is caused by organic or functional changes affecting the salivary system at different levels. Patients suffering from xerostomia may also complain of an oral burning sensation, ulceration or soreness, difficulty in swallowing, and poor denture retention. And pilocarpine is administered orally to induce salivary secretion. In Seoul National University Hospital(SNUH) pharmacy, the pilocarpine chewing tablets are prepared and supplied to patients of xerostomia in request of the dental hospital in SNUH. And we tested the salivary flow induction and the dissolution patterns of these products in saliva by a double-blind, sequential cross-over trials to eight healthy human volunteers with placebo. The pilocarpine chewing tablet contained 5 mg of pilocarpine, and placebo consisted of same materials as test drug, but didn't contain pilocarpine. In vivo experiment, all subjects were instructed to chew as 60-80 times/min. Mixed saliva was collected in the ranges of intervals such as 0-2, 2-5, 5-10, 10-15, 15-20, 20-30, 30-45 and 45-60 min after pilocarpine chewing tablet or placebo administration. Saliva volume was measured in each collecting time interval, and saliva pilocarpine concentrations were determined by reversed phase HPLC. The 82.5 percent $(4.13{\pm}0.69\;mg)$ of pilocarpine was extracted from chewing tablets during mastication of 60-80 times per minute for 60 minutes. Among these dissolved amounts, 90 percent was extracted within 20 minutes. The salivary flow rates were more increased in a group who administered pilocarpine chewing tablet at the interval of 5-10, 10-15, 20-30 and 45-60 min rather than a placebo-group, but only extracted amount of pilocarpine at 45-60 min interval is significanly different between two groups (p<0.05). But total amounts of saliva secreted for 1 hour in two group-pilocarpine and placebo treated- were $46.36{\pm}9.72\;ml\;and\;39.09{\pm}7.81\;ml$, respectively, and were not significantly different between two groups.

  • PDF

ANALYSIS OF A STATION BLACKOUT SCENARIO WITH AN ATLAS TEST

  • Kim, Yeon-Sik;Yu, Xin-Guo;Kang, Kyoung-Ho;Park, Hyun-Sik;Cho, Seok;Choi, Ki-Yong
    • Nuclear Engineering and Technology
    • /
    • 제45권2호
    • /
    • pp.179-190
    • /
    • 2013
  • A station blackout experiment called SBO-01 was performed at the ATLAS facility. From the SBO-01 test, the station blackout scenario can be characterized into two typical phases: A first phase characterized by decay heat removal through secondary safety valves until the SG dryouts, and a second phase characterized by an energy release through a blowdown of the primary system after the SG dryouts. During the second phase, some physical phenomena of the change over a pressurizer function, i.e., the pressurizer being full before the POSRV $1^{st}$ opening and then its function being taken by the RV, and the termination of normal natural circulation flow were identified. Finally, a core heatup occurred at a low core water level, although under a significant amount of PZR inventory, whose drainage seemed to be hindered owing to the pressurizer function by the RV. The transient of SBO-01 is well reproduced in the calculation using the MARS code.

Motion behavior research of liquid micro-particles filtration at various locations in a rotational flow field

  • Yan, Yan;Lin, Yuanzai;Cheng, Jie;Ni, Zhonghua
    • Structural Engineering and Mechanics
    • /
    • 제62권2호
    • /
    • pp.163-170
    • /
    • 2017
  • This study presents a particle-wall filtration model for predicting the particle motion behavior in a typical rotational flow field-filtration in blower system of cooker hood. Based on computational fluid dynamics model, air flow and particles has been simulated by Lagrangian-particle/ Eulerian-gas approaches and get verified by experiment data from a manufacturer. Airflow volume, particle diameter and local structure, which are related to the particle filtration has been studied. Results indicates that: (1) there exists an optimal airflow volume of $1243m^3/h$ related to the most appropriate filtration rate; (2) Diameter of particle is the significant property related to the filtration rate. Big size particles can represent the filtration performance of blower; (3) More than 86% grease particles are caught by impeller blades firstly, and then splashed onto the corresponding location of worm box internal wall. These results would help to study the micro-particle motion behavior and evaluate the filtration rate and structure design of blower.

CATHARE2와 RELAP5/MOD3를 이용한 BETHSY 6.2 TC 소형 냉각재상실사고 실험결과의 해석 (Comparison Of CATHARE2 And RELAP5/MOD3 Predictions On The BETHSY 6.2% TC Small-Break Loss-Of-Coolant Experiment)

  • Chung, Young-Jong;Jeong, Jae-Jun;Chang, Won-Pyo;Kim, Dong-Su
    • Nuclear Engineering and Technology
    • /
    • 제26권1호
    • /
    • pp.126-139
    • /
    • 1994
  • 본 연구에서는 BETHSY 실험장치에서 수행한 6" 소형 냉각재 상실사고(LOCA) 실험을 최적 열수력 코드인 CATHARE2 V1.2와 RELAP5/MOD3를 이용하여 계산했다. 본 연구의 주 목적은 소형 LOCA시 관심을 가지는 주요 물리현상인 이상 임계유동, 감압과정, 노심수위 감소, loop seal clearing 등에 대한 두 코드의 소형 LOCA 계산모의능력을 평가하는 것이다. 두코드는 이상 유동현상의 전개 경향이나 발생시점을 비교적 잘 예측하는 것으로 나타났고, CATHARE2의 경우가 실험과 더 잘 일치했다. 그렇지만 두 코드는 loop seal clearing 현상, loop seal clearing 발생후의 노심수위, accumulator 유량거동 등의 예측에는 약간의 편차를 보였는데, 편차의 정도는 RELAP5가 CATHARE2보다 더 큰 것으로 나타났다. 두 코드의 편차요인을 보다 상세히 분석하기 위하여 계면 마찰력, mesh크기, 파단노즐 junction에서의 방출계수(Discharge coefficient)등에 대하여 민감도분석을 수행하였다. 그 결과 CATHARE2의 경우는 계면 마찰력을 증가시킴으로써 감압과정시 일차계통의 질량분포, 즉 증기 발생기 입구 공동(SG inlet plenum)에서의 차압과 Cross√er leg의 차압이 개선되었으며, 증기발생기 외측 열전달계수를 증가시킴으로써 중기발생기의 압력변화를 개선할 수 있었다. RELAP5의 경우는 어떤 하나의 입력변수를 변화시켜서 과도기의 결과를 개선할 수 없었으며 다만, 계면 마찰력 모델링에 여전히 많은 불화실성이 내포되어 있음을 확인했다.확인했다.

  • PDF

Effect of pH on Phase Separated Anaerobic Digestion

  • Jung, Jin-Young;Lee, Sang-Min;Shin, Pyong-Kyun;Chung, Yun-Chul
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제5권6호
    • /
    • pp.456-459
    • /
    • 2000
  • A pilot scale experiment was performed for a year to develop a two-phase anaerobic process for piggery wastewater treatment (COD: 6,000mg/L, BOD: 4,000mg/L, SS: 500mg/L, pH 8.4, alkalinity 6,000mg/L). The acidogenic reactor had a total volume of 3㎥, and the methanogenic reactor, an anaerobic up-flow sludge filter, combining a filter and a sludge bed, was also of total volume 3㎥(1.5㎥ of upper packing material). Temperatures of the acidogenic and methanogenic reactors kept at 20$^{\circ}C$ and 35$^{\circ}C$, respectively. When the pH of the acidogenic reactor was controlled at 6.0-7.0 with HCl, the COD removal efficiency increased from 50 to 80% over a period of six months, and as a result, the COD of the final effluent fell in the range of 1,000-1,500 mg/L. BOD removal efficiency over the same period was above 90%, and 300 to 400 mg/L was maintained in the final effluent. The average SS in the final effluent was 270 mg/L. The methane production was 0.32㎥ CH$_4$/kg COD(sub)removed and methane content of the methanogenic reactor was high value at 80-90%. When the pH of the acidogenic reactor was not controlled over the final two months, the pH reached 8.2 and acid conversion decreased compared with that of pH controlled, while COD removal was similar to the pH controlled operation. Without pH control, the methane content in the gas from methanogenic reactor improved to 90%, compared to 80% with pH control.

  • PDF

낮은 경사각을 갖는 밀폐형 2상 열사이폰의 열전달 특성에 관한 연구 (A Study on Heat Transfer Characteristics of a Closed Two-Phase Thermosyphon with a Low Tilt Angle)

  • 김철주;강환국;김윤철
    • 설비공학논문집
    • /
    • 제8권1호
    • /
    • pp.1-12
    • /
    • 1996
  • In lots of application to heat exchanger systems, closed two-phase thermosyphons are tilted from a horizontal. If the tilt angle, especially, is less than 30$^{\circ}$, the operational performances of thermosyphon are highly dependent on tilt angle. The present study was conducted to better understand such operational behaviors as mech-anni는 of phase change, and flow patterns inside a tilted thermosyphon. For experiment, an ethanol thermosyphon with a 35% of fill charge rate was designed and manufactured, using a copper tube with a diameter 19mm and a length 1500mm. Through a series of test, the tilt angle was kept constant at each of 4 different values in the range 10~25deg. and the heat supply to the evaporator was stepwisely increased up to 30㎾/$m^2$. When a steady state was established to the thermosyphon for each step of thermal loads, the wall temperature distribution and vapor temperature at the condenser were measured. The wall temperature distributions demonstrated a formation of dry patch in the top end zone of the evaporator, with a values of temperature 20~4$0^{\circ}C$ higher than the wetted surface for a moderate heat flux q≒20㎾/$m^2$. Inspite of the presence of hot dry patch, however, the mean values of boiling heat transfer coefficient at the evaporator wall were still in a good agreement with those predicted by Rohsenow's formula, which was based on nucleate boiling. For the condenser, the wall temperatures were practically uniform, and the measured values of condensation heat transfer coefficient were 1.7 times higher than the predicted values obtained from Nusselt's film condensation theory on tilted plate. Using those two expressions, a correlation was formulated as a function of heat flux and tilt angle, to determine the total thermal resistance of a tilted thermosyphon. The correlation formula showed a good agreement with the experimental data within 20%.

  • PDF