• Title/Summary/Keyword: Two-Phase

Search Result 9,547, Processing Time 0.037 seconds

Two Low-Loss Large Current Rectifiers Based on Low KVA Rating Wye-Connected Autotransformers

  • Meng, Fangang;Man, Zhongcheng;Li, Quanhui;Gao, Lei
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1697-1707
    • /
    • 2018
  • In this paper, two large current rectifiers are proposed based on two wye-connected autotransformers. The requirements of the ideal large current rectifier are analyzed, and it is concluded that the large current rectifier has a higher power density and a higher energy conversion efficiency when it is made up of two three-phase half-wave rectifiers and a wye-connected autotransformer. According to theoretical analysis results, the two novel wye-connected autotransformers are designed to feed two three-phase half-wave rectifiers. The two autotransformers can generate two groups of three-phase voltages with a 60o phase shifting, and their kVA ratings account for 95% and 80% of the load power, respectively. These values are less than those of a double star rectifier at 30% and 46%. From the input mains and output side, the power quality of the proposed rectifiers is the same as that of the double star rectifier. Some experiments validate the correctness of the theoretical analysis.

Recalibration Estimation for Unit Nonresponse at the Two Levels Auxiliary Information

  • Yum, Joon Keun;Son, Chang Kyoon;Jeung, Young Mee
    • Communications for Statistical Applications and Methods
    • /
    • v.10 no.3
    • /
    • pp.665-678
    • /
    • 2003
  • In this paper we suggest the new calibration estimator, which is called to the recalibration estimator, and its variance estimator using two-phase sampling technique according to the auxiliary information having strong correlation with the variable of interest under the unit nonresponse. In this unit nonresponse situation, an available information may exists at the level of whole population or the first-phase sample. The proposed recalibration estimator derives from the first and second phase weights respectively.

Cogging Force Reduction of Two Phase Linear Hybrid Stepping Motor (2상 선형 하이브리드 스테핑 전동기의 코깅 리플 저감)

  • Hwarg, Tai-Sik;Seok, Jul-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.96-98
    • /
    • 2005
  • This paper presents a new two-phase linear hybrid stepping motors (LHSM), which has two windings per phase and one of them shares the other phase winding. The proposed motor shows a unique ability to deliver low cogging force without any particular complex control scheme and additional power electronics hardware in micro stepping control. An analytical and experimental comparison between conventional and proposed LHSM is evaluated to confirm the effectiveness of the proposed design.

  • PDF

Induction Motor Speed Control System using Two Phase SRPP-PWM Scheme (2상 SRPP-PWM 기법을 사용한 유도모터 속도제어 시스템)

  • Wi Seog-Oh;Kim Jung-Kun;Lim Young-Cheol;Jung Young-Gook
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.25-28
    • /
    • 2002
  • In this paper, 2 phase modulated SRPP-PWM(Separately Random Pulse Position PWM) is proposed. This PWM technique is based on the 2 phase modulated SVPWM(Space Vector Pulse Width Modulation). In according to the theory of SVPWM, 2 phase modulated SVPWM uses two pulses, not three pulses as in 3 phase modulated SVPWM. In the proposed SRPP-PWM scheme, each of two phase pulses is located randomly in each switching interval. The experimental results show that the voltage and switching noise harmonics are spread to a wide band area. Also, the performance of the proposed 2 phase modulated SRPP-PWM and the conventional SVPWM are compared to each other In result, the speed response is nearly similar to each other from the viewpoint of the v/f constant control.

  • PDF

Phase error compensation for three-dimensional shape measurement based on a phase-shifting method (위상천이법을 이용한 삼차원 형상측정에서 위상오차 보정)

  • Park, Yoon-Chang;Ahn, Seong-Joon;Kang, Moon-Ho;Kwon, Young-Chul;Ahn, Seung-Joon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3023-3030
    • /
    • 2009
  • In this paper, a prediction and compensation method for the error in the phase measured by using the proportionality between two wavelengths in the TW-PMP (Two-wavelength Phase Measuring Profilometry) is proposed and experimental results are shown to verify the usefulness of the proposed method. For sample object, firstly, a phase-shifting with a quite large number of steps is adopted in measurement, compared with the conventional phase-shifting method, secondly, a 3-3 step phase-shifting method is used to measure the same object which is applied to high-speed 3D shape measurement, and then, measured results from these two phase-shifting methods are compared to calculate measurement noises. From the experimental results applying the proposed compensation method to the measured beat phase and absolute phase, it has proven that noises are decreased by 90% and 17.2% for each case.

Two-Switch Auxiliary Resonant DC Link Snubber-Assisted Three-Phase Soft Switching PWM Sinewave Power Conversion System with Minimized Commutation Power Losses

  • Nagai, Shinichiro;Sato, Shinji;Ahmed, Tarek;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.249-258
    • /
    • 2003
  • This paper presents a high-efficient and cost effective three-phase AC/DC-DC/AC power conversion system with a single two-switch type active Auxiliary Resonant DC Link (ARDCL) snubber circuit, which can minimize the total power dissipation. The active ARDCL snubber circuit is proposed in this paper and its unique features are described. Its operation principle in steady-state is discussed for the three phase AC/DC-DC/AC converter, which is composed of PWM rectifier as power factor correction (PFC) converter, sinewave PWM inverter. In the presented power converter system not only three-phase AC/DC PWM rectifier but also three-phase DC/AC inverter can achieve the stable ZVS commutation for all the power semiconductor devices. It is proved that the proposed three-phase AC/DC-DC/AC converter system is more effective and acceptable than the previous from the cost viewpoint and high efficient consideration. In addition, the proposed two-switch type active auxiliary ARDCL snubber circuit can reduce the peak value of the resonant inductor injection current in order to maximize total system actual efficiency by using the improved DSP based control scheme. Moreover the proposed active auxiliary two-switch ARDCL snubber circuit has the merit so that there is no need to use any sensing devices to detect the voltage and current in the ARDCL sunbber circuit for realizing soft-switching operation. This three-phase AC/DC-DC/AC converter system developed for UPS can achieve the 1.8% higher efficiency and 20dB lower conduction noise than those of the conventional three-phase hard-switching PWM AC/DC-DC/AC converter system. It is proved that actual efficiency of the proposed three-phase AC/DC-DC/AC converter system operating under a condition of soft switching is 88.7% under 10kw output power.

Development of Light Transmission Fluctuation for Particle Measurement in Solid-Gas Two Phase Flows

  • YANG, Bin;WANG, Zhan-ping;HE, Yuan;CAI, Xiao-Shu
    • Particle and aerosol research
    • /
    • v.12 no.1
    • /
    • pp.21-26
    • /
    • 2016
  • In order to realize In-line and convenient measurement for solid-gas two phase flows, Light Transmission Fluctuation (LTF) based on the random variation of transmitted light intensity, light scattering theory and cross-correlation method was presented for online measurement of particle size, concentration and velocity. The statistical relationship among transmitted light intensity, particle size and particle number in measurement zone was described by Beer-Lambert Law. Accordingly, the particle size and concentration were determined from the fluctuation signal of transmitted light intensity. Simultaneously, the particle velocity was calculated by cross-correlation analysis of two neighboring light beams. By considering the influence of concentration variation in industrial applications, the improved algorithm based on spectral analysis of transmitted light intensity was proposed to improve measurement accuracy and stability. Therefore, the online measurement system based on LTF was developed and applied to measure pulverized coal in power station and raw material in cement plant. The particle size, concentration and velocity of powder were monitored in real-time. It can provide important references for optimal control, energy saving and emission reduction of energy-intensive industries.

Improved Convective Heat Transfer Correlations for Two-Phase Two-Component Pipe Flow

  • Kim, Dongwoo
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.403-422
    • /
    • 2002
  • In this study, six two-phase nonboiling heat transfer correlations obtained from the recommendations of our previous work were assessed. These correlations were modified using seven extensive sets of two-phase flow experimental data available from the literature, for vertical and horizontal tubes and different flow patterns and fluids. A total of 524 data points from five available experimental studies (which included the seven sets of data) were used for improvement of the six identified correlations. Based on the tabulated and graphical results of the comparisons between the predictions of the modified heat transfer correlations and the available experimental data, appropriate improved correlations for different flow patterns, tube orientations, and liquid-gas combinations were recommended.

Cavitating Flow Simulation Using Two-Fluid Two-Phase Flow Model and HLL Scheme (이유체 이상유동 모델과 HLL 스킴을 이용한 캐비테이션 유동 해석)

  • Yeom Geum-Su;Chang Keun-Shik
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.219-222
    • /
    • 2005
  • A compressible two-fluid two-phase flow computation model using the stiffened-gas equation of state is formulated. Since the conservation equation system is of mixed type, it gives complex eigenvalues. The sonic speeds obtained from the individual single phase have been simply used in the literature for the fastest wave speeds necessary in the HLL scheme. This method has worked fine but proved to be quite diffusive according to our test. To improve the accuracy, we here propose to utilize the analytic eigenvalues evaluated from an approximate Jacobian matrix lot the fastest wave speeds. The interfacial transfer terms were dropped in constituting the Jacobian matrix for this purpose. The present scheme proved efficient, robust and accurate in comparison with other existing methods. We solved the cavitating flow problem using the present scheme. The result shows more detailed wave structure in the cavitating process caused by the strong expansion waves.

  • PDF