• 제목/요약/키워드: Two stage operation

검색결과 571건 처리시간 0.028초

Performance and Parameter Comparison between single stage and Two-Stage Compression/Absorption Heat Pump System (단단 및 2단 압축/흡수 히트펌스시스템의 성능 및 중요인자비교 분석)

  • Tian, Huaizhang;Park, Seong-Ryong
    • Proceedings of the SAREK Conference
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.451-456
    • /
    • 2005
  • The mathematical model for the heat exchangers of absorber and desorber is made in the elementary control volume method and the thermodynamic properties of working fluid. water/ammonia mixture. are calculated by some fundamental subroutines in RefProp 7.0 and flash subroutines made by authors The simulation results show that two-stage cycle has higher COP than single stage if temperature lift is high: the performance of single stage compression cycle can be improved by increase of absorber pressure. but the performance of two-stage compression cycle can not be improved in this way : the compressor discharging temperature of two-stage compression is much lower than that of single stage cycle. which is very important to the safety operation of CA heat pump. Major parameter comparison between the cycles at their optimal configurations is also given.

  • PDF

Esophageal Perforation due to Air-gun Shut Injury - A Report of Case - (총상에 의한 식도천공 치험 1례)

  • 전예지
    • Journal of Chest Surgery
    • /
    • 제22권2호
    • /
    • pp.342-347
    • /
    • 1989
  • A 4-year-old male developed the esophageal perforation after air-gun shut injury in the thorax. The esophageal perforation was found on esophagogram at the next day after the accident. Because of delayed diagnosis, mediastinitis and pyopneumothorax were developed. The general conditions of the patient were very critical with sepsis on admission. Therefore, two staged operation was planned. At the first stage, exclusion and diversion of the esophagus was carried out to treat chemical pneumonitis due to gastric contents through the esophago-bronchial fistula by gastroesophageal reflux. Clinical conditions of the patient were improved after the first stage operation. At the second stage, the esophageal reconstruction with right colon was performed.

  • PDF

A Study on ESS Optimal Operation Strategy Using Two Stage Hybrid Optimization (Two Stage Hybrid Optimization을 사용한 ESS 최적 운전 전략에 대한 연구)

  • Gong, Eun-Kyoung;Sohn, Jin-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제67권7호
    • /
    • pp.833-839
    • /
    • 2018
  • This paper presents an analysis and the methodology of optimal operation strategy of the ESS(Energy Storage System) for reduce electricity charges. Electricity charges consist of a basic charge based on the contract capacity and energy charge according to the power usage. In order to use electrical energy at minimal charge, these two factors are required to be reduced at the same time. QP(Quadratic Programming) is appropriate for minimization of the basic charge and LP(Linear Programmin) is adequate to minimize the energy charge. However, the integer variable have to be introduced for modelling of different charge and discharge efficiency of ESS PCS(Power Conversion System), where MILP(Mixed Integer Linear Programming) can be used. In this case, the extent to which the peak load savings is accomplished should be assumed before the energy charge is minimized. So, to minimize the electricity charge exactly, optimization is sequentially performed in this paper, so-called the Two Stage Hybird optimization, where the extent to which the peak load savings is firstly accomplished through optimization of basic charge and then the optimization of energy charge is performed with different charge and discharge efficiency of ESS PCS. Finally, the proposed method is analyzed quantitatively with other optimization methods.

Direct Seek Control for Swing-arm Type Dual Stage Actuators in Blu-Ray Disc Drive Systems

  • Ryu, Shi-Yang;Jung, Soo-Yul;Yoon, Hyeong-Deok;Park, In-Shik
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.735-739
    • /
    • 2003
  • This paper presents a direct seek control algorithm for swing-arm type dual stage servo system that consists of a coarse actuator and a fine actuator. The proposed scheme is to design a control system that attenuates the effect of dynamic coupling between the two actuators so that the seek operation can be performed in a single-shot with stability. In an optical drive system with dual stage servo mechanism, the effect of dynamic coupling between the two actuators needs to be handled during the coarse seek operation due to its inherent structure. In an extreme case, the two actuators can collide each other, which leads to critical degradation of the seek performance. To handle this problem, our proposed control scheme is to generate the drive signals such that the two actuators behave as if they are a single fixed body. To this end, a feedforward controller and two feedback controllers are designed that enable the current drive system perform wide range of track seek. Simulation results are provided to show the validity and feasibility of our proposed algorithm.

  • PDF

Operation of a High-T$_c$ Rapid Single-Flux-Quantum 4-stage Shift Register

  • Park, J.H.;Kim, Y.H.;Kang, J.H.;Hahn, T.S.;Kim, C.H.;Lee, J.M.
    • Progress in Superconductivity
    • /
    • 제1권2호
    • /
    • pp.105-109
    • /
    • 2000
  • We have designed and fabricated a single-flux-quantum(SFQ) four-stage shift register using YBCO bicrystal Josephson junctions, and tested its operations using a digital measurement set-up. The circuit consists of 4 shift register stages and a read SQUID placed next to each side of the shift register. Each SQUID was inductively coupled to the nearby shift register stage. The major obstacle in testing the circuits was the interference between the two read SQUIDs, and we could get over the problem by determining the correct operation points of the SQUID from the simultaneously measured modulation curves. Loaded data ('1' or '0') were successfully shifted from a stage to the next by a controlled current pulse injected to the bias lines located between the stages, and the corresponding correct data shifts were observed with the two read SQUIDs.

  • PDF

Short-term Results of Surgical Treatment in Esophageal Carcinoma (식도암의 외괴적 조기관찰 성적)

  • 오봉석
    • Journal of Chest Surgery
    • /
    • 제25권4호
    • /
    • pp.398-405
    • /
    • 1992
  • Twenty nine adult patients underwent surgical esohpagectomy and one, bypass procedure for documented carcinoma of esophagus and cadiac portion of stomach at Chonnam National University Hospital from Jan 1986 to April 1991. There were several kinds of esophagectomies including through transhiatal, left thoracotomy only, laparotomy and thoracotomy, and laparotomy and right thoracotomy and cervical incision. Twenty five and squamous cell carcinoma and 5, adenocarcinoma. The tumor locations were the upper third in 3, middle third in 12, lower third in 10 and cardiac portion of stomach in 5. After operation, 8[27%] patients were classified in Stage IIa, 6[20%] patients in Stage IIb, 15 patients[50%] in Stage III and one patient in Stage IV. Major postoperative complications included anastomotic narrowing in 3, limited suture line leak in 2, wound infection in 2, hoarseness in 2, pseudomembraneous enterocolitis in 1 and herpes zoster in 1. There was no death within 30 days of operation. Ten months survival was 100% for patients with Stage lIa, 67% for patients with Stage IIb, 50% for patients with Stage III. Furthermore, 20 months survival was 75% in IIIa, 33% in IIb, and 40% in III. But there were no significant differences in survivals among the stage. The actuarial survival is 58% at one year and 41% at two years, The periods of average survival is 589 days after operation.

  • PDF

Effects of Polyurethane as Support Material for the Methanogenic Digester of a Two-Stage Anaerobic Wastewater Digestion System

  • Woo, Kyung-Soo;Yang, Han-Chul;Lim, Wang-Jin
    • Journal of Microbiology and Biotechnology
    • /
    • 제12권1호
    • /
    • pp.14-17
    • /
    • 2002
  • To increase the efficiency of a two-stage anaerobic wastewater digestion system, various polymers were added to the methanogenic reactor as supports. The addition of polyurethane addition (6%, w/v) to the methanogenic reactor facilitated the organic loading rate (2-day Hydraulic Retention Time), higher than that of the conventional methanogenic reactor (6-day HRT). During the operation of the polyurethane-added reactor, a significant decrease in the organic mass in the effluent (COD 5-6 kg/l) was achieved, compared to that of the conventional reactor (COD 15-20 kg/l). The methane gas production rate also improved about 3-fold in the polyurethane-added reactor. More biomass was found to accumulate in the polyurethane-liquid phase (volatile solid, 26-28kg) than in the free-liquid phase (volatile solid, 5- 7 kg/l) after 90 days of operation. A scaled-up experiment with a polyurethane-added 2.5-1 reactor confirmed the previous results, and no adverse effects such as plugging or channeling due to decreased efficiency was observed even after 4 months of operation.

Improved Optimization of Indirubin Production from Bioreactor Culture of Polygonum tinctorium

  • Chung, Choong Sik;Kim, Kyung Il;Bae, Geun Won;Lee, Youn Hyung;Lee, Hyong Joo;Chae, Young Am;Chung, In Sik
    • Journal of Applied Biological Chemistry
    • /
    • 제43권2호
    • /
    • pp.109-111
    • /
    • 2000
  • Effect of the two-stage operation and cell concentration on indirubin production was investigated using bioreactor culture of Polygonum tinctorium. Two-stage culture was operated successfully for 110 days without any adverse effects on continuous indirubin production. Maximum indirubin concentration was found to be at 80 mg/bioreactor. Initial cell concentration significantly affected indirubin production. The indirubin production at 29.2% PCV was improved by 845%, compared to that at 5% PCV. For high-density bioreactor culture of P. tinctorium, a maximum production rate of 10.2 mg indirubin/L day was obtained. Indirubin recovery for bioreactor operation was also examined using XAD-2, XAD-4, XAD-7, and solid silicon. XAD-4 was 1.6-fold more effective than that for solid silicon in indirubin recovery.

  • PDF

Analysis of Hybrid Converter with Wide Voltage Range Operation

  • Lin, Bor-Ren
    • Journal of Power Electronics
    • /
    • 제19권5호
    • /
    • pp.1099-1107
    • /
    • 2019
  • A soft switching converter with wide voltage range operation is investigated in this paper. A series resonant converter is implemented to achieve a high circuit efficiency with soft switching characteristics on power switches and rectifier diodes. To improve the weakness of the narrow voltage range in LLC converters, an alternating current (ac) power switch is used on the primary side to select a half-bridge or full-bridge resonant circuit to implement 4:1 voltage range operation. On the secondary-side, another ac power switch is adopted to select a full-wave rectifier or voltage-doubler rectifier to achiever an additional 2:1 output voltage range. Therefore, the proposed resonant converter has the capacity for 8:1 (320V~40V) wide output voltage operation. A single-stage hybrid resonant converter is employed in the study circuit instead of a two-stage dc converter to achiever wide voltage range operation. As a result, the study converter has better converter efficiency. The theoretical analysis and circuit characteristics are verified by experiments with a prototype circuit.

A Case Report of Acquired Nonmalignant Tracheoesophageal Fistula (후천성 비종양성 기관식도루;수술 치험1례)

  • 윤정섭
    • Journal of Chest Surgery
    • /
    • 제25권8호
    • /
    • pp.800-805
    • /
    • 1992
  • Acquired, nonmalignant tracheoesophageal fistula is an uncommom and difficult problem to manage. The most commom cause is a complication of endotracheal or tracheostomy tubes. Most are diagnosed while patients still require mechanical ventilation. The principle of treatment is two stage operation. First, new tracheostomy tube is placed so that the baloon is below the fistula, and gastrostomy and feeding jejunostomy are made for the drainage and feeding. Finally after weaning from the mechanical ventilation, tracheal resection and reconstruction are made, and the esophageal defect is closed in two layers and a viable strap muscle interposed into the two suture site to prevent recurrence. Recently, we experienced a case of acquired nonmalignant tracheoesophageal fistula which was developed during mechanical ventilation. She was successfully treated with the above two stage operation.

  • PDF