• 제목/요약/키워드: Two resonant tanks

검색결과 14건 처리시간 0.017초

이물 낙하법에 의한 GIS 초음파 진단 기술 연구 (A Study on the Technology to Diagnose GIS with Acoustic Emission by Dropping Particles Method)

  • 김광화;최재구;선종호;김익수;윤진열;박기준
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권6호
    • /
    • pp.246-252
    • /
    • 2002
  • This paper describes the acoustic emission measurement method to diagnose GIS for particles. We measured and analyzed the signals of acoustic waves using acoustic two types sensors with 125KHz and 50KHz resonant frequency respectively when the particles were dropped on the surfaces of circular plates and inside of GlS tanks. We found that the difference between peak outputs of two sensors depended on the types and materials of particles and the conditions of dropping position. These results showed that the outputs of 125KHz sensor were higher than those of 50KHz sensor in circular plate and 362㎸ GIS tank made of steel and vice versa in circular plate and 800㎸ GIS tank made of aluminum. The ratios outputs of 125KHz sensor to those of 50KHz sensor were 1.4 - 2.37 in 800㎸ GIS tank and were 0.5 - 1.0 in 362㎸ GIS tank. Therefore we knew that adaption of two types acoustic sensors which had different resonant frequencies as a very useful method in diagnosis of GIS.

Concept Design of a Parallel-type Tuned Mass Damper - Tuned Sloshing Damper System for Building Motion Control in Wind

  • Lee, Chien-Shen;Love, J. Shayne;Haskett, Trevor C.;Robinson, Jamieson K.
    • 국제초고층학회논문집
    • /
    • 제10권2호
    • /
    • pp.93-97
    • /
    • 2021
  • Supplementary damping systems, such as tuned mass dampers (TMDs) and tuned sloshing dampers (TSDs) - also known as tuned liquid dampers (TLDs) - have been successfully employed to reduce building motion during wind events. A design of a damping system consisting of a TMD and two TSDs performing in unison has been developed for a tall building in Taiwan to reduce wind-induced motion. The architecturally exposed TMD will also be featured as a tourist attraction. The dual-purpose TSD tanks will perform as fire suppression water storage tanks. Linearized equivalent mechanical TSD and TMD models are coupled to the structure to simulate the multi-degree of freedom system response. Frequency response curves for the structure with and without the damping system are created to evaluate the performance of the damping system. The performance of the combined TMD-TSD system is evaluated against a conventional TMD system by computing the effective damping produced by each system. The proposed system is found to have superior performance in acceleration reduction. The combined TMD-TSD system is an effective and affordable means to reduce the wind-induced resonant response of tall buildings.

주파수특성이 다른 2개의 초음파 친서에 의한 GIS 이물진단 기술 연구 (A Study on the Technology Diagnosing Particles with Two Acoustic Emission Sensors Which have the Different Characteristics of Frequency in GIS)

  • 김광화;최재구;선종호;김익수;윤진열
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권5호
    • /
    • pp.219-225
    • /
    • 2003
  • This paper described about the acoustic wave measurement method to diagnose GIS for particles. We measured and analyzed the signals of acoustic waves with two type acoustic sensors having 125kHz and 50kHz resonant frequency respectively when the particles were bounced on the inside surfaces of GIS tanks by the electrostatic force. To use two sensors for the diagnosis of GIS, we set up the calibration method for this measurement method. We showed the output characteristics of two sensors according to the sizes and materials of particles in the experiment. As the results, the inception voltages bouncing particles depended on the materials and the extinction voltages bouncing them depended on the sizes and materials. We found out that the relationship between sizes of particles and output voltages of sensors didn't have linearity but the ratios of between peak values of two sensors depended on the materials of GIS enclosures and the sizes of particles.

주파수특성이 다른 2개의 초음파 친서에 의한 GIS 이물진단 기술 연구 (A Study on the Technology Diagnosing Particles with Two Acoustic Emission Sensors Which have the Different Characteristics of Frequency in GIS)

  • 김광화;최재구;선종호;김익수;윤진열
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제52권5호
    • /
    • pp.219-219
    • /
    • 2003
  • This paper described about the acoustic wave measurement method to diagnose GIS for particles. We measured and analyzed the signals of acoustic waves with two type acoustic sensors having 125kHz and 50kHz resonant frequency respectively when the particles were bounced on the inside surfaces of GIS tanks by the electrostatic force. To use two sensors for the diagnosis of GIS, we set up the calibration method for this measurement method. We showed the output characteristics of two sensors according to the sizes and materials of particles in the experiment. As the results, the inception voltages bouncing particles depended on the materials and the extinction voltages bouncing them depended on the sizes and materials. We found out that the relationship between sizes of particles and output voltages of sensors didn′t have linearity but the ratios of between peak values of two sensors depended on the materials of GIS enclosures and the sizes of particles.