• Title/Summary/Keyword: Two dimensional tissue model

Search Result 41, Processing Time 0.026 seconds

Validity of Three-dimensional Facial Scan Taken with Facial Scanner and Digital Photo Wrapping on the Cone-beam Computed Tomography: Comparison of Soft Tissue Parameters

  • Aljawad, Hussein;Lee, Kyungmin Clara
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.19-30
    • /
    • 2022
  • Purpose: The purpose of the study was to assess the validity of three-dimensional (3D) facial scan taken with facial scanner and digital photo wrapping on the cone-beam computed tomography (CBCT). Materials and Methods: Twenty-five patients had their CBCT scan, two-dimensional (2D) standardized frontal photographs and 3D facial scan obtained on the same day. The facial scans were taken with a facial scanner in an upright position. The 2D standardized frontal photographs were taken at a fixed distance from patients using a camera fixed to a cephalometric apparatus. The 2D integrated facial models were created using digital photo wrapping of frontal photographs on the corresponding CBCT images. The 3D integrated facial models were created using the integration process of 3D facial scans on the CBCT images. On the integrated facial models, sixteen soft tissue landmarks were identified, and the vertical, horizontal, oblique and angular distances between soft tissue landmarks were compared among the 2D facial models and 3D facial models, and CBCT images. Result: The results showed no significant differences of linear and angular measurements among CBCT images, 2D and 3D facial models except for Se-Sn vertical linear measurement which showed significant difference for the 3D facial models. The Bland-Altman plots showed that all measurements were within the limit of agreement. For 3D facial model, all Bland-Altman plots showed that systematic bias was less than 2.0 mm and 2.0° except for Se-Sn linear vertical measurement. For 2D facial model, the Bland-Altman plots of 6 out of 11 of the angular measurements showed systematic bias of more than 2.0°. Conclusion: The facial scan taken with facial scanner showed a clinically acceptable performance. The digital 2D photo wrapping has limitations in clinical use compared to 3D facial scans.

Analysis of Thermal Relaxation Time of Tissues Subject to Pulsed Laser Irradiation (초단파 레이저 조사시 티슈 열완화 시간 분석)

  • Kim, Kyung-Han;Lee, Jae-Hoon;Suh, Jeong
    • Laser Solutions
    • /
    • v.12 no.2
    • /
    • pp.17-25
    • /
    • 2009
  • Two methodologies for predicting thermal relaxation time of tissue subjected to pulsed laser irradiation is introduced by the calculation the optical penetration depth and by the investigation of the temperature diffusion behavior. First approach is that both x-axial and y-axial thermal relaxation times are predicted and they are superposed to achieve the thermal relaxation time (${\tau}_1$) for two-dimensional square tissue model. Another approach to achieve thermal relaxation time (${\tau}_2$) is measuring the time required for local temperature drop until $e^{-1}$ of the maximum laser induced heating.

  • PDF

A Novel Model for Smart Breast Cancer Detection in Thermogram Images

  • Kazerouni, Iman Abaspur;Zadeh, Hossein Ghayoumi;Haddadnia, Javad
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.24
    • /
    • pp.10573-10576
    • /
    • 2015
  • Background: Accuracy in feature extraction is an important factor in image classification and retrieval. In this paper, a breast tissue density classification and image retrieval model is introduced for breast cancer detection based on thermographic images. The new method of thermographic image analysis for automated detection of high tumor risk areas, based on two-directional two-dimensional principal component analysis technique for feature extraction, and a support vector machine for thermographic image retrieval was tested on 400 images. The sensitivity and specificity of the model are 100% and 98%, respectively.

Cytokine Release from Organotypic Human Oral Tissue Following Exposure to Oral Care Product Chemicals

  • Yang, Song-Yi;Piao, Yin-Zhu;Kim, Kwang-Mahn;Kwon, Jae-Sung
    • Journal of Korean Dental Science
    • /
    • v.14 no.2
    • /
    • pp.51-60
    • /
    • 2021
  • Purpose: Measuring viability of a three-dimensional in vitro organotypic human oral tissue model has been suggested as an alternative test method to the oral mucosa irritation test of oral care products. The aim of this study was to investigate the production of two different cytokines using organotypic human oral tissue model following exposure to chemicals that are commonly used in oral care products. Materials and Methods: The organotypic human oral tissues were exposed to ethanol, sodium lauryl sulphate or hydrogen peroxide for 90 minutes. Following exposure, interleukin (IL)-1α and IL-8 productions were assessed and correlated with cell viability testing as well as histology of the organotypic human oral tissues. Result: High levels of IL-8 were released from organotypic human oral tissues in all of the test and control groups without any significant differences between them. In contrast, differences were found in IL-1α release between the test and control groups. Additionally, the trend of IL-1α release corresponded to the phenotypes observed in histological analysis while different trend existed between IL-1α release and cell viability. Conclusion: The study concluded the non-specific release of IL-8 for the assessment of oral care product chemicals' toxicity, while potential of measuring IL-1α cytokine level as the possible alternative test method.

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF MANDIBULAR STRESSES UNDER COMPLETE DENTURES WITH VARIANT ARTIFICIAL TEETH FORMS AND OCCLUSAL PATTERNS (총의치 교합면 형태가 하악골 응력 분포에 미치는 영향에 관한 삼차원 유한요소분석적 연구)

  • Lee Cheol-Gyu;Kim Chang-Whe;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.3
    • /
    • pp.351-384
    • /
    • 1993
  • Complete denture occlusion must be developed to function efficiently and with the least amount of trauma to the supporting tissues. For the preservation of supporting tissues, it is imperative to reduce to a minimum the functional stress induced by dentures. The magnitude of the horizontal component of functional stress contributed by various occlusal teeth forms has not been studied. This study was aimed to investigate the influence of different occlusal teeth forms on the mode of distribution of the stresses in the mandibular tissue, and the displacement of lower dentures during the variant functional movement of mandible for this study three dimensional finite element analysis was used. FEM models were created using commercial software Super Sap for IBM 32 bit computer. The model was composed of 3380 brick elements and 4346 nodes. The results were as follows. 1. The magnitude of stress was similar between two models in centric occlusion, in the case of anatomic model, the stress was concentrated on the buccal side of alveolar ridge beneath the bicuspids. 2. During the protrusive movement, the increasing of stress from the posterior to anterior part of mandible was seen in the case of anatomic model. 3. During the lateral movement, the stress of anatomic model was greater than that of nonanatomic model. 4. The stress of anatomic model was concentrated on the anterior region of residual ridge during the lateral movement. 5. In the case of anatomic model the anterior part of denture was displaced severely at the centric and lateral position, but the denture of nonanatomic model was displaced minutely at the protrusive and lateral position.

  • PDF

Guidelines for Manufacturing and Application of Organoids: Brain

  • Taehwan Kwak;Si-Hyung Park;Siyoung Lee;Yujeong Shin;Ki-Jun Yoon;Seung-Woo Cho;Jong-Chan Park;Seung-Ho Yang;Heeyeong Cho;Heh-In Im;Sun-Ju Ahn;Woong Sun;Ji Hun Yang
    • International Journal of Stem Cells
    • /
    • v.17 no.2
    • /
    • pp.158-181
    • /
    • 2024
  • This study offers a comprehensive overview of brain organoids for researchers. It combines expert opinions with technical summaries on organoid definitions, characteristics, culture methods, and quality control. This approach aims to enhance the utilization of brain organoids in research. Brain organoids, as three-dimensional human cell models mimicking the nervous system, hold immense promise for studying the human brain. They offer advantages over traditional methods, replicating anatomical structures, physiological features, and complex neuronal networks. Additionally, brain organoids can model nervous system development and interactions between cell types and the microenvironment. By providing a foundation for utilizing the most human-relevant tissue models, this work empowers researchers to overcome limitations of two-dimensional cultures and conduct advanced disease modeling research.

Simulation of tissue differentiation around acetabular cups: the effects of implant-bone relative displacement and polar gap

  • Mukherjee, Kaushik;Gupta, Sanjay
    • Advances in biomechanics and applications
    • /
    • v.1 no.2
    • /
    • pp.95-109
    • /
    • 2014
  • Peri-acetabular bone ingrowth plays a crucial role in long-term stability of press-fit acetabular cups. A poor bone ingrowth often results in increased cup migration, leading to aseptic loosening of the implant. The rate of peri-prosthetic bone formation is also affected by the polar gap that may be introduced during implantation. Applying a mechano-regulatory tissue differentiation algorithm on a two-dimensional plane strain microscale model, representing implant-bone interface, the objectives of the study are to gain an insight into the process of peri-prosthetic tissue differentiation and to investigate its relationship with implant-bone relative displacement and size of the polar gap. Implant-bone relative displacement was found to have a considerable influence on bone healing and peri-acetabular bone ingrowth. An increase in implant-bone relative displacement from $20{\mu}m$ to $100{\mu}m$ resulted in an increase in fibrous tissue formation from 22% to 60% and reduction in bone formation from 70% to 38% within the polar gap. The increase in fibrous tissue formation and subsequent decrease in bone formation leads to weakening of the implant-bone interface strength. In comparison, the effect of polar gap on bone healing and peri-acetabular bone ingrowth was less pronounced. Polar gap up to 5 mm was found to be progressively filled with bone under favourable implant-bone relative displacements of $20{\mu}m$ along tangential and $20{\mu}m$ along normal directions. However, the average Young's modulus of the newly formed tissue layer reduced from 2200 MPa to 1200 MPa with an increase in polar gap from 0.5 mm to 5 mm, suggesting the formation of a low strength tissue for increased polar gap. Based on this study, it may be concluded that a polar gap less than 0.5 mm seems favourable for an increase in strength of the implant-bone interface.

Simulation of Bone Fracture Healing by the Complex System Rule (복잡계를 응용한 인체 골절치료 모델링과 해석에 관한 연구)

  • 문병영;박정홍
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.12
    • /
    • pp.198-204
    • /
    • 2003
  • The bone fracture healing is simulated by using one of the complex system rules, named cellular automata method. It is assumed that each cell has property of Bone, Cartilage or Fibrous connective tissue. Nine local rules are adopted to change the property of each cell against the mechanical stimulus, which consists of the strain energy density, and the existence of bone in the surroundings. Two dimensional sheep metatarsal model is considered and the bone fracture healing is simulated. The simulation results agree well with those obtained by using fuzzy logic model and experimental data. The cellular automata method found to be one of the simulation methods to express the bone fracture healing. The cellular automata method is expected to be effective in representing biological phenomenon.

A THREE DIMEMSIONAL PHOTOELASTIC STRESS ANALYSIS OF IMPLANT SUPPORTING BONE TISSUE ACCORDING TO DESIGN OF ATTACHMENTS USED FOR MANDIBULAR OVERDENTURE USING TWO OSSEOINTEGRATED IMPLANSTS (두개의 골유착성 임프란트를 이용한 하악 OVERDENTURE에서 ATTACHMENT 설계에 따른 임프란트 지지조직의 삼차원적 광탄성 응력분석)

  • Shin, Kyoo-Hag;Jeong, Chang-Mo;Jeon, Young-Chan;Hwang, Hie-Seong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.1
    • /
    • pp.31-69
    • /
    • 1996
  • The purpose of this investigation was to analyze stress distribution in implant supporting tissue according to different types of attachments such as combination bar attachment, Hader bar attachment, O-Ring attachment and Dal-Ro attachment that are used in mandibular overdenture by using two osseointegrated implants, to study the influence that POM IMC used in bar type attachment has in implant supporting tissue and compare the preceding analyses to find out an effective stress distribution method. Three dimensional photoelastic method was used to obtain the following results. (A) Analysis of stress distribution according to attachment type 1. Under vertical load condition, compressive stress was seen at implant supporting area of working side on all the photoelastic models but in Hader bar attachment tensional stress was seen at distal upper area of implant supporting area. Relatively Hader bar and O-Ring attachment showed even stress distribution pattern. 2. Under vertical load condition, compressive stress at implant apex area and tensional stress at implant lateral supporting area were seen at nonworking side of all models. 3. Under $25^{\circ}$ lateral load condition, general compressive stress was seen at working side implant supporting area in most of the models, especially at distal upper supporting area higher compressive stress concentration was seen in combination bar attachment and tensional stress concentration, in Hader bar attachment. 4. Under $25^{\circ}$ lateral load condition, compressive stress at implant apex area and tensional stress at implant lateral supporting area were seen at nonworking side of all models, except O-Ring model which showed compressive stress only. (B) Influence of POM IMC to stress distribution in bar type attachment 5. Under vertical load condition, better stress distribution pattern was seen at working side of combination bar and Hader bar attachment model using POM IMC. 6. Under vertical load condition, stress value was increased at nonworking side of combination bar attachment model using POM IMC and tendency of increasing compression was seen at nonworking side of Hader bar attachment model using POM IMC. 7. Under $25^{\circ}$ lateral load condition, better stress distribution pattern was seen at working side of combination bar attachment model using POM IMC but tendency of increasing stress was seen on working side of Hader bar attachment model using POM IMC. 8. Under $25^{\circ}$ lateral load condition, stress reduction was seen at nonworking side of combination bar attachment model using POM IMC but tendency of increasing stress was seen at nonworking side of Hader bar attachment model using POM IMC.

  • PDF

THE FINITE ELEMENTS ANALYSIS IN THE THREE DIMENSIONAL CELL CULTURE MODEL OF THE COLLAGEN MATRIX ACCORDING TO THE APPLICATION FORCE (교원섬유 기질을 이용한 3차원 세포 배양 모델에 기계적인 힘을 가하는 경우 기질을 통하여 세포에 가해지는 힘의 특성에 대한 비교 분석 연구)

  • Kim, Hyeon-Jong;Rhyu, In-Chul;Park, Jun-Woo;Kim, Seong-Gon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.2
    • /
    • pp.151-156
    • /
    • 2008
  • Different kinds of forces can be applied to the biological tissue. The analysis of the applied force is highly important to explain the mechanism of cellular response. In this study, the applied force to the collagen gel was analyzed by the finite elements analysis. The model received two different kinds of static force (compression and tension). The force range was 50g to 400g. In results, von Mises stress was concentrated in the peripheral region in the compression model. It was concentrated in the central area in the tension model. However, the compressive force was high in the peripheral area of the compression model and the tensional force was also high in the same area of the tension model. In conclusion, the applied force could be different to the region and it should be considered in the experiment to analyze the effects of the mechanical force on the cells.