• 제목/요약/키워드: Two dimension array

검색결과 38건 처리시간 0.021초

Application of Three-Dimensional Light Microscopy for Thick Specimen Studies

  • Rhyu, Yeon Seung;Lee, Se Jeong;Kim, Dong Heui;Uhm, Chang-Sub
    • Applied Microscopy
    • /
    • 제46권2호
    • /
    • pp.93-99
    • /
    • 2016
  • The thickness of specimen is an important factor in microscopic researches. Thicker specimen contains more information, but it is difficult to obtain well focused image with precise details due to optical limit of conventional microscope. Recently, a microscope unit that combines improved illumination system, which allows real time three-dimensional (3D) image and automatic z-stack merging software. In this research, we evaluated the usefulness of this unit in observing thick samples; Golgi stained nervous tissue and ground prepared bone, tooth, and non-transparent small sample; zebra fish teeth. Well focused image in thick samples was obtained by processing z-stack images with Panfocal software. A clear feature of neuronal dendrite branching pattern could be taken. 3D features were clearly observed by oblique illumination. Furthermore, 3D array and shape of zebra fish teeth was clearly distinguished. A novel combination of two channel oblique illumination and z-stack imaging process increased depth of field and optimized contrast, which has a potential to be further applied in the field of neuroscience, hard tissue biology, and analysis of small organic structures such as ear ossicles and zebra fish teeth.

의료용 초고휘도 LCD 소자를 위한 직하형 Backlight의 최적설계 (Optical Design for High Brightness Direct Type Backlight Unit Using Medical LCD Application)

  • 한정민;김원배
    • 한국위성정보통신학회논문지
    • /
    • 제11권3호
    • /
    • pp.28-31
    • /
    • 2016
  • 본 연구에서는 최근 의료용으로 많이 사용되고 있는 고휘도, 고균일도의 직하광원구조를 가지는 백라이트 유닛에 대한 설계 시뮬레이션을 실시하였다. 직하형 백라이트 시스템은 기존의 Edge-Lighr 방식에 비해서 고휘도 및 고균일도를 달성할 수 있어 의료용 판독이 요구되는 고품질의 디스플레이에 사용되고 있으며, 흑백이미지를 바탕으로 진단을 실시하는 경우가 많기 때문에 휘도 및 휘도 균일도에 대한 높은 성능이 요구되는 분야이다. 본 연구에서는 복수 개의 램프를 수평으로 배열한 경우에 각 램프간의 거리 및 반사판과의 거리, 상측 확산판과의 거리에 대한 최적설계를 실시하고, 이 결과를 바탕으로 실물과 유사한 조건에서 시뮬레이션을 실시하였다. 연구 결과, Parameter 에 의존하는 변수를 최적화 할 수 있었으며, 4.5mm 의 램프와 반사판 거리 및 26mm 의 램프간 거리를 바탕으로 16개의 램프를 배치하여, 32인치 크기의 화면에서 6423nit 의 중심휘도를 갖는 고품위의 우수한 광원의 설계가 가능함을 확인할 수 있었다.

이차원 양성자 선량 분포 확인을 위한 즉발감마선 이차원분포 측정 장치 개발 (Development of Two-dimensional Prompt-gamma Measurement System for Verification of Proton Dose Distribution)

  • 박종훈;이한림;김찬형;김성훈;김성훈;이세병
    • 한국의학물리학회지:의학물리
    • /
    • 제26권1호
    • /
    • pp.42-51
    • /
    • 2015
  • 양성자 치료 시 양성자 빔을 사용하여 정밀한 치료를 수행하고 환자의 안전을 제고하기 위해서는 인체 내 양성자 빔의 선량 분포를 확인하는 것이 중요하다. 이를 위해 본 연구팀은 이전 연구에서 1차원 배열형 검출기를 종형으로 배치하여 빔 진행방향으로 이동시켜가면서 2차원적인 즉발감마선 분포를 측정하여 양성자 선량 분포와 유사한 분포를 갖는 것을 확인하였다. 본 연구에서는 이를 바탕으로 즉발감마선 이차원분포를 실시간으로 측정하기 위해 이차원 평행다공형 집속 장치, 이차원 배열의 NaI(Tl) 섬광체와 MA-PMT로 이루어진 즉발감마선 이차원분포 측정 장치를 개발하였다. 개발한 즉 발감마선 이차원분포 측정 장치의 성능을 평가한 결과 $^{22}Na$ 감마선원의 에너지 분해능은 $10.9%{\pm}0.23p%$ (0.511 MeV)와 $6.4%{\pm}0.24p%$ (1.275 MeV)로 평가되었으며, $^{137}Cs$$9.8%{\pm}0.18p%$ (0.662 MeV)로 평가되었다. 고에너지 Am-Be 선원의 double escape 피크인 3.416 MeV의 에너지 분해능은 $11.4%{\pm}3.6p%$로 평가되었다. 본 측정 장치를 이용하여 45 MeV 양성자 빔을 PMMA에 조사하여 발생한 즉발감마선 이차원분포를 측정한 결과 0.5 nA의 세기의 양성자 빔에서 $9{\times}10^9$ 양성자 조사 시 양성자 선량 분포와 유사한 즉발감마선 이차원분포를 측정할 수 있음을 확인하였다. 추가로 측정한 즉발감마선 이차원분포의 프로파일 분포를 이용하여 양성자 빔의 비정을 평가해 본 결과 $17.0{\pm}0.4mm$로 평가되었고, 실제 비정인 17.4 mm과 굉장히 밀접한 관련이 있음을 확인하였다.

주성분분석을 이용한 토끼 망막 신경절세포의 활동전위 파형 분류 (PCA­based Waveform Classification of Rabbit Retinal Ganglion Cell Activity)

  • 진계환;조현숙;이태수;구용숙
    • 한국의학물리학회지:의학물리
    • /
    • 제14권4호
    • /
    • pp.211-217
    • /
    • 2003
  • 주성분분석은 잘 알려진 데이터 분석 방법으로써 높은 차원의 데이터를 낮은 차원의 데이터로 표현하는데 효과적이어서 얼굴인식, 데이터 압축 등에 이용되고 있다. 주성분분석을 하게 되면 원 데이터의 공분산 행렬로부터 정규직교한 고유벡터와 해당하는 고유치를 얻게 되고 그 중 큰 값을 가지는 고유벡터 들을 선택하여 선형 변환함으로써 데이터의 차원을 줄일 수 있게 된다. 망막에 빛 자극이 인가되면 시세포 층에서 전기신호로 변환된 후 복잡한 신경회로를 거쳐 최종적으로 신경절세포 층에서 활동전위의 형태로 출력되게 된다. 본 연구에서는 다채널전극을 사용하여 여러 개 망막 신경절세포로부터 유래되는 활동전위를 기록한 후 개개의 신호를 구분하는 과정을 거치고, 이어서 그 신호를 만들어 내는 각 뉴론들끼리의 시간적, 공간적 흥분발사 패턴을 이해함으로써 궁극적으로 시각정보 인코딩 기전을 밝히려는 연구 목표하에 그 첫 단계로서 망막 신경절세포의 활동전위를 기록한 후 분류하는 과정을 성공적으로 수행하였기에 그 내용을 서술하고자 한다. 망막에서 기록되는 신경절세포 활동전위는 불규칙하고 확률적이기 때문에 주성분분석을 통하여 그 유형을 분류할 수 있었다. 토끼 눈으로부터 망막을 박리하여 망막조각을 얻은 후 신경절세포 층이 전극표면을 향하도록 전극에 부착하였다. 8${\times}$8의 microelectrode array (MEA)를 전극으로 사용하였고, 증폭기는 MEA 60 system을 사용하여 신경절세포 활동전위를 기록하였다. 활동전위 기록 후 파형 분류를 하였다. 잡음이 섞여있는 기록으로부터 신호를 검출하기 위하여, 잡음역치($\pm$3$\sigma$)를 설정하였다. 역치를 넘는 파형 만을 획득한 후 주성분분석을 통해 각 파형의 첫 번째 주성분, 두 번째 주성분을 계산하여 2차원 평면에 투사함으로써 몇 개의 의미있는 클러스터를 얻었다. 이 클러스터는 곧 각 신경절세포에서 유래되는 파형을 반영하므로 주성분분석을 통하여 망막 신경절세포의 활동전위를 각 세포별로 분류할 수 있음을 확인하였다.

  • PDF

THE MULTIPLE PROTO STELLAR SYSTEM L1551 IRS5 AT 5 AU RESOLUTION

  • LIM JEREMY;TAKAKUWA SHIGEHISA
    • 천문학회지
    • /
    • 제38권2호
    • /
    • pp.237-240
    • /
    • 2005
  • We present images of L1551 IRS5 at angular resolutions as high as ${\~}$30 mas, corresponding to a spatial resolution of ${\~}$5 AU, made at 7 mm with the VLA. Previously known to be a binary protostellar system, we show that L1551 IRS5 is likely a triple protostellar system. The primary and secondary components have a projected separation of ${\~}$46 AU, whereas the tertiary component has a projected separation of ${\~}$11 AU from the primary component. The circumstellar dust disks of the primary and secondary components have dimensions of ${\~}$15 AU, whereas that of the tertiary component has a dimension of ${\~}$10 AU. Their major axes are closely, but not perfectly, aligned with each other, as well as the major axis of the surrounding flattened, rotating, and contracting molecular condensation (pseudodisk). Furthermore, the orbital motion of the primary and secondary components is in the same direction as the rotational motion of this pseudodisk. We suggest that all three protostellar components formed as a result of the fragmentation of the central region of the molecular pseudo disk. The primary and secondary components, but apparently not the tertiary component, each exhibits a bipolar ionized jet that is centered on and which emergers perpendicular to its associated dust disk. Neither jets are resolved along their base, implying that they are driven within a radial distance of ${\~}$2.5 AU from their central protostars. Finally, we show evidence for what may be dusty matter streams feeding the two main protostellar components.

전기비저항탐사에 의한 제당의 누수구간 탐지 (Delineation of water seepage in earth-fill embankments by electrical resistivity method)

  • 정승환;김정호;양재만;한규언;김영웅
    • 지질공학
    • /
    • 제2권1호
    • /
    • pp.47-57
    • /
    • 1992
  • 파쇄대 및 균열대를 따라 비교적 심부에 분포하는 우리나라 암반 지하수 탐지를 위한 효과적인 물리탐사방법과 농업용 제당의 누수구간 탐지를 위한 소위 비파괴적 탐지방법의 개발을 위한 연구를 실시하였다. 이를 위해 종래 사용하던 1차원적인 수직 비저항탐사(Vertical electrical sounding)보다 2차원적인 수평-수직 탐사를 동시에 수행할 수 있는 쌍극자 비저항배역(dipole-dipole array)탐사법을 이용하는 야외탐사방법의 확립과 획득된 자료의 정량해석을 위한 computer program을 개발하였다. 본 연구에서는 쌍극자배열탐사법과 정량해석 program의 효율성을 검증하기 위해 이미 지질 및 시추조사가 종료된 두 곳의 누수 제당에 대하여 야외탐사를 하였다. 야외조사를 통해 획득된 자료들에 대하여 본 연구를 통해 개발된 program을 활용하였던바, 제당누수구간 및 파쇄대 내지는 단층대내에 발달되는 암반지하수 탐지에 효율적임이 입증되었다. 본 연구에서는 개발된 쌍극자 비저항탐사법과 해석 program은 암반지하수 탐지는 물론 누수제당의 누수구간 탐지 및 안전성 진단 등에 적극 활용할 수 있으리라 판단된다.

  • PDF

X-대역 응용을 위한 광대역 전파 흡수체 설계 (Design of the Wideband Microwave Absorber for X-band Applications)

  • 홍영택;정구호;최재훈
    • 한국전자파학회논문지
    • /
    • 제28권9호
    • /
    • pp.749-755
    • /
    • 2017
  • 본 논문에서는 X-대역(8~12 GHz) 응용을 위한 광대역 전파 흡수체를 제안하였다. 제안된 흡수체 unit cell 구조는 슬롯과 슬릿을 포함하는 공진기, 뒷면의 도체판, $8.5{\times}8.5{\times}0.5mm^3$의 크기를 갖는 Taconic RF-30(${\varepsilon}_r=3$, $tan{\delta}=0.0014$) 기판으로 이루어져 있다. 제안된 흡수체는 9.83 GHz와 10.37 GHz에서 공진이 발생하는 이중 공진 특성을 갖는다. 제안된 흡수체 구조의 동작 원리를 검증하기 위하여 각각의 공진주파수에서 unit cell 구조의 표면 전류 분포를 분석하였다. 제안된 흡수체의 성능을 확인하기 위하여 $20{\times}20$개의 unit cell 배열 시제품을 제작하였다. 측정 결과, 최대 흡수율을 갖는 지점에서 모두 99 % 이상의 흡수율이 측정되었으며, 측정된 full-width at half-maximum(FWHM) 대역폭은 1.1 GHz(9.51~10.61 GHz)이다.

ZnO nanostructures for e-paper and field emission display applications

  • Sun, X.W.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.993-994
    • /
    • 2008
  • Electrochromic (EC) devices are capable of reversibly changing their optical properties upon charge injection and extraction induced by the external voltage. The characteristics of the EC device, such as low power consumption, high coloration efficiency, and memory effects under open circuit status, make them suitable for use in a variety of applications including smart windows and electronic papers. Coloration due to reduction or oxidation of redox chromophores can be used for EC devices (e-paper), but the switching time is slow (second level). Recently, with increasing demand for the low cost, lightweight flat panel display with paper-like readability (electronic paper), an EC display technology based on dye-modified $TiO_2$ nanoparticle electrode was developed. A well known organic dye molecule, viologen, was adsorbed on the surface of a mesoporous $TiO_2$ nanoparticle film to form the EC electrode. On the other hand, ZnO is a wide bandgap II-VI semiconductor which has been applied in many fields such as UV lasers, field effect transistors and transparent conductors. The bandgap of the bulk ZnO is about 3.37 eV, which is close to that of the $TiO_2$ (3.4 eV). As a traditional transparent conductor, ZnO has excellent electron transport properties, even in ZnO nanoparticle films. In the past few years, one-dimension (1D) nanostructures of ZnO have attracted extensive research interest. In particular, 1D ZnO nanowires renders much better electron transportation capability by providing a direct conduction path for electron transport and greatly reducing the number of grain boundaries. These unique advantages make ZnO nanowires a promising matrix electrode for EC dye molecule loading. ZnO nanowires grow vertically from the substrate and form a dense array (Fig. 1). The ZnO nanowires show regular hexagonal cross section and the average diameter of the ZnO nanowires is about 100 nm. The cross-section image of the ZnO nanowires array (Fig. 1) indicates that the length of the ZnO nanowires is about $6\;{\mu}m$. From one on/off cycle of the ZnO EC cell (Fig. 2). We can see that, the switching time of a ZnO nanowire electrode EC cell with an active area of $1\;{\times}\;1\;cm^2$ is 170 ms and 142 ms for coloration and bleaching, respectively. The coloration and bleaching time is faster compared to the $TiO_2$ mesoporous EC devices with both coloration and bleaching time of about 250 ms for a device with an active area of $2.5\;cm^2$. With further optimization, it is possible that the response time can reach ten(s) of millisecond, i.e. capable of displaying video. Fig. 3 shows a prototype with two different transmittance states. It can be seen that good contrast was obtained. The retention was at least a few hours for these prototypes. Being an oxide, ZnO is oxidation resistant, i.e. it is more durable for field emission cathode. ZnO nanotetropods were also applied to realize the first prototype triode field emission device, making use of scattered surface-conduction electrons for field emission (Fig. 4). The device has a high efficiency (field emitted electron to total electron ratio) of about 60%. With this high efficiency, we were able to fabricate some prototype displays (Fig. 5 showing some alphanumerical symbols). ZnO tetrapods have four legs, which guarantees that there is one leg always pointing upward, even using screen printing method to fabricate the cathode.

  • PDF