• Title/Summary/Keyword: Two Spheres

Search Result 145, Processing Time 0.028 seconds

Synthesis and Physical Properties of MO·Fe12O18 (M/Ba and Sr) Nanoparticles Prepared by Sol-Gel Method Using Propylene Oxide (Propylene Oxide를 이용한 졸-겔법에 의한 MO·Fe12O18 (M/Ba, Sr) 나노 분말의 합성과 물리적 특성)

  • Lee, Su Jin;Choe, Seok Burm;Gwak, Hyung Sub;Paik, Seunguk
    • Applied Chemistry for Engineering
    • /
    • v.17 no.4
    • /
    • pp.420-425
    • /
    • 2006
  • Nano sized mixed metal hexagonal ferrite powders with improved magnetic properties have been prepared by sol-gel method using propylene oxide as a gelation agent. To obtain the desired ferrite, two different metal ions were used. One of the ions has only +2 formal charge. The key step in the processes is that hydrated $Ba^{2+}$ or $Sr^{2+}$ ions are hydrolyzed and condensed at the surface of the previously formed $Fe_{2}O_{3}$ gel. In this processes, all the reaction can be finished within a few minutes. The magnetic properties of the produced powder were improved by heat treatment. The highest values of the magnetic properties were achieved at temperature $150^{\circ}C$ lower than those of the previously published values. The highest observed values of coercivity and the saturation magnetization of Sr-ferrite and Ba-ferrite powder were 6198 Oe, 5155 Oe and 74.4 emu/g, 68.1 emu/g, respectively. The ferrite powder annealed at $700^{\circ}C$ showed spherical particle shapes. The resulting spheres which were formed by the aggregation of nanoparticles with size 3~5 nm have diameter around 50 nm. The powder treated at $800^{\circ}C$ showed hexagonal-shaped grains with crystallite size above 500 nm.

Measurements of $T_1$-and $T_2$-relaxation Time Changes According to the Morphological Characteristics of Gold Nanoparticles (GNPs) (금 나노 입자의 형태적 특성에 따른 $T_1$, $T_2$ 이완 시간의 변화 측정)

  • Jang, M.Y.;Han, Y.H.;Mun, C.W.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.48-56
    • /
    • 2011
  • Purpose : The aim of this study is to measure the typical MR variables such as $T_1$- and $T_2$-relaxation times according to morphological characteristics of gold nanopartides as a preliminary study to perform theragnosis using local heating by gold nanopartides. Materials and Methods : Two types of gold nanoparticles were used. Spheres were synthesized by various methods and stirring speed. Rods were synthesized by adding various concentrations of sphere nanopartides. Gold nanopartides were mixed with 2% agarose gel at 1:1 ratio and then signals were acquired using a 1.5T MRI. For the measurements of $T_1$-and $T_2$-relaxation times, TR and TE were varied, respectively. The results were acquired through $T_1$ and $T_2$ curves based on the intensities of MR image using self-developed software. And Statistical analysis was performed. Results : $T_1$ times were measured 1.86 sec and 2.08 sec for sphere and rod, respectively. On the other hands, $T_2$ times were measured 57 ms and 35.45 ms for sphere and rod. Conclusion : The changes of the MR variables according to the morphological characteristics of the gold nanopartides were confirmed. Optimal MR imaging conditions can be obtained by choosing proper TR and TE according to the type of nanoparticles.

A New Strategy to Fabricate a Colloidal Array Templated $TiO_2$ Photoelectrode for Dye-sensitized Solar Cells

  • Lee, Hyeon-Jeong
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.8.1-8.1
    • /
    • 2011
  • Nanocrystalline titanium dioxide ($TiO_2$) materials have been widely used as an electron collector in DSSC. This is required to have an extremely high porosity and surface area such that the dye can be sufficiently adsorbed and be electronically interconnected, resulting in the generation of a high photocurrent within cells. In particular, their geometrical structures and crystalline phase have been extensively investigated as important issues in improving its photovoltaic efficiency. In this study, we present a new strategy to fabricate a photoelectrode having a periodic structured $TiO_2$ film templated from 1D or 3D polystyrene (PS) microspheres array. Monodisperse PS spheres of various radiuses were used for colloidal array on FTO glasses and two types of photoelectrode structures with different $TiO_2$ materials were investigated respectively. One is the igloo-shaped electrode prepared by $TiO_2$ deposition by RF-sputtering onto 2D microsphere-templated substrates. At the interface between the film and substrate, there are voids formed by the decomposition of PS microspheres during the calcination step. These holes might be expected to play the predominant roles as scattering spherical voids to promote a light harvesting effect, a spacious structure for electrolytes with higher viscosity and effective paths for electron transfer. Additionally the nanocrystalline $TiO_2$ phase prepared by the RF-sputtering method was previously reported to improve the electron drift mobility within $TiO_2$ electrodes. This yields solar cells with a cell efficiency of 2.45% or more at AM 1.5 illumination, which is a very remarkable result, considering its $TiO_2$ electrode thickness (<2 ${\mu}m$). This study can be expanded to obtain higher cell efficiency by higher dye loading through the increase of surface area or multi-layered stacking. The other is the inverse opal photonic crystal electrode prepared by titania particles infusion within 3D colloidal arrays. To obtain the enlargement of ordered area and high quality of crystallinity, the synthesis of titania particles coated with a organic thin layer were applied instead of sol-gel process using the $TiO_2$ precursors. They were dispersed so well in most solvents without aggregates and infused successfully within colloidal array structures. This ordered mesoporous structure provides the large surface area leading to the enough adsorption of dye molecules and have an light harvesting effect due to the photonic band gap properties (back-and-forth reflection effects within structures). A major advantage of this colloidal array template method is that the pore size and its distribution within $TiO_2$ photoelectrodes are determined by those of latex beads, which can be controlled easily. These materials may have promising potentials for future applications of membrane, sensor and so on as well as solar cells.

  • PDF

From 'Medicalization' to 'Biomedicalization': the Case of Mental Disorder ('의료화'에서 '생의료화'로: 정신장애의 사례)

  • Kim, Hwan-Suk
    • Journal of Science and Technology Studies
    • /
    • v.14 no.1
    • /
    • pp.3-33
    • /
    • 2014
  • Over the last forty years, the dominant perspective of social science on medicine has been the medicalization theory. It indicates the social process of expanding power of medical professionals by (re)defining the problems which were treated as non-medical phenomena(e.g. homosexuality, alcoholism, obesity, etc.) into "diseases" and thus the spheres of medical intervention. Meanwhile, rapid technoscientific changes in the medical field owing to the diffusion of biological sciences and information technologies since the mid-1980s and the accompanying emergence of new social arrangements such as bioeconomy and biological citizenship have led to the rise of a new social scientific perspective called the biomedicalization theory. This paper attempts to compare the two theories and assess their merits and demerits as a basic work to deepen the understandings of sociology and STS on contemporary medicine. And it also attempts to analyze their relative relevance through the case of mental disorder. The analysis on the case of mental disorder clearly shows that the medicalization in that area seems to have continuously proceeded since the early 19th centiry to the present. Furthermore, it also seems true that the five central processes of biomedicalization(except for risk surveillance technologies of mental disorder) have been observed and realized since the late 20th century. These results indicate that although medicalization has consistently proceeded, it has not been limited to the quantitative expansion of the medical field but been extended to the qualitative transformation asserted by the biomedicalization theory. Therefore, while the concept of medicalization is valid and significant even today, we can recognize that the concept of biomedicalization allow us to capture the new phenomena which cannot be properly and sufficiently captured by that of medicalization.

  • PDF

Kinetic Study of Proton Exchange between Al($H_2O$)$_6^{3+}$ Ion and Bulk Water Molecules (Ⅰ) (Al($H_2O$)$_6^{3+}$ 이온과 물 용매 분자 사이에서의 수소 이온 교환의 반응속도론적 연구 (Ⅰ))

  • Moon-Hwan Cho;Jin-Ho Kim;Chang-Ju Yoon
    • Journal of the Korean Chemical Society
    • /
    • v.32 no.5
    • /
    • pp.436-442
    • /
    • 1988
  • The $^1H-nmr$ lineshapes of $H_2O$ in the solution containing $Al^{3+}$ ion have been measured as a function of temperature and $H^+$-ion concentration. Above [$H^+$] = 0.06, the lineshape were analyzed by the uncoupled two-site exchange model. From the proton exchange rate between hexaaquaaluminium ion and bulk water as a function of H-ion concentration. These kinetic data could be fitted to a following linear rate law; that is; 1/${\tau}$ = k$_1$/12 + $k_2$[$H^+$]/6. The following proton exchange parameters were obtained; $k_1^{298}$ = 38.5s$^{-1}$ ${\{Delta}H_1^{\neq}$ = $42.9kJ mole^{-1}$ ${\{Delta}S_1^{\neq}$ = -48.6J $mole^{-1}K^{-1}$ $k_2^{298}$ = $172s^{-1}mole^{-1}$ ${\{Delta}H_2^{\neq}$ = 27.8kJ $mole^{-1}$ ${\{Delta}S_2^{\neq}$ = -90.3J $mole^{-1}K^{-1}$ These activation parameters are indicating an associative interchange, Ia, mechanism for the acid-hydrolysis of hexaaquaaluminium ion and the proton exchange between the hydration spheres of $Al^{3+}$ and $H^+$.

  • PDF

Improvement of a Planning Technique Based on Heuristic Target Shaping for Stereotactic Radiosurgery (방사선 수술시 경험적 표적 근사화에 근거한 최적화 방법 개선)

  • Oh Seungjong;Choi Kyoung-Sik;Song Ju-Young;Suh Tae-Suk
    • Progress in Medical Physics
    • /
    • v.16 no.4
    • /
    • pp.176-182
    • /
    • 2005
  • Stereotactic radiosurgery (SRS) is a technique to deliver a high dose to a target region and a low dose to a critical organ through only one or a few irradiation. The SRS must be planned exactly. Currently the surgery plan is peformed by trial and error method. There are many questions about the reliability and reproducibility of the plan result. This study Improve each step of the Oh's method based on heuristic target shaping to obtain the better result. The target was reconstructed using cylinders with same height and the neighbored cylinders were combined according to the difference of each center and diameter. Then, spheres were packed within each cylinders by the packing rules. Two virtual targets were used to compare this method with Oh's method. As a result, the numbers of isocenter were successfully reduced - more than $35\%$ and $26\%$ - without serious differences of proscription isodose to tumour volume ratio (PITV) and maximum dose to proscription dose ratio (MDPD). This technique using cylinder piling and sphere packing will be a helpful tool to planner in stereotactic radiosurgery.

  • PDF

High Ferrihydrite Turbidity in Groundwater of Samdong-Myeon (Ulsan) by Carbonate-Water Inflow of Deep Origin (심부 탄산수의 유업에 의한 울산시 삼동면 지하수의 높은 페리하이드라이트 탁도)

  • Jeong, Gi-Young;Kim, Seok-Hwi;Kim, Kang-Joo;Jun, Seong-Chun;Ju, Jeong-Woung;Choi, Mi-Jung;Cheon, Jeong-Yong
    • Journal of the Mineralogical Society of Korea
    • /
    • v.24 no.2
    • /
    • pp.91-99
    • /
    • 2011
  • The turbidity in several wells of Samdong-myeon, Ulsan, exceeded potable groundwater standard (1 NTU). Mineralogical analysis showed that the fine suspended particles are ferrihydrite spheres with a size of less than $0.5\;{\mu}m$ and helical iron-oxidizing bacterial filaments, and their aggregates. Ferrihydrite was almost amorphous only showing two electron diffraction rings, and contained Si and P. Helical bacterial filaments were almost replaced by ferrihydrite. The helical bacteria have played an important role in the ferrihydrite formation by becoming the loci for ferrihydrite precipitation as well as oxidizing ferrous iron. The physicochemical conditions of low pH, low redox potential, high Ca concentration, and high alkalinity are consistent with the hydrogeochemical characteristics of carbonate groundwater, implicating that the inflow of deep ferriferous carbonate groundwater and its oxidation have caused the ferrihydrite turbidity in several wells of the study area.

Analyzing the Effect of COVID-19 on the Operational Efficiency of Asia's Major Container Ports: A Data Envelopment Analysis (COVID-19 위기가 아시아 주요 컨테이너항만의 운영효율성에 미치는 영향)

  • KIM, Tae-Hyung;CHOI, Sang-Duk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.6
    • /
    • pp.763-774
    • /
    • 2021
  • The COVID-19 virus has generated major shockwaves in all spheres of human life since its outbreak. Maritime transport (both cargo and passenger) is one of the industries most heavily affected, yet over 80% of the world cargo is transported by sea. This study analyzes maritime port operational efficiencies before and after the start of the COVID-19 pandemic to determine whether the pandemic has caused major differences in the operational efficiencies of many leading Asian maritime container ports via data envelopment analysis (DEA). The results of both the CCR and BCC models reveal that overall, efficiency during the COVID-19 pandemic has been higher than before the pandemic despite a few inefficiencies. This implies that the pandemic has so far not has major consequences for the operational efficiency of maritime ports. However, two ports (Busan and Guangzhou) should adjust the scale sizes and technical capacities of their operations to improve performance.

The Development of Wholeness Program for Effects Dementia-Buffering Testing of the Demented Elderly (노인의 치매행동 관련 홀니스 프로그램 개발과 완충효과 검증)

  • Hong, Hye-Jeon
    • 한국체육학회지인문사회과학편
    • /
    • v.57 no.1
    • /
    • pp.405-419
    • /
    • 2018
  • This study of the Wholeness Program relevant to dementia behavior and verification of buffering effects. For the purpose of this, among those who were attending Day Care Centers belonging to Seniors Welfare Center of M1 and M2 located in Seoul. Among those who met all these requirements, 40 senior citizens were finally selected. After carrying out a preliminary test to the selected subjects, 20 elderly of Seniors Welfare Center of M1 were randomly placed as an experimental group, while other 20 people of Seniors Welfare Center of M2, as a control group. The Wholeness Program relevant to dementia behavior was carried out from March 14 to May 30 of 2016, for 12 weeks, twice a week. As for the measurement tool, this study depended on the Korean version of Mini Mental State Examination (MMSE-K), the Korean version of Modified Barthel Index (K-MBI) and the Korean version of Geriatric Depression Scale (GDS-K). While the elderly were participating in the Wholeness Program relevant to dementia behavior, they were measured two times in total, before and after the participation in dementia behavior. Based on SPSS-PC (version 21.0), firstly, independent t-test was carried out to understand the homogeneity between the experimental group and the control group. Secondly, matched-pair t-test was carried out between preliminary test and post-test to inquire into the effects of MMSE-K, K-MBI and GDS-K. Thirdly, ANOVA was conducted to confirm the variation (change amount) between preliminary test and post-test. According to the survey results, the Wholeness Program relevant to dementia behavior of the elderly shows overall effects in all spheres of changes of cognitive ability (MMSE-K), changes of physical capacity (K-MBI) and changes of depression level (GDS-K).

The Understanding and Application of Noise Reduction Software in Static Images (정적 영상에서 Noise Reduction Software의 이해와 적용)

  • Lee, Hyung-Jin;Song, Ho-Jun;Seung, Jong-Min;Choi, Jin-Wook;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.54-60
    • /
    • 2010
  • Purpose: Nuclear medicine manufacturers provide various softwares which shorten imaging time using their own image processing techniques such as UlatraSPECT, ASTONISH, Flash3D, Evolution, and nSPEED. Seoul National University Hospital has introduced softwares from Siemens and Philips, but it was still hard to understand algorithm difference between those two softwares. Thus, the purpose of this study was to figure out the difference of two softwares in planar images and research the possibility of application to images produced with high energy isotopes. Materials and Methods: First, a phantom study was performed to understand the difference of softwares in static studies. Various amounts of count were acquired and the images were analyzed quantitatively after application of PIXON, Siemens and ASTONISH, Philips, respectively. Then, we applied them to some applicable static studies and searched for merits and demerits. And also, they have been applied to images produced with high energy isotopes. Finally, A blind test was conducted by nuclear medicine doctors except phantom images. Results: There was nearly no difference between pre and post processing image with PIXON for FWHM test using capillary source whereas ASTONISH was improved. But, both of standard deviation(SD) and variance were decreased for PIXON while ASTONISH was highly increased. And in background variability comparison test using IEC phantom, PIXON has been decreased over all while ASTONISH has shown to be somewhat increased. Contrast ratio in each spheres has also been increased for both methods. For image scale, window width has been increased for 4~5 times after processing with PIXON while ASTONISH showed nearly no difference. After phantom test analysis, ASTONISH seemed to be applicable for some studies which needs quantitative analysis or high contrast, and PIXON seemed to be applicable for insufficient counts studies or long time studies. Conclusion: Quantitative values used for usual analysis were generally improved after application of the two softwares, however it seems that it's hard to maintain the consistency for all of nuclear medicine studies because result images can not be the same due to the difference of algorithm characteristic rather than the difference of gamma cameras. And also, it's hard to expect high image quality with the time shortening method such as whole body scan. But it will be possible to apply to static studies considering the algorithm characteristic or we can expect a change of image quality through application to high energy isotope images.

  • PDF