• 제목/요약/키워드: Turns Ratio

검색결과 225건 처리시간 0.026초

분수슬롯을 가진 영구자석 전동기에서 극당 슬롯 비율이 코깅토크와 역기전력에 미치는 영향 (Effect of Pole to Slot Ratio on Cogging Torque and EMF Waveform in Permanent Magnet Motor with Fractional-Slot)

  • 이갑재;이주
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권9호
    • /
    • pp.454-459
    • /
    • 2003
  • Conventional integral-slot design in permanent magnet(PM) motor tends to have a high cogging torque and large end turns, which contribute to copper losses. The fractional-slot design is effective compared to integral-slot design in the cogging torque and electromotive force(EMF) waveform. The effectiveness of fractional slot can be maximized by selecting optimal pole to slot ratio. This paper presents the effect of pole to slot ratio on the cogging torque and EMF waveform in the PM motor with fractional-slot. The effectiveness of the proposed designs has been confirmed by comparing waveform of EMF. cogging torque and torque ripple between conventional and new models.

전류연속 모드 탭인덕터 부스트 컨버터의 분석과 설계 (Analysis and Design of Continuous Current Mode Tapped-Inductor Boost Converter)

  • 강정일;한상규;한종희
    • 전력전자학회논문지
    • /
    • 제19권4호
    • /
    • pp.349-356
    • /
    • 2014
  • As the turns ratio of the tapped-inductor contributes to the step-up ratio, the tapped-inductor boost (TIB) converter has significantly increased level of difficulties in its analysis and design compared to the conventional boost converter where the duty ratio is the sole factor affecting the step-up ratio. In this paper, the operation of the continuous current mode TIB converter is briefly reviewed, the characteristics are analyzed in detail, and a design guideline optimizing the loss in the tapped-inductor is presented with a practical design example. Finally, experimental results from a 12V/120V prototype for 0.25A LED driver application are also presented to confirm the design.

다구찌 실험 계획법을 이용한 나선형 인덕터의 패턴드 그라운드 쉴드 최적 설계 연구 (Optimization of 'Patterned Ground Shield' of Spiral Inductor using Taguchi's Method)

  • 고재형;오상배;김동훈;김형석
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2007년도 학술대회
    • /
    • pp.436-439
    • /
    • 2007
  • This paper describes the optimization of PGS(Patterned Ground Shield) of 5.5 turns rectangular spiral inductor using Taguchi's method. PGS is decrease method of parasite component by silicon substrate among dielectric loss reduction method. By using the taguchi's method, each parameter is fixed upon that PGS high poison(A), slot spacing(B), strip width(C) and overlap turn number(D) of PGS design parameter. Then we verified that percentage contribution and design sensitivity analysis of each parameter and level by signal to noise ratio of larger-the-better type. We consider percentage contribution and design sensitivity of each parameter and level, and then verify that model of optimization for PGS is lower inductance decreasing ratio and higher Q-factor increasing ratio by EM simulation.

  • PDF

High Step-Up Converter with Hybrid Structure Based on One Switch

  • Hwu, K.I.;Peng, T.J.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1566-1577
    • /
    • 2015
  • A novel high step-up converter is presented herein, which combines the conventional buck-boost converter, the charge pump capacitor and the coupling inductor. By doing so, a quite high voltage conversion ratio due to not only the turns ratio but also the duty cycle, so as to increase design feasibility. It is noted that the denominator of the voltage conversion ratio is the square of one minus duty cycle. Above all, there is no voltage spike across the switch due to the leakage inductance and hence no passive or active snubber is needed, and furthermore, the used switch is driven without isolation and hence the gate driving circuit is relatively simple, thereby upgrading the industrial application capability of this converter. In this paper, the basic operating principles and the associated mathematical deductions are firstly described in detail, and finally some experimental results are provided to demonstrate the effectiveness of the proposed high step-up converter.

Noninformative Priors for the Ratio of the Lognormal Means with Equal Variances

  • Lee, Seung-A;Kim, Dal-Ho
    • Communications for Statistical Applications and Methods
    • /
    • 제14권3호
    • /
    • pp.633-640
    • /
    • 2007
  • We develop noninformative priors for the ratio of the lognormal means in equal variances case. The Jeffreys' prior and reference priors are derived. We find a first order matching prior and a second order matching prior. It turns out that Jeffreys' prior and all of the reference priors are first order matching priors and in particular, one-at-a-time reference prior is a second order matching prior. One-at-a-time reference prior meets very well the target coverage probabilities. We consider the bioequivalence problem. We calculate the posterior probabilities of the hypotheses and Bayes factors under Jeffreys' prior, reference prior and matching prior using a real-life example.

구심터빈의 노즐 내부 유동에 대한 시험 연구 (An Experimental Study on Flow in the Nozzle of a Radial Turbine)

  • 강정식;임병준;안이기
    • 한국유체기계학회 논문집
    • /
    • 제13권1호
    • /
    • pp.35-41
    • /
    • 2010
  • Experimental study on the flow field inside the nozzle for radial turbine was performed. At design point, the pressure is high and the Mach number is low at the pressure side of the nozzle inlet semi-vaneless space as the flow turns through the nozzle vanes. As the flow accelerates through the nozzle passage to the throat the pressure level at the pressure and suction sides becomes similar. The flow continued accelerating from the throat to the inlet of turbine wheel and the pressure field became uniform in the circumferential direction in the vaneless space. In high expansion ratio condition, strong favorable pressure gradient band region occurred just after the throat in the semi-vaneless space in the circumferential direction and the pressure became uniform in the circumferential direction after this band. In low expansion ratio condition, core flow acceleration is dominant after the throat and this non-uniform pressure field reached to the inlet of turbine wheel.

왜곡률을 이용한 고정자 권선고장 자동진단 (Automatic Diagnosis for Stator Winding Faults Using Distortion Ratio)

  • 송명현;박규남;한동기;양철오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.358-360
    • /
    • 2007
  • In this paper, an auto-diagnosis method of the stator winding fault for small induction motor is suggested. 3-phase stator currents are sampled, filtered, and transformed with Park's vector transformation. After then Park's vector patterns are obtained. To detect the stator winding fault automatically, a distortion ratio (id/iq) is newly defined and compared with the one of healthy motor, and the threshold levels are suggested. The 2-turn, 4-turn, 8-turn winding fault are tested with no load, 25%, 50%, 75%, and 100% rated load. The distortion ratio of the Park's vector patterns are increased as the increase of the faulted turns, but are same as the increase of the load.

  • PDF

On Second Order Probability Matching Criterion in the One-Way Random Effect Model

  • Kim, Dal Ho;Kang, Sang Gil;Lee, Woo Dong
    • Communications for Statistical Applications and Methods
    • /
    • 제8권1호
    • /
    • pp.29-37
    • /
    • 2001
  • In this paper, we consider the second order probability matching criterion for the ratio of the variance components under the one-way random effect model. It turns out that among all of the reference priors given in Ye(1994), the only one reference prior satisfies the second order matching criterion. Similar results are also obtained for the intraclass correlation as well.

  • PDF

순간주파수 분석기법의 응용 (2) -주파수의 부호를 결정하는 조건- (Application of Instantaneous Frequency Analysis(II) -Conditions of Existing Negative Frequency Components-)

  • 김정태;임병덕
    • 대한기계학회논문집
    • /
    • 제18권4호
    • /
    • pp.1057-1063
    • /
    • 1994
  • An instantaneous frequency analysis is a technique to examine a signature for the rotating machinery if the signal has several transitions within a cycle. This paper discusses the conditions of existing negative frequency components in the instantaneous frequency. By using a signal consisted of two frequency components, the instantaneous frequency analysis is conducted while the amplitude ratio between two frequency components has been changed. The analysis shows that, depending on the amplitude ratio, the instantaneous frequencies have averaged, zero-valued, or negative components. It turns out that the negative-valued instantaneous frequencies, which have been regarded as the noise effect, are the consequence of the calculation process for the multisignal components. The criteria of existing the negative values in instantaneous frequencies is given in terms of the relative amplitude ratio and the frequency difference. Especially when the amplitude ratio approaches to 1, the instantaneous frequency fluctuates ${\pm}\infty$ in theory, which implies that instantaneous frequency has unstable region around the amplitude ratio, 1.Also, as the frequency difference between major signal components is increased, the region of existing negative instantaneous becomes broader. In an instantaneous frequency analysis, therefore, a narrow band analysis is suggested, with extreme care if the amplitude ratio approaches to 1. In this paper, a vibration signal monitored from a rotating machinery is also examined as an application example in order to show the existence of negative instantaneous frequencies components.

Step-up and Step-down Asymmetrical 24-Pulse Autotransformer Rectifier

  • Zhang, Lu;Ge, Hong-juan;Jiang, Fan;Yang, Guang;Lin, Yi
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1536-1544
    • /
    • 2018
  • The existing 24-pulse autotransformer rectifier unit (ATRU) needs interphase reactors for parallel work of the rectifier bridges, and its output voltage cannot be regulated. Aiming at these problems, a step-up and step-down asymmetrical 24-pulse ATRU is proposed in this paper. The connections and turns ratios among transformer windings are well designed. In addition, a 15-degree phase difference is formed between two of the 24 voltage vectors produced by the transformer, which makes the four rectifier bridge groups produce a 24-pulse DC voltage without interphase reactors. Meanwhile, by adding extended winding to each phase of the transformer, wide-range regulation of the ATRU output voltage can be realized, and the reasonable voltage regulation range is between 0.2 and 1.6. The superposition of the voltage vectors and the principle of the voltage regulation are analyzed in detail. Furthermore, the turns ratio of the windings, winding current, output voltage, and kilovolt-ampere rating are all derived. Finally, the simulations and experiments are carried out, and the correctness of the principle and theoretical analysis of the new 24-pulse ATRU are verified.