• Title/Summary/Keyword: Turbulent Premixed Burner

Search Result 31, Processing Time 0.022 seconds

Reaction Zone Thickness of Turbulent Premixed Flame

  • Yamamoto, Kazuhiro;Nishizawa, Yasuki;Onuma, Yoshiaki
    • Journal of the Korean Society of Combustion
    • /
    • v.6 no.2
    • /
    • pp.36-42
    • /
    • 2001
  • Usually, we use the flame thickness and turbulence scale to classify the flame structure on a phase diagram of turbulent combustion. The flame structure in turbulence is still in debate, and many studies have been done. Since the flame motion is rapid and its reaction zone thickness is very thin, it is difficult to estimate the flame thickness. Here, we propose a new approach to determine the reaction zone thickness based on ion current signals obtained by an electrostatic probe, which has enough time and space resolution to detect flame fluctuation. Since the signal depends on the flow condition and flame curvature, it may be difficult to analyze directly these signals and examine the flame characteristics. However, ion concentration is high only in the region where hydrocarbon-oxygen reactions occur, and we can specify the reaction zone. Based on the reaction zone existing, we estimate the reaction zone thickness. We obtain the thickness of flames both in the cyclone-jet combustor and on a Bunsen burner, compared with theoretically predicted value, the Zeldovich thickness. Results show that the experimentally obtained thickness is almost the same as the Zeldovich thickness. It is concluded that this approach can be used to obtain the local flame structure for modeling turbulent combustion.

  • PDF

An Experimental Study on Turbulent Counter Jet Flame near Stagnation Point (대향 제트 정체점 주변의 난류 화염에 관한 연구)

  • Ko, Il-Min;Seo, Jeong-Il;Hong, Jung-Goo;Shin, Hyun-Dong
    • 한국연소학회:학술대회논문집
    • /
    • 2006.04a
    • /
    • pp.128-134
    • /
    • 2006
  • A characterization of turbulent reacting flows has proved difficult owing to the complex interaction between turbulence, mixing, and combustion chemistry. There are many types of time scales in turbulent flame which can determine flame structure. This counter jet type premixed burner produces high intensity turbulence. The goal is to gain better insights into the flame structures at high turbulence. 6 propane/air flames gave been studied with high velocity fluctuation in bundle type nozzle and in one hole type nozzle. By measuring velocity fluctuation, turbulent intensity and integral length scale are obtained. And sets of OH LIF images were processed to see flame structure of the mean flame curvatures and flame lengths for comparison with turbulence intensity and turbulent length scales. The results show that the decrease in nozzle size generates smaller flow eddy and mean curvatures of the flame fronts, and a decrease in Damkohler number estimated from flow time scale measurement.

  • PDF

Prediction of Spatial Heat Release Rate of Combustion Chamber by Radicals-PLIF (라디칼 PLIF계측을 이용한 연소실의 공간적 열발생율 예측)

  • Choi, G.M.
    • Journal of ILASS-Korea
    • /
    • v.8 no.4
    • /
    • pp.9-16
    • /
    • 2003
  • The Purpose of this study is to investigate the relationships between the local heat release rate and CH concentration have been investigated by numerical simulations of methane-air premixed flames. And simultaneous CH and OH PLIF(Planar Laser Induced Fluorescence) measurement has been also conducted for lean premixed flame as well as for laminar flames. Numerical simulations are conducted for laminar premixed flames and turbulent ones by using PREMIX in CHEMKIN and two dimensional DNS code with GRI mechanism version 2.11, respectively. In the case of laminar premixed flame, the distance between the peak of heat release rate and that of CH concentration is under $91{\mu}m$ for all equivalence ratio calculated in present work. Even for the premixed flame in high intensity turbulence, the distribution of the heat release rate coincides with that of CH mole fraction. For CH PLIF measurements in the laminar premixed flame burner, CH fluorescence intensity as a function of equivalence ratio shows a similar trend with CH mole fraction computed by GRI mechanism. Simultaneous CH and OH PLIF measurement gave us useful information of instantaneous reaction zone. In addition, CH fluorescence can be measured even for lean conditions where CH mole fraction significantly decreases compared with that of stoichiometric condition. It was found that CH PLIF measurements can be applicable to the estimation of the spatial fluctuations of heat release rate in the engine combustion.

  • PDF

Development of a 3-Dimensional Turbulent Reaction Computer program for the Incineration of a Carbon Tetrachloride($CCl_4$) ( I ) (사염화탄소($CCl_4$) 소각을 위한 로타리 킬른 소각로 3차원 난류반응 컴퓨터 프로그램 개발( I ))

  • 엄태인;장동순
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.1
    • /
    • pp.100-109
    • /
    • 1994
  • In this study, it is investigated that the possibility of the numerical simulation for the incineration of the hazardous material, crbon tetrachloride($CCl_4$). A 3-dimensional numerical technology is applied for turbulent reacting flows of the full-scale Dow Chemical incinerator. The calculations are made by a CRAY-2S, super computer. The major parameters considered in this study are kiln revolution rate (rpm), filling ratio of the solid waste(f), burner Injection velocity and angle, and turbulent air jets for swirl. And the employed turbulent reaction model is the eddy break-up model which is a kind of fast chemistry model assuming general equilibrium and used for a premixed flame. The calculated flow fields are presented and discussed. 1) The presence of turbulent air nozzles for swirl gives rise to visible increase of the convective motion over the region of the solid waste. This implies the possibility to enhance the mixing of the waste with the surrounding all and thereby to reduce thermal and species stratification, which were reported in a large rotary kiln operation. 2) Considering that the location of the recirculation region has a strong relation with the heating rate of the solid waste, the control of the recirculation region by the burner injection angle Is quite desirable in the sense of the flexible design of the rotary kiln incinerator for a carbon tetrachloride. 3) Finally, it is found that the eddy break-up model Is not suitable for carbon tetrachloride($CCl_4$) because this model is not incorporated the flame inhibition trend due to the presence $CCl_4$compound.

  • PDF

An Experimental study on characteristics of flame chemiluminescence using multi channel photo diode (다채널 포토다이오드를 이용한 화염 자발광 특성에 대한 실험적 연구)

  • Jang, Byunghwa;Kwon, Minjun;Kim, Daehae;Lee, Changyeop;Kim, Sewon
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.319-320
    • /
    • 2015
  • This study is aiming to establish the relationship between the optical signal of flame through an optical fiber and the equivalent ratio of flame. In this experiment, flame optical signal in a furnace is measured using photodiode. The combustion system is composed of 15W turbulent burner and industrial boiler, and flame chemiluminescence is measured at various experimental conditions. In this study, the flame chemiluminescence of turbulent premixed flame is measured using commercially available photodiode. It is experimentally investigated the relationship between equivalent ratio and photodiode signal.

  • PDF

Local Concentration and Flame Temperature Characteristics of Combustion Product in Premixed LPG/Air Flames (예혼합 LPG/공기화염에서 연소생성물의 국소농도 및 화염온도특성)

  • 김태권;장준영
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.4
    • /
    • pp.77-84
    • /
    • 2001
  • Measurements of local CO, $CO_2$, $O_2$, $N_2$, $C_3$H$_{8}$, NOx concentrations and flame temperature are made for partially premixed flame with and without acoustic excitation. The CO, $CO_2$, $O_2$, $N_2$, and $C$_3$H_8$ concentrations are determined by thermal conductivity detection (Gas-chromatograph) and NOx concentrations are determined by chemiluminescent detection (NOx analyser). To measure local sample concentration, sampling probe was made by quartz with inlet diameter of 0.25mm. In the case of excitation, the visual shape of the flame is changed from laminar flame to turbulent-like flame. The flame length is also reduced, and the flame width becomes broad. In the observation of emission concentration without acoustic excitation, meanwhile, the $CO_2$ and NOx concentrations peak at flame front where the mixture meets with surrounding air, and the CO concentration is increasing at maximum position of CO2 concentration and peaks at the centerline of the burner. In the case of acoustic excitation, the $CO_2$ concentration is widely occurred at nozzle of the burner and is higher relative to unexcitation. The CO concentration is much reduced, but NOx concentration is more increasing. And flame temperature is higher relative to unexcitation. These are caused by enhancing of mixing with surrounding air due to excitation. However, in the case of acoustic excitation, the total NOx concentration is reduced because of the shortened flame length which affects residence time.e.

  • PDF

Development of Hybrid/Dual Swirl Jet Combustor for a MGT (Part II: Numerical Study on Isothermal Flow) (마이크로 가스터빈용 하이브리드/이중 선회제트 연소기 개발 (Part II: 비반응 유동에 관한 수치해석))

  • Mun, Sun-Yeo;Hwang, Cheol-Hong;Lee, Kee-Man
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.5
    • /
    • pp.70-79
    • /
    • 2013
  • The isothermal flow structure and mixing characteristics of a hybrid/dual swirl jet combustor for micro-gas turbine (MGT) were numerically investigated. Location of pilot burner, swirl angle and direction were varied as main parameters with the identical thermal load. As a result, the variations in location of pilot nozzle, swirl angle and direction resulted in the significant change in turbulent flow field near burner exit, in particular, center toroidal recirculation zone (CTRZ) as well as turbulent intensity, and thus the flame stability and emission performance might be significantly changed. With the comparison of experimental results, the case of swirl angle $45^{\circ}$ and co-swirl flow including optimum location of pilot burner were chosen in terms of the flame stability and emissions for the development of hybrid/dual swirl jet combustor.

Numerical Study on the Flow and Combustion Characteristics in Swirl-Premix Burners (스월 예혼합 버너의 유동 및 연소특성에 관한 수치적 연구)

  • Lim, Jun-Seok;Lee, Jong-Hyeok;Baek, Gwang-Min;Cho, Ju-Hyeong;Kim, Han-Seok;Sohn, Chae-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.1
    • /
    • pp.103-110
    • /
    • 2012
  • The flow field, fuel-air mixing, and behaviors of turbulent flames have been investigated using the large eddy simulation (LES) numerical technique in a premixed swirl combustor equipped with EV double cone burners. Recirculation zones are generated by the swirl burner, and lean premixed flames are formed within a distance of 0.2 m from the tip of the burner. NOx emission of 0.46 ppm is predicted at 1 atm and an air/fuel ratio of 38.7. However, most of the CO generated in a flame front continues to be oxidized as it moves toward the exit, and CO emission of 5.45 ppm is predicted at the exit. The NOx emission can be reduced by decreasing the pressure and air/fuel ratio. The characteristics of NOx emission have been investigated through RANS simulations for various fuel injection types, and it is found thereby that five-lance-hole injection produces the lowest NOx emission rate.

Effect of Diluents and Oxygen-Enrichness on the Stability of Nonpremixed Flame (산소부화와 희석제에 따른 비예혼합 화염의 안정성)

  • 배정락;이병준
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.10
    • /
    • pp.1458-1464
    • /
    • 2002
  • $CO_2$ is well known greenhouse gas which is the major source of global warming. Reducing $CO_2$ emission in combustion process can be achieved by increasing combustion efficiency, oxygen enriched combustion and recirculation of the emitted $CO_2$ gas. Stability of non-premixed flame in oxygen enriched environment will be affected by the amount of oxygen, kind of diluents and fuel exit velocity. The effects of these parameters on flame liftoff and blowout are studied experimentally oxidizer coflowing burner. Experiments were divided into three cases according as where $CO_2$gas was supplied. - 1) to coflowing air, 2) to fuel with 0$_2$-$N_2$ coflow, 3) to coflowing oxygen. Flame in air coflowing case was lifted in turbulent region. Flame lift and blowout in laminar region with the increase in $CO_2$ volume fraction in $CO_2$-Air mixture makes flame lift and blowout in laminar region. Increase in oxygen volume fraction makes flame stable-i.e. flame liftoff and blowout occur at higher fuel flowrates. Liftoff height was non-linear function of nozzle exit velocity and affected by the $O_2$ volume fraction. It was found that the flame in $O_2$-$N_2$ coflow case was more stable than $O_2$-$CO_2$ case, Liftoff heights vs (nozzle exit velocity/laminar burning velocity)$^{3.8}$ has a good correlation in $O_2$-$CO_2$ oxidizer case.

A Study on the Structure of Turbulent non-Premixed Oxy-fuel Flame Using CMC Model-based Simulation (CMC 모델 기반 수치해석을 사용한 순산소 난류확산화염 구조 연구)

  • Kim, Jong-Soo;Sreedhara, S.;Huh, Kang-Yeol;Yang, Won
    • Journal of the Korean Society of Combustion
    • /
    • v.13 no.1
    • /
    • pp.31-43
    • /
    • 2008
  • Oxy-fuel flame has a significantly different structure from that of air-fuel flame because of its high temperature. This study is aimed to find out the difference of the oxy-fuel flame structure in order to understand reaction mechanism closely, which is crucial to design real-scale oxy-fuel combustion system. By examining pictures of counterflow flame and LIF images, we found that oxy-fuel flame had two-zone structure: fuel decomposition region and distributed CO oxidation region. In the oxy-fuel flame, OH radical was distributed intensely through the whole flame due to its higher flame temperature than crossover temperature. For showing those features of the oxy-fuel flame, 1 MW scale IFRF oxy-natural gas burner was simulated by conditional moment closure(CMC) model. Calculation results were compared with experimental data, and showed agreements in trend. In the simulated distributions of fuel decomposition/CO oxidation rates, CO oxidation region was also separated from fuel decomposition zone considerably, which showed the two-zone structure in the oxy-fuel flame.

  • PDF