• Title/Summary/Keyword: Turbulent Noise

Search Result 203, Processing Time 0.023 seconds

FIV Characteristics of U-Tubes Due to Relocation of the Tube Supprot Plates (튜브 지지판 재배치에 따른 유체유발진동 특성 해석)

  • Kim, Hyung-Jin;Ryu, Ki-Wahn;Park, Chi-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.312-317
    • /
    • 2005
  • Fluid-elastic instability and turbulence excitation for an under developing steam generator are investigated numerically. The stability ratio and the amplitude of turbulence excitation are obtained by using the PIAT (Program for Integrity Assessment of Steam Generator Tube) code from the information on the thermal-hydraulic data of the steam generator. The aspect ratio, the ratio between the height of U-tube from the upper most tube support plate (h) and the width of two vertical portion of U-tube (w), is defined for geometric parameter study. Several aspect ratios with relocation of tube support plates are adopted to study the effects on the mode shapes and characteristics of flow-induced vibration. When the aspect ratio exceeds value of 1, most of the mode shapes at low frequency are generated at the top of U-tube. It makes very high value of the stability ratio and the amplitude of turbulent excitation as well. We can consider that the local mode shape at the upper side of U-tube will develop the wear phenomena between the tube and the anti-vibration bars such as vertical, horizontal, and diagonal strips. It turns out that the aspect ratio reveals very important parameter for the design stage of the steam generator. The appropriate value of the aspect ratio should be specified and applied.

  • PDF

Effect of Boundary Layer Generated on the fin surfaces of a Compact Heat Exchanger on the Heat Transfer and Pressure Drop Characteristics (컴팩트형 열교환기의 핀 표면에서 발생하는 경계층이 열교환기의 전열 및 압력강하 특성의 변화에 미치는 영향에 관한 수치해석적 연구)

  • KIM Chul-Ho;Jung Ji-Yong
    • Journal of computational fluids engineering
    • /
    • v.3 no.1
    • /
    • pp.82-88
    • /
    • 1998
  • As a par of a project related to the development of the design algorithm of a compact heat exchanger for the application of the electronic home appliances, the effect of the discreteness of the airflow boundary generated on the cooling fin surface on the heat transfer and pressure drop characteristics of the heat exchanger was studied numerically. In general, there are two critical design parameters seriously considered in the design of the heat exchanger; heat transfer rate(Q) and pressure drop coefficient(C/sub p/). Even though the higher heat transfer rate with lower pressure drop characteristics is required in a design of the heat exchanger, it is not an easy job to satisfy both conditions at the same time because these two parameters are phenomenally inversely proportional. To control the boundary layer thickness and its length along the streamline, the surface of the flat fin was modified to accelerate the heat transfer rate on the fin surface. To understand the effect of the discreted fin size(S/sub w/) and its location(S/sub h/) on the performance of the heat exchanger in the airflow field, the flat fin was modified as shown in Fig. 1. From this study, it was found that the smaller and more number of slits on the fin surface showed the higher energy diffusion rate. It means that the discreteness of the boundary layer is quite important on the heat transfer rate of the heat exchanger. On the other hand, if the fin surface configuration is very complex than needed, higher static pressure drop occurs than required in a system and it may be a reason of the induced aerodynamic noise in the heat exchanger.

  • PDF

A Study on the 3-Dimensional Implementation of Computer-Aid Management of Stereo Images (입체 화상의 3차원 전산모사기 구현에 관한 연구)

  • Lee, Joong;Yoon, Do-Young
    • Korean Chemical Engineering Research
    • /
    • v.47 no.2
    • /
    • pp.179-184
    • /
    • 2009
  • Recent evolution of computer technology enhances the effectiveness of CFD(Computational Fluid Dynamics) analysis for the 3-dimensional complex transport phenomena including turbulent flows. Cheaper and easier than laser and ultra-sonic methods, the windows simulator name by CAMSI(Computer-Aided Management of Stereo Images) has been developed in order to implement the 3-dimensional image using a disparity histogram extracted from left and right stereo images. In our program using the area-based method, the matching pixel finding methods consist of SSD(Sum of Squared Distance), SAD(Sum of Absolute Distance), NCC(Normalized Correlation Coefficient) and MPC(Matching Pixel Count). On performing the program, stereo images on different window sizes for various matching pixel finding methods are compared reasonably. When the image has a small noise, SSD on small window size is more effective. Whereas there is much noise, NCC or MPC is more effective than SSD. CAMSI from the present study will be much helpful to implement the complex objects and to analyze 3-dimensional CFD around them.

The Strap Vibration Characteristics in $5{\times}5$ Grid Exposed to Axial Flow (축방향 유속에 노출된 $5{\times}5$ 지지격자 스트랩의 진동특성)

  • Kim, Kyoung-Hong;Park, Nam-Gyu;Kim, Kyoung-Ju;Suh, Jung-Min
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.911-916
    • /
    • 2012
  • It is important to identify dynamic characteristics of nuclear fuel components. Since the fuel always exposed to turbulent flow, the dynamic contact between grids and rods is one of the fuel failure modes. The dynamic behavior of grids in nuclear fuels is quite complex, since two pairs of spring support are placed in the limited space. The strap in a cell has single spring and double dimples and this paper focuses on investigation of the grid strap(Test Fuel Strap, TFS) vibration in one cell. To identify the grid strap vibration, modal analysis of the strap is performed using Finite Element Method (FEM). Modal testing on a $5{\times}5$ grid structure without rods is performed. The modal testing results are compared to analytic results. In addition, random test considering rod effect is performed about a $5{\times}5$ grid with rods under real contact condition in the air. Finally, the strap vibration of a $5{\times}5$ fuel bundle in INvestigation of Flow INduced vIbraTion(INFINIT) facility is measured in real fluid velocity condition without heating. It is shown that modal frequencies from the test are almost equal to those peak frequencies in the INFINIT test.

  • PDF

FIV Analysis of SG Tubes for Various TSP Locations (튜브 지지판 재배치에 따른 유체유발진동 특성 해석)

  • Kim, Hyung-Jin;Park, Chi-Yong;Park, Myoung-Ho;Ryu, Ki-Whan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.9 s.102
    • /
    • pp.1009-1015
    • /
    • 2005
  • Fluid-elastic instability and turbulence excitation for an under developing steam generator are investigated numerically. The stability ratio and the amplitude of turbulence excitation are obtained by using the $PIAT^{(R)}$ (program for integrity assessment of steam generator tube) code from the information on the thermal-hydraulic data of the steam generator. The aspect ratio, the ratio between the height of U-tube from the upper most tube support Plate (h) and the width of two vertical portion of U-tube (w), is defined for geometric parameter study. Several aspect ratios with relocation of tube support plates are adopted to study the effects on the mode shapes and characteristics of flow-induced vibration. When the aspect ratio exceeds value of 1, most of the mode shapes at low frequency are generated at the top of U-tube. It makes very high value of the stability ratio and the amplitude of turbulent excitation as well. We can consider that the local mode shape at the upper side of U-tube will develop the wear phenomena between the tube and the anti-nitration bars such as vortical, horizontal, and diagonal strips. It turns out that the aspect ratio reveals very important parameter for the design stage of the steam generator. The appropriate value of the aspect ratio should be specified and applied.

Numerical Study on Submersible Pumps with a Vortex Reduction Function (와류저감기능이 적용된 수중펌프에 관한 수치적 연구)

  • Ahn, Deog-Inn;Kim, Hong-gun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.10
    • /
    • pp.83-92
    • /
    • 2019
  • A pump is considered to be submersible when a motor and a pump are integrated and operate while submerged in water. Submersible pumps mainly function as rejection pumps to prevent foods in densely populated areas, as cold water circulation pumps in large power plants, as pumps to supply irrigation water, as drainage pumps to prevent flooding of agricultural lands, as water supply intake pumps, and as inflow pumps for sewage treatment. The flow in such turbomachines (submersible pumps) inevitably involves various eddy currents. Since it is almost impossible to accurately grasp the complex three-dimensional flow structure and characteristics of a rotating turbomachine through actual testing, three-dimensional numerical analysis using computational fluid dynamics techniques measuring the flow field, velocity, and the pressure can be accurately predicted. In this study, the shape of the impeller was developed to reduce vibration and noise. This was done by increasing the efficiency of the existing submersible pump and reducing turbulence. In order to evaluate the pump's efficiency and turbulence reduction, we tried to analyze the flow using ANSYS Fluent V15.0, a commercial finite element analysis program. The results show that the efficiency of the pump was improved by 4.24% and the Reynolds number was reduced by 15.6%. The performance of a developed pump with reduced turbulence, vibration, and noise was confirmed.

Performance Assessment of Turbulence Models for the Prediction of Tip Leakage Flow in an Axial-Flow Turbomachinery (축류형 유체기계에서 익단 누설 유동 해석을 위한 난류 모델 성능 평가)

  • Lee, Gong-Hee;Baek, Je-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.12
    • /
    • pp.1655-1666
    • /
    • 2003
  • It is experimentally well-known that high anisotropies of the turbulent flow field are dominant inside the tip leakage vortex, which is attributable to a substantial proportion of the total loss and constitutes one of the dominant mechanisms of the noise generation. This anisotropic nature of turbulence invalidates the use of the conventional isotropic eddy viscosity turbulence models based on the Boussinesq assumption. In this study, to check whether an anisotropic turbulence model is superior to the isotropic ones or not, the results obtained from the steady-state Reynolds averaged Navier-Stokes simulations based on the RNG k-$\varepsilon$ model and the Reynolds stress model (RSM) are compared with experimental data for two test cases: a linear compressor cascade and a forward-swept axial-flow fan. Through this comparative study of turbulence models, it is clearly shown that the RSM, which can express the production term and body-force term induced by system rotation without introducing any modeling, should be used to predict quantitatively the complex tip leakage flow, especially in the rotating environment.

Development of a High Resolution Cinematic Particle Image Velocimetry and Its Application to measurement of Unsteady Complex Turbulent Flows (고분해능 Cinematic PIV 시스템의 개발과 비정상 복잡 난류유동측정에의 응용)

  • Kim, Kyung-Chun;Park, Kyung-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.536-541
    • /
    • 2001
  • A high resolution digital cinematic Particle Image Velocimetry(PIV) has been developed. The system consists of a high speed CCD camera, a continuous Ar-ion laser and a computer with camera controller. To improve the spatial resolution, we adopt a Recursive Technique for velocity interrogation. At first, we obtain a velocity vector for a larger interrogation window size based on the conventional two-frame cross-correlation PIV analysis using the FFT algorithm. Based on the knowing velocity information, more spatially resolved velocity vectors are obtained in the next iteration step with smaller interrogation windows. The correct velocity vector at the first step is found to be critical, so we apply a Multiple Correlation Validation(MCV) technique in order to decrease the spurious vectors. The MCV technique turns out to improve SNR(Signal to Noise Ratio) of the correlation table. The developed cinematic PIV method has been applied to the measurement of the unsteady flow characteristics of a Rushton turbine mixer. A total of 3,245 instantaneous velocity vectors were successfully obtained with 4 ms time resolution. The acquired spatial resolution corresponds the performance of the conventional high resolution digital PIV system using a $1K{\times}1K$ CCD camera.

  • PDF

Numerical study on attenuation and distortion of compression wave propagation into a straight tube (직관내를 전파하는 압축파의 감쇠와 변형에 관한 수치해석적 연구)

  • Kim, Hui-Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.7
    • /
    • pp.2315-2325
    • /
    • 1996
  • A compression wave is attenuated or distorted as it propagates in a tube. The present study investigated the propagation characteristics of the compression waves which are generated by a train in a high-speed railway tunnel. A Total Variation Diminishing (TVD) difference scheme was applied to one-dimensional, unsteady viscous compressible flow. The numerical calculation involved the effects of wall friction, heat transfer and energy loss due to the friction heat in the boundary layer behind the propagating compression wave, and compared with the measurement results of a shock tube and a real tunnel. The present results show that attenuation of the compression wave in turbulent boundary layer is stronger than in laminar boundary layer, but nonlinear effect of the compression wave is greater in the laminar boundary layer. The energy loss due to the frictional heat had not influence on attenuation and distortion of the propagating compression waves.

A Study on Mean Flow Velocity Measurement by Cross Correlation of Ultrasonic Waves (초음파 상호상관 기법을 이용한 유체의 평균유속 측정 연구)

  • Kim, Chang-Ho;Lee, Dug-Ki;Paik, Jong-Seung;Jho, Moon-Jae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.5-15
    • /
    • 1995
  • An application of the cross correlation technique by adopting ultrasonic waves for water pipe flow measuring purpose is studied. It is a non-intrusive flow metering method by determining the time of the flight of the flow turbulent noise and its non-obstructing mechanism enables to reduce process energy loss due to the flowmeter obstruction. A digital signal processor for the purpose of the real time Fourier transform was employed for the fast time calculation of the flow velocity. The overall accuracy was found as about $1\%$ for flow velocities from 0.25 m/s up to 16 m/s and for the pipe inside diameters from 50mm to 248mm. The cross correlation technique can be used for the tap water utility including most common liquid flows.

  • PDF