• 제목/요약/키워드: Turbine case

검색결과 498건 처리시간 0.029초

증기터빈$\cdot$발전기축계의 지진응답해석 (제2보 : 웨이블렛 해석의 적용) (Seismic Response Analysis of Steam Turbine-Generator Rotor System (2nd Report, Application of Wavelet Analysis))

  • 양보석;김병욱;김용한
    • 소음진동
    • /
    • 제9권4호
    • /
    • pp.813-821
    • /
    • 1999
  • This paper presents the technique using wavelet analysis to solve the seismic response of a steam turbine-generator rotor system subjected to earthquake excitations. A brief review of the wavelet transform and its discretization, time-frequency representation of the earthquake wave and the seismic response for a rotor system is presented. The Daubechies wavelet has been used for describing the time-frequency characteristics of the input and the response in case of a recorded accelerogram during 1995 Hyogoken Nanbu earthquake. Also, the results in the wavelet domain has been illustrated through comparison with the time domain simulation results.

  • PDF

IGCC 가스터빈 운전조건에서의 석탄가스 층류화염속도에 대한 기초연구 (Numerical Investigations on Laminar Flame Speed of Syngas Flames at IGCC Gas Turbine Condition)

  • 이정원;오경택;김용모
    • 한국연소학회지
    • /
    • 제16권4호
    • /
    • pp.38-45
    • /
    • 2011
  • Coal-derived syngas has been utilized by main fuel at IGCC power plant. Research efforts for investigating the characteristics of premixed and nonpremixed flames at gas-turbine condition have been conducted. The present study has been mainly motivated to evaluate the capability of the detailed chemical kinetics to predict the syngas laminar flame speed. Special emphasis is given to the effects of pressure, temperature, syngas composition, and dilution level on the characteristics of premixed and nonpremixed flames. The predicative capability of a number of detailed mechanism for laminar flame speed is compared to experimental data. From these results, detailed kinetics of Davis et al. and Li et al. have the best conformity with the experiments in the all the case of parametric studies.

증기터빈 디지털 제어 시스템 통신 사양 고찰 (A Study of communication specification of a steam turbine digital control system)

  • 서중석;육심균;조창호;정창기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 B
    • /
    • pp.752-754
    • /
    • 1999
  • When we are trying to retrofit turbine control system from analog system to digital one, a new communication network is required to be contstructed. In this paper, we are going to introduce one example of economic communication network, which is reliable in operation from control room and field instruments to office and computer room. It will be installed in a power plant in the case of retrofiting control system of medium size steam turbine.

  • PDF

Performance comparison of 10kW scale horizontal axis tidal turbines

  • Hoang, A.D.;Yang, C.J.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권5호
    • /
    • pp.541-549
    • /
    • 2014
  • Horizontal axis tidal turbines are machinery inherited from the principle of wind turbines to enable the application of utilizing ocean's current energy. Its function does not differ from that of wind case, which is to convert fluid's kinetics energy to mechanical torque, therefore generates electricity. Since the ocean has been an enormous source of untapped power, tidal turbines have been being investigated recently to meet human's demand of energy with respect to environment friendly approach. This paper introduces a couple of turbine designs which are anticipated to have high performance. A comparison among recent works on the same topic is also made for validation.

발전용 대형 가스터빈 축류압축기 설계 특성 분석 (Analysis of Axial Compressor Design Characteristics in Large Class Gas Turbine for Power Generation)

  • 이성룡;송재욱;김수용
    • 한국유체기계학회 논문집
    • /
    • 제15권1호
    • /
    • pp.64-69
    • /
    • 2012
  • Currently axial flow compressor is used primarily in a large power generation gas turbine. In this paper,the main factors to be considered when designing a axial flow compressor were compared to those of a small power generation gas turbine(DGT-5). The main design parameters was examined in the aspect ratio, solidity, as well as reaction, diffusion factor, incidence angle, etc. The results in case of a small compressor are showed a regular pattern but there were not found any specific design patterns for a large class compressor.

부유식 해상 풍력 발전기의 최적 형상 설계에 관한 연구 (A Study on the Optimal Shape Design of a Floating Offshore Wind Turbine)

  • 박정훈;신현경
    • 대한조선학회논문집
    • /
    • 제52권3호
    • /
    • pp.171-179
    • /
    • 2015
  • Usually, in case of wind turbines on land, there are a lot of constraints for installation such as the insufficient installation space and noise pollution. On March 11, 2011, a nuclear leakage accident occurred due to the tsunami caused by the earthquake in Japan and then there have been a rapidly growing interest in floating offshore wind turbines. In this study, an optimization of the substructure of a semi-submersible type floating offshore wind turbine was made. Design variables were set and design alternatives were fixed. UOU-FAST was used for motion analysis in combined environmental conditions of waves and wind. Response Amplitude Operators(RAOs) were compared between the design alternatives.

터빈 로터강의 피로크랙전파속도의 확률특성 연구( I ) (A Study on the Statistical Characterisics of Fatigue Crack Propagation Rate in Turbine Rotor Steel(I))

  • 오세욱;이치우;정순호
    • 한국해양공학회지
    • /
    • 제1권2호
    • /
    • pp.83-92
    • /
    • 1987
  • Inorder ot estimate the running life of turbine rotors, fatigue crack propagation low, da/dN = C(${\DELTA}K)^m$, proposed by paris et al. has been widely applied. In this study, fatigue crack propagation rates for 16 samples of 1% Cr-Mo-V rotor steel were measured and statistical characteristics of m and C values in above equation were reviewed. The results are summarized as follows. 1. C and m follow a log-normal distribution and normal distribution, respectively. And the relation of C and shows a strong negative correlation. 2. Fatigue crack propagation equation can be expressed as da/dN=$4.11{\times}10^{-4}({\Delta}K/153.8)^m$, introducing the ralationship C=$C_oK_o^{-m}$. In this case, contribution of $C_o$ distribution to the distribution of log C shows very small compared to degrees of contribution by m.

  • PDF

풍력발전기의 확률론적 발전비용 절감기여도 평가 (Probabilistic Production Cost Credit Evaluation of Wind Turbine Generators)

  • 박정제;오량;최재석;차준민
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2153-2160
    • /
    • 2008
  • This paper develops an algorithm for probabilistic production cost credit evaluation of wind turbine generators(WTG) with multi-state. Renewable energy resources such as wind, wave, solar, micro hydro, tidal and biomass etc. are becoming importance stage by stage because of considering effect of the environment. Wind energy is one of the most successful sources of renewable energy for the production of electrical energy. Case study demonstrates that the wind speed credit in view point of economics can be assessed by using the proposed methodology.

가스터빈과 순산소 연소를 적용한 발전시스템의 성능해석 (Performance Analysis on Gas Turbine based Oxy-fuel Combustion Power Plants)

  • 이영덕;이상민;박준홍;유상석;안국영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.3169-3174
    • /
    • 2008
  • Future power plants will be required to adopt some type of carbon capture and storage (CCS) technologies to reduce their CO2 emissions. One of distinguished CCS techniques expected to resolve the green house effect is to apply the oxy-fuel combustion technique to power plant, and a lot of research/demonstration programs have been going on in the world. In this paper, CO2-capturing power plants based on gas turbine and oxy-fuel combustion are investigated over several types of configurations. As a prior step, simulation model for 500 MW-class combined cycle power plant was set and was used as a reference case. The efficiencies of several power plants was compared and the advantages and disadvanteges was investigated.

  • PDF

1.5kW급 풍력발전기용 블레이드의 구조해석 및 구조시험 (Structural Analysis and Testing of 1.5kW Class Wind Turbine Blade)

  • 김홍관;이장호;장세명;강기원
    • 한국유체기계학회 논문집
    • /
    • 제13권4호
    • /
    • pp.51-57
    • /
    • 2010
  • This paper describes the structural design and testing for 1.5kW class wind turbine composite blade. In order to calculate the equivalent material properties rule-of-mixture is applied. Lay-up sequence, ply thickness and ply angle are designed to satisfy the requirements for structural integrity. Structural analysis by using commercial software ABAQUS is performed to assess the static, buckling and vibration response. And to verify the structural analysis and design, the full scale structural test in flapwise direction was performed under single point loading according to loading conditions calculated by the aerodynamic analysis and Case H (Parked wind loading) in IEC 61400-2.