• 제목/요약/키워드: Turbine Performance Test

검색결과 448건 처리시간 0.032초

연료전지 수소재순환 이젝터 성능 해석 (Performance Analysis on a Hydrogen Recirculation Ejector for Fuel Cell Vehicle)

  • 남궁혁준;문종훈;장석영;홍창욱;이경훈
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.256-259
    • /
    • 2008
  • Ejector system is a device to transport a low-pressure secondary flow by using a high-pressure primary flow. Ejector system is, in general, composed of a primary nozzle, a mixing section, a casing part for suction of secondary flow and a diffuser. It can induce the secondary flow or affect the secondary chamber pressure by both shear stress and pressure drop which are generated in the primary jet boundary. Ejector system is simple in construction and has no moving parts, so it can not only compress and transport a massive capacity of fluid without trouble, but also has little need for maintenance. Ejectors are widely used in a range of applications such as a turbine-based combined-cycle propulsion system and a high altitude test facility for rocket engine, pressure recovery system, desalination plant and ejector ramjet etc. The primary interest of this study is to set up an applicable model and operating conditions for an ejector in the condition of sonic and subsonic, which can be extended to the hydrogen fuel cell vehicle. Experimental and theoretical investigation on the sonic and subsonic ejectors with a converging-diverging diffuser was carried out. Optimization technique and numerical simulation was adopted for an optimal geometry design and satisfying the required performance at design point of ejector for hydrogen recirculation. Also, some ejectors with a various of nozzle throat and mixing chamber diameter were manufactured precisely and tested for the comparison with the calculation results.

  • PDF

초음속 이젝터의 압력회복에 관한 연구 (Pressure Recovery in a supersonic ejector of a high altitude testing chamber)

  • 조지;공창덕
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.833-837
    • /
    • 2010
  • 본 연구는 최소 압력 모사로 엔진 배기가스를 배출시키기 위한 최적 이젝터 크기를 결정하기 위한 것을 목적으로 한다. 실험 챔버로 유입되는 2차 냉각 공기는 유량제어 밸브들과 진공펌프가 장착된 배출구를 통해 엔진배기가스는 분리되어 배출된다. 기존 고도시험 장치와 달리, 본 연구에 제안한 형상은 기존 이젝터의 압력 회복을 개선한 좀 더 작은 포획 면적을 가진 배기 이젝트를 사용하면 가스에 스텔링 챔버로 부터 20% 냉각 공기를 부가하여 배출시키도록 크기가 정해진다. 제안된 형상은 벨마우스 이젝터와 엔진배기 출구의 면적비가 이론적으로 약 1.2를 갖는다. 제안된 형상의 혼합 공기 모사결과에 따르면 큰 에너지는 기존 시스템 비해 좀 더 개선된 압력 회복과 감소된 전력 소모를 같음을 확인하였다.

  • PDF

HIL 기반 LNGC PMS 시뮬레이터의 성능 검증 (HIL based LNGC PMS Simulator's Performance Verification)

  • 이광국;박재문
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.219-220
    • /
    • 2016
  • 전력 관리 시스템인 PMS는 선박 통합 제어 시스템에서 중요한 역할을 한다. 본 연구에서는 액화 천연가스선의 PMS를 검증하기 위해서 실시간 HIL 시뮬레이션을 구현한다. 시뮬레이터는 터빈 발전기 디젤발전기, 차단기, 주요 3상 부하로 구성되고, 이들 모델은 MATLAB/Simulink로 구현한다. 더불어 FPGA 기반 제어 콘솔과 메인 스위치보드를 구축하여 선박에 탑재 되어 있는 LNGC PMS 제어 환경을 모사 한다. PMS 기능 검증을 위해 LNGC 내 주요 전력소모원 대비 두 가지 전력 분배 모드를 테스트 케이스로 수행한다. 그 결과 본 연구에서 제안한 시스템은 PMS 시뮬레이터로써 시운전 테스트뿐만 아니라 오류 주입 검증용으로 사용될 것이다.

  • PDF

산업장 교대근무 근로자의 건강증진행위 예측요인 (Predictive Factors of Health promotion behaviors of Industrial Shift Workers)

  • 김영미
    • 한국직업건강간호학회지
    • /
    • 제11권1호
    • /
    • pp.13-30
    • /
    • 2002
  • Industrial shift workers feels suffer mental stresses which are caused by unfamiliar day sleep, noisy environment, sleeping disorder by bright light, unusual contacts with family, difficulty in meeting with friends or having formal social meetings and other social limitations such as the use of transportation. Such stresses influence health of the workers negatively. Thus the health promotion policy for shift workers should be made considering the workers' ways of living and shift work specially. This study attempted to provide basic information for development of the health promotion program for industrial shift workers by examining predictive factors influencing health promotion behaviors of those workers. In designing the study, three power generation plants located in Pusan and south Kyungsang province were randomly selected and therefrom 280 workers at central control, boiler and turbine rooms and environmental chemistry parts whose processes require shift works were sampled as subjects of the study. Data were collected two times from September 17 to October 8, 1999 using questionnaires with helps of safety and health managers of the plants. The questionnaires were distributed through mails or direct visits. Means for the study included the measurement tool of health promotion behavior provided by Park(1995), the tool of self-efficacy measurement by Suh(1995), the tool of internal locus of control measurement by Oh(1987), the measurement tool of perceived health state by Park(1995) and the tool of social support measurement by Paek(1995). The collected data were analyzed using SPSS program. Controlling factors of the subjects were evaluated in terms of frequency and percentage ratio Perceived factors and health promotion behaviors of the subjects were done so in terms of mean and standard deviation, and average mark and standard deviation, respectively. Relations between controlling and perceived factors were analyzed using t-test and ANOVA and those between perceived factors and the performance of health promotion behaviors, using Pearson's Correlation Coefficient. The performance of health promotion behaviors was tested using t-test, ANOVA and post multi-comparison (Scheffe test). Predictive factors of health promotion behavior were examined through the Stepwise Multiple Regression Analysis. Results of the study are summarized as follows. 1. The performance of health promotion behaviors by the subjects was evaluated as having the value of mean, $161.27{\pm}26.73$ points(min.:60, max.:240) and average mark, $2.68{\pm}0.44$ points(min.:1, max.:4). When the performance was analyzed according to related aspects, it showed the highest level in harmonious relation with average mark, $3.15{\pm}.56$ points, followed by hygienic life($3.03{\pm}.55$), self-realization ($2.84{\pm}.55$), emotional support($2.73{\pm}.61$), regular meals($2.71{\pm}.76$), self-control($2.62{\pm}.63$), health diet($2.62{\pm}.56$), rest and sleep($2.60{\pm}.59$), exercise and activity($2.53{\pm}.57$), diet control($2.52{\pm}.56$) and special health management($2.06{\pm}.65$). 2. In relations between perceived factors of the subjects(self-efficacy, internal locus of control, perceived health state) and the performance of health promotion behaviors, the performance was found having significantly pure relations with self-efficacy (r=.524, P=.000), internal locus of control (r=.225, P=.000) and perceived health state(r=.244, P=.000). The higher each evaluated point of the three factors was, the higher the performance was in level. 3. When relations between the controlling factors(demography-based social, health-related, job-related and human relations characteristics) and the performance of health promotion behaviors were analyzed, the performance showed significant differences according to marital status (t=2.09, P= .03), religion(F=3.93, P= .00) and participation in religious activities (F=8.10, P= .00) out of demography-based characteristics, medical examination results (F=7.20, P= .00) and methods of the collection of health knowledge and information(F=3.41, P= .01) and methods of desired health education(F=3.41, P= .01) out of health-related characteristics, detrimental factors perception(F=4.49, P= .01) and job satisfaction(F=8.41, P= .00) out of job-related characteristics and social support(F=14.69, P= .00) out of human relations characteristics. 4. The factor which is a variable predicting best the performance of health promotion behaviors by the subjects was the self-efficacy accounting for 27.4% of the prediction, followed by participation in religious activities, social support, job satisfaction, received health state and internal locus of control in order all of which totally account for 41.0%. In conclusion, the predictive factor which most influence the performance of health promotion behaviors by shift workers was self-efficacy. To promote the sense, therefore, it is necessary to develop the nursing intervention program considering predictive factors as variables identified in this study. Further industrial nurses should play their roles actively to help shift workers increase their capability of self-management of health.

  • PDF

Comparative study on the performance of Pod type waterjet by experiment and computation

  • Kim, Moon-Chan;Park, Warn-Gyu;Chun, Ho-Hwan;Jung, Un-Hwa
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제2권1호
    • /
    • pp.1-13
    • /
    • 2010
  • A comparative study between a computation and an experiment has been conducted to predict the performance of a Pod type waterjet for cm amphibious wheeled vehicle. The Pod type waterjet has been chosen on the basis of the required specific speed of more than 2500. As the Pod type waterjet is an extreme type of axial flow type waterjet, theoretical as well as experimental works about Pod type waterjets are very rare. The main purpose of the present study is to validate and compare to the experimental results of the Pod type waterjet with the developed CFD in-house code based on the RANS equations. The developed code has been validated by comparing with the experimental results of the well-known turbine problem. The validation also extended to the flush type waterjet where the pressures along the duct surface and also velocities at nozzle area have been compared with experimental results. The Pod type waterjet has been designed and the performance of the designed waterjet system including duct, impeller and stator was analyzed by the previously mentioned m-house CFD Code. The pressure distributions and limiting streamlines on the blade surfaces were computed to confirm the performance of the designed waterjets. In addition, the torque and momentum were computed to find the entire efficiency and these were compared with the model test results. Measurements were taken of the flow rate at the nozzle exit, static pressure at the various sections along the duct and also the nozzle, revolution of the impeller, torque, thrust and towing forces at various advance speed's for the prediction of performance as well as for comparison with the computations. Based on these measurements, the performance was analyzed according to the ITTC96 standard analysis method. The full-scale effective and the delivered power of the wheeled vehicle were estimated for the prediction of the service speed. This paper emphasizes the confirmation of the ITTC96 analysis method and the developed analysis code for the design and analysis of the Pod type waterjet system.

이중 콘형 부분예혼합 GT 연료노즐의 연소특성 및 발전플랜트 실증 (Combustion Characteristics and On-site Performance Test of a Double-cone Partial Premixed Nozzle with Various Fuel hole Patterns)

  • 김한석;조주형;김민국;황정재;이원준;민경욱;강도원
    • 한국가스학회지
    • /
    • 제25권6호
    • /
    • pp.22-28
    • /
    • 2021
  • 발전용 가스터빈에 사용되는 이중 콘형 예혼합 연소기의 성능 개선 및 검증을 위하여 기존 노즐에서 연료 분사 특성을 개선한 노즐(분사구 직경 증가, 분사구 수 감소, 총 분사면적 유지)을 이용하여 고압 및 다중화염 조건에서 실험 연구를 수행하였으며 배기가스 특성을 기존 노즐과 비교하였다. 실험 결과로는 노즐의 연료 직경을 크게 한 경우 연소용 공기로 연료의 침투 거리가 증가하기 때문에 콘 내부에서 연료와 공기의 혼합특성이 개선되어 상압뿐만 아니라 압력 상승 시 NOx 배출 농도는 감소하며 다중 화염의 경우 화염간 연소영역의 중첩이 감소하게 되어 NOx 배출은 감소하지만 화염 안정성은 저하된다. 연료 분사구를 개선한 노즐의 발전 플랜트 실증 결과는 실험 결과와 같이 기존 노즐에 비하여 NOx 농도가 낮게 배출되었다.

함정 통합기관제어체계의 제어로직 검증을 위한 연동신호 시뮬레이터 개발 (Development of Interlocking Signal Simulator for Verification of Naval Warship Engineering Control Logics)

  • 이헌석;손나영;심재순;오진석
    • 한국정보통신학회논문지
    • /
    • 제25권8호
    • /
    • pp.1103-1109
    • /
    • 2021
  • 통합기관제어체계(ECS)는 함정의 추진체계 전반을 제어하고 감시함으로써 함정이 안정적으로 임무를 수행할 수 있도록 하는 제어장비이다. 최근 함정의 요구성능 및 임무가 다양해짐에 따라 함정 추진체계는 과거에 비해 구성 및 제어가 복잡해지고 있다. 복잡해지고 있는 추진체계 구성에 맞춰 운용자 입장에서 편리하고 안정적인 추진체계 제어를 위해 함정의 ECS의 자동제어 기능의 요구가 증가하고 있다. 이에 따라 ECS의 안정서 및 신뢰성에 대한 검증이 요구되고 있다. 본 논문에서는 CODLOG 추진체계를 갖는 함정을 대상으로 ECS 제어로직 및 통신 프로토콜 검증을 위한 연동신호 시뮬레이터를 개발한다. 개발한 연동신호 시뮬레이터는 가스터빈, 추진전동기, 디젤발전기 외 11종의 보조기기 계통의 신호를 시뮬레이션 가능하도록 구현하였다. 개발한 연동신호 시뮬레이터는 ECS의 함 탑재이전 공작수락시험(FAT) 단계에서 ECS 콘솔과 연동하여 ECS의 통신 프로그램 및 I/O 신호의 정적 시험을 통해 ECS의 신뢰성을 검증하였다.

터보 냉동기용 핀튜브에 관한 연구 ( I ) - 응축 열전달에 관하여 - (A Study on Finned Tube Used in Turbo Refrigerator( I ) -for Condensation Hear Transfer-)

  • 조동현;한규일;김시영
    • 수산해양교육연구
    • /
    • 제5권1호
    • /
    • pp.31-44
    • /
    • 1993
  • Through the early 1900's, the evolution of the surface condenser was closely tied to the development of steam engine and the turbine. As the chemical and petroleum industries evolved in the 1900's, the use of surface condensers in many different processes. Today, industry uses condensers in many shapes and sizes. The actual condensation process occurs on the outside surface of tubes. The nature of this surface geometry affects the condenser's heat transfer performance. The first condensers were built with plain tubes. As tube manufacturing techniques advanced, manufacturers started making tubes with integral fins. In the 1940's, fin densities were limited to about 600 to 700 fins per meter(fpm) because of manufacturing procedure. Today new manufacturing techniques allow production of tubes with fin densities ranging from 750 to 1600 fpm. The integral-fin tubes investigated in this paper are nominally 19 mm diameter. Eight tubes have been used with trapezodially shaped integral-fins having fin density from 748 to 1654 fpm and 10, 30 grooves. For comparison, tests are made using a plain tube having the same inside diameter and an outside diameter equal to that at the root of the fins for the finned tubes. Betty and Katz's theoretical modelis is used to predict the R-11 condensation coefficient on horizontal integral-fin tubes having 748, 1024 and 1299 fpm. Experiments are carried out using R-11 as working fluid. The refrigerant condensates at a saturation state of $30^{\circ}C$ on the outside tube surface cooled by coolant. The amount of noncondensable gases present in the test loop is reduced to a negligible value by repeated purging. For a given heat input to the boiler and given cooling water flow rate, all test data are taken at steady state. The observed heat transfer enhancement for the finned and grooved tubes significantly exceeded that to be expected on grounds of increased area. For the eight fin tubes and one plain tube tested, the best performance has been obtained with a tube having a fin density of 1299 fpm, and a fin bight of 1.2mm and 30 grooves.

  • PDF

Enhancement of durability of tall buildings by using deep-learning-based predictions of wind-induced pressure

  • K.R. Sri Preethaa;N. Yuvaraj;Gitanjali Wadhwa;Sujeen Song;Se-Woon Choi;Bubryur Kim
    • Wind and Structures
    • /
    • 제36권4호
    • /
    • pp.237-247
    • /
    • 2023
  • The emergence of high-rise buildings has necessitated frequent structural health monitoring and maintenance for safety reasons. Wind causes damage and structural changes on tall structures; thus, safe structures should be designed. The pressure developed on tall buildings has been utilized in previous research studies to assess the impacts of wind on structures. The wind tunnel test is a primary research method commonly used to quantify the aerodynamic characteristics of high-rise buildings. Wind pressure is measured by placing pressure sensor taps at different locations on tall buildings, and the collected data are used for analysis. However, sensors may malfunction and produce erroneous data; these data losses make it difficult to analyze aerodynamic properties. Therefore, it is essential to generate missing data relative to the original data obtained from neighboring pressure sensor taps at various intervals. This study proposes a deep learning-based, deep convolutional generative adversarial network (DCGAN) to restore missing data associated with faulty pressure sensors installed on high-rise buildings. The performance of the proposed DCGAN is validated by using a standard imputation model known as the generative adversarial imputation network (GAIN). The average mean-square error (AMSE) and average R-squared (ARSE) are used as performance metrics. The calculated ARSE values by DCGAN on the building model's front, backside, left, and right sides are 0.970, 0.972, 0.984 and 0.978, respectively. The AMSE produced by DCGAN on four sides of the building model is 0.008, 0.010, 0.015 and 0.014. The average standard deviation of the actual measures of the pressure sensors on four sides of the model were 0.1738, 0.1758, 0.2234 and 0.2278. The average standard deviation of the pressure values generated by the proposed DCGAN imputation model was closer to that of the measured actual with values of 0.1736,0.1746,0.2191, and 0.2239 on four sides, respectively. In comparison, the standard deviation of the values predicted by GAIN are 0.1726,0.1735,0.2161, and 0.2209, which is far from actual values. The results demonstrate that DCGAN model fits better for data imputation than the GAIN model with improved accuracy and fewer error rates. Additionally, the DCGAN is utilized to estimate the wind pressure in regions of buildings where no pressure sensor taps are available; the model yielded greater prediction accuracy than GAIN.

오일공급 방향에 따른 타원형 베어링 손실 및 온도 특성 (Effect of Oil Supply Direction on Power Loss and Bearing Temperature of Elliptical Bearing)

  • 방경보;최용훈;조용주
    • Tribology and Lubricants
    • /
    • 제34권4호
    • /
    • pp.138-145
    • /
    • 2018
  • Elliptical bearings are widely used for large steam turbines owing to their excellent load carrying capacity and good dynamic stability. Power loss in bearings is an extremely important parameter, especially for high turbine capacities. Optimization of operation conditions and design variables such as bearing clearance and bearing length can reduce the power loss in elliptical bearings. Although changes in the oil supply method have served to increase the efficiency of the tilting pad journal bearing, it has not explicitly improved elliptical bearings. In this study, we verify the static characteristics of an elliptical bearing by changing the direction of oil supply. We evaluate the bearing power loss and bearing metal temperature, and compare the bearing performance and reliability in different test cases. The direction of oil supply is $90^{\circ}$ (9 o'clock) and $270^{\circ}$ (3 o'clock) when the rotor rotates in a counterclockwise direction. We use an elliptical bearing with an inner diameter and active length of 220.30 and 110.00 mm, respectively. Bearing power loss and bearing metal temperatures are measured and evaluated by rotor rotational speed, oil flow rate, and bearing load. The results reveal a 20 reduction in the power loss when the direction of oil supply is 90. Furthermore, the oil film on the upper part of the bearing has a high temperature when the direction of oil supply is $90^{\circ}$. In contrast, when the direction of oil supply is $270^{\circ}$, the oil film on the upper part of the bearing is relatively cold.