• Title/Summary/Keyword: Turbidity flow

Search Result 155, Processing Time 0.029 seconds

Calibration and Verification of CE-QUAL-W2 Model for Measuring Water Quality in the Daecheong Reservoir (대청호 저수지 수질해석을 해석을 위한 CE-QUAL-W2 모형의 검보정)

  • Ha, Sung-Ryong;Lee, Jae-Yil
    • Journal of Environmental Impact Assessment
    • /
    • v.17 no.6
    • /
    • pp.349-356
    • /
    • 2008
  • This paper aims to understand the effects of a turbidity flow intrusion on eutrophication in Daecheong Dam Reservoir. CE-QUAL-W2, a two-dimensional hydrodynamic and water quality model, is applied. The elevation of the reservoir water surface is used to validate the hydrodynamic model parameters and maximum fluctuations in the water surface elevations reaches about 1 m in the reservoir. During the heavy storm season, July, the thermocline submerged to less than 30 m below the surface. The thickness of the thermocline also reduced to 10 to 15 m. While the average TSS in June, the beginning of the monsoon was still low but it peaked in July due to heavy rainfall. Vertical profiles of the TSS regime in July indicated higher concentration in upper water layers and then the regime moves gradually downward in accordance with the time lapse. Due to the dam spillway opening, high concentrations of TSS attributed to storm turbidity ascended to the upper water layer by following the upward current movement and then, the regime precipitated to a layer below 30 to 40 m after September.

Depositional Environment of the Cambrian Machari Formation in the Yeongweol Area, Gangweon Province, Korea

  • Chung, Gong-Soo;Lee, Eun-Kyung
    • Journal of the Korean earth science society
    • /
    • v.23 no.1
    • /
    • pp.72-86
    • /
    • 2002
  • The Middle to Late Cambrian Machari Formation in the Machari area, Yeongweol, Korea consists of 7 lithofacies and 3 facies associations, which are thought to be deposits of carbonate ramp (mid to outer ramp) to basin environment. These lithofacies are bedded lime mudstone, laminated lime mudstone, bioclastic/peloidal packstone to grainstone, poloidal/bioclastic wackestone, conglomerate, mottled lime mudstone, and shale. Bedded lime mudstone facies, a few cm thick lime mudstone alternating with shale layer, is believed to have been deposited by intermittent dilute turbidity currents. Laminated lime mudstone facies, alternating lime mudstone with laminated shale, is interpreted to have been formed by fine-grained turbidity currents. Bioclastic/peloidal packstone to grainstone facies was deposited by turbidity current and peloidal/bioclastic wackestone faceis was deposited by debris flow. Conglomerate facies is thought to be deposits of storm activities. Mottled lime mudstone facies is interpreted to have been formed by bioturbation. Shale facies is interpreted to have been formed by suspension settling. Seven lithofacies of the Machari Formation are divided into three facies associations. Facies association I consisted of bedded lime mudstone facies, mottled lime mudstone facies, conglomerate facies, and bioclastic/peloidal packstone to grainstone facies, is interpreted to have been deposited on the mid ramp. Facies assocaition II consisted of bedded lime mudstone facies, laminated lime mudstone facies, bioclastic/peloidal packstone to grainstone facies, and peloidal/bioclastic wackestone facies is thought to be deposits of the outer ramp. Facies association III consisted of laminated lime mudstone facies and shale facies is interpreted to have been formed on the basin environment.

Analysis of Correlation Relationship for Flow and Water Quality at Up and Down Streams (수계 상하류의 유량 및 수질 상관관계 분석)

  • Chang, In-Soo;Jung, Jin-Kyeng;Park, Ki-Bum
    • Journal of Environmental Science International
    • /
    • v.19 no.6
    • /
    • pp.771-778
    • /
    • 2010
  • The prediction of discharge is very important in water resources management and plan. In this study, we have analyzed discharge data of site at up and down stream in watershed. In order to forecast discharge the regression equations were developed by measuring flow data. Also, to forecast the change of water quality followed by change of inflow the correlation relationship between inflow of the Youngchun site and the Chunhju dam was shown as very high. The forecast of inflow at the Chungju dam would be possible through flow analysis of the Youngchun site. And, it is possible to forecast water quality by flow analysis because the correlation relationship of SS and turbidity followed by change of flow for each station of investigation was very high.

Membrane Concentrate Thickening by Hollow-fiber Microfilter in Drinkin Water Treatment Processes

  • Lee, Byung-Ho
    • Korean Membrane Journal
    • /
    • v.1 no.1
    • /
    • pp.100-105
    • /
    • 1999
  • A novel system to thicken the concentrated colloidal solution from membrane water treat-ment processes was developed. A hollow-fiber microfilter(hydrophilic polyethylene nominal pore size 0.1 ${\mu}$m total surface area 0.42 m2) was installed in an acrylic housing that has an aeration port 5 cm below the membrane and a clarifier in the bottom. The concentrate was uniformly supplied from the top of the housing. Bacuum filtration caused downward flow of concentrate and as a result thickening interface. The addition of poly-aluminum chloride (PAC) resulted in rapid increase of trans-membrane pressure (TMP) and in no improvement of the filtered water turbidity and thickening process. Two types of con-centrate and concentrate turbidity had little effect on the increase of TMP and concentrate thickening. It was observed that for the same height of membrane housing membrane surface area to housing volume (A/V) ratio had significant effect on the increase of TMP. When the housing volume was increased ten times the increasing rate of TMP was three times faster as compared to the original housing. A hydraulic model successfully simulated the formation and sedimentation of thickening interface.

  • PDF

Degradation of Phenol by "TiO2 Ceramic Membrane+UV+H2O2" AOP ("TiO2 촉매막+UV+H2O2" 고도산화법(AOP)을 이용한 페놀 분해)

  • Choung, Youn Kyoo;Kim, Jin Wook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.645-654
    • /
    • 1994
  • Photocatalytic oxidation conditions of reactant recirculation flow rate 275 mL/min, aeration rate 2 LPM and $UV+TiO_2+H_2O_2$(500 mg/L) proved to be appropriate for water including organic materials treatment. With increasing turbidity and suspended solids concentration, at turbidity 10 NTU-suspended solids concentration 29 mg/L the phenol degradation efficiency increased, which in turn decreased at turbidity 50 NTU-suspended solids concentration 170 mg/L, however no significant differences were observed, demonstrating similar results with those obtained at zero turbidity and suspended solids concentration. The degradation efficiency of phenol decreased with increasing influent phenol concentrations. The $UV+TiO_2+H_2O_2$ photocatalytic advanced oxidation process conducted is considered to be possibly applied to the drinking water treatment, and the post-treatment process of biological wastewater treatment.

  • PDF

Observations of Treatment Efficiency and Fouling in Submerged Membrane Filtration Treating High-Turbidity Source Water (고탁도 원수대응 침지식 멤브레인 여과에서 공기폭기 및 용액조성에 따른 파울링 및 처리효율 관찰)

  • Jang, Hoseok;Byun, Youngkwon;Kim, Jeonghwan
    • Membrane Journal
    • /
    • v.27 no.1
    • /
    • pp.77-83
    • /
    • 2017
  • Transient behavior of fouling resistance was observed with a laboratory-scaled, submerged microfiltration membrane system treating high-turbidity source water consisting of inorganic silica particles and humic acid. Fouling mitigation efficiency with inorganic silica particles caused by aeration was reduced significantly as both humic acid and calcium ion existed together. Scanning electron microscopic observations showed that humic acid was adsorbed onto the surface of inorganic silica particles in the presence of calcium. Turbidity removal was achieved almost completely by submerged MF system regardless of feed compositions. However, the $UV_{254}$ removal of humic acid was improved in the presence of both calcium and inorganic silica particles. Additionally, increasing air-flow rate tended to increase $UV_{254}$ removal efficiency higher than 80%. This may be caused by back-transport of humic acid enhanced by inorganic silica particles providing surface for organic adsorption in the presence of calcium.

The Lago Sofia Conglomerate : Debris Flow to Hyperconcentrated Flow Deposits in a Cretaceous Submarine Channel, Southern Chile

  • Choe, Moon-Young;Sohn, Young-Kwan;Jo, Hyung-Rae;Kim, Yea-Dong
    • Ocean and Polar Research
    • /
    • v.24 no.3
    • /
    • pp.289-300
    • /
    • 2002
  • The Lago Sofia conglomerates encased in the Cretaceous Cerro Toro Formation, southern Chile, represent a gigantic submarine channel system developed along a foredeep trough. The channel system consists of several tributaries along the trough margin and a trunk channel along the trough axis. Voluminous debris flows were generated ubiquitously along the tract of the submarine channel mainly by the failure of nearby channel banks or slopes. The flows transformed immediately into multiphase flows and resulted in very thick-bedded mass-flow deposits with a peculiar structure sequence. The mass-flow deposits commonly overlie fluted or grooved surfaces and consist of a lower division of clast-supported and imbricated pebble-cobble conglomerate with common basal inverse grading, and an upper division of clast- to matrix-supported and disorganized pebble conglomerate or pebbly mudstone with abundant intraformational clasts. The structure sequence suggests a temporal succession of a turbidity current, a bipartite hyperconcentrapted flow with active clast collisions near the flow base, and a cohesive debris flow probably with a rigid plug. The multiphase flow is interpreted to have resulted from transformation of clast-rich but cohesive debris flows. Cohesive debris flows appear to transform more easily into dilute flow types in subaqueous environments because they are apt to hydroplane. This is in contrast to the flow transitions in subaerial environments where noncohesive debris flows are dominant and difficult to hydroplane.

Assessing the Action Plans in the Control Area(Soyang Reservoir) of Non-point Source Pollution (비점오염원 관리지역(소양호) 목표수질 달성도 평가)

  • Choi, Jaewan;Kang, Min-Ji;Ryu, Jichul;Kim, Dong-Il;Lim, Kyung-Jae;Shin, Dong-Seok
    • Journal of Environmental Science International
    • /
    • v.23 no.5
    • /
    • pp.839-852
    • /
    • 2014
  • The Ministry of Environment (MOE) has made more effort in managing point source pollution rather than in nonpoint source pollution in order to improve water quality of the four major rivers. However, it would be difficult to meet water quality targets solely by managing the point source pollution. As a result of the comprehensive measures established in 2004 under the leadership of the Prime Minister's Office, a variety of policies such as the designation of control areas to manage nonpoint source pollution are now in place. Various action plans to manage nonpoint source pollution have been implemented in the Soyang-dam watershed as one of the control areas designed in 2007. However, there are no tools to comprehensively assess the effectiveness of the action plans. Therefore, this study would assess the action plans (especially, BMPs) designed to manage Soyang-dam watershed with the WinHSPF and the CE-QUAL-W2. To this end, we simulated the rainfall-runoff and the water quality (SS) of the watershed and the reservoir after conducting model calibration and the model validation. As the results of the calibration for the WinHSPF, the determination coefficient ($R^2$) for the flow (Q, $m^3/s$) was 0.87 and the $R^2$ for the SS was 0.78. As the results of the validation, the former was 0.78 and the latter was 0.67. The results seem to be acceptable. Similarly, the calibration results of the CE-QUAL-W2 showed that the RMSE for the water level was 1.08 and the RMSE for the SS was 1.11. The validation results(RMSE) of the water level was 1.86 and the SS was 1.86. Based on the daily simulation results, the water quality target (turbidity 50 NTU) was not exceeded for 2009~2011, as results of maximum turbidity in '09, '10, and '11 were 3.1, 2.5, 5.6 NTU, respectively. The maximum turbidity in the years with the maximum, the minimum, and the average of yearly precipitation (1982~2011) were 15.5, 7.8, and 9.0, respectively, and therefore the water quality target was satisfied. It was discharged high turbidity at Inbuk, Gaa, Naerin, Gwidun, Woogak, Jeongja watershed resulting of the maximum turbidity by sub-basins in 3years(2009~2011). The results indicated that the water quality target for the nonpoint source pollution management should be changed and management area should be adjusted and reduced.

Measurement of Bacterial (Escherichia coil) Concentration by Flow Cytometry

  • Ji, Suk;Lee, Jung-Ok;Choi, Young-Nim
    • International Journal of Oral Biology
    • /
    • v.30 no.2
    • /
    • pp.65-69
    • /
    • 2005
  • Periodontitis is a multi-microbial disease and the comparison of a series of periodontopathogenic and non-periodontopathogenic bacteria in terms of microbe-host interaction may provide clues to understand the microbial etiology of the disease better. When we deal with twenty different bacterial species in a study, the first technical issue is how to measure the accurate concentration and use the same number of bacterial cells. We measured bacterial concentration by enumerating bacteria stained with SYTOX green for constant time using a flow cytometer and compared the results with those obtained by plate counting. Concentrations calculated by two different methods were very close. Therefore, flow cytometric counting allowed the rapid analysis of live/dead bacteria, offering the advantage of turbidity measurement and that of colony counting together.

Comparative study on cleaning effects of air scouring and unidirectional flushing considering water flow direction of water pipes (상수도관의 물 흐름 방향을 고려한 공기주입 세척 및 단방향 플러싱 공법의 세척 효과 비교 연구)

  • Seo, Jeewon;Lee, Gyusang;Kim, Kibum;Hyung, Jinseok;Kim, Taehyeon;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.5
    • /
    • pp.353-366
    • /
    • 2019
  • This research proposes an optimal flushing operation technique in an effort to prevent secondary water pollutions and accidents in aged pipes, and to improve the cleaning effect of unidirectional flushing. Water flow directions were analyzed using EPANET 2.0, while flushing and air scouring experiments in forward and reverse directions were performed in the field. In 42 experiments, average residual chlorine concentration and turbidity were improved after cleaning compared to before cleaning. It was found that even when the same cleaning method was used, further improvement of cleaning effect was possible by applying air injection and reverse direction cleaning techniques. By means of one-way ANOVA(Analysis of variance), it was also possible to statistically verify the need of actively utilizing air injection and reverse direction cleaning. Based on correlation between turbidity and TSS, the total amount of suspended solids removal was estimated for 874 flushing operations and 194 air scouring operations. The result showed that air scouring used more discharge water than flushing by an average of $4.9m^3$ yet with larger amounts of suspended solids removal by an average of 145.9 g. The result of analysis on turbidity values from 887 flushing operations showed low cleaning effect of unidirectional flushing for the pipes with diameters over 300 mm. In addition, the turbidity values measured during cleaning showed an increasing tendency as pipe age increased. The methodology and results of this research are expected to contribute to the efficient maintenance and improvement of water quality in water distribution networks. Follow-up research involving the measurement of water quality at regular time intervals during cleaning would allow a more accurate comparison of discharge water quality characteristics and cleaning effects between different cleaning methods. To this end, it is considered necessary to develop a standardized manual that can be used in the field and to provide relevant trainings.