• 제목/요약/키워드: Tunnel monitoring

Search Result 355, Processing Time 0.028 seconds

Investigation for Applicability of Bluetooth Mesh Networking in Underground Space (BMN(Bluetooth Mesh Networking)의 지하공간 적용성에 대한 사례 조사)

  • Lee, Chulho;Choi, Soon-Wook;Kang, Tae-Ho;Jeon, Jinoh;Ahn, Cheongjin;Song, Tae-Geon
    • Tunnel and Underground Space
    • /
    • v.29 no.6
    • /
    • pp.367-378
    • /
    • 2019
  • As the development of IT technology, the way to manage the underground construction site in real time using wireless network communication is being considered. Underground space is limited area compared to the ground site due to the enclosed communication environment and spatial characteristics. BMN (Bluetooth Mesh Networking) technology is a recently introduced wireless communication technology that bluetooth device acts as a repeater to form a networking mesh and monitor individual devices. This article examines the areas to be considered for analyzing the applicability of BMN technology to underground spaces, and the cases studies of wireless communication monitoring systems currently being developed. And the BMN technology which is being developed for the underground application is also introduced.

The development of Evaluation Program for the Quantitatively Instrumentation Management of Geotechnical Structures (지반구조물의 정량적인 계측관리를 위한 평가프로그램 개발)

  • Kim, Yong-Soo;Yun, Hae-Bum
    • Journal of the Korean Geosynthetics Society
    • /
    • v.11 no.4
    • /
    • pp.71-77
    • /
    • 2012
  • In this study, data collected from geotechnical instrumentation, analyzers using Stochastic methods for evaluating the state of law and the automation program was developed. Is expected based data driven non-parametric methods modeling may be useful for evaluation of complex geotechnical instrumentation installed on the system from the measurements collected. Result of the verification of assessment techniques developed by the sensing data collected from the actual ground structures (reinforced retaining wall and tunnel), PCA analysis techniques applied to the present study was to determine the structural behavior and environmental factors.

A Study of Shield TBM Tunnelling-induced Volume Loss Estimation Considering Shield Machine Configurations and Driving Data (쉴드 TBM의 장비 형상 및 굴진 데이터를 고려한 체적손실 산정 연구)

  • Park, Hyunku;Chang, Seokbue;Lee, Seungbok
    • Tunnel and Underground Space
    • /
    • v.25 no.5
    • /
    • pp.397-407
    • /
    • 2015
  • Estimation of shield TBM tunnelling-induced volume loss is of great importance for ground settlement control. This study proposed a simple method for evaluation of volume loss during TBM tunnlling, which is able to take into account of shield machine configurations and main driving data in calculation. The method was applied to analyze the tunnelling cases with earth pressure balanced and slurry pressure balanced shiled TBM, and mostly, reasonable agreements with monitoring results were found. Additional discussions were made for some disagreements.

Development of Cable Tunnel Monitoring System (통신구 원격감시 시 스템 개발 및 시범운용)

  • Park, Jung-Kwon;Han, Jin-Woo;Park, Jong-Ho
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.306-309
    • /
    • 2007
  • 지하구에는 국 가의 신경이라 할 수 있 는 전력, 통신, 상수도 등 주요시설물들이 수용되어 있으며, 지 하구는 화재, 집중호우에 의한 침수, 외부침입 등의 재난에 항상노출되어 있다. 2006년 12월에 발생된 구리 전력구 화재와 2000년 여의도 공동구 화재 등에서 보듯이 화재가 발생하면 화염과 연기, 유독가스로 인해 내부로 진입할 수 없으므로 조기경보 및 조기 대처가 매우 중요하다. 따라서 본 논문에서는 지하구 중에서 통신케이블을 수용하는 통신구의 재난에 조기 대처할 수 있는 통신구 원격감시 시스템에 대해 기술하고자 한다. 통신구 원격감시 시스템은 통신구내의 침입, 침수, 화재 등을 모니터링하여 재난을 미연에 방지할 수 있도록 하고, 각 감지기 및 장치에 설정된 임계치를 초과한 경우 경보 현황을 운용자에게 알려 신속하게 조치할 수 있도록 하였으며, 시스템의 안정성과 확장성, 유지보수의 용이성 등을 고려하여 통합/분산 서버, 데이터 수집장치, 감지기 등 으로 구성 하였고, 시스템간의 연동과 호환성을 위해 표준화된 통신 프로토콜을 사용하였으며, 필요에 따라 감지기 및 장치를 수정, 추가할 수 있도록 개발하였다. 그리고 이를 검증하기 위해 부산지역의 지하철병행통신구 3.8km에 대해 시범설치하여 운용함으로써 시스템의 안정성, 운용성 등에 대해 검증하였다.

  • PDF

Computational evaluation of wind loads on a standard tall building using LES

  • Dagnew, Agerneh K.;Bitsuamlak, Girma T.
    • Wind and Structures
    • /
    • v.18 no.5
    • /
    • pp.567-598
    • /
    • 2014
  • In this paper, wind induced aerodynamic loads on a standard tall building have been evaluated through large-eddy simulation (LES) technique. The flow parameters of an open terrain were recorded from the downstream of an empty boundary layer wind tunnel (BLWT) and used to prescribe the transient inlet boundary of the LES simulations. Three different numerically generated inflow boundary conditions have been investigated to assess their suitability for LES. A high frequency pressure integration (HFPI) approach has been employed to obtain the wind load. A total of 280 pressure monitoring points have been systematically distributed on the surfaces of the LES model building. Similar BLWT experiments were also done to validate the numerical results. In addition, the effects of adjacent buildings were studied. Among the three wind field generation methods (synthetic, Simirnov's, and Lund's recycling method), LES with perturbation from the synthetic random flow approach showed better agreement with the BLWT data. In general, LES predicted peak wind loads comparable with the BLWT data, with a maximum difference of 15% and an average difference of 5%, for an isolated building case and however higher estimation errors were observed for cases where adjacent buildings were placed in the vicinity of the study building.

Experimental Study on Tip Clearance Effects for Performance Characteristics of Ducted Fan

  • Raza, Iliyas;Choi, Hyun-Min;Cho, Jin-Soo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.395-398
    • /
    • 2009
  • Currently, a new generation of ducted fan UAVs (Unmanned Aerial Vehicles) is under development for a wide range of inspection, investigation and combat missions as well as for a variety of civil roles like traffic monitoring, meteorological studies, hazard mitigation etc. The current study presents extensive results obtained experimentally in order to investigate the tip clearance effects on performance characteristics of a ducted fan for small UAV systems. Three ducted fans having different tip clearance gap and with same rotor size were examined under three different yawed conditions of calibrated slanted hot-wire probe. Three dimensional velocity flow fields were measured from hub to tip at outlet of the ducted fan. The analysis of data were done by PLEAT (Phase locked Ensemble Averaging Technique) and three non-linear differential equations were solved simultaneously by using Newton -Rhapson numerical method. Flow field characteristics such as tip vortex and secondary flow were confirmed through axial, radial and tangential velocity contour plots. At the same time, the effects of tip clearance on axial thrust and input power were also investigated by using wind tunnel measurement system. For enhancing the performance of ducted fan, tip clearance level should be as small as possible.

  • PDF

Implementing a Test Bed System of Underground Tunnel Monitoring using WSN (WSN을 이용한 지하 전력구 감시 테스트베드 시스템 구현)

  • Kim, Young-Il;Yi, Bong-Jae;Song, Jae-Ju;Shin, Jin-Ho;Lee, Jung-Il
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2006.10d
    • /
    • pp.375-378
    • /
    • 2006
  • 전력산업에 있어서 송배전 선로에 대한 안정성 확보는 중요한 요소이다. 현재 한전에서는 안정적인 전력 서비스 공급을 위하여 많은 비용을 들여 송배전 선로에 대한 감시 시스템을 구축하여 운영하고 있다. 그러나 기존의 감시 시스템은 주로 광케이블이나, PLC 등과 같은 유선을 기반으로 운영되고 있다. 유선을 기반으로 하는 감시 시스템은 많은 초기 구축 비용과 유지 보수 및 점검을 위해 지속적으로 많은 비용이 발생하게 된다. 최근 들어 유비쿼터스 컴퓨팅에 대한 연구가 많이 이루어 지면서 무선 센서 네트워크에 대한 연구가 활발히 진행되고 있다. 무선 센서 네트워크의 경우 설치가 용이하며, 유지 보수가 간단한 장점이 있어 전력산업에서도 도입을 위한 많은 연구가 진행되고 있다. 본 연구에서 제안하는 지하 전력구 감시 시스템은 무선 센서 네트워크를 이용하여 지하 전력구 내에 위치한 송전 선로에 대한 온도 정보와, 전력구 내의 다양한 가스 정보를 실시간으로 제공한다. 이러한 기능을 통해 송전 선로에 대한 이상 유무를 사전에 판단할 수 있는 정보를 제공하게 된다.

  • PDF

Suggestion of Gust Factor through Field Measurements of High-Rise Buildings (고층건물 현장계측을 통한 거스트 계수 제안)

  • Yoon, Sung-Won;Kim, Do-Hyun;Kim, Young-Moon;Kim, Dong-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.1
    • /
    • pp.69-76
    • /
    • 2008
  • The wind monitoring systems are installed in high-rise buildings to record wind response data. The measured buildings are located in Busan and Sokcho. The measured wind data are analysed in this paper to obtain the mean wind speed and direction, turbulence intensity and gust factor. By using the correlation between gust factor and turbulence intensity, the expression for gust factor based on wind data measured from the building is suggested. The field measurement data obtained here are useful for the validation of wind tunnel tests and the future design of tall building.

  • PDF

The ubiquitous information technology based tunnel safety monitoring system (uIT 기반의 터널 안전관리 모니터링시스템 구축)

  • Kim, Do-Hyoung
    • 한국IT서비스학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.260-265
    • /
    • 2007
  • 제2만덕터널은 부산시민의 생활에 반드시 필수적인 장소로 하루 10만대의 차량이 이용하는 곳이지만 터널의 노후화와 안전시설의 미비로 사고발생시 인명피해는 물론 경제적 손실 발생 가능성이 큰 터널 시설물이다. 제2만덕터널은 2005년 7윌부터 2006년 9월까지 교통사고 56건, 고장사고 44건, 화재 2건, 기타 11건의 사고가 발생한 곳으로 관리사무소 전담요원 7명이 3교대로 근무하고 있으며 CCTV 15대만으로 사고를 대비하고 있다. 터널의 중요성을 고려할 때 노후화된 터널이지만 유비쿼터스 기술 및 구조물 계측기술을 적용한 안전관리 시스템이 필요하다. 제2만덕터널은 1985년에 준공되어 현재와 같은 보다 체계적인 터널 안전 관리 기술이 적용되리 많은 터널로 USN기반 구조물, 노면, 화재, 공기, 조명센서를 이용한 실시간 모니터링과 돌발적인 교통사고 발생 시에 신속한 복구 처리를 위하여 유관기관과 연계된 긴급 지원 시스템의 구축의 좋은 모델이 될 것이다. 부산광역시에는 총 17개 터널이 있으며 그 중 11곳이 90년 이전에 구축된 것으로 본사업으로 노후화 터널의 유비쿼터스 기반의 안전관리 시스템이 개발된다면 부산을 중심으로 전국에 산재한 노후화 터널의 안전 관리 개선에 미치는 파급효과가 클 것이며 유비쿼터스 기술의 대표적 적용 사례가 될 것이다.

  • PDF

The Study on the Improvement of Environmental Assessment Method through Analysis of Environmental Investigation Results of Taean Thermal Power Plant (환경영향평가와 사후환경조사의 비교에 관한 연구 - 태안화력발전소 사례분석 -)

  • Chun, Sang-Ki;Lee, Sung-Chul
    • Journal of Environmental Impact Assessment
    • /
    • v.9 no.1
    • /
    • pp.61-74
    • /
    • 2000
  • This study compares the results of environmental impact assessment with the results of post-environmental investigation, using the case of Taean thermal power plant construction. The atmospheric and water qualities were not greatly changed before and after the construction of the power plant. However, the site of the highest concentration predicted by the atmospheric quality modeling in environmental impact assessment was different from that after operation of 4 power plants. There was also a difference in the diffusion range of thermal discharge water between the measured result(1km) and the predicted value(1.5km) with the model. Thus, environmental impact evaluation should be based on long-term (more than a year) environmental monitoring data. For the modeling of atmospheric quality and numerical thermal discharge water diffusion, appropriate models for each plant should be selected and the numerical modeling should be accompanied by computer simulation, wind tunnel test, etc. Moreover, environmental evaluation should focus more on the degree of impact on surroundings than the prediction of changes in surroundings caused by operation of plants.

  • PDF