• Title/Summary/Keyword: Tumors

Search Result 4,772, Processing Time 0.033 seconds

Development of High Intensity Focused Ultrasound (HIFU) Mediated AuNP-liposomal Nanomedicine and Evaluation with PET Imaging

  • Ji Yoon Kim;Un Chul Shin;Ji Yong Park;Ran Ji Yoo;Soeku Bae;Tae Hyeon Choi;Kyuwan Kim;Young Chan Ann;Jin Sil Kim;Yu Jin Shin;Hokyu Lee;Yong Jin Lee;Kyo Chul Lee;Suhng Wook Kim;Yun-Sang Lee
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.9 no.1
    • /
    • pp.9-16
    • /
    • 2023
  • Liposomes as drug delivery system have proved useful carrier for various disease, including cancer. In addition, perfluorocarbon cored microbubbles are utilized in conjunction with high-intensity focused-ultrasound (HIFU) to enable simultaneous diagnosis and treatment. However, microbubbles generally exhibit lower drug loading efficiency, so the need for the development of a novel liposome-based drug delivery material that can efficiently load and deliver drugs to targeted areas via HIFU. This study aims to develop a liposome-based drug delivery material by introducing a substance that can burst liposomes using ultrasound energy and confirm the ability to target tumors using PET imaging. Liposomes (Lipo-DOX, Lipo-DOX-Au, Lipo-DOX-Au-RGD) were synthesized with gold nanoparticles using an avidin-biotin bond, and doxorubicin was mounted inside by pH gradient method. The size distribution was measured by DLS, and encapsulation efficiency of doxorubicin was analyzed by UV-vis spectrometer. The target specificity and cytotoxicity of liposomes were assessed in vitro by glioblastoma U87mg cells to HIFU treatment and analyzed using CCK-8 assay, and fluorescence microscopy at 6-hour intervals for up to 24 hours. For the in vivo study, U87mg model mouse were injected intravenously with 1.48 MBq of 64Cu-labeled Lipo-DOX-Au and Lipo-DOX-Au-RGD, and PET images were taken at 0, 2, 4, 8, and 24 hours. As a result, the size of liposomes was 108.3 ± 5.0 nm at Lipo-DOX-Au and 94.1 ± 12.2 nm at Lipo-DOX-Au-RGD, and it was observed that doxorubicin was mounted inside the liposome up to 52%. After 6 hours of HIFU treatment, the viability of U87mg cells treated with Lipo-DOX-Au decreased by around 20% compared to Lipo-DOX, and Lipo-DOX-Au-RGD had a higher uptake rate than Lipo-DOX. In vivo study using PET images, it was confirmed that 64Cu-Lipo-DOX-Au-RGD was taken up into the tumor immediately after injection and maintained for up to 4 hours. In this study, drugs released from liposomes-gold nanoparticles via ultrasound and RGD targeting were confirmed by non-invasive imaging. In cell-level experiments, HIFU treatment of gold nanoparticle-coupled liposomes significantly decreased tumor survival, while RGD-liposomes exhibited high tumor targeting and rapid release in vivo imaging. It is expected that the combination of these models with ultrasound is served as an effective drug delivery material with therapeutic outcomes.

Comparative and Feasibility Evaluation of Detection Ability of Relative Dosimeters using CsPbI2Br and CsPbIBr2 Materials in Brachytherapy QA (근접방사선치료 QA에서 CsPbI2Br과 CsPbIBr2를 이용한 상대 선량계들의 검출 능력 비교 및 적용가능성 평가)

  • Seung-Woo Yang;Sung-Kwang Park
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.433-440
    • /
    • 2023
  • High dose rate brachytherapy is a cancer treatment that intensively irradiates radiation to tumors by inserting isotopes with high dose rates into the body. For such a treatment, it is necessary to deliver an accurate dose to the tumor tissue through an accurate treatment plan while delivering only a minimum dose to the normal tissue. Therefore, it is very important to check the location accuracy of the source through accurate Quality Assurance (QA) in clinical practice. However, since the source position is determined using a ruler, automatic radiographer, video monitor, etc. in clinical practice, it yields inaccurate results. In this study, a semiconductor dosimeter using CsPbI2Br and CsPbIBr2 was fabricated. And, in order to analyze whether it is more suitable for the relative QA dosimeter for brachytherapy device among the two materials, the radiation detection ability of each was compared and evaluated. In order to evaluate the radiation detection ability in brachytherapy, the reproducibility and linearity of the two materials were evaluated in 192IR. In the reproducibility evaluation, CsPbI2Br presented a Relative Standard Deviatio(RSD) of 0.98% and CsPbIBr2 presented an RSD of 3.45%. In the linearity evaluation, the coefficient of determination (R2) of CsPbI2Br was presented as 0.9998, and the R2 of CsPbIBr2 was presented as 0.9994. As a result of the evaluation, it was found that CsPbI2Br was more stable in radiation detection while satisfying the evaluation criteria in the dosimeter manufactured in this experiment. Therefore, CsPbI2Br material is suitable for application as a relative dosimeter for radiation detection in brachytherapy devices.

2021 Korean Thyroid Imaging Reporting and Data System and Imaging-Based Management of Thyroid Nodules: Korean Society of Thyroid Radiology Consensus Statement and Recommendations

  • Eun Ju Ha;Sae Rom Chung;Dong Gyu Na;Hye Shin Ahn;Jin Chung;Ji Ye Lee;Jeong Seon Park;Roh-Eul Yoo;Jung Hwan Baek;Sun Mi Baek;Seong Whi Cho;Yoon Jung Choi;Soo Yeon Hahn;So Lyung Jung;Ji-hoon Kim;Seul Kee Kim;Soo Jin Kim;Chang Yoon Lee;Ho Kyu Lee;Jeong Hyun Lee;Young Hen Lee;Hyun Kyung Lim;Jung Hee Shin;Jung Suk Sim;Jin Young Sung;Jung Hyun Yoon;Miyoung Choi
    • Korean Journal of Radiology
    • /
    • v.22 no.12
    • /
    • pp.2094-2123
    • /
    • 2021
  • Incidental thyroid nodules are commonly detected on ultrasonography (US). This has contributed to the rapidly rising incidence of low-risk papillary thyroid carcinoma over the last 20 years. The appropriate diagnosis and management of these patients is based on the risk factors related to the patients as well as the thyroid nodules. The Korean Society of Thyroid Radiology (KSThR) published consensus recommendations for US-based management of thyroid nodules in 2011 and revised them in 2016. These guidelines have been used as the standard guidelines in Korea. However, recent advances in the diagnosis and management of thyroid nodules have necessitated the revision of the original recommendations. The task force of the KSThR has revised the Korean Thyroid Imaging Reporting and Data System and recommendations for US lexicon, biopsy criteria, US criteria of extrathyroidal extension, optimal thyroid computed tomography protocol, and US follow-up of thyroid nodules before and after biopsy. The biopsy criteria were revised to reduce unnecessary biopsies for benign nodules while maintaining an appropriate sensitivity for the detection of malignant tumors in small (1-2 cm) thyroid nodules. The goal of these recommendations is to provide the optimal scientific evidence and expert opinion consensus regarding US-based diagnosis and management of thyroid nodules.

Evaluation of the effect of a Position Error of a Customized Si-Bolus Produced using a 3D-Printer: Cervical Cancer Radiation Treatment (3D 프린터를 이용하여 제작한 맞춤형 Si-Bolus의 위치 오차 효과 평가: 자궁경부암 방사선 치료)

  • Seong Pyo Hong;Ji Oh Jeong;Seung Jae Lee;Byung Jin Choi;Chung Mo Kim;Soo Il Jung;Yun Sung Shin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.35
    • /
    • pp.7-13
    • /
    • 2023
  • Purpose: In this study, we evaluated the effect of using a customized bolus on dose delivery in the treatment plan when cervical cancer protruded out of the body along with the uterus and evaluated reproducibility in patient set-up. Materials & Methods: The treatment plan used the Eclipse Treatment Planning System (Version 15.5.0, Varian, USA) and the treatment machine was VitalBeam (Varian Medical Systems, USA). The radiotherapy technique used 6 MV energy in the AP/PA direction with 3D-CRT. The prescribed dose is 1.8 Gy/fx and the total dose is 50.4 Gy/28 fx. Semiflex TM31010 (PTW, Germany) was used as the ion chamber, and the dose distribution was analyzed and evaluated by comparing the planned and measured dose according to each position movement and the tumor center dose. The first measurement was performed at the center by applying a customized bolus to the phantom, and the measurement was performed while moving in the range of -2 cm to +2 cm in the X, Y, and Z directions from the center assuming a positional error. It was measured at intervals of 0.5 cm, the Y-axis direction was measured up to ±3 cm, and the situation in which Bolus was set-up incorrectly was also measured. The measured doses were compared based on doses corrected to CT Hounsfield Unit (HU) 240 of silicon instead of the phantom's air cavity. Result: The treatment dose distribution was uniform when the customized bolus was used, and there was no significant difference between the prescribed dose and the actual measured value even when positional errors occurred. It was confirmed that the existing sheet-type bolus is difficult to compensate for irregularly shaped tumors protruding outside the body, but customized Bolus is found to be useful in delivering treatment doses uniformly.

  • PDF

Korean Clinical Imaging Guidelines for the Appropriate Use of Chest MRI (한국형 흉부 MRI 영상 진단 정당성 권고안)

  • Jiyoung Song;Bo Da Nam;Soon Ho Yoon;Jin Young Yoo;Yeon Joo Jeong;Chang Dong Yeo;Seong Yong Lim;Sung Yong Lee;Hyun Koo Kim;Byoung Hyuck Kim;Kwang Nam Jin;Hwan Seok Yong
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.562-574
    • /
    • 2021
  • MRI has the advantages of having excellent soft-tissue contrast and providing functional information without any harmful ionizing radiation. Although previous technical limitations restricted the use of chest MRI, recent technological advances and expansion of insurance coverage are increasing the demand for chest MRI. Recognizing the need for guidelines on appropriate use of chest MRI in Korean clinical settings, the Korean Society of Radiology has composed a development committee, working committee, and advisory committee to develop Korean chest MRI justification guidelines. Five key questions were selected and recommendations have been made with the evidence-based clinical imaging guideline adaptation methodology. Recommendations are as follows. Chest MRI can be considered in the following circumstances: for patients with incidentally found anterior mediastinal masses to exclude non-neoplastic conditions, for pneumoconiosis patients with lung masses to differentiate progressive massive fibrosis from lung cancer, and when invasion of the chest wall, vertebrae, diaphragm, or major vessels by malignant pleural mesothelioma or non-small cell lung cancer is suspected. Chest MRI without contrast enhancement or with minimal dose low-risk contrast media can be considered for pregnant women with suspected pulmonary embolism. Lastly, chest MRI is recommended for patients with pancoast tumors planned for radical surgery.

Assessment of Additional MRI-Detected Breast Lesions Using the Quantitative Analysis of Contrast-Enhanced Ultrasound Scans and Its Comparability with Dynamic Contrast-Enhanced MRI Findings of the Breast (유방자기공명영상에서 추가적으로 발견된 유방 병소에 대한 조영증강 초음파의 정량적 분석을 통한 진단 능력 평가와 동적 조영증강 유방 자기공명영상 결과와의 비교)

  • Sei Young Lee;Ok Hee Woo;Hye Seon Shin;Sung Eun Song;Kyu Ran Cho;Bo Kyoung Seo;Soon Young Hwang
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.4
    • /
    • pp.889-902
    • /
    • 2021
  • Purpose To assess the diagnostic performance of contrast-enhanced ultrasound (CEUS) for additional MR-detected enhancing lesions and to determine whether or not kinetic pattern results comparable to dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) of the breast can be obtained using the quantitative analysis of CEUS. Materials and Methods In this single-center prospective study, a total of 71 additional MR-detected breast lesions were included. CEUS examination was performed, and lesions were categorized according to the Breast Imaging-Reporting and Data System (BI-RADS). The sensitivity, specificity, and diagnostic accuracy of CEUS were calculated by comparing the BI-RADS category to the final pathology results. The degree of agreement between CEUS and DCE-MRI kinetic patterns was evaluated using weighted kappa. Results On CEUS, 46 lesions were assigned as BI-RADS category 4B, 4C, or 5, while 25 lesions category 3 or 4A. The diagnostic performance of CEUS for enhancing lesions on DCE-MRI was excellent, with 84.9% sensitivity, 94.4% specificity, and 97.8% positive predictive value. A total of 57/71 (80%) lesions had correlating kinetic patterns and showed good agreement (weighted kappa = 0.66) between CEUS and DCE-MRI. Benign lesions showed excellent agreement (weighted kappa = 0.84), and invasive ductal carcinoma (IDC) showed good agreement (weighted kappa = 0.69). Conclusion The diagnostic performance of CEUS for additional MR-detected breast lesions was excellent. Accurate kinetic pattern assessment, fairly comparable to DCE-MRI, can be obtained for benign and IDC lesions using CEUS.

Evaluation of Post-Neoadjuvant Chemotherapy Pathologic Complete Response and Residual Tumor Size of Breast Cancer: Analysis on Accuracy of MRI and Affecting Factors (신보강화학요법 후 유방암의 병리학적 완전 관해 예측 및 잔류 암 평가: 유방자기공명영상의 정확도 및 영향인자 분석)

  • Hyun Soo Ahn;Yeong Yi An;Ye Won Jeon;Young Jin Suh;Hyun-Joo Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.654-669
    • /
    • 2021
  • Purpose To evaluate the accuracy of MRI in predicting the pathological complete response (pCR) and the residual tumor size of breast cancer after neoadjucant chemotherapy (NAC), and to determine the factors affecting the accuarcy. Materials and Methods Eighty-eight breast cancer patients who underwent surgery after NAC at our center between 2010 and 2017 were included in this study. pCR was defined as the absence of invasive cancer on pathological evaluation. The maximum diameter of the residual tumor on post-NAC MRI was compared with the tumor size of the surgical specimen measured pathologically. Statistical analysis was performed to elucidate the factors affecting pCR and the residual tumor size-discrepancy between the MRI and the pathological measurements. Results The pCR rate was 10%. The diagnostic accuracy of MRI and the area under the curve for predicting pCR were 90.91% and 0.8017, respectively. The residual tumor sizes obtained using MRI and pathological measurements showed a strong correlation (r = 0.9, p < 0.001), especially in patients with a single mass lesion (p = 0.047). The size discrepancy between MRI and the pathological measurements was significantly greater in patients with the luminal type (p = 0.023) and multifocal tumors/non-mass enhancement on pre-NAC MRI (p = 0.047). Conclusion MRI is an accurate tool for evaluating pCR and residual tumor size in breast cancer patients who receive NAC. Tumor subtype and initial MRI features affect the accuracy of MRI.

CT Evaluation of Long-Term Changes in Common Bile Duct Diameter after Cholecystectomy (담낭 절제술 후 총담관 직경의 장기 변화에 대한 CT 평가)

  • Sung Hee Ahn;Chansik An;Seung-seob Kim;Sumi Park
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.3
    • /
    • pp.581-595
    • /
    • 2024
  • Purpose The present study aimed to investigate the frequency and extent of compensatory common bile duct (CBD) dilatation after cholecystectomy, assess the time between cholecystectomy and CBD dilatation, and identify potentially useful CT findings suggestive of obstructive CBD dilatation. Materials and Methods This retrospective study included 121 patients without biliary obstruction who underwent multiple CT scans before and after cholecystectomy at a single center between 2009 and 2011. The maximum short-axis diameters of the CBD and intrahepatic duct (IHD) were measured on each CT scan. In addition, the clinical and CT findings of 11 patients who were initially excluded from the study because of CBD stones or periampullary tumors were examined to identify distinguishing features between obstructive and non-obstructive CBD dilatation after cholecystectomy. Results The mean (standard deviation) short-axis maximum CBD diameter of 121 patients was 5.6 (± 1.9) mm in the axial plane before cholecystectomy but increased to 7.9 (± 2.6) mm after cholecystectomy (p < 0.001). Of the 106 patients with a pre-cholecystectomy axial CBD diameter of < 8 mm, 39 (36.8%) showed CBD dilatation of ≥ 8 mm after cholecystectomy. Six of the 17 patients with long-term (> 2 years) serial follow-up CT scans (35.3%) eventually showed a significant (> 1.5-fold) increase in the axial CBD diameter, all within two years after cholecystectomy. Of the 121 patients without obstruction or related symptoms, only one patient (0.1%) showed IHD dilatation > 3 mm after cholecystectomy. In contrast, all 11 patients with CBD obstruction had abdominal pain and abnormal laboratory indices, and 81.8% (9/11) had significant dilatation of the IHD and CBD. Conclusion Compensatory non-obstructive CBD dilatation commonly occurs after cholecystectomy to a similar extent as obstructive dilatation. However, the presence of relevant symptoms, significant IHD dilatation, or further CBD dilatation 2-3 years after cholecystectomy should raise suspicion of CBD obstruction.

Dose Response Relationship in Local Radiotherapy for Hepatocellular Carcinoma (원발성 간암의 국소 방사선치료 시 선량반응 관계)

  • Park Hee Chul;Seong Jinsil;Han Kwang Hyub;Chon Chae Yoon;Moon Young Myoung;Song Jae Seok;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.118-126
    • /
    • 2001
  • Purpose : In this study, it was investigated whether dose response relation existed or not in local radiotherapy for primary hepatocellular carcinoma. Materials and Methods : From January 1992 to March 2000, 158 patients were included in present study. Exclusion criteria included the presence of extrahepatic metastasis, liver cirrhosis of Child's class C, tumors occupying more than two thirds of the entire liver, and performance status on the ECOG scale of more than 3. Radiotherapy was given to the field including tumor with generous margin using 6, 10-MV X-ray. Mean tumor dose was $48.2{\pm}7.9\;Gy$ in daily 1.8 Gy fractions. Tumor response was based on diagnostic radiologic examinations such as CT scan, MR imaging, hepatic artery angiography at $4\~8$ weeks following completion of treatment. Statistical analysis was done to investigate the existence of dose response relationship of local radiotherapy when it was applied to the treatment of primary hepatocellular carcinoma. Results : An objective response was observed in 106 of 158 patients, giving a response rate of $67.1\%$. Statistical analysis revealed that total dose was the most significant factor in relation to tumor response when local radiotherapy was applied to the treatment of primary hepatocellular carcinoma. Only $29.2\%$ showed objective response in patients treated with dose less than 40 Gy, while $68.6\%\;and\;77.1\%$ showed major response in patients with $40\~50\;Gy$ and more than 50 Gy, respectively. Child-Pugh classification was significant factor in the development of ascites, overt radiation induced liver disease and gastroenteritis. Radiation dose was an important factor for development of radiation induced gastroduodenal ulcer. Conclusion : Present study showed the existence of dose response relationship in local radiotherapy for primary hepatocellular carcinoma. Only radiotherapy dose was a significant factor to predict the objective response. Further study is required to predict the maximal tolerance dose in consideration of liver function and non-irradiated liver volume.

  • PDF

The comparison of lesion localization methods in breast lymphoscintigraphy (Breast lymphoscintigraphy 검사 시 체표윤곽을 나타내는 방법의 비교)

  • Yeon, Joon ho;Hong, Gun chul;Kim, Soo yung;Choi, Sung wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.74-80
    • /
    • 2015
  • Purpose Breast lymphoscintigraphy is an important technique to present for body surface precisely, which shows a lymph node metastasis of malignant tumors at an early stage and is performed before and after surgery in patients with breast cancer. In this study, we evaluated several methods of body outline imaging to present exact location of lesions, as well as compared respective exposure doses. Materials and Methods RANDO phantom and SYMBIA T-16 were used for obtaining imaging. A lesion and an injection site were created by inserting a point source of 0.11 MBq on the axillary sentinel lymph node and 37 MBq on the right breast, respectively. The first method for acquiring the image was used by drawing the body surface of phantom for 30 sec using $Na^{99m}TcO_4$ as a point source. The second, the image was acquired with $^{57}Co$ flood source for 30 seconds on the rear side and the left side of the phantom, the image as the third method was obtained using a syringe filled with 37 MBq of $Na^{99m}TcO_4$ in 10 ml of saline, and as the fourth, we used a photon energy and scatter energy of $^{99m}Tc$ emitting from phantom without any addition radiation exposure. Finally, the image was fused the scout image and the basal image of SPECT/CT using MATLAB$^{(R)}$ program. Anterior and lateral images were acquired for 3 min, and radiation exposure was measured by the personal exposure dosimeter. We conducted preference of 10 images from nuclear medicine doctors by the survey. Results TBR values of anterior and right image in the first to fifth method were 334.9 and 117.2 ($1^{st}$), 266.1 and 124.4 ($2^{nd}$), 117.4 and 99.6 ($3^{rd}$), 3.2 and 7.6 ($4^{th}$), and 565.6 and 141.8 ($5^{th}$). And also exposure doses of these method were 2, 2, 2, 0, and $30{\mu}Sv$, respectively. Among five methods, the fifth method showed the highest TBR value as well as exposure dose, where as the fourth method showed the lowest TBR value and exposure dose. As a result, the last method ($5^{th}$) is the best method and the fourth method is the worst method in this study. Conclusion Scout method of SPECT/CT can be useful that provides the best values of TBR and the best score of survey result. Even though personal exposure dose when patients take scout of SPECT/CT was higher than another scan, it was slight level comparison to 1 mSv as the dose limit to non-radiation workers. If the scout is possible to less than 80 kV, exposure dose can be reduced, and also useful lesion localization provided.

  • PDF