• 제목/요약/키워드: Tumor perfusion

검색결과 54건 처리시간 0.02초

Spect-guidance to Reduce Radioactive Dose to Functioning Lung for Stage III Non-small Cell Lung Cancer

  • Wang, Zhong-Tang;Wei, Li-Li;Ding, Xiu-Ping;Sun, Ming-Ping;Sun, Hong-Fu;Li, Bao-Sheng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권2호
    • /
    • pp.1061-1065
    • /
    • 2013
  • Objective: To investigate the treatment effect of additional information obtained by single photon emission computed tomography (SPECT) lung perfusion imaging (LPI) in the radiotherapy planning process for patients with stage III non-small cell lung cancer (NSCLC). Methods: 39 patients with stage III NSCLC were enrolled. Gross tumor volume (GTV) was outlined by SPECT/CT images, SPECT-LPIs being used to define functional lung (FL) and non-functional lung (NFL) regions. Two sets of IMRT plans were designed to deliver 64Gy to PTV. One was a regular IMRT plan using CT images only (Plan 1), and the other was a corresponding IMRT plan using co-registered images (Plan 2). $FL_{Vx}$ (the % volume of functional lung receiving ${\geq}$x Gy) and $WL_{Vx}$ (% volume of whole lung to receive ${\geq}$x Gy) were compared by paired Student's t test. Kendalls correlation was used to analyze the factor (s) related with the FLV20 decrease. Results: Compared with plan 1, both $WL_{Vx}$ and $FL_{Vx}$ were decreased in plan 2. $WL_{V10}$, $WL_{V15}$, $WL_{V20}$, $WL_{V25}$, $WL_{V30}$ and $WL_{V35}$ decreased 9.7%, 13.8%, 17.2%, 12.9%, 9.8% and 9.8%, and $FL_{V10}$, $FL_{V15}$, $FL_{V20}$, $FL_{V25}$, $FL_{V30}$ and $FL_{V35}$ decreased 10.8%, 14.6%, 17.3%, 14.5%, 14.5% and 10.5%. $FL_{Vx}$ decreased significantly compared with $WL_{Vx}$. There were significant differences in $WL_{V10}$, $WL_{V15}$, $WL_{V20}$, $WL_{V25}$, $WL_{V3}$ and $FL_{V10}$, $FL_{V15}$, $FL_{V20}$, $FL_{V25}$, $FL_{V30}$ between plan 1 and plan 2 (P=0.002, 0.000, 0.000, 0.005, 0.027 and 0.002, 0.000, 0.000, 0.006, 0.010). According to Kendall correlation analysis, NFL had a negative relation with the percentage FLV20 decrease (r=-0.559, P<0.01), while the distance of PTV and NFL center had a significantly positive relation with the percentage of FLV20 decrease (r=0.768, P<0.01). Conclusion: Routine use of SPECT-LPI for patients undergoing radiotherapy planning for stage III NSCLC appears warranted.

원발성 폐암에서의 시험적 개흉술의 분석 (Analysis of Exploratory Thoracotomy in Non-Small Cell Lung Cancer)

  • 허재학;성숙환;김영태
    • Journal of Chest Surgery
    • /
    • 제32권6호
    • /
    • pp.536-542
    • /
    • 1999
  • 배경: 비소세포성 폐암의 치료방법 중에서 아직까지 장기 생존을 기대할 수 있는 가장 좋은 방법은 수술적 완전 절제술이지만, 그 때문에 불필요한 시험적 개흉술을 시행받는 환자도 해마다 상당한 수에서 보고되고 있다. 본 연구에서는 비소세포성 폐암에서 시행된 개흉술에서 수술적 절제가 불가능하였던 원인을 분석하여 불필요한 개흉술을 줄이는데 일조하고자 한다. 대상 및 방법: 1990년 1월부터 1996년 12월까지 본원에서 원발성 폐암으로 개흉술을 시행받은 616명의 환자중에서 시험적 개흉술을 시행받은 59명(9.6%)을 대상으로 하여 그 임상기록을 관찰하여 기관지 내시경 소견, 조직 진단 방법, 컴퓨터 단층 촬영 결과, 페기능 검사 및 폐관류 스캔, 절제가 불가능했던 원인, 수술후 보조요법 여부 등을 분석하였고, 수술후 생존기간을 추적하였다. 결과: 폐암종의 세포 유형은 편평세포암종 38명, 선암종 15명, 대세포암종 3명, 기타 3명이었고 원발부위는 우상엽 20명, 우중엽 6명, 우하엽 8명, 좌상엽 13명, 좌하엽 4명, 기타 8명이었다. 절제가 불가능했던 원인으로는 종격동내 인근조직이나 기관으로의 암세포 침윤이 41명으로 가장 많았으며, 흉강내 암세포 파종 8명, 광범위한 흉벽 침윤 3명, 피막을 포함한 림프절 암전이 2명, 기타 5명 등이었다. 추적관찰이 가능했던 58명에서 시험적 개흉술후 생존율은 12개월 생존율이 55.2%, 24 개월 생존율이 17.2% 이었고, 평균 생존기간은 14개월이었다. 폐암종의 세포유형이나 수술후 보조치료 요법에 따른 생존율의 차이는 없었다. 세포유형에 따른 특성은 편평세포암종의 경우 기관지 폐색과 무기폐를 잘 동반하였으며 종격동내 구조물로의 암세포 침윤이 시험적 개흉술을 시행한 주된 이유였다. 선암종에서는 흉강내 암세포 파종이 편평세포암종에서보다 의미있게 많았다. 결론: 본 연구의 자료분석을 통하여 시험적 개흉술을 시행받은 환자중 일부는 시험적 개흉술을 피하거나 수술적 절제를 할수도 있었을 것으로 생각되었다. 선암종으로 흉막 삼출액, 흉막내 암세포 파종이 의심되는 환자에서는 개흉술전 흉강경술을 도입하고, 편평세포암종의 종격동 침윤이 의심되는 환자에서는 MRI, 개흉술전 흉강경술의 도입등으로 수술전에 수술적 절제 가능성을 면밀히 판단하고 일단 개흉시에는 보다 적극적인 수술적 절제를 시행하는 것이 비소세포성 폐암의 시험적 개흉술을 줄이는데 필요할 것으로 사료되었다.

  • PDF

폐의 양성 및 악성 병변에서 $^{99m}Tc$ Methoxyisobutylisonitrile Lung SPECT의 진단적 가치 (Usefulness of $^{99m}Tc$ Methoxyisobutylisonitrile Lung SPECT in Benign and Malignant Lesion of the Lungs)

  • 김성숙;김기범;조영복;조인호;이경희;정진홍;이형우;이관호;이현우;김미진
    • Tuberculosis and Respiratory Diseases
    • /
    • 제43권1호
    • /
    • pp.54-62
    • /
    • 1996
  • 연구배경: $^{99m}Tc$ MIBI은 지용성 양이온으로 심근혈류에 따라 심근에 섭취되는 방사성 동위원소로써 Thallium-201과 함께 성근 관류 스캔에 사용되어 왔다. Thallium-201이 암세포에도 섭취된다는 것은 이미 잘 알려져 있으며, 최근 $^{99m}Tc$ MIBI도 심근 세포이외에 폐와 종격동의 암세포에도 섭취된다는 보고가 있다. 저지들은 $^{99m}Tc$ MIBI가 폐암의 진단이나 암세포의 임파절의 전이 유무의 확인에 어느 정도 효과적으로 사용될 수 있는지 알아보고자 하며 동시에 폐렴이나 폐결핵 등과 같은 양성 폐질환과의 감별진단에도 효과적으로 사용될 수 있을지에 관하여 알아보았다. 방법: 대상은 영남대학교 의과대학 부속병원 내과에서 원발성 폐암으로 확진된 환자 34예와 조직 검사나 객담 검사를 통하여 양성 폐질환으로 진단된 10예의 환자를 대상으로 하였다. 대상환자 모두에서 $^{99m}Tc$ MIBI lung SPECT를 시행하였으며 비슷한 시기에 시행한 흉부 단층 촬영소견과 비교하였다. $^{99m}Tc$ MIBI SPECT는 먼저 특별한 전처치없이 $^{99m}Tc$ MIBI 740MBq(20mCi)을 정맥 주사하고, 한시간 후에 고해상력 조준기를 장착한 회전 감마카메라(Prism-2000, Picker)를 이용하여 360도 회전시키면서 45개의 투사 영상을 얻었다. 각 영상은 감마 카메라에 연결된 컴퓨터에 수록되었고 Metz filter을 이용하여 여과후 역투사를 시행하였고 횡단면, 시상(矢狀, saggital)면과 coronal view를 얻었다. 각 상에서 폐암 병소, 심장 그리고 정상적인 폐 부위의 방사능을 측정하여 정상 폐에 대한 폐 병소의 섭취율(lung lesion/normal area; HT/NL), 정상 폐에 대한 심장의 섭취율(heart/normal area; HT/NL) 및 폐병소에 대한 심장의 섭취율(heart/lung lesion; HT/TR) 등의 비를 구하여 각 단면상에서의 $^{99m}Tc$ MIBI 섭취율을 비교하였다. 곁과: 원발성 폐암 34예 오해서 암병소에 $^{99m}Tc$ MIBI의 섭취가 증가되었으며 종격동 및 기관지 주변 임파절 전이부위에도 섭취가 증가되었다. 원발성 폐암과 양성 폐질환에서 병소와 정상 폐간의 섭취율의 각각 $3.79{\pm}1.82$, $1.67{\pm}0.63$로 두군간에 유의한 차이가 있었다(p<0.001). 원발성 폐암의 경우 각 조직형에 따른 병소와 정상 폐간의 섭취율의 비는 편평 상피 세포암의 경우 $3.64{\pm}1.66$, 소세포암의 경우 $3.57{\pm}0.72$, 선암의 경우 $4.31{\pm}2.28$로써 각 조직형에 따른 통계적인 차이는 없었다. 결론: $^{99m}Tc$ MIBI lung SPECT는 원발성 폐암의 진단 및 임파절 전이의 유무 확인은 물론 양성 폐질환과의 감별진단에도 도움이 될 것으로 생각된다.

  • PDF

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF