• Title/Summary/Keyword: Tubes

Search Result 3,133, Processing Time 0.024 seconds

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

Association of Serum Copper and Zinc Levels with Liver Cirrhosis and Hepatocellular Carcinoma (간경변 및 간암과 혈청 구리와 아연농도와의 관련성)

  • Hyun, Myung-Soo;Suh, Suk-Kwon;Yoon, Nung-Ki;Lee, Jong-Young;Lee, Seoung-Hoon;Lee, Mu-Sik
    • Journal of Preventive Medicine and Public Health
    • /
    • v.25 no.2 s.38
    • /
    • pp.127-140
    • /
    • 1992
  • This study was done to identify the association between serum copper and zinc levels and the cirrhosis and hepatocellular carcinoma(HCC), and to evaluate its diagnostic value on liver diseases. Sixty-three healthy persons, 60 patients with cirrhosis and 33 patients with hepatocellular carcinoma were rendomly selected and investigated for their general characteristics from October 1990 to August 1991. For analysis of the biochemical markers in liver function test and the serum copper and zinc levels, their fasting venous blood were sampled at 9:00 to 11:00 in the morning and centrifuged to separate the serum within one hour. All the samples were immediately analysed for biochemical markers and stored at $-20^{\circ}C$ in polypropylene tubes further copper and zinc analysis. Mean of serum coppper levels was $91.97{\pm}4.76{\mu}g/dl$ in control, $106.21{\pm}2.73{\mu}g/dl$ in cirrhosis and $127.05{\pm}0.77{\mu}g/dl$ in HCC. The value of HCC was statistically significantly higher than that of the control and cirrhosis(p<0.05). Serum zinc levels were $110.82{\pm}7.24{\mu}g/dl$ in control, $68.10{\pm}5.43{\mu}g/dl$ in cirrhosis and $63.78{\pm}2.20{\mu}g/dl$ in HCC. The values of cirrhosis and HCC were statistically significantly lower than that of control(p<0.05). The Cu/Zn ratio was statiatically significantly different among three groups(p<0.05). Test total protein, albumin, ALP and total bilirubin of biochemical markers of liver function were statistically significantly different among three groups(p<0.05). Differences between cirrhosis and HCC for ALT and AST, and between the control and HCC for direct bilirubin were not statistically significant. Biochemical markers statistically significantly correlated with serum copper and zinc levels and Cu/Zn ratio(p<0.05), were variable in three groups. In multiple logistic regression, odds ratio of serum copper level and Cu/Zn ratio had no statistical significance on the cirrhosis and the HCC, but that of serum sinc was statistically significant as 0.951 and 0.952(p<0.05). Serum copper and zinc levels and Cu/Zn ratio were not statistically significantly different between the cirrhosis and HCC. H\Albumin, ALP, zinc, total bilirubin and age among all variables were selected as main variables for three-group discriminant analysis. Percentage of 'grouped' cases correctly classified by these five variables was 98.4 for control, 73.4 for cirrhosis, 75.7 for HCC and 84.0 for all subjects. This study suggests that zinc level is considered to play a role as diagnostic marker on the hepatic disorders and be more useful than serum copper level and Cu/Zn ratio in diagnosis of the liver diseases.

  • PDF

The Role of Tumor Necrosis Factor-$\alpha$ and Interleukin-$1{\beta}$ as Predictable Markers for Development of Adult Respiratory Distress Syndrome in Septic Syndrome (패혈증 증후군환자에서 성인성 호흡곤란 증후군 발생의 예측 지표서의 혈중 Tumor Necrosis Factor-$\alpha$와 Interleukin-$1{\beta}$에 관한 연구)

  • Koh, Youn-Suck;Jang, Yun-Hae;Kim, Woo-Sung;Lee, Jae-Dam;Oh, Soon-Hwan;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.5
    • /
    • pp.452-461
    • /
    • 1994
  • Background: Tumor necrosis factor(TNF)-$\alpha$ and Interleukin(lL)-$1{\beta}$ are thought to play a major role in the pathogenesis of the septic syndrome, which is frequently associated with adult respiratory distress syndrome(ARDS). In spite of many reports for the role of TNF-$\alpha$ in the pathogenesis of ARDS, including human studies, it has been reported that TNF-$\alpha$ is not sensitive and specific marker for impending ARDS. But there is a possibility that the results were affected by the diversity of pathogenetic mechanisms leading to the ARDS because of various underlying disorders of the study group in the previous reports. The purpose of the present study was to evaluate the roles of TNF-$\alpha$ and IL-$1{\beta}$ as a predictable marker for development of ARDS in the patients with septic syndrome, in which the pathogenesis is believed to be mainly cytokine-mediated. Methods: Thirty-six patients of the septic syndrome hospitalized in the intensive care units of the Asan Medical Center were studied. Sixteens suffered from ARDS, whereas the remaining 20 were at the risk of developing ARDS(acute hypoxemic respiratory failure, AHRF). In all patients venous blood samples were collected in heparin-coated tubes at the time of enrollment, at 24 and 72 h thereafter. TNF-$\alpha$ and IL-$1{\beta}$ was measured by an enzyme-linked immunosorbent assay (ELISA). All data are expressed as median with interquartile range. Results: 1) Plama TNF-$\alpha$ levels: Plasma TNF-$\beta$ levels were less than 10pg/mL, which is lowest detection value of the kit used in this study within the range of the $mean{\pm}2SD$, in all of the normal controls, 8 of 16 subjects of ARDS and in 8 in 20 subjects of AHRF. Plasma TNF-$\alpha$ levels from patients with ARDS were 10.26pg/mL(median; <10-16.99pg/mL, interquartile range) and not different from those of patients at AHRF(10.82, <10-20.38pg/mL). There was also no significant difference between pre-ARDS(<10, <10-15.32pg/mL) and ARDS(<10, <10-10.22pg/mL). TNF-$\alpha$ levels were significantly greater in the patients with shock than the patients without shock(12.53pg/mL vs. <10pg/mL) (p<0.01). There was no statistical significance between survivors(<10, <10-12.92pg/mL) and nonsurvivors(11.80, <10-20.8pg/mL) (P=0.28) in the plasma TNF-$\alpha$ levels. 2) Plasma IL-$1{\beta}$ levels: Plasma IL-$1{\beta}$ levels were less than 0.3ng/mL, which is the lowest detection value of the kit used in this study, in one of each patients group. There was no significant difference in IL-$1{\beta}$ levels of the ARDS(2.22, 1.37-8.01ng/mL) and of the AHRF(2.13, 0.83-5.29ng/mL). There was also no significant difference between pre-ARDS(2.53, <0.3-8.34ngfmL) and ARDS(5.35, 0.66-11.51ng/mL), and between patients with septic shock and patients without shock (2.51, 1.28-8.34 vs 1.46, 0.15-2.13ng/mL). Plasma IL-$1{\beta}$ levels were significantly different between survivors(1.37, 0.4-2.36ng/mL) and nonsurvivors(2.84, 1.46-8.34ng/mL). Conclusion: Plasma TNF-$\alpha$ and IL-$1{\beta}$ level are not a predictable marker for development of ARDS. But TNF-$\alpha$ is a marker for shock in septic syndrome. These result could not exclude a possibility of pathophysiologic roles of TNF-$\alpha$ and IL-$1{\beta}$ in acute lung injury because these cytokine could be locally produced and exert its effects within the lungs.

  • PDF