Performance Characteristics of Water-Chilling Heat Pump Using CO2 on Control of Inverter Frequency (인버터 주파수 제어에 따른 CO2용 수냉식 열펌프의 성능 특성)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.12
    • /
    • pp.4721-4726
    • /
    • 2010
  • The performance characteristics of water-chilling heat pump using CO2 for the control of inverter frequency was investigated experimentally. An experimental apparatus is consisted of a compressor, a gas cooler, an expansion valve, an evaporator and a liquid receiver. All heat exchangers used in the test rig are counter flow type heat exchangers with concentric dual tubes, which are made of copper. The gas cooler and the evaporator consist of 6 and 4 straight sections respectively arranged in parallel, each has 2.4m length. The experimental results summarize as the following: for constant inlet temperature of evaporator and gas cooler, as mass flow rate, compression ratio and discharge pressure increases with the inverter frequency. And heating capacity and compressor work increases, but coefficient of performance(COP) decreases with the inverter frequency of compressor. As inlet temperature of secondary fluid in the evaporator increases from $15^{\circ}C$ to $25^{\circ}C$, compression ratio and compressor work decreases, but mass flow rate, heating capacity and COP increases with the inverter frequency of compressor. The above tendency is similar with performance variation with respect to the variation of inverter frequency in the conventional vapor compression refrigeration cycle.

IN VITRO DETERMINATION & QUANTIFICATION OF HYDROGEN PEROXIDE PENETRATION DURING NONVITLAL BLEACHING (무수치 표백시술시 치경부를 통한 표백제 누출량의 정량적 측정)

  • Park, Soo-Kyeong;Lee, Chung-Sik;Choi, Han-Seuk
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.19-34
    • /
    • 1996
  • It has been demonstrated that intracoronal bleaching of pulpless teeth may result in cervical root resorption. Several authors postulated that bleaching agents such as hydrogen peroxide penetrated through the dentinal tubules to damage the surrounding tissues that cause cervical root resorption. The purpose of this study was to suggest on in vitro model for direct determination of hydrogen peroxide penetration through CEJ during nonvital bleaching. In addition, this model permit the quantification of the amount of hydrogen peroxide penetrated during the procedure. Freshly extracted intact premolars, removed for orthodontic reasons were used. Root canal treatment was performed in each tooth. And then the outer surface and crown portion of the teeth was sealed with wax leaving the CEJ. The prepared teeth mounted on the wax laminates were placed in plastic assay tubes containing 1.5ml bidistilled water with their entire root, including the CEJ, submerged in the solution. The teeth were dividied into four groups. Thermo group : thermocatalytic bleaching with superoxol Walk group: walking bleaching with sodium perborate & superoxol Combi group : combination of thermocatalytic & walking bleaching Dw group : walking bleaching with sodium perborate & water The bleaching procedure was performed three times. The bleaching intervals were at 3 days. The hydrogen peroxide present in the assay system was added to ferrous ammonium sulfate resulting in ferric ion release. Upon the addition of potassium thiocyanate a ferrithiocyanate complex results, which absorbs light at the wavelength of 467nm. The radicular penetration of hydrogen peroxide in the four groups was assessed directly using spectrophotometer. The amount of hydrogen peroxide in the samples tested is determined by comparing them with a standard curve generated by known amounts of hydrogen peroxide. The results were obtained as follows : 1. In all experimental groups except the Dw group showed lower penetration amount in day 4 than day 1, there was statistical importance in the difference (P<0.05). 2. After 3rd treatment, Thermo group showed slightly increased value and narrow distribution. Walk group showed much more penetration amount and widely dispersed value. Value of Combi group showed wide distribution without regard to treatment time, but value of Dw group evenly distributed. 3. Thermo group, Walk group and Dw group showed a tendency of increasing penetration amount with increasing treatment times(P<0.01), but Combi group revealed no statistically important differences. 4. Combi group showed the highest degree of penetration. Walk group showed lower penetration than Combi group. Thermo group & Dw group showed lower than Walk group. 5. Cervical root permeability to hydrogen peroxide varied from 0 to 35 %.

  • PDF

EFFECT OF CUTTING INSTRUMENTS ON THE DENTIN BOND STRENGTH OF A SELF-ETCH ADHESIVE (상아질 삭제기구가 자가부식 접착제의 결합강도에 미치는 효과)

  • Lee, Young-Gon;Moon, So-Ra;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.1
    • /
    • pp.13-19
    • /
    • 2010
  • The purpose of this study was to compare the microshear bond strength of a self-etching primer adhesive to dentin prepared with different diamond points, carbide burs and SiC papers, and also to determine which SiC paper yield similar strength to that of dentinal surface prepared with points or burs. Fifty-six human molar were sectioned to expose the occlusal dentinal surfaces of crowns and slabs of 1.2 mm thick were made. Dentinal surfaces were removed with three diamond points, two carbide burs, and three SiC papers. They were divided into one of eight equal groups (n = 7); Group 1: standard diamond point(TF-12), Group 2: fine diamond point (TF-12F), Group 3: extrafine diamond point (TF-12EF), Group 4: plain-cut carbide bur (no. 245), Group 5: cross-cut carbide bur (no. 557), Group 6 : P 120-grade SiC paper, Group 7: P 220-grade SiC paper, Group 8: P 800-grade SiC paper. Clearfil SE Bond was applied on dentinal surface and Clearfil AP-X was placed on dentinal surface using Tygon tubes. After the bonded specimens were subjected to uSBS testing, the mean uSBS (n = 20 for each group) was statistically compared using one-way ANOV A and Tukey HSD test. In conclusion, the use of extrafine diamond point is recommended for improved bonding of Clearfil SE Bond to dentin. Also the use of P 220-grade SiC paper in vitro will be yield the results closer to dentinal surface prepared with fine diamond point or carbide burs in vivo.

Thoracoscopic Sympathectomy for a Patient with Facial Hyperhidrosis -A case report- (흉강경하 흉부교감신경절제술을 이용한 안면다한증 치료 -증례보고-)

  • Moon, Dong-Eon;Park, Byung-Cheul;Kim, Byung-Chan;Kim, Sung-Nyeon
    • The Korean Journal of Pain
    • /
    • v.9 no.2
    • /
    • pp.399-402
    • /
    • 1996
  • Endoscopic transthoracic sympathectomy (ETS) has recently become estabilished as a successful treatment for severe palmar and axillary hyperhidrosis. Descriptions have been published of neurolytic, operative and alternative endoscopic procedures involving thermocoagulation, laser coagulation, or or nonvideo-assisted ganglionectomy using equipment not widely available, with low morbidity and excellent results. All methods have advantage and disadvantages. A 19-year-old male who suffered from severe hyperhidrosis on face, palms and axillary areas, has been initially treated with stellate ganglion block in other pain clinic. He was transfered to our pain clinic for endoscopic thoracic sympathectomy. The patient was intubated left side 34 Fr. double lumen tube and positioned left semi-lateral position for right sympathectomy. Right side pneumothorax was created by clamping the ipsilateral side of the double lumen tube and aspiration of air. 11-mm trocar was introduced through incision at the third intercostal space in anterior axillary line, and then additional two 11-mm and 5-mm trocar was introduced through second and fifth intercostal space in mid axillary line. The lung was gently retracted and the parietal pleura over the heads of the appropriate ribs excised using 5-mm sharp insulated coagulating microprocesss. The T4, T3, and T2 ganglions, as well as accompanying rami communicantes, and other branchs arising from upper thoracic nerves to the brachial plexus and surrounding tissues were carefully dissected, coagulated. During sympathectomy, skin temperature of middle was continuously monitored. Elevation of palmar skin temperature intraoperatively indicated an adequate sympathectomy with a definite therapeutic effect. A No. 28 Fr. thoracotomy tube was introduced through a troca under video guidance, placed under water seal after the lung was reinflated. the controlateral side was performed same procedure. After bilateral sympathectomy, chest tubes were removed, and then, he was discharged 2 days after operation with great satisfaction. The ETS provides a well-tolerated, cost-effective alternative to thoracic sympathectomy for primary hyperhidrosis and sympathetic mediated neuropathic pain disorder. And T2 ganglion is considered the key ganglion for the treatment of primary hyperhidrosis. The low incidence of compensatory sweating may by explained by the limited extent of the sympathectomy.

  • PDF

Effect of the Centrifugation Temperature on Cortisol, $25OHD_3$ Values After Extraction (Cortisol, $25OHD_3$ 추출 후 원심 분리시 온도가 검사결과에 미치는 영향)

  • Kim, Whe-Jung;Cheon, Jun-Hong;Yoo, Seon-Hee;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.143-146
    • /
    • 2009
  • Purpose: We use the centrifugation of refrigeration state in separation of blood serum, Anti-ds-DNA, Vitamin $B_{12}$/Folate and GAD-Ab assay. However, Cortisol urine and 25-Hydroxyvitamin $D_3$ ($25OHD_3$) are conducted centrifuge at room temperature. This is troublesome that change centrifugation temperature into room temperature due to using of most assays at cold temperature. Therefore when using centrifuge after extraction of Cortisol urine and $25OHD_3$, we conducted researches on effect of the centrifugation temperature in assay results. Materials and Methods: In Cortisol urine, add dichloromethane 1.0 mL in urine $500\;{\mu}L$, mix for 15 minutes, and then centrifuge for 8 minutes at 2600rpm. In $25OHD_3$ add acetonitrile 0.5 mL in serum $200\;{\mu}L$, and then centrifuge for 8 minutes at 2600rpm. Those experiments were conducted centrifuge at room temperature and $4^{\circ}C$. And experiments conducted immediately after centrifugation at $4^{\circ}C$ and standing for 20 minutes after centrifugation $4^{\circ}C$. Results: In Cortisol urine, room temperature result in 1.93, 2.18, 2.43, 9.45, 14.2 (${\mu}g/dL$). Experiments of performing immediately after centrifuge at $4^{\circ}C$ result in 1.8, 2.0, 2.3, 8.1, 13.7 (${\mu}g/dL$). Experiments of performing after 20 minutes result in 2.1, 2.1, 2.7, 9.95, 14.35 (${\mu}g/dL$). On the other hand, the $25OHD_3$ tests conducted at room temperature result in 7.13, 26.6, 35.8, 48.2, 74.8 (ng/dL). Experiments were conducted immediately by pipetting after $4^{\circ}C$ centrifugation result in 7.53, 30.9, 40.3, 61.5, 89.1 (ng/dL) as results are higher than experiments at room temperature. The experiments that conducted centrifuge at $4^{\circ}C$ and then left at room temperature for 20 minutes result in 7.40, 32.4, 41.3, 51.6, 85.6 (ng/dL). Conclusions: Experiments were conducted by using centrifuge at $4^{\circ}C$ are higher or lower than room temperature. The differences between results of standing for 20 minutes after centrifuge at $4^{\circ}C$ and those of centrifuge at room temperature are less than conducting immediately. It is concerned that experiments conducted immediately after centrifuge at $4^{\circ}C$ are incorrect, because tubes become dim due to temperature differences between $4^{\circ}C$ and room temperature. Therefore, it is desirable to centrifuge at room temperature as manual and we should pipet promptly without stopping.

  • PDF

Assessment of VOCs Emission Characteristics from Building Materials such as Wall Paper, Paints, and Adhesives Using Small Chamber Method (소형챔버법을 이용한 건축자재 중 벽지, 페인트 및 접착제의 VOCs 방출특성 평가)

  • Lee Suk-Jo;Jang Seong-Ki;Cho Yong-Sung;Jung Kyung- Mi;Jeong Gi-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.2
    • /
    • pp.191-204
    • /
    • 2005
  • Building and furnishing materials and consumer product are important sources of volatile organic compounds(VOCs) and other aldehydes in the indoor environment. Some available evidence indicates that VOCs can cause adverse health effects to the building occupants and contribute to some of the symptoms of what we call, 'Sick House Syndrome' in Korea. The aims of this study were to evaluate the efficiency of emission system and to investigate comparison of the emission characteristics of different building materials such as wall-papers, paints, and adhesives. The emission of VOCs from building materials were determined in the small chambers defining the temperature, relative humidity, and ventilation rate in this study. VOCs were sampled for 20 minutes using Tenax-TA tubes and analysed by GC-MS with thermal desorption. The stability of conditions for temperature and relative humidity in this small chamber system showed that the fluctuation of temperature was between 25.4$\pm$0.3$^{\circ}C$ and that of relative humidity was 50.2$\pm$0.6$\%$ under the airflow rate of 167 mL/min. The emission tests from building materials resulted in TVOC emission rates of 0.011 $\~$ 3.108 mg/m$^{2}$h after 7 days. The general wall-papers emitted toluene abundantly and the natural wall-papers mainly emitted n-butanol and a minor amount of alkanes compound such as n -tetradecane. The remainder consisted of toluene, m,p -xylene, and styrene. The paints mainly emitted toluene and the adhesives mainly emitted chloroform as well as toluene. As a result, this study is expected to suggest meaningful data for future studies in exposure control through selecting healthy building materials and for the establishment of guidelines for various building materials in Korea.

A Case of Descending Necrotizing Mediastinitis (하행 괴사성 종격동염의 치험례)

  • Lee, In Soo;Choi, Hwan Jun;Lee, Han Jung;Lee, Jae Wook;Lee, Dong Gi
    • Archives of Plastic Surgery
    • /
    • v.36 no.3
    • /
    • pp.351-355
    • /
    • 2009
  • Purpose: Cervical necrotizing fasciitis tends to involve the deep soft tissues and spread caudally to the anterior chest and mediastinum, often resulting in major complications and death. It may rapidly spread into the thorax along fascial planes, and the associated diagnostic delay results in this descending necrotizing mediastinitis. So, aggressive multidisciplinary therapy with surgical drainage is mandatory. We present a very rare case of descending necrotizing mediastinitis with literature review. Methods: A 53 years old male visited our department 7 days after trauma in neck. His premorbid conditions and risk factors of necrotizing fasciitis were concealed hepatoma, trauma history, chronic liver disease, and nutrition deficit. Computed tomographic scans of the head and neck region were performed in this patient : signs of necrotizing fasciitis, were seen in the platysma, sternocleidomastoid, trapezius muscle and strap muscles of the neck. Fluid accumulations involved multiple neck spaces and mediastinum. At the time, he diagnosed as necrotizing fasciitis on his neck and anterior chest. Necrotic wound was excised serially and we treated this with the Vacuum - assisted closure(VAC, Kinetics Concepts International, San Antonio, Texas) system device. After appropriately shaping the sponge and achieving additional 3 pieces drainage tubes in the pockets, continuous negative pressure of 125 mmHg was applied. The VAC therapy was utilized for a period of 12 days. Results: We obtained satisfactory results from wide excision, abscess drainage with the VAC system, and then split thickness skin graft. The postoperative course was uneventful. Conclusion: The refined technique using the VAC system can provide a means of simple and effective management for the descending necrotizing mediastinitis, with better cosmetic and functional results. Finally, the VAC system has been adopted as the standard treatment for deep cervical and mediastinal wound infections as a result of the excellent clinical outcome.

Experimental Study of Characteristics of Three-Ring Impedance Meter and Dependence of Characteristics on Electric Conductivity of Fluids (3-ring 임피던스미터의 유체 전기 전도도 독립성에 대한 실험적 연구)

  • Kim, Jong-Rok;Ahn, Yeh-Chan;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.11
    • /
    • pp.1027-1033
    • /
    • 2010
  • A two-phase (gas-liquid) flow is a common phenomenon in fluidic systems, e.g., fluidic systems in the electro-magnetic or nuclear power generation industry and in the steel industry. The measurement of a two-phase flow is important for guaranteeing the safety of the system and for achieving the desired performance. The measurement of the void fraction, which is one of the parameters of the two-phase flow that determines the pressure drop and heat transfer coefficient, is very important. The time resolution achieved by employing the impedance method that can be used to calculate the void fraction from the impedance of the fluid is high because the electric characteristics are taken into account. Therefore, this method can be employed to accurately measure the void fraction without distortion of flow in real time by placing electrodes on the walls of the tubes. Coney analytically studied a ring-type impedance meter, which can be employed in a circular tube. The aim of this study is to experimentally verify the robustness of a three-ring impedance meter to variations in the electric conductivity of the fluid; this robustness was suggested by Coney but was not experimentally verified.

Studies on Intestinal Trematodes in Korea XVIII. Effect of Praziquantel in the Treatment of Fibricola seoulensis Infection in Albino Rats (한국의 장흡충에 관한 연구 XVIII. 흰쥐의 Fibricolu seoulensis감염에 대한 프라지관텔의 치료효과)

  • Lee, Sun-Hyeong;Chae, Jong-Il;Seo, Byeong-Seol
    • Parasites, Hosts and Diseases
    • /
    • v.23 no.1
    • /
    • pp.41-46
    • /
    • 1985
  • The therapeutic effects of praziquantel on Fibricola seoulensis infection were studied by experimental infection of albino rats with the metacercariae obtained from the snakes. Total 51 albino rats were infected each with 500 or 1, 000 meta cercariae in number through intragastric tubes. One or four weeks la er the rats were treated with 1, 5, 10 or 20 mg/kg single dose of prazipuantel and sacrificed after 3 days or 10-120 minutes to search for the worms in their small intestine. The worm recovery rate at 3 days after the treatment was 10.7 % in 1 mg/kg dose group and o. 03~0.2% in 5, 10 and 20 mg/kg groups, while that of untreated control was 51. 3%. The minimum effective dose to treat F. seoulensis infection in the rats is considered to be 5 mg/kg in single dose. By observing the distribution pattern of worms in the small intestine after the treatment, dislodgement of the worms from the duodenum, their normal habitat, to the lower portions was recognizable within as early as 10 minutes. The majority of worms was found to have descended to the ileo-caecal portion after 60-120 minutes.

  • PDF

Signal Analysis of Eddy Current Array Probe According to Size Variation of FBH Defects (배열 와전류 프로브의 FBH 결함 크기 변화에 따른 신호 해석)

  • Kim, Ji-Ho;Lim, Geon-Gyu;Lee, Hyang-Beom
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.2
    • /
    • pp.137-144
    • /
    • 2009
  • In this paper, the signal analysis of eddy current array probe was performed to analyze the electromagnetic characteristics with the variation of FBH(flat bottomed hole) defects size on steam generator tube in NPP(nuclear power plants) using the electromagnetic finite element method. To obtain the electromagnetic characteristic of probes, the governing equation was derived from Maxwell's equations, and the individual problem was analyzed by using the 3-dimensional finite element method. For the simulation FBH defects were used. The depth of FBH defects were 20%, 40%, 60%, 80% and 100% of steam generator(SG) tube thickness, and it was assumed that the defects were located on the tube outside. And the operation frequencies of 100 kHz, 300 kHz and 400 kHz were used. Material of specimen was Inconel 600 which is usually used for SG tubes in NPP. The signal difference could be observed according to the size variation of depth of FBH defects and operation frequencies. The results in this paper can be helpful when the ECT(eddy current testing) signals from EC array probe are evaluated and analyzed.